6MSK-101| Installation instructions v1.0 FEB 2018 |msk-101_instructions_en_wo v1.0|© 2017-2018 Inxpect SpA
Get to know MSK-101
Figure 4- Sensor directed towards the left.
Field of vision
Range of the field with horizontal
sensor direction (volumetric)
Figure 5- Seen from top view.
Range of the field with vertical
sensor direction (barrier)
Figure 6- Seen from top view.
Examples of the field of vision
with horizontal sensor direction
(volumetric)
NOTICE: the detection start and end values do not
guarantee detection of a standing person. The
reported values may slightly vary based on the
installation conditions. Check the effective
monitored area through the application during
configuration.
Note: only some heights are reported, but every
intermediate value is allowed and guarantees optimum
performance.
Height
(h)
Inclination
(α)
Start detection
(s1)
End detection
(s2)
m ft m ft m ft
1 3.2 0° 0.5 1.6 20 65
1.5 4.9 0° 0.5 1.6 20 65
2 6.5 -15° 2.5 8.2 16 52
2 6.5 -30° 2 6.5 10 32
2.5 8.2 -15° 3 9.8 17 55
2.5 8.2 -30° 2.5 8.2 10 32
2.5 8.2 -45° 2 6.5 6.5 21
3 10 -30° 2.5 8.2 10 32
3 10 -45° 2 6.5 6.5 21
Examples of the field of vision
with vertical sensor direction
(barrier)
NOTICE: the detection start and end values do not
guarantee detection of a standing person. The
reported values may slightly vary based on the
installation conditions. Check the effective
monitored area through the application during
configuration.
Note: only some heights are reported, but every
intermediate value is allowed and guarantees optimum
performance.
Height
(h)
Inclination
(α)
Start detection
(s1)
End detection
(s2)
m ft m ft m ft
1 3.2 0° 0.5 1.6 20 65
1.5 4.9 0° 0.5 1.6 20 65
2 6.5 -15° 2 6.5 20 65
2 6.5 -30° 1 3.2 16 52.5
2.5 8.2 -15° 2 6.5 20 65