InterVac VacPort A900 User manual

RECORD THIS INFORMATION
FOR FUTURE REFERENCES
MODEL NUMBER: ________
DATE OF PURCHASE: ______
PLACE OF PURCHASE: ______
Manual # M-20
Date: 1/2017 Rev.:3/2022
ATTACHING VACPORT TO AN EXISTING
REMOTE INSTALLED CENTRAL VACUUM
3
3
By
3 1
5
INSTALLATION AND OPERATING MANUAL
MODEL
A900 with LED
2
#1 Elbow fitting, does not need to be installed. Used only in tight spaces.
#2 Existing 2” diameter Flex-Hose or Vacuum Pipe. If you have vacuum pipe installed
run the pipe straight into the 45 degree “T” (#4)
#3 Black Threaded Coupling, part #D900, 4 supplied. This coupling is screwed
counterclockwise into the 2” Flex-Hose, the other end attaches to a pipe fitting with
a twist and strong push. Do not glue!
#4 45 degree “T” fitting, to attach to the existing hose or pipe.
#5 Pipe coupling, to be glued to the VacPort. On the other end either glue in the elbow
#1 and press-fit the threaded coupling. If elbow is not used just press-fit a threaded
coupling #3 into the pipe coupling #5.
MODEL
A910 without LED
VacPort Model A910
Without LEDs
The door is held open by
2 small magnets.
Connect the LOW voltage
wire under screw heads.
NOT under Big Washer!
Wall Opening location Pin
Screw hole to attach VacPort to wall
Replacing the 'VacPan' or 'Vacu-Sweep' with a VacPort installation
1)
Remove old dustpan from the wall.
2)
Use the same 2 screws and attach Trim Plate,
use the holes "A" from the removed VacPan
use the holes "B" from the removed the
VacuSweep
3)
Mark the inside of the Trim Plate with a pencil.
4)
Remove Trim Plate from the wall and cut the
opening larger along the pencil line.
5)
Reattach the Trim Plate to the wall.
6)
See page 3 how to attach the 24-volt wires
and Flex-Hose.
7)
Now slide the VacPort into the new opening
and secure with the 2 #8 flat head tapping
screws and attach to the Trim Plate through
PLEASE NOTE:
THE VACPORT COMES IN 2 LED LIGHT MODES:
1)
WHEN YOU LIFT THE DOOR UP, THE LIGHT IS CONSTANTLY ON, UNTIL YOU CLOSE THE DOOR.
2)
WHEN YOU LIFT THE DOOR THE LIGHT STARTS BLINKING, UNTIL DOOR IS CLOSED.
TECHNICAL EXPLANATION:
SOME CENTRAL VACUUMS USE A “TRIAC” FOR THE LOW VOLTAGE, OTHER VACUUMS USE A TRANSFORMER TO CREATE
THE 24 VOLT OUTPUT, THE “TRIAC” CREATES THE DISTINCT BLINKING
IF YOU SHOULD HAVE ANY QUESTIONS OR EXPERIENCE A PROBLEM WITH YOUR
INTERVAC PRODUCT,
DO NOT RETURN THIS PRODUCT TO THE STORE OR DEALER
PLEASE CALL OUR CUSTOMER SERVICE DEPT. AT: 1-888-499-1925
InterVac Design Corp.
2939 SW 42nd Avenue, Palm City, FL 34990
Phone 772-463-1400 • USA & Canada toll free 888-499-1925
the "C” holes. 4 www.intervacdesign.com • e-mail: intervac@intervacdesign.com
A
C
B
4

top view of VacPort
24 Volt
Pigtail Wire
LED
Circuit Board
2) pipe coupling
3
w
co
p
O
Connecting the VacPort to your Central Vacuum
ELECTRICAL REQUIREMENTS:
The low voltage Control Wires from your Central Vacuum Cleaner have mostly an
output of 24volt AC.
Note: some Central Vacuums have 24volt DC output. If your vacuum does not start ---
just reverse the 2 wires at the wire nuts. (Reverse the polarity).
Maintenance:
After a year or two the low voltage contacts in the back of the unit might be accumulating
some dust. Flip the door quickly up and down a few times, to shake the dust off.
Or remove the VacPort and clean around the steel rod and the circuit board.
Installation: into a kitchen cabinet kickboard or room baseboard, flush with the floor.
IMPORTANT:
DISCONNECT THE POWER TO THE CENTRAL VACUUM BEFORE INSTALLING
WITH TRIM-PLATE INSTALLED:
1) Your VacPort is supplied with a Trim-Plate in case you need more height, than the
2-1/2” to reach with your hand into the cut-out. It is also used as a template to mark the
cut-out. See STEP1. The minimum opening is 6-1/8” wide x 2-1/2” height.
2) After cutting the hole, STEP2, attach the Trim-Plate with the 2 pan head screws in one
1) elbow with
pipe coupling
) Press-fit flex-hose
ith threaded
upling #D900 into
ipe coupling.
r hose clamp
of the outer holes on each side, see STEP3.
3) Connect the VacPort to your central vacuum with 2” diameter flex-hose.
WITHOUT TRIM-PLATE INSTALLED:
4) If you do not need the Trim-Plate, attach the VacPort directly to the wall with the 2 flat
head screws, see STEP4. Keep Trim-Plate for future reference.
5) See next page for wire connections.
2
Please Note: The connection to the VacPort should be flexible enough so that you can
pull the FLEXIBLE HOSE and central vacuums Low Voltage Wires out of the wall
and connect both to the VacPort outside the wall.
You have 3 option to connect to the VacPort:
1) with PVC cement, glue the elbow to the pipe coupling and then to the VacPort, the other
end of the elbow connects to a black threaded pipe coupling. Do not glue this coupling,
just twist and press fit into elbow, check if you still can slide the VacPort with the
flex-hose attached in or out of the cut-out.
2) with pipe coupling, push black threaded coupling directly into pipe coupling.
3) with the flexible hose, you can either connect the flexible hose directly with a hose
clamp to the VacPort’s pipe or connect with the black threaded coupling to the pipe
coupling (2)
Connect the 24volt wires from the Central Vacuum to the VacPort.
Leave slack in the wires at the connections.
Model A900
with LED
3
This manual suits for next models
1