INSECT-O-CUTOR Allure 30 User manual

Mounting Options
Wall
Desk
Suspended
(Chain not supplied)
Please read these instructions carefully and store in a safe
place for future reference.
ALLURE™
As part of the Insect-O-Cutor®brand of insect control
products, Allure™is an effective and flexible commercial
flykiller which utilises highly effective Synergetic®UV tubes.
Constructed from stainless steel and UV stable polycarbonate,
Allure™can be wall mounted, ceiling suspended or desk
mounted.
Contents of package
- 1 x Allure™flykiller
- 1 x Mains cable (Type X)
- 2 x High powered UV tubes (Fitted)
- 1 x Removable catch tray (Fitted)
- 2 x Wall mounting screws and wall plugs
- 2 x Suspension keyrings
WARNING - THIS APPLIANCE MUST BE EARTHED (CLASS 1)
INSECT CONTROL PRODUCTS
Allure™utilises high powered ultra violet tubes to attract flying
insects and then electrocutes them on a killing grid, before
collecting them in a removable catch tray.
WARNING
Allure™is not to be used by persons with reduced physical,
sensory or mental capabilities, or lack of experience and
training, unless they have been given instruction.
Children should be supervised to ensure they do not play with
the appliance.
If the mains cable is damaged it must be replaced by a
specialist mains cable available from Pelsis Ltd or your
supplier.
Allure™must only be used in areas which are free of dust and
any possible explosive vapour mixture, is suitable for indoor
use only and is not suitable for use in barns, stables and similar
locations.
POSITIONING AND GUIDANCE FOR USE
FOR COMMERCIAL INDOOR USE ONLY. DEVICE NOT
CONSTRUCTED FOR USE OUTDOORS OR IN WET LOCATIONS.
Allure™should ideally be fixed around two metres above the
ground, preferably in the darkest place within the area to be
protected. Do not position the unit close to windows, skylights
or other sources of light, or where it may be obscured by
furniture, doors or other obstacles.
Allure™should ideally be in operation for 24 hours a day,
ensuring your premises are kept free of flying insects. Insects
are most attracted to Allure™units at night when there is no
competition from daylight or other light sources.
GUARANTEE
Allure™has a three year guarantee and if maintained as
recommended in these instructions should continue to work
for many years.* Use of non-approved consumables may
invalidate the guarantee.
*Excludes tubes and starters. Does not cover breakdown due to misuse, incorrect operation
or use in an incorrect application.
INSTALLATION
INSTALLATION SHOULD BE CARRIED OUT BY SERVICE
PERSONNEL ONLY.
Allure™should be mounted as shown in the mounting options
section of this document. Keep out of reach of children. Use
the removable mains lead and plug to connect Allure™to a
power supply of appropriate rating, as specified on the
specification label found on the unit.
CLEANING
CLEANING SHOULD BE CARRIED OUT BY SERVICE PERSONNEL
ONLY, AFTER ENSURING THAT THE UNIT IS DISCONNECTED
FROM THE MAINS SUPPLY.
It is recommended that cleaning is carried out regularly every
month. During cleaning the unit should be thoroughly wiped
down with a damp cloth, removing any build up of dirt.
Ensure the unit is completely dry before reconnecting it to the
power supply.
MOUNTING FIXING CENTRES
METHOD Allure 30
Wall 460mm
Desk -
Suspended 555mm
Allure™
Professional Electric Insect Control

Starter Replacement
SPECIFICATION / REPLACEMENT PARTS
Unit Allure 30
Voltage 230V ~ 50Hz
Dimensions(mm) 590 x 305 x 120
Coverage 120 Sq. Metres
Weight 4.0 Kg
Light Output 30W
Tubes 2 x TGX15-18
Starter 2 x I154
Tray T-AL30S
CATCH TRAY REMOVAL
The catch tray is connected to the power supply of the unit via a hidden switch. By
removing the catch tray, the connection is broken and power is cut to the unit. This ensures
safe access to the unit for servicing and cleaning.
NB - WHEN REPLACING THE CATCH TRAY BACK INTO ALLURE™, ENSURE IT IS PUSHED FULLY INTO
POSITION AND THAT POWER IS RESTORED TO THE UNIT.
Once the catch tray is removed, the two spring catches on the front guard can be pulled
towards the centre of the product, allowing the front guard to be swung down.
NB - THE FRONT GUARD CAN ONLY BE SWUNG DOWN ONCE THE CATCH TRAY IS REMOVED
TUBE REPLACEMENT
TUBE REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER
ENSURING THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
To ensure the efficiency of Allure™in catching flying insects, the UV tubes should be
replaced annually. After twelve months the phosphor coating that emits the correct
wavelength of UV light has burnt away and the UV output is diminished substantially.
To replace the UV tubes…
1. Remove the catch tray.
2. Swing down the front guard.
3. Rotate the tube through 90°, freeing it from the tube holder.
2. Pull the tube away from the chassis.
3. Dispose of the used UV tube in conjunction with local WEEE regulations.
STARTER REPLACEMENT
STARTER REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER
ENSURING THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
The starters provide an extra spark to initially light the UV tubes. Starters wear out and
should be replaced at the same intervals as the UV tubes.
The starters are located on the base of Allure™for ease of access. To replace the starters…
1. Rotate the starter anti-clockwise.
2. Pull the starter free from the unit.
Front Guard OpeningTube Replacement
R5 08/19
C2019
Pelsis Ltd
Information provided on these instructions is modified and
updated from time to time. This is due to the constant
redevelopment of our products. As such, it is not intended that
you should rely on it or that it should form part of any contract.
Sterling House
Grimbald Crag Close
Knaresborough
North Yorkshire
HG5 8PJ UK
T +44 (0)800 988 5359
F +44 (0)1423 863 497
W www.pelsis.com
WEEE Compliance No. WEE/GF0661QR