ipf electronic SL450824 User manual

MANUAL [SL450824]• Subject to alteration! Version: 29.03.2019
ipf electronic gmbh • Kalver Straße 25 - 27 • 58515 Lüdenscheid - Germany
│
Tel +49 2351 9365-0 • Fax +49 2351 9365-19
│
1
info@ipf-electronic.com • www.ipf-electronic.com
SL450824
Imonitoring device for air and gases
Iintegrated electronics
ILED balancing indicator
Istainless steel coated measuring system
Irobust PA housing
Iscrew thread G ½
Ipressure resistance up to 30bar
IM12-connector
TECHNICAL DATA
operating voltage
24V DC ± 20%
current consumption
current consumption 80mA
switching output
relay output, no
detection range air / gases 0.5 to 30m/s
standby time
10 … 90s
reaction time
2 … 30s
degree of protection IP67 (DIN 40050)
ambient temperature
-20 … +70°C
temperature range of medium
-20 … +80°C
temperature gradient 20°C / min.
pressure resistance
30 bar
material sensor
V4A
material housing
PA
Connection Mounting
Mounting instructions:
When installing the sensor in the flow channel, make sure that the two measuring pins are completely immersed in
the flow. The maximum immersion depth is limited to half the channel diameter.
Flow sensor for air and gases
Pressure resistance up to 30 bar
MANUAL [SL450824]• Subject to alteration! Version: 16.07.2018
2
ipf electronic gmbh • Kalver Straße 25 - 27 • 58515 Lüdenscheid - Germany
│
Tel +49 2351 9365-0 • Fax +49 2351 9365-19
│
info@ipf-electronic.com • www.ipf-electronic.com
Dimensional drawing
Status LEDs:
red set flow value falls below, relay dropped
yellow set flow value reached, relay energized
yellow and green set flow value exceeded, the number of lighting green
LEDs is a measure of the flow reserve
Adjustment
The adjustment of the switching point is done with the potentiometer in the front of the device. Remove the protec-
tive screw. Always carry out the adjustment only when the flow velocity and the medium temperature are stable. The
flow velocity to be monitored must be within the detection range of the flow switch.
MANUAL [SL450824]• Subject to alteration! Version: 29.03.2019
ipf electronic gmbh • Kalver Straße 25 - 27 • 58515 Lüdenscheid - Germany
│
Tel +49 2351 9365-0 • Fax +49 2351 9365-19
│
3
info@ipf-electronic.com • www.ipf-electronic.com
SAFETY WARNING:
Before initial operation, please make sure to follow all safety instructions that may be provided in the product infor-
mation!
Never use these devices in applications where the safety of a person depends on their functionality.

Other ipf electronic Measuring Instrument manuals

ipf electronic MW11 Series User manual

ipf electronic

ipf electronic MW11 Series User manual

ipf electronic MW10 User manual

ipf electronic

ipf electronic MW10 User manual

ipf electronic touchMATRIX BA050100 User manual

ipf electronic

ipf electronic touchMATRIX BA050100 User manual

ipf electronic YT353120 User manual

ipf electronic

ipf electronic YT353120 User manual

ipf electronic SL450824 User manual

ipf electronic

ipf electronic SL450824 User manual

ipf electronic PT169070 User manual

ipf electronic

ipf electronic PT169070 User manual

ipf electronic SS430020 User manual

ipf electronic

ipf electronic SS430020 User manual

ipf electronic touchMATRIX WY050100 User manual

ipf electronic

ipf electronic touchMATRIX WY050100 User manual

Popular Measuring Instrument manuals by other brands

Trace2O METALYSER HM4000 instruction manual

Trace2O

Trace2O METALYSER HM4000 instruction manual

Siemens Ardoptix PT 140 AF4 operating manual

Siemens

Siemens Ardoptix PT 140 AF4 operating manual

Amprobe AM-500 Replacement instructions

Amprobe

Amprobe AM-500 Replacement instructions

Panametrics DewPro MMR31 Installation & operation manual

Panametrics

Panametrics DewPro MMR31 Installation & operation manual

Shark 250 quick start guide

Shark

Shark 250 quick start guide

PCB Piezotronics IMI Sensors 625B61 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI Sensors 625B61 Installation and operating manual

Megger TM1700 Series user manual

Megger

Megger TM1700 Series user manual

Frederiksen 4410.30 manual

Frederiksen

Frederiksen 4410.30 manual

DISAG RM IV operating instructions

DISAG

DISAG RM IV operating instructions

ATAGO PAL-Easy ACID181 instruction manual

ATAGO

ATAGO PAL-Easy ACID181 instruction manual

Kane KANE251 manual

Kane

Kane KANE251 manual

Carel boss micro BMBST00DP0 Hardware guide

Carel

Carel boss micro BMBST00DP0 Hardware guide

LIMIT 7000 operating manual

LIMIT

LIMIT 7000 operating manual

R&S FSWP-B1 user manual

R&S

R&S FSWP-B1 user manual

Hanna Instruments GroLine HI98168 instruction manual

Hanna Instruments

Hanna Instruments GroLine HI98168 instruction manual

DRUCK & TEMPERATUR Leitenberger LR-Cal LTC 100 manual

DRUCK & TEMPERATUR Leitenberger

DRUCK & TEMPERATUR Leitenberger LR-Cal LTC 100 manual

DATEREMOTE CDS-9020 manual

DATEREMOTE

DATEREMOTE CDS-9020 manual

Viavi CAA06M user guide

Viavi

Viavi CAA06M user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.