Inter-m PD-6359A User manual

Operation Manual
Power Distributor
PD-6359A
* Rack mount products in the Western emisphere(North America, South America,
and the Caribbean) do not have handles installed due to customer preference.

POWER DISTRIBUTOR
Welcome
Welcome
A personal welcome to you from the management and employees of Inter-M
All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value,
and we are delighted you have purchased one of our products.
We sincerely trust this product will provide years of satisfactory service, but if anything is not to your complete
satisfaction, we will endeavor to make things right.
Welcome to Inter-M, and thank you for becoming part of our worldwide extended family!
RISK OF ELECTRIC SHOCK
DO NOT O EN
CAUTION
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE ARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE ERSONNEL.
ATTENTION : RISQUE DE CHOC ELECTRIQUE ME AS
QUVRIR
WARNING
To prevent fire or shock hazard, do not
expose the unit to rain or moisture.
*WARNING FOR YOUR ROTECTION LEASE READ THE FOLLOWING-WATER AND MOISTURE: Unit should not be used near water(e.g.
near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken so than objects do
not fall and liquids are not spilled into the enclosure through openings.
*Do not install this equipment in a confined space such as a book case or similar unit.
*This apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such vases, shall be placed on the apparatus.
*This apparatus shall be connected to a mains socket outlet with a protective earthing connection.
*
It has heed to be easy to disconnect the device. To disconnect the device from power, separate AC input cable from inlet or unplug the AC Cord.
CAUTION
*These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing
other than that contained in the operating instructions unless you are qualified to do so.
NOTE
*This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to art 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
This symbol is intended to alert the user to the
presence of uninsulated “dangerous voltage” within
the product’s enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to
persons.
This symbol is intended to alert the user to the
presence of important operation and maintenance
(servicing) instructions in the literature accompanying
the appliance.
Caution: To prevent electric shock do not use this (polarized) plug with
an extension cord, receptacle or other outlet unless the
blades can be fully inserted to prevent blade exposure.
Attentions: our prévenir les chocs électriques ne pas utiliser cette
fiche polarisée avec un prolongateur, une prise de courant
on une autre sortie de courant, sauf si les lames peuvent
étre insérées à fond sans en laisser aucune partie à
découvert.
our deconnecter completement làppareil du reseau
dàlimentation. deconnecter le cordon dàlimentation de la
prise murale.
Laprise du reseau dàlimentation doit demeurer aisement
accessible.

POWER DISTRIBUTOR
1
PD-6359A
Contents
Contents
Unpacking .......................................................................................................................................2
Installation
Environment....................................................................................................................................2
Important Safety Instructions.............................................................................................................2
Features ...........................................................................................................................................3
Caution when assembling the acks ..........................................................................................3
Package and accessory includes.................................................................................................3
Equipment Setting and Checking.................................................................................................4
Front Panel ......................................................................................................................................6
ear Panel .......................................................................................................................................7
Applications ..................................................................................................................................10
Block Diagram ..............................................................................................................................11
Specifications ................................................................................................................................12
Service
Procedures....................................................................................................................................14
Schematic.....................................................................................................................................14
Parts List .......................................................................................................................................14
Variations and Options......................................................................................................14
Warranty ...................................................................................................................................14

POWER DISTRIBUTOR
2PD-6359A
Installation
Unpacking
Unpacking
Although your PD-6359A is neither complicated nor difficult to operate, we recommend you take a few minutes
to read this brief manual and familiarize yourself with the important information regarding product features,
setup and operation.
As with most electronic devices, we strongly recommend you retain the original packaging. In the unlikely event
the product must be returned for servicing, the original packaging (or reasonable equivalent) is required.
Installation
Environment
Never place this product in an environment which could alter its performance or reduce its service life. Such
environments usually include high levels of heat, dust, moisture, and vibration.
IMPO TANT SAFETY INST UCTIONS
1. Read these instructions.
2. Keep these instructions.
3. eed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including
amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and
the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.
S3125A
S3125A

POWER DISTRIBUTOR
3
PD-6359A
Caution when assembling the ACKs
Caution when assembling the ACKs
- When using this device, exclusive model for our rack should be installed.
- If you decide to use the components made of other company, rated capacity should be verified, and confirm it
with an authorized dealer nearby.
- Rated capacity should be verified.
- Connecting it while power is off.
- Connect AC and DC powers based on the power of the device to be connected.
- When supplying the rack power, interlock AC OUTLET (Switched: 15A×3/Unswitched: 3A×1) and DC power
output (DC 24V, 5A) should be less than rated outputs.
Features
Package and accessory includes
Package and accessory includes
1. LAN cable x 1EA
2. Euro Terminal Block (5.08mm pitch) 3P x 1EA
3. User manual x 1EA
Features
- ACK SYSTEM POWE CONT OL
It controls the power of the rack system.
- AC OUTLET TE MINAL
It being consisted of UNSWITC ED 1 group and SWITC ED 3 group, and SWITC ED 3 group can output AC
power sequentially. (By using the BY PASS setting switch, the time of AC power output can be controlled
sequentially.)
- SUPPLY EME GENCY POWE (DC 24V)
It can supply the battery power to the unswitched power output terminal, so it will be switched to emergency
power in case of black out to supply the DC power to the system.
- MONITO ING OF VOLTAGE SUPPLYING STATUS
The status of service voltage can be monitored through Windows program.
- EMOTE CONT OL
Power can be on/off from Windows program, and it can be controlled through the contact of remote terminal
without PC.
- AC/DC VOLT METE
The status of service voltage can be monitored through front LED display consisting.

POWER DISTRIBUTOR
4PD-6359A
Equipment Setting and Checking
Equipment Setting and Checking
1. Address Setting
1) Setup the equipment number in accordance with connecting condition by using rear panel DIP switch. If
the equipment number is not set, Err Id is displayed on AC / DC VOLT METER on front panel. When this
happens, please check the equipment number setting. (Max. 20 can be connected)
2) The Setting should be as below table, and if data number is added to switch which is ON, it will be the
equipment number.
(Ex: when number 1 and 3 switch is ON, 1 and 4 is added, so equipment number will be 5.)
2. TE MINATION Switch (LOAD/OPEN) Setting
1) For the system linked by using RS-485 communication interface, it is necessary to set the termination
switch (LOAD/OPEN) on the rear panel to stabilize data transfer.
2) Set the termination switch to LOAD only for the first and last-numbered equipment units. All others must be
set to OPEN.
※Caution: Communication error may occur if setting is performed incorrectly.
Equipment 1
S/W: LOAD
IN OUT
Equipment 2
S/W: OPEN
IN OUT
Equipment 3
S/W: OPEN
IN OUT
Equipment N
S/W: LOAD
IN OUT
Pin No. 1 2 3 4 5
Data 1 2 4 8 16
1 ON
2 ON
3 ON ON
4 ON
Address 5 ON ON
15 ON ON ON ON
16 ON

POWER DISTRIBUTOR
5
PD-6359A
3. System Check
1) After supplying the power, check the power status of devices connected to this device.
2) Remove the AC power cord, then check the operation status with battery power in case of black out.
※To prepare the black out, the battery and battery charger (PB-6207) is required.
3) Check on/off controls through remote terminal and monitoring status for communication.

POWER DISTRIBUTOR
6PD-6359A
Front Panel
Front Panel
1. AC VOLT METE
It displays the AC power voltage.
※When AC/DC is switched, the voltage is displayed after about 10 seconds.
2. DC VOLT METE
If PD-6359A is operated by AC power, DC output voltage is displayed. In case of AC power failure, if
operated with DC power then DC input voltage is displayed.
※When AC/DC is switched, the voltage is displayed after about 10 seconds.
3. AC LED
If operating power of PD-6359A is AC power, LED is turned on.
4. DC LED
If operating power of PD-6359A's is switched to DC power (battery) from AC power due to a power failure
then LED is turned on.
5. SWITCHED LED
After AC power or DC power is applied to the equipment, then LED is turned on upon power switch is pressed.
6. BY PASS LED
This indicates the active status of BY PASS function. BY PASS LED is turned on upon the 4th switch is ON at
BY PASS setting switch in the rear panel (If the equipment is operated by DC power, LED is turned on
regardless of BY PASS setting).
7. POWE LED
LED is turned on only if power switch is pressed ON after voltage of AC power or DC power is applied. (Not
to be turned on upon remote operation of PD-6359A).
8. POWE SWITCH
This switch turns the power on and off.
PD 6359A
1 2 3456 7
8

POWER DISTRIBUTOR
7
PD-6359A
ear Panel
ear Panel
1. AC OUTLET (SWITCHED 1, 2, 3)
This is the AC power output terminal. AC power is output if the power switch in the front panel is pressed
ON or activated remotely PD-6359A. AC power is to sequentially output according to the BY PASS setting
switches, and please refer 3. BY PASS setting switch for detail explanation in this regard.
2. AC OUTLET (UNSWITCHED)
It is the terminal which AC power is supplied all the times, and it connects the devices which power should
not be off.
3. BY PASS SETTING SWITCH
The switch that sets delay time upon which AC power at SWITC ED 1, 2, 3 is output in sequence. The
setting method of delay time is referred to as the following table upon which AC power is to be output by the
interval of delay time at SWITC ED 1, 2, 3. The order of output of AC Power is SWITC ED 3>SWITC ED
2> SWITC ED 1
Ex) If BY PASS setting switch is all OFF position, then AC power is output from SWITC ED 3 and then after
2 sec., AC power is output from SWITC ED 2. At 2 sec later after AC power output from SWITC ED 2,
then AC power is output from SWITC ED 1. If PD-6359A is turned off, AC power output stops in reverse
order. If 3 of BY PASS setting switch is ON position, AC power is to output simultaneously from SWITC ED
(AMP ONLY)
SWITCHED DC OUT 24V
(RACK ONLY)
SWITCHED DC OUT 24V
AC INPUT 220-240V~50/60Hz,24A,5800W
GND N L
HC
REMOTE IN
UNSWITCHED
DC OUT 24V
1 2 48 1 2 3416
ON
ADDRESS BY PASS
EMERGENCY
OFF
LINK
TERM
LOAD OPEN
IN OUT
MAX5A
MAX5A
MAX5A
TOTAL MAX 5A
G
G
SWITCHED 1 MAX10A
220-240V~50/60Hz
,2400W
SWITCHED 2 MAX10A ,2400W SWITCHED 3 MAX10A ,2400W
220-240V~50/60Hz 220-240V~50/60Hz 220-240V~50/60Hz
UNSWITCHED MAX3A ,720W
TOTAL MAX 20A, 4800W
MAX25A
1456 37
11891210
2
Delay TimeDIP Switch
1234
2 sec OFF OFF OFF OFF
1.5 sec ONOFF OFF OFF
1 sec OFF ON OFF OFF
0.5 sec OFF OFF ON OFF
BY PASSOFF OFF OFF ON

POWER DISTRIBUTOR
8PD-6359A
※If BY PASS setting switches are ON more than 2 switches then the front panel of BY PASS LED is to blink
by 2 sec interval and AC power is to output by the order of SWITC ED 3 →SWITC ED 2 →SWITC ED
1. Please do not ON PASS setting switches more than 2 switches.
4. ADD ESS SWITCH
It is the switch setting up the device number. For the details of Equipment Setting, please refer to page 4.
5. LINK IN/OUT TE MINAL
It is the communication terminal for monitoring the status of service voltage. Link In terminal is connected to
the previous device, and Link Out terminal will be connected to the next device.
※Caution: Communication error may occur if setting is performed incorrectly.
※IN/OUT Terminals are all same.
6. TE MINATION SWITCH (LOAD/OPEN)
It is the switch which is set for stable data receiving/transmitting of link in/out.
For the details of Equipment Setting, please refer to page 4.
※Caution: communication error may occur if it is not set correctly.
7. DC POWE OUTPUT TE MINAL (UNSWITCHED)
It is the terminal which supplies the power to the device operated by DC 24V.
8. EMOTE TE MINAL
This is Remote Terminal to be remotely operated PD-6359A. Please connect PD terminal at rear panel of
ECS-6216P our company’s model. Upon a contact is output from PD terminal of ECS-6216P and upon a
contact is input to remote terminal of PD-6359A then PD-6359A is to be operated automatically. Provided,
the remote control can be operated only the power switch is OFF position in the front panel.
9. DC POWE OUTPUT TE MINAL (DC OUTPUT, ONLY ACK)
It is the terminal supplying DC power to the rack system as rated 24V power output. It can be controlled with
front power switch ON/OFF.
PIN NO. Functions
1 RS-485 Data - A
2 RS-485 Data - B
3 RS-485 Data - Z
4 NA
5 GND
6 RS-485 Data - Y
7 NA
8 NA

POWER DISTRIBUTOR
9
PD-6359A
10. DC POWE OUTPUT TE MINAL (DC OUTPUT, ONLY AMP)
It is the terminal which outputs the emergency DC power (Battery) in case of AC black out. Connect it to
AMP DC INPUT.
11. AC INPUT TE MINAL
It is the terminal for connecting AC power. Do not bend, pull, twist, heat and cut by force. It may cause
electric shock.
Power overloading may cause the power to be turned off automatically to protect the circuit of the
equipment. Remove the cable connected to the DC power output terminal (UNSWITC ED, RACK ONLY),
disconnect the power cable, and wait 10 seconds, and connect again.
12. DC 24V BATTE Y INPUT TE MINAL (BATTE Y INPUT)
It is the terminal which connects the emergency power to use the system in case of black out, and It normally
connects to the battery. Caution to polarities when it connects.

POWER DISTRIBUTOR
10 PD-6359A
Application
Application
(AMP ONLY)
SWITCHED DC OUT 24V
(RACK ONLY)
SWITCHED DC OUT 24V
AC INPUT 220-240V~50/60Hz,24A,5800W
N L
HC
REMOTE IN
UNSWITCHED
DC OUT 24V
1 2 48 123416
ON
ADDRESS BY PASS
EMERGENCY
OFF
LINK
TERM
LOAD OPEN
IN OUT
MAX5A
MAX5A
MAX5A
TOTAL MAX 5A
SWITCHED 1 MAX10A
220-240V~50/60Hz
,2400W SWITCHED 2 MAX10A,2400W SWITCHED 3 MAX10A,2400W
220-240V~50/60Hz 220-240V~50/60Hz 220-240V~50/60Hz
UNSWITCHED MAX3A,720W
TOTAL MAX 20A, 4800W
MAX25A
Source

POWER DISTRIBUTOR
11
PD-6359A
Block Diagram
Block Diagram
AC
MCU
+24V
Battery
AC/DC
SMPS
Relay
Relay
Relay
AC, DC
Voltage Sense
LINK IN/OUT
AC OUTLET
(UNSWITCHED)
AC OUTLET
GROUP1
AC OUTLET
GROUP2
AC OUTLET
GROUP3
DC TERMINAL
(RACK ONLY)
DC TERMINAL
(EMERGENCY)
DC TERMINAL
(UNSWITCHED)
DC TERMINAL
(AMP ONLY)
HARDWARE
MCU
CONTROL
DC SOURCE
AC SOURCE
CONTROL
Display
Status
LEDs
Power
Switch
Remote
Switch
BY PASS
Switch
Address
Switch
Relay
Regulator
Relay
Relay
RS-485
RELAY CTRL
RELAY CTRL
PWR CTRL
+3.3V
+5V
+24V DC/DC

POWER DISTRIBUTOR
12 PD-6359A
PD-6359A
AC/DC Output
AC
SWITC ED: 10A, 3Group
(3 Group × 3 = 9 channel)
UNSWITC ED: 3A, 1Group (2 channel)
DC
UNSWITC ED: 1 channel (24V, 5A Max)
EMERGENCY: 1 channel (24V, 5A Max)
AMP ONLY: 9 channel (24V, 25A Max)
RACK ONLY: 4 channel (24V, 5A Max)
Sequential Power Delay BY PASS ~ 2 sec (0.5 step)
Communication RS-485
Operation Temperature -10°C ~ 40°C
Power Source AC 220-240V, 50/60 z
Power Consumption 5.8kW
Weight (SET) 5.8kg/12.8lb
Dimensions (SET) 482(W)×132( )×280(D)mm/18.98(W)×5.20( )×11.02(D)in
Specifications
Specifications
* Design and specification are subject to be changed for the improvement of product quality without pre notice.

POWER DISTRIBUTOR
13
PD-6359A
※ DIMENSIONS
440
280
482
132

POWER DISTRIBUTOR
14 PD-6359A
Service
Service
Procedures
Take steps to insure the problem is not related to operator error or other products within the system. Information
provided in the troubleshooting portion of this manual may help with this process. Once it is certain that the
problem is related to the product contact your warranty provider as described in the warranty section of this
manual.
Schematic
A Schematic is available by contacting your warranty provider.
Parts List
A Parts List is available by contacting your warranty provider.
Variations and Options
Variations and Options
Variations
Products supplied through legitimate sources are compatible with local AC power requirements.
Options
No optional items are available for this product.
Warranty
Warranty
Warranty terms and conditions vary by country and may not be the same for all products. Terms and conditions
of warranty for a given product may be determined first by locating the appropriate country which the product
was purchased in, then by locating the product type.
To obtain specific warranty information and available service locations contact Inter-M directly or the
authorized Inter-M Distributor for your specific country or region.

15
PD-6359A
NOTE

16 PD-6359A
NOTE

POWER DISTRIBUTOR
17
PD-6359A

MADE IN KOREA
July 2019 140672
Inter-M, Ltd. (Korea) began operations in 1983.
Since then, Inter-M has grown to become one of the largest manufacturers
of professional audio and commercial sound electronics equipment in the world.
Inter-M has gained worldwide recognition for its own branded products,
as well as private label manufacturing of electronics sold under other names (OEM).
The company is no longer just a Korean company, but rather a global company
that is truly international in scope, with factories and offices in Korea and China,
and sales and marketing operations located in Japan, Europe, and the U.S.A.
With more than 850 employees around the globe,
Inter-M is well-poised for further growth and expansion.
Inter-M Americas, INC.
5666 CORPORATE AVE. CYPRESS, CA 90630
TEL : +1-714-828-2200, FAX : +1-714-828-2210
ome Page : http://www.inter-m.net, E-mail : [email protected]
Inter-M Corporation
SEOUL OFFICE : 719, DOBONG-RO, DOBONG-GU, SEOUL, KOREA
TEL : +82-2-2289-8140~8, FAX : +82-2-2289-8149
ome Page : http://www.inter-m.com, E-mail : [email protected]
This manual suits for next models
1
Table of contents
Other Inter-m Power Distribution Unit manuals
Popular Power Distribution Unit manuals by other brands

Westell
Westell NPTPA1123 Technical practice

Penn Elcom
Penn Elcom PDU-UK-6 Operation and user's guide

Schulte
Schulte EVOline Port Operating and assembly instructions

MidNite Solar
MidNite Solar DIY E-Panel owner's manual

Sygonix
Sygonix 551692 operating instructions

Walther Systemtechnik
Walther Systemtechnik WMV-03-K-14-14-01 installation manual