manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Intermatic
  6. •
  7. Control Panel
  8. •
  9. Intermatic PE30000 Series Manual

Intermatic PE30000 Series Manual

PE SERIES POOL/SPA
EQUIPMENT CONTROLS
INSTALLATION
OPERATION &
SERVICE MANUAL
M
M
o
o
d
d
e
e
l
l
:
:
P
P
E
E
3
3
0
0
0
0
0
0
0
0
S
S
e
e
r
r
i
i
e
e
s
s
C
C
O
O
N
N
T
T
R
R
O
O
L
L
P
P
A
A
N
N
E
E
L
L
F
F
O
O
R
R
I
I
N
N
D
D
O
O
O
O
R
R
/
/
O
O
U
U
T
T
D
D
O
O
O
O
R
R
U
U
S
S
E
E
Suitable for Pool Equipment Control and for Direct Connection to a Wet-Niche or No-Niche Luminaire
E
EL
LE
EC
CT
TR
RI
IC
CA
AL
LR
RA
AT
TI
IN
NG
GS
S:
:S
Se
ee
ei
in
ns
si
id
de
ee
en
nc
cl
lo
os
su
ur
re
ed
do
oo
or
r.
.
ALL DEVICES IN THIS CONTROL MUST BE SUPPLIED BY BRANCH CIRCUIT PROTECTORS LOCATED WITHIN THIS ENCLOSURE.
P
P1
13
35
53
3M
ME
ED
Di
ig
gi
it
ta
al
lT
Ti
im
me
eC
Cl
lo
oc
ck
k:
:S
Se
ee
er
ra
at
ti
in
ng
gi
in
ns
si
id
de
ee
en
nc
cl
lo
os
su
ur
re
ed
do
oo
or
r(
(C
Cl
lo
oc
ck
kn
no
ot
ti
in
nc
cl
lu
ud
de
ed
dw
wi
it
th
ha
al
ll
lm
mo
od
de
el
ls
s)
)
The short circuit current rating of this panel board is 10,000 symmetrical amperes.
Many of today’s energy efficient pools and
spas utilize the advantages of a single
electrical panel, containing all the necessary
controls for the safe, efficient and automatic
operation of the pool/spa equipment. In
addition, this panel can also be used to
control any outdoor equipment, sign or pump
within its rated capacity.
As an option this all-weather enclosure
contains the heavy-duty, industrial grade
P133ME Digital Time Clock. It also comes
standard with a breaker base for up to eight
full size circuit breakers. In addition, it has
provisions to install a switch inside as well as
a switch or GFCI receptacle on the outside.
The P1353ME Digital Time Clock (optional) is
designed to operate any pump, within its
rated capacity. However, if protection to
prevent dry start is required by the pump
manufacturer, it must be provided in addition
to this control. Contact pump manufacturer if
not sure and/or for more details.
1
DANGER! TO AVOID RISK OF INJURY:
...do not permit children to operate the Control Unit or use the Pool/Spa unless they are closely supervised at all times.
...test GROUND FAULT protection regularly. If it fails to reset, DO NOT USE THE POOL or SPA!
Contact a qualified service technician.
...always disconnect electricity before servicing this control or the equipment connected to it.
READ, FOLLOW AND SAVE THIS INSTRUCTION MANUAL
GENERAL INFORMATION
Because of our commitment to continuing research and improvements, Intermatic Incorporated reserves the right to make changes, without notice, in the specifications and material
contained herein and shall not be responsible for any damages, direct or consequential, caused by reliance on the material presented.
INTERMATIC INCORPORATED, SPRING GROVE, IL 60081-9698
http://www.intermatic.com
158PE13013 4
LIMITED ONE YEAR WARRANTY
If within the warranty period specified, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace
it, at its sole option, free of charge. This warranty is extended to the original house hold purchaser only and is not transferable. this warranty does
not apply to: (a) damage to units caused by accident, dropping or abuse in handling, acts of God or any negligent use; (b) units which have been
subject to unauthorized repair, opened, taken apart or otherwise modified; (c) units not used in accordance with instructions; (d) damages exceed-
ing the cost of the product; (e) sealed lamps and/or lamp bulbs, LED’s and batteries; (f) the finish on any portion of the product, such as surface
and/or weathering, as this is considered normal wear and tear; (g) transit damage, initial installation costs, removal costs, or reinstallation costs.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLU-
SION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS
WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MER-
CHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS
LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOT ALLOW LIM-
ITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Warranty service is available by
mailing postage prepaid to: Intermatic Incorporated/After Sales Service, 7777 Winn Rd., Spring Grove, IL 60081-9698/815-675-7000
http://www/intermatic.com
WIRING DIAGRAM
NOTES: 1. Grounding connections are not shown but must be provided. Refer to the National Electrical Code for details.
2. Diagrams above are only two of the many variations this Panel can accommodate.
P1353ME Operating instructions
1. Press PROG Key to cycle through menu options.
2. Press UP and DOWN arrow keys to change program settings.
3. Press ENTER key to save changes and exit programming mode.
4. Press ON/OFF keys to manually turn devices ON or OFF.
For more details, please refer to instruction manual booklet
NOTE: Refer to P1353ME instruction manual booklet for description of modes.
OPERATION
INSTALLATION
ACCESSORIES
TROUBLESHOOTING
2 3
IMPORTANT SAFETY INSTRUCTIONS
When installing and operating this product and other associated equipment, basic safety precautions should always be followed,
including the following:
1. Read and follow all instructions.
2. This control must be installed by a qualified electrician, according to National and Local Electrical Codes.
3. Install this control not less than 5 feet (3 meters in Canada) from inside edge of pool. USE COPPER CONDUCTORS ONLY.
4. Do not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors.
5. For control grounding, bonding, installing and the wiring of underwater lights, refer to Article 680 of the National Electrical
Code or Article 68 of the Canadian Electrical Code.
6. This control should not operate any equipment which would cause bodily injury or property damage should it be activated unexpectedly.
READ, FOLLOW AND SAVE THIS INSTRUCTION MANUAL
Figure 1
SYMPTOM CAUSE(S) CORRECTIVE ACTION
1. Display will not come “ON” 1a. Jumper on back of clock is missing Set Jumper to proper location. See
when unit is powered up? or set incorrectly. Pg.7 of instruction manual.
1b. Fuse on back of clock blown open. Replace fuse with 1/8 amps fuse.
See Pg. 7 of instruction manual.
1c. Power to clock not present. Check connections to clock.
Check circuit breakers.
2. Freeze protection circuit not 2a. Freeze Probe (P/N 178PA28A) Install Intermatic freeze probe. See
working? not installed or bad. Pg. 7 of instruction manual.
2b. Clock programming not setup. Setup freeze programming. See
Pg. 7 of instruction manual.
3. Unit does not turn “ON” or 3a. Internal ON/OFF Times have Setup ON/OFF programming. See
“OFF” at desired times? not been defined. Pg.’s 24-27 of instruction manual.
3b.ON or OFF time is in override mode. Cycle through programming menu.
See Pg.’s 24-27 of instruction
manual.
3c. Clock is in Freeze protection Review programming menu. See
Countdown Mode. Pg.’s 29 & 33 of instruction manual.
4. Display continues to blink ON 4a. Power to clock was interrupted long Set time of day on clock.See Pg. 23
and OFF? enough to lose time of day. of instruction manual.
4b. Clock still in programming mode. Press “ENTER KEY” or wait 1
minute for clock to time out.
5. Fireman switch not working? 5a. Fireman switch wires not hooked up Connect fireman switch wires to
correctly from heater. clock. See Pg. 7 of instruction
manual.
5b. Fireman switch programming not Program fireman switch settings.
defined. See Pg. 28 of instruction manual.
FLTR
PUMP
2
PUMP
1
HTR SPA JETS
AIR CLNR LITE 1 LITE 2
HIGH LOW AUX 1 AUX 2
AUX 3 W/FA
External Wired Remote Accessory
Part Number 133PE1484A
(not included with all models)
The New Intermatic Wired Remote Control allows
you to control the P1353ME from a remote
location. Included with the Wired Remote
Control is a label arrangement allowing
you toidentify each button specific to
your pool or spa equipment pad. The
new wiredremote control comes
standard with 100 foot of cable and is
designed to slip fit into any standard
1 1/2” conduit adapter. This remote works
in conjunction with the P1353ME and displays feed-
back information on the present state of the pool or
spa equipment pad.
For more information refer to instructions
provided with the accessory.
Freeze Probe Accessory
Part Number 178PA28A
(not included with all models)
The New Intermatic Freeze Probe allows
you to protect your pool or spa
equipment during an
unexpected freeze condition.
The freeze probe comes with
a 10 foot cable and plugs into
the back of the new
PM1353ME. The P1353ME
can be programmed to turn on
each or all-individual loads at any desired
outside temperature.
Heater Protection (Fireman) Switch is
standard with each Digital Time Clock.
It comes standard with a Fireman Switch
connection for your pool or spa heater.
Simply connect the two wires from your
heater thermostat to the back of the digital
clock. The fireman switch is only associated
with circuit one on the digital clock, there-
fore the filter pump should be connected to
circuit one. Program the time desired for the
cool down period and the P1353ME will
take over.
For more details, refer to instruction manual.
1.Remove the #10 hex head screws from the
outside back of the enclosure and attach
mounting brackets.
2. Select the proper location for the control panel
and hang enclosure on a flat vertical surface or
other support. When mounting the enclosure, be
sure to use hardware capable of supporting its
weight.
NOTE: The Panel will accept the main feed,
through the
Ef
, 1, 1
fQ
inch knockouts at the bot-
tom of the enclosure or through the 1-
Ef
inch
knockouts on the back of the enclosure. A
dimple is positioned on the top of the enclosure
for piloting a drill to create an overhead
entrance into the panel. The main feed must
also pass through a listed outdoor conduit hub,
mounted at the time of installation.
3. Prepare the necessary conduit runs, terminate
them at both ends and pull in the conductors as
specified by the installation layout. If this control
is used for direct conduit connection to a wet-
niche or no-niche luminaire, order one of the
following:
1/2” non-metallic - order 156PA13713A
3/4” non-metallic - order 156PA13714A
1” non-metallic - order 156PA13715A
1/2” metallic - order 156PA14336A
4. Refer to Figure 1 below.
Note that though this figure
shows a P1353ME Digital
Time Clock installed, the
P1353ME is not included on all models. See
door panel for the specific configuration and
rating of the model you are installing.
A breaker base for up to eight full size circuit
breakers is included on all models. To wire the
panel, follow the wiring diagram located inside
the enclosure door. When wiring the P1353ME,
make sure that the connections are tight (25 lb.-
in. minimum) and insulation clears the
pressure plate (see illustration).
5. If required by the heater manufacturer, the P1353ME
includes a connection for a fire-man switch. This
switch only works in conjunction with circuit #1
(Load #1) on the P1353ME. Refer to pages 6 & 7
of the P1353ME Instruction Manual for connection
information, and refer to page 28 for fireman
switch programming information. Use at least
#18 AWG wiring with insulation rated 300 volt or
higher.Some heaters may require a special
connecting harness, contact heater manufacturer
for details. Place heater ON/OFF switch on
heater to ON position.
6. To install additional wiring devices inside the
enclosure, first remove rectangular knock-
out(s) in dead front. Next, remove hex head
screws inside back of enclosure and install
stand-offs* in place of screws. Attach wiring
device to stand-offs.
*Stand-offs are not furnished. Order 21T156A for a set
of four (4) stand-offs and mounting hardware.
7. If external bonding is required, install a bonding
lug at bottom of enclosure and bond installation
according to code requirements (Order
156T11047A for Bonding Lug Kit).
8. Testing of the installation is optional and recom-
mended only if the desired loads are securely in
place and will not be damaged by this test:
a. Turn ON power at breaker panel.
b. P1353ME display should fully illuminate and
then start to blink 12:00AM provided the
memory hold-up capacitor is discharged.
Otherwise, it will display the time.
c. Push each of the ON/OFF buttons to verify
devices cycle on and off.
In case of unsatisfactory results, turn OFF
power, check your wiring, refer to
Troubleshooting on Page 3.
9. Install front panel over wiring compartment.
The control is now ready for programming,
see OPERATION section on Page 4.
PRESSURE PLATE
TERMINAL SCREW
MAKE SURE INSULATION
CLEARS PRESSURE PLATE

Other Intermatic Control Panel manuals

Intermatic PE25300RC Manual

Intermatic

Intermatic PE25300RC Manual

Intermatic PE20000 Series Manual

Intermatic

Intermatic PE20000 Series Manual

Intermatic P40000 Series Manual

Intermatic

Intermatic P40000 Series Manual

Intermatic T21000R SERIES Manual

Intermatic

Intermatic T21000R SERIES Manual

Intermatic T10604R User manual

Intermatic

Intermatic T10604R User manual

Intermatic T30000R SERIES Manual

Intermatic

Intermatic T30000R SERIES Manual

Intermatic PE45300 Manual

Intermatic

Intermatic PE45300 Manual

Intermatic PE25300 Manual

Intermatic

Intermatic PE25300 Manual

Intermatic T10404R User manual

Intermatic

Intermatic T10404R User manual

Intermatic T40000RT SERIES Manual

Intermatic

Intermatic T40000RT SERIES Manual

Intermatic PE40000 Series Manual

Intermatic

Intermatic PE40000 Series Manual

Intermatic T10000R SERIES Manual

Intermatic

Intermatic T10000R SERIES Manual

Intermatic T40000R SERIES Manual

Intermatic

Intermatic T40000R SERIES Manual

Intermatic PE10000 Series Manual

Intermatic

Intermatic PE10000 Series Manual

Intermatic T30000R SERIES Manual

Intermatic

Intermatic T30000R SERIES Manual

Intermatic INTT40404R Manual

Intermatic

Intermatic INTT40404R Manual

Intermatic PE45300 Manual

Intermatic

Intermatic PE45300 Manual

Intermatic T21000R SERIES Manual

Intermatic

Intermatic T21000R SERIES Manual

Intermatic ET90000 Series Installation guide

Intermatic

Intermatic ET90000 Series Installation guide

Intermatic T40000R4 Manual

Intermatic

Intermatic T40000R4 Manual

Intermatic P1353ME Manual

Intermatic

Intermatic P1353ME Manual

Intermatic EMPS3IN User manual

Intermatic

Intermatic EMPS3IN User manual

Intermatic T10101R Manual

Intermatic

Intermatic T10101R Manual

Popular Control Panel manuals by other brands

Carrier Infinity SYSTXCCUID01-B installation instructions

Carrier

Carrier Infinity SYSTXCCUID01-B installation instructions

emmeti FEBOS - CRONO IMX Basic / WiFi Installation and use manual

emmeti

emmeti FEBOS - CRONO IMX Basic / WiFi Installation and use manual

jablotron HESTIA-915 installation manual

jablotron

jablotron HESTIA-915 installation manual

Cooper SAFEPATH SP4-LOC Installation and operation manual

Cooper

Cooper SAFEPATH SP4-LOC Installation and operation manual

PolyVision Walk-and-Talk Installation and operation guide

PolyVision

PolyVision Walk-and-Talk Installation and operation guide

Ness R16 user manual

Ness

Ness R16 user manual

Studio Technologies 206 user guide

Studio Technologies

Studio Technologies 206 user guide

Satel ACCO-NT2 Installer manual

Satel

Satel ACCO-NT2 Installer manual

Teletek electronics MAG8Plus Installation and operation manual

Teletek electronics

Teletek electronics MAG8Plus Installation and operation manual

SLEIPNER MOTOR AS SIDE-POWER S-linkControl Panel PJC211 Installation and user manual

SLEIPNER MOTOR AS

SLEIPNER MOTOR AS SIDE-POWER S-linkControl Panel PJC211 Installation and user manual

ESYLUX PROTECTOR installation instructions

ESYLUX

ESYLUX PROTECTOR installation instructions

Essmann 4A Technical information and operating instruction

Essmann

Essmann 4A Technical information and operating instruction

EES USM manual

EES

EES USM manual

Pulsar 17/TRP50/SATEL Assembly instruction

Pulsar

Pulsar 17/TRP50/SATEL Assembly instruction

weintek cMT3072XH2 Series installation instructions

weintek

weintek cMT3072XH2 Series installation instructions

DSC PowerSeries PC1616 installation guide

DSC

DSC PowerSeries PC1616 installation guide

GRASS VALLEY Kaleido-RCP2 Installation and operation manual

GRASS VALLEY

GRASS VALLEY Kaleido-RCP2 Installation and operation manual

Daikin DCM601A51 Technical data

Daikin

Daikin DCM601A51 Technical data

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.