iReliev iRenew ET-7070 Installation instructions manual

Instruction & Operating Manual
Read Before Using
iReliev™ Strength & Recovery System

iReliev™
Pain Management System
Intended Use
The iReliev™ Strength & Recovery System, model no. ET-7070 is intended for:
For temporary relief of pain associated with sore and aching muscles in the lower back due to strain
from exercise or normal household and work activities. (Choose TENS Modes P1 through P7)
For temporary relief of pain associated with sore and aching muscles in the upper and lower extremities
(arm and/or leg) due to strain from exercise or normal household and work activities.
(Choose TENS Modes P1 through P7)
For symptomatic relief and management of chronic, intractable pain and relief of pain associated
with arthritis. (Choose TENS Mode P8)
For use by healthy adults for the stimulation of healthy muscles in order to improve or facilitate
muscle performance. (Choose EMS Modes P1 through P6)
SAFETY INSTRUCTIONS: CONTRAINDICATIONS & WARNINGS………......................1
WARNINGS & PRECAUTIONS……………………………………………........................... 1-4
PACKAGE CONTENTS..………………………………………………………....................... 5
STEP BY STEP OPERATION GUIDE FOR TREATMENT…………….……..................... 6
Preparing Skin for Running a Session…………………………………….................. 6
Inserting 3 AAA Batteries..……………………………………………………............... 6
Placement of the Pads for TENS (Treatment of Pain)…………………................... 7
Placement of Pads for EMS (Muscle Stimulation) ………………………….............. 9
Turning ON the Device.………………………………………………………................ 10
Turning OFF the Device .………………………………….………………................... 10
Selecting the Treatment Time.………………………………………………................ 10
Selecting the Program.…………………………………………………………............. 11
Selecting the Therapy Intensity Level.………………………………………............... 14
SPECIAL FEATURES.…………………………………………………………........................ 15
CARE AND MAINTENANCE…………………………………………………......................... 16
TROUBLESHOOTING.………..………………………………………………........................ 17
ET-7070 STIMULATOR TECHNICAL SPECIFICATIONS…..............................................18
WARRANTY………………………………………………….................................................. 22
Table of Contents

Safety Instructions
Read instruction manual before operation. Be sure to comply with all “CAUTIONS” and “WARNINGS”
in the manual. Failure to follow instructions can cause harm to user or device.
Please read the following information carefully before using iReliev® Strength & Recovery System.
What is TENS?
The more precise term is Transcutaneous (meaning “through the skin”) Electrical Nerve Stimulation
(TENS). A TENS unit is an electrically powered device used to apply an electrical current to electrodes on
a patient’s skin to relief pain associated with sore or aching muscles.
What is EMS?
EMS stands for Electrical Muscle Stimulation. An EMS device is used to stimulate healthy muscles in
order to improve muscle performance.
Warnings for proper use and safety
DonotusethisSystemifyouhaveacardiacpacemaker,implanteddebrillator(s)orany
other implanted metallic or electronic device. Such use could cause electric shock, burns,
electrical interference, or death.
Do not use this System if you have undiagnosed chronic pain.
Do not use if you are pregnant. The safety of electronic muscle stimulation over the
pregnant uterus has not been established.
Do not use if you suffer from cancer. The effects of electronic stimulation on cancerous
tissue are unknown.
Do not use if you are under medical supervision for cognitive dysfunction as you may not
be able to comply with safety instructions.
Do not use if the unit is in close proximity to shortwave or microwave diathermy equipment
or you are connected to high-frequency surgical equipment, because of risk of device
interference.
Do not wear the device or place electrode pads over areas at which drugs/medicines are
administered (short-term or long-term) by injection (e.g. hormone treatment).
Do not use if you have epilepsy.
Do not use if you have recently undergone a surgical procedure.
Do not use following acute trauma or fracture in case of critical ischemia of the limbs.
WARNING AND PRECAUTIONS
If you are under the care of a Physician, consult with your Physician before using this System.
The long-term effects of this System are not known.
Do not place the pads on or close to your heart.
Do not place the pads around or close to your neck. Do not apply stimulation over the neck. Severe
spasm of the muscles may occur and the contractions may be strong enough to close the airway or
causedifcultyinbreathing.Stimulationovertheneckcouldalsohaveadverseeffecthearingorblood
pressure.
1

Do not apply stimulation across the chest because the introduction of electrical current into the chest
may cause rhythm disturbances to the heart.
Do not place the pads on or around your head. The effects of stimulation of the brain are unknown.
Do not use the electrode pads over or close to sores.
Do not place the electrode pads on the front or sides of the neck across or through the heart (one pad
on the front of the chest and one on the back), in the genital region, or on the head, because of the risk
of stimulating inappropriate muscles and organs.
Donotplacetheelectrodepadsoveranyrecentscars,brokenorinamedareasofinfectionor
susceptibility to acne, thrombosis or other vascular problems (e.g. varicose veins), or any part of the
body where feeling is limited.
Do not place the electrode pads over areas of injury or restricted movement (e.g. fractures or sprains).
Do not use while sleeping.
Do not use if you feel numbness
Do not use in or close to water.
Do not apply stimulation across the chest because the introduction of electrical current into the chest
may cause rhythm disturbances to the heart, which could be lethal.
Do not use the pads over or close to cancerous lesions.
Use the electrode pads only on normal, healthy, clean and dry skin. Do not use the electrode pads on
openwoundsorrashes,oroverswollen,red,infectedorinamedskin.
If you have ever had back surgery, consult your Physician before using this System.
You must position the pads and operation the unit ONLY as indicated in this manual.
Avoid areas in injury or restricted movement ( e.g. fractures or sprains)
Avoid placing the pads over metal implants.
Do not use in the bath or shower, or in an environment of elevated humidity
(e.g. Sauna, hydrotherapy, etc).
Wait before using this system until:
At least 6 weeks after the birth of your baby (you must consult your doctor before use).
OnemonthafteranIUDcontraceptivedevice(e.g.coil)hasbeentted(youmustconsultyourdoctor
before use).
At least 3 months after having a caesarean section (you must consult your doctor before use).
Theheavydaysofyourperiodhavenished,becausevigorousabdominalexerciseisnotrecommended
at this time.
Precautions
ReadOperatingandInstructionManualbeforeusingthisSystemforthersttime.
Keep this manual available whenever you use the System.
The System is intended for personal use on healthy adult muscle only.
The safety of using the System during pregnancy or birth has not been established.
The effectiveness of the System depends greatly on a person’s individual physical condition. It may not
always be effective for every user.
The safety of neuromuscular stimulation during pregnancy has not been established.
Use caution when and/or if:
User has skin areas that lack normal sensation.
- Following surgical procedures if muscle contractions might impede the healing process.
- Over a menstruating or pregnant uterus.
- There is a tendency to hemorrhage following acute trauma or fracture.
Place electrodes in accordance with illustrations in the User Manual.
This unit should not be used while driving, operating machinery or during any activity in which involuntary
muscle contractions may place the user at undue risk of injury.
Some users may experience skin irritation or hypersensitivity due to the electrical stimulation or the
conductive medium.
Keep the stimulator out of the reach of children.
2

Application of moderate heat (thermal wrap) to muscles as well as moistening skin prior to
treatmentimprovestreatmentefcacy;useofcoldpacksontreatedmusclesaftertreatmentislikewise
recommended.
This unit should only be used with the leads, electrodes and accessories provided by the manufacturer.
The device is not intended for medical use, for the treatment of any medical condition or for any
permanent physical changes.
Contact ExcelHealth Inc., or an authorized dealer, if your unit is not working correctly. Do not use in the
meantime. Replace batteries.
An effective session should not cause discomfort.
Forrsttimeusers,musclestimulationcanbeanunusualsensation.Werecommendthatyoubegin
in a seated position with low stimulation intensity settings
to familiarize yourself with the sensation before
progressing to higher intensity settings.
The leads and electrodes pads must not be connected to
other objects.
Do not over exert yourself while using muscle stimulation.
Any workout should be at a comfortable level for you.
Do not place pads over jewelry or body piercings.
Startallsessionsinasittingposition(g.a).Ifnecessary,
secure the limb(s) to be exercised before using this device.
Use Caution and consult your Physician before using System if any of the following conditions
apply to you:
You have any serious illness or injury not mentioned in this guide.
You have recently undergone a surgical procedure.
You take insulin for diabetes.
You use the unit as part of a rehabilitation program.
If you have suspected or diagnosed heart problem.
If you have suspected or diagnosed epilepsy.
If you have a tendency to bleed internally following an injury.
If you recently had surgery, or have ever had surgery on your back.
If areas of skin lack normal sensations, such as skin that tingles or is numb.
During menstruation or during pregnancy.
Some people may feel skin irritation or experience a very sensitive feeling in the skin due to electrical
stimulation. If this occurs, stop using your System and consult your Physician.
If skin under one of more pads feels irritated after using the stimulator for a long period of time, use the
stimulator for a shorter period of time.
Minor redness at stimulation placement is a normal skin reaction. It is not considered as skin irritation,
and it will normally disappear within 30 minutes after the electrodes are removed. If the redness does
not disappear after 30 minutes from the removal of electrodes, do not use the stimulator again until after
the excessive redness has disappeared.
Turn off the stimulator if the stimulation feels unpleasant or does not provide pain relief.
Keep your System out of the reach of children.
Use your stimulator only with the pads, snap cables and accessories recommended by the manufacture.
Do not use this System when driving, operating machinery or when swimming.
Before removing the belt and pads, be sure to power off device to avoid unpleasant stimulation.
3
g.a

4
After strenuous exercises or exertion:
Always use lower intensity to avoid muscle fatigue.
Important:
Do not use your unit at the same time as any other device which transfers an electrical current into the
body (e.g. another muscle stimulator).
Cease using your unit if you are feeling light headed or faint. Consult a Doctor if this happens.
Do not touch the pads or metal studs while the unit is switched on.
Do not use unit if you are wearing a belly button ring. Remove ring before session.
Note: If you are in any doubt about using device for any reason, please consult your doctor before
Electrode Pad Precautions
To reposition the pads during a session, always pause the program currently running, reposition the pads
as directed on page 7 and page 9 and then restart the program again.
Only use iReliev™ brand electrode pads with your device. Any others many not be compatible with your
unit and could degrade the minimum safety levels.
The electrode pads are for single person use only.
Do not plunge the pads into water.
Do not apply solvents of any kind to the pads.
Always ensure the unit is OFF before removing the pads.
Applythewholesurfaceofthepadsrmlytotheskin.Donotusepadswhichdonotadhereproperlyto
the skin.
If your skin is red under the pad after a session, do not start another session in the same area until your
redness has completed disappeared.
Adverse Reactions
You may experience skin irritation and burns beneath the stimulation electrodes applied to your skin.
You may experience headache and other painful sensations during or following the application of electrical
stimulation near your eyes and to your head and face.
You should stop using the device and should consult with your physician if you experience adverse
reactions from the device.
Conditions that may affect your System
Since the stimulator is a battery-operated electronic System, its output performance and safety may be
affected greatly in extreme humidity. Therefore, it is very important to keep the stimulator dry to ensure the
safety and performance of the stimulator.

ABOUT THE iReliev™ DEVICE
PACKAGE CONTENTS
1. ET-7070 iReliev™ Strength &
Recovery Device
2. 1 clip holder
3. Electrodes CM-5050, sized
2” x 2”, 4 pieces/pack
4. 3 AAA batteries
5. 2 lead wires1 storage bag
6. ET-7272 size 130x90 mm
2 pcs/pack
1. Power on / adjust / increase setting key
2. Power off / adjust / decrease setting key
3. CH1 key
4. CH2 key
5. Therapy Time/Mode/Program selection Key
6. Program number
7. Therapy time remaining
8. CH1 intensity level
9. CH2 intensity level
10. Lock status indicator
11. Battery status indicator
12. Batteries compartment
13. Battery cover
5
7. Optional Conductive Back Wrap
Accessory, Model # ET-1515

STEP BY STEP OPERATION GUIDE FOR TREATMENT
Preparing the Skin for Running a Session
Proper preparation of the skin covered by the electrodes allows more stimulation to reach targeted tissues,
prolongs electrode life, and reduces the risk of skin irritation. After connecting the lead wire(s) to the
stimulator, use the following steps to prepare your skin at the electrode placement sites:
1. Determine the placement sites for the electrodes.
2. Wash the area with mild soap and water (do not use alcohol). Rinse and dry thoroughly.
3. Trim excess body hair from the area with scissors (do not shave).
4. Optionally, apply skin prep to the area to form a protective barrier on your skin. Apply, let dry, and
apply electrode as directed. This will both reduce the chance of skin irritation and extend the life of your
electrodes.
5. When removing electrodes, always remove by pulling in the direction of hair growth.
6. It may be helpful to apply skin lotion on electrode placement area when not wearing electrodes.
Inserting/Changing the Batteries
1. Open the battery compartment at the back of the device by pushing the battery cover labelled “Open”
downward(thisareafeaturesraisedmarksforeasyidentication).
2. Insert3AAA(1.5V)batteriesinthebatterycompartment;makesuretomatchupthesymbols(+/–).
3. Close the battery cover by carefully placing the stud into the slot in the rear area and sliding it upward,
applying slight pressure.
4. Follow the same procedure when replacing the battery at a later date.
▲Note:forimportantprecautionsregardingthebatteries,pleasebeinformed:
• Alwaysuseonly3x1.5V(AAA)batteries.
• Keepawayfromchildren.
• Donotrecharge.
• Donotshort-circuit.
• Donotthrowintoare.
• Pleaserecycle.Donotdisposeofoldbatterieswithyourhouseholdwaste;disposeofthemsafelyat
your recycling centre or business where the batteries were purchased.
NOTE: the batteries should last between 30 and 60 application depending on
stimulation times and frequencies.
6

Connecting the Cable to The Device
1. Connecting the lead wire to the electrodes before
applying to the Skin.
2. Insert the connector plugs into sockets at the top of unit.
Note: 1. Recommended Electrodes size 5” x 3.5”, for larger (e.g. leg muscles, lower back), and
Size 2” x 2: for smaller areas such as forearm muscles etc.
Placement of the Electrode Pads for TENS (Treatment of Pain)
7

2. You may need help placing the Electrode Pads onto hard to reach areas (lower & upper back).
Or,
3. You could use Optional Conductive Back Wrap (ET-1515) for temporary relief of pain associated with
sore and aching muscles in the lower back.
8
For the Conductive Back Wrap, additional pads, and replacement parts, visit www.iReliev.com
Note for EMS users: The belt can be used for your back or your stomach.
ffStep1.Removetheprotectivelmfromsidesofpads.
Step 2. Position the electrodes on the area of the body. Adjust the belt width and putting on the belt.
Step 3. Insert the connector plugs into sockets at the top of unit.

Placement of the Electrode Pads for EMS
1. Connecting the lead wire to the electrodes before applying
them to the Skin. Use the large Electrode Pads for EMS.
2. The pad placement chart hereafter illustrates the correct
placement of the pads for a selection of target muscles.
9
Note: Always start with a low intensity level, increase gradually. You may use any of the modes for EMS.

Turning On the Device
1.PressandholdtheON+buttonforone(1)secondtoturnon
the device.
2. The most recently selected treatment time and program will
ashwhentheunitisturnedon.
▲Note : Do not turn the unit on until all electrodes and lead
wires are properly attached.
▲Note : When stimulating the muscles of the arms or legs in the
EMS Mode, bear in mind that the muscle contraction may
cause involuntary limb movement which could cause injury to
you or others. Always ensure the limb is secured to prevent
movement.
Turning Off the Device
1. The device turns off automatically after the therapy session
time has elapsed.
2. To turn the unit off manually, press the OFF- button for three
(3) seconds. The display will go blank and the device will turn
off.
3. In an emergency you may also pull the connector(s) from the
device and then remove the belt.
▲Note : To prevent unpleasant electric shocks, never remove
the Electrodes while it is still turned on.
Selecting the Treatment Time
1.PressMODE.Thepreset(default)treatmenttimewillashonthedisplay.
2.Toincreaseordecreasethetreatmenttime,pressthebuttonON+(toincrease)orthebuttonOFF–
(to decrease) repeatedly until the desired duration appears on the display.
3. Press MODE again to save your selection. The treatment time you selected will appear on the display the
next time you turn the device on.
▲Note: If you change programs during the course of a therapy session, the treatment time will not reset
unless you manually reset it by performing the steps described above.
10

11
SelectingTENS OR EMS Programs
The device offers 14different pre-set treatment programs for both TENS (P1-P8) and EMS (P1-P6)
modes; the programs differ with respect to varying pulse widths and frequencies.
Choosethe mode that is appropriate to your needs or gives you the greatest pleasure
1. Press MODE after treatment time is set. The preset (default)
therapymodeTENS/EMSwillashonthedisplay.
UseON+orthebuttonOFF–,ifyouwouldliketochangethe
therapy mode.
2. Press Mode again, the numeric number of program is then
ashing.
PressthebuttonON+(toincrease)orthebuttonOFF–(to
decrease) for choice of program of the selected modality.
3. Press MODE again to save your selection. The treatment time
you selected will appear on the display the next time you turn
the device on.
▲Note:Ifyouchangeprogramsduringthecourseofatherapy
session, the treatment time will not reset unless you
Manually reset it by performing the steps described above.

12
For TENS (P1-P8) Programs:
When using any of the 8 programs for pain relief always start with the lowest intensity and gradually
increase the level of intensity until you feel a “tingling” sensation. All programs are different and therefore
feel differently. You may try all 8 programs in the beginning and choose one that feels pleasant. Never
increase the intensity to a level so that it hurts, always stay under the point of discomfort. Start with short
sessions of 5 or 10 minutes until your body gets used to the stimulation.
Program Mode
P1
P2
P3
P4
P5
P6
P7
P8
Potential Benets You should feel
For temporary relief of pain
associated with sore and aching
muscles in the lower back due
to strain from exercise or normal
household and work activities.
For temporary relief of pain
associated with sore and aching
muscles in the upper and lower
extremities ( arm and/or leg) due
to strain from exercise or normal
household and work activities.
For symptomatic relief and
management of chronic,
intractable pain and relief of pain
associated with arthritis.
Continuous comfortable tingling. The underlying pain
should decrease gradually after treatment.
Comfortable pulsing sensation.
The underlying pain should decrease almost immediately.
Comfortable pulsing sensation. The underlying pain
should decrease almost immediately.
Variable comfortable tingling and pulsing sensation
(sensation should appear to come in waves).
Pain should ease and there should be relief after treatment.
Variable comfortable mild tingling sensation (sensation will
appear to come in waves).
Variable comfortable pulsing and pumping action (action
will appear to come in waves).
Variable comfortable tingling and pumping action (action
should appear to come in waves).
Variable comfortable tingling and pulsing sensation
(sensation should appear to come in waves).
Pain should ease and there should be relief after treatment.
Program
P1 80mA 260uS 15Hz Constant
Modulated
Constant
Modulated
Modulated
Modulated
Modulated
Cycle
260uS 60Hz
260uS 60Hz
260-156uS 2 - 60Hz
260-156uS 60Hz
260uS 7 <->60Hz
260-156uS 60Hz
210uS 2.45~245 Hz
80mA
80mA
80mA
80mA
80mA
80mA
80mA
P2
P3
P4
P5
P6
P7
P8
Max. Phase
duration Rate Function
Mode
Allelectricalspecication±20%
TENS P1 - P8 Potential Benets
TENS P1 - P8 Technical Attributes

13
For EMS (P1-P6) programs:
When using the device for muscle stimulation (EMS) any of the 6 programs may be used. The intent is to
cause a muscle to contract, and then release. All 6 programs will achieve contraction and vary mainly by
the rate and duration of the contractions. As with any exercise regiment, start out slowly with low intensity
levels for a warm-up (5~10min). You may increase intensity level and treatment time as you progress with
yourmuscleperformance.Usethedeviceregularlyoveralongerperiodoftimeastomaintainthebenet
you may have gained during “exercise”.
Mode / Exercise
Program
P1
Exercise Preparation
P2
Active Recovery
P3
Active Recovery
P4
Active Recovery
P5
Build Endurance
P6
Muscle Strengthening
What you Should Feel &
PotentialBenets
This program gently warms up the
musclespriortoexercise;itfeelslikea
rhythmic massage.
This program produces muscle twitches
at very low frequency and it feels like a
tapping massage, for muscle recovery
from fatigue and becoming more relaxed
with reduced stiffness.
This program is similar to P2, except
that the muscle twitch rate slows down
during the session. It feels like a tapping
massage, but softer than P2.
This program activates the muscle in a
short contraction/relaxation cycle.
It feels like a kneading massage,
smother than P2/P3.
This program uses a low frequency pulse
trainwhichfavoursslowtwitchbers,
for developing aerobic capacity
and capillary supply. It improves
fatigue resistance during long duration
moderate intensity exercise.
This program uses a pulse frequency
appropriatetofasttwitchmusclebers.
It improves their anaerobic capacity and
is used for improving maximum muscle
strength.
Suggestion
Increase the intensity until you get a
strong but comfortable muscle movement,
10 min/duration.
Use it after intense exercise to promote
recovery and relaxation, 30 min/duration.
Use it after intense exercise to promote
recovery and relaxation, 20 min/duration.
Use it after intense exercise to promote
recovery and relaxation, 20 min/duration.
The exercise comprises an alternating
sequence of work and rest phases lasting
several seconds. Increase the intensity until
you get a strong and deep muscle contraction.
Do not exceed your comfort level,
20min/duration.
The exercise comprises a sequence of work
phases separated longer relaxation phases.
Increase the stimulation intensity until you get
a strong and deep contraction. Do not exceed
your comfort level, 20 min./Duration.
Program
Pulse
Width
(uS)
Ramp up
(sec)
Hold on
(sec)
Ramp down
(sec)
Off Time
(sec)
P1 300 - 2 - 1
P5 200 2 6 2 1
P2 200 - - - -
P6 300 2 5 3 10
P3 300 - - - -
P4 200 - 2 - 1
Pulse rate
(Hz)
40-99
4-20
4
50
5
99
Allelectricalspecication±20%
EMS P1-P6 Potential Benets
EMS P1-P6 Technical Attributes

Selecting the Therapy Intensity Level
This device offer a maximum of 25 intensity levels.
The design of the device does not allow the user to modify any of the electrical parameters. The only
adjustment that can be made is the electrical intensity which is set to a predetermined maximum current
that is well with in safe limits. The intensity of the electrical current determines the number of working
bersinthestimulatedmuscles.Thelowerthecurrentintensitythelowerthenumberofworkingbersin
themuscle.Thehigherthecurrentintensitythegreaterthenumberofworkingbersinthemuscle.
If using the device for help with temporary relief of pain associated with sore and aching muscles then you
willndthatsettingthecurrentintensitytoyourowncomfortableandpleasinglevelwillgiveyoumuch
satisfaction. This level is different for each user so adjusts slowly and accordingly.
If you desire to stimulate healthy muscles (EMS) in order to improve and facilitate muscle performance
thenyouwanttoachieveasignicantnumberofworkingbers.Yourequireaminimumintensity(approx.
30mA) to accomplish this. This can be achieved relatively quickly (2 to 3 sessions) by progressively
increasing the intensity during the session. Once this threshold is reached, continue to progressively
increase the current intensity making the session more effective.
1. Intensity is adjustable according to the channel selected.
Select the channel you wish to adjust by pressing CH1 or
CH2.“CH1”or“CH2”willashonthedisplay.
2.Toincreaseordecreasetheintensity,pressON+(to
increase)orOFF–(todecrease)repeatedlyuntilthedesired
intensitylevelashesonthedisplay.
▲Note:Youwillfeeltheintensityincreaseordecreaseasyou
select the intensity level. You can use this as a guide
to select a level that is comfortable for you.
▲Note:Ifyouchangetherapymode/programduringthe
course of a therapy session, the intensity level will
reset to “0” showing on the screen, for safety reason.
3. Press MODE to save your selection.
▲Note:Itissuggestedthattreatmentfrequencyis3times
per day
14
Never set intensity so that the stimulation becomes extremely uncomfortable.

15
SPECIAL FEATURES
Treatment Time
The device offers 12 preset times: 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55 and 60 minutes.
Time will countdown on the display in 1-minute increments for the duration of your session.
The device turns off automatically when the therapy time has elapsed.
The most recently set therapy time is stored.
If you alter the program mode during your therapy, the therapy time won’t restart, unless you reset
the therapy time.
The last treatment program you used will appear on the display, when you turn on the device.
Tochangetheprogram,pressON+orOFF–repeatedlyuntilthedesiredprogramappearsonthedisplay.
Press MODE to save your selection. The program you selected will appear on the display the next time
you turn on the program.
Lock Function
PressandholdtheON+andOFF–keyssimultaneouslyfor1secondtolock/unlockthedevice.
The Lock Function prevents accidental intensity changes when buttons are “bumped”.
Automatic Shut off
The device automatically turns off when no button is pressed for 60 seconds.
The device automatically turns off when the time for your therapy session has elapsed.
Intensity Level Reset
For your safety and comfort, the intensity level will reset to ”0” each time the device turns off and after the
therapy session has elapsed.
The treatment will discontinue if the electrodes are not properly placed well, and/or any entry for changing
the mode setting during therapy session, it shall initiate to lowest intensity level, showing “0” on the screen.
Low Battery Status Indicator
The battery status indicator will light whenever the battery is low. This means that soon you have to replace
the batteries.
The batteries should last between 30 and 60 applications depending on stimulation times and frequencies.

16
CARE AND MAINTENANCE
Stimulator
The stimulator may be wiped clean with a small amount of soapy water on a clean cloth. Do not submerge
the stimulator in liquids or expose it to large amounts of water.
Never use aggressive cleaning products of stiff brushes to clean the device.
Remove the batter before cleaning the device.
Do not use the device again until it is completely dry.
Do not expose the device to direct sunlight and protect it from dirt and moisture.
Cables
Disconnect the cables from the stimulator and electrodes.
Do not pull on the cables, but on the connectors attached to the ends of the cables.
Store the stimulator with the cables in a clean, dry place.
Electrode
The electrode pads are disposable and use an adhesive that will dry after prolonged usage or storage. Pads
should be replaced when they lose their adhesive quality, or you sense a change in stimulation sensation.
If you’re in doubt about the integrity of the pads, order fresh pads please order online at www.iReliev.com or
contact authorized distributor(s).
How to Store Your System
1. Store your System at room temperature in a dry place, out of the reach of children.
2. If the stimulator will not be used for more than a week, remove the battery from the stimulator.

17
TROUBLE SHOOTING
Alwayschecktheunitandaccessoriesbeforeusetopreventdamageanddefects;thesearesomeofthe
simple checks:
1.Makesurethebatteryhassufcientchargeandisnotcorroded.
2.Makesurethecablesttightlyintotheconnectionsocketsofthedevice.Thetablebelowshowssome
common defects. If you cannot remedy the defects as described, contact your unit provider if it is not
possible to remedy in the manner described.
Defect
The device does not
turn on
The unit does not
turn on even though
new batteries have
been inserted
The device turns on
and then off again
The device turns on,
but does not generate
electric pulses
Cause
No battery or bad battery
Battery not inserted
properly
Cable broken
Battery life expired
Cable not connected
Properly
Treatment time has
Expired
Remedy
Replace battery
Contact your distributor or manufacture
Call 1 406.672.6066
Insert battery
again Replace battery
Replace cable
Replace battery
Connect cable properly
Switch unit to the OFF
Position and switch back on.

ET-7070 STIMULATOR TECHNICAL SPECIFICATIONS
Channel: Dual, isolated between channels.
PulseAmplitude: Adjustable0–80mApeakinto500Ωloadeachchannel;
RMSV at 3.5 V (max.), RMSA at 1.3mA (max.)
Pulse Rate: As pre-programming operation mode.
Pulse Width: As pre-programming operation mode.
Timer: 5~60 min. selectable.
LCD: Shows modes, pulse rate, pulse width, timer, CH1/CH2, intensity level.
Wave Form: Symmetrical Bi-Phasic square pulse.
Max Charge per Pulse: 20.8 micro-coulombs maximum.
**Allelectricalspecicationsare±20%at500Ωload.
OperatingConditions: +50°F(10C°)to+104°(40C°),40-90%max.Relativehumidity
Transportation +14°F(-10C°)to+140°(60C°),30-95%max.Relativehumidity
& Storage Condition:
Weight: 75 g (battery included)
Dimensions: 90 x 52.5x19.38 mm
Power Source: 3 x AAA / 4.5 Volt batteries
(i) There are a number of technical symbols on your unit explained as follows:
This symbols means “ Serial number “
This symbols means “ Attention, consult the accompanying documents”
This symbols means “ Manufacturer “
ThissymbolmeanstypeBFequipment;thisdeviceoffersprotectionagainstelectricalshockby
standard compliance to leakage currents of electrode pad.
This device shall be disposed in accordance with national laws after their useful lives
(ii) there is a label on the package of electrode that explains as follows:
This symbol means “used before”, represent as “YYYY-MM”
(for year and month).
18
Other manuals for iRenew ET-7070
3
Table of contents
Other iReliev Massager manuals