ISIC DuraPANEL 24 User manual

User Manual
DuraPANEL Series
DuraPANEL 24”
DuraPANEL 26”

Disclaimer
ISIC A/S makes no representation or warranties with respect to the contents or use of this
manual, and specifically disclaims any express or implied warranties of merchantability or
fitness for any particular purpose. Further, ISIC A/S reserves the right to revise this
publication and to make changes to its content at any time, without obligation to notify any
person or entity of such revisions or changes.
Image sticking: If the monitor is operated with static images (logo’s etc) it will inevitably
lead to images sticking on the display (like on old CRT’s).
FCC Warning
Computing devices and peripherals generate and radiate radio frequency energy, and if not
installed and used in accordance with the instructions advised by ISIC A/S, it may cause
interference to radio communication.
The DuraPANEL series, manufactured by ISIC A/S, is designed to comply with the emerging
generic EEC standards, that cover applications in maritime environment.
Classification
The monitor is classified as “protected from the weather” according to IEC 60945 ed.4 (former
class b).
Approvals
Approval according to IACS E10 ed. 6 and IEC 60945 ed. 4, Maritime navigation and radio
communication equipment and systems – General requirements.
ISIC A/S is complying with the WEEE directive within the European Union, stating that
electronic and electric products must be collected separately.
Products are marked according to the directive.
Copyright 2014 ISIC A/S
ISIC PN: 07354-000 rev. A
ISIC A/S
Edwin Rahrsvej 54
DK-8220 Brabrand
Denmark
Phone: +45 70 20 70 77
Fax: +45 70 20 79 76
Web: http://www.isic-systems.com
User Reference Manual – DuraPANEL series
PN: 07354-000 Rev A Page 2

Table of Contents
1FEATURES ............................................................................................................. 4
2GENERAL CONSIDERATIONS ON INSTALLATION AND OPERATION .......................5
3DURAPANEL CONNECTIONS .................................................................................. 6
4DURAPANEL FRONT PANEL CONTROLS (ECDIS AND RADAR) ................................ 7
5CONNECTOR PIN-OUT ........................................................................................... 8
6TECHNICAL SPECIFICATIONS DURAPANEL 24”..................................................... 9
7TECHNICAL SPECIFICATIONS DURAPANEL 26”................................................... 10
8MECHANICAL OUTLINE DURAPANEL 24”............................................................. 11
9MECHANICAL OUTLINE DURAPANEL 26”............................................................. 12
10 DURA COMMUNICATION PROTOCOL ................................................................... 13
11 COMPASS SAFE DISTANCE .................................................................................. 13
12 POWER CONSUMPTION....................................................................................... 13
13 IN RUSH CURRENT.............................................................................................. 13
14 TROUBLESHOOTING............................................................................................ 14
15 SERVICING THE UNIT ......................................................................................... 14
16 ISIC INFO / SUPPORT......................................................................................... 15
17 REVISION HISTORY ............................................................................................ 16
18 APPENDIX A: PIXEL POLICY................................................................................ 17
19 APPENDIX C: DECLARATION OF CONFORMITY.................................................... 20
User Reference Manual – DuraPANEL series
PN: 07354-000 Rev A Page 3

1Features
Congratulations with your purchase of a DuraPANEL. This short form manual is designed to get
you started working with your new DuraPANEL.
The DuraPANEL series of Panel Computers are all designed for the demanding operating
conditions at sea.
The DuraPANEL series are tested for full compliance to marine-standards IACS E10 and IEC
60945.
The DuraPANEL comes with excellent brightness and contrast levels that, together with wide
viewing angles, ensure a good readability thus making it very eye-friendly. For the best picture
quality, always use a double shielded DVI or VGA cable with ferrites, like the one supplied with
the unit.
User Reference Manual – DuraPANEL series
PN: 07354-000 Rev A Page 4

2General considerations on Installation and
Operation
The DuraPANEL is designed to work at conditions according to IEC 60945. However, keeping
the temperature and vibration level at a minimum will extend the life time of the product. ISIC
recommend operating this product at normal room temperature (20-25 °C), with the lowest
level of vibration and humidity.
Installation of the DuraPANEL
In order to obtain the best possible operating conditions, please note the following precautions.
-When installing the DuraPANEL allways use original or identical fittings.
-
-Room for cooling.
When designing the cabinet/console for the DuraPANEL, please ensure that air can
flow freely around the cabinet, in order to avoid any unnecessary rise in
temperature. If it is not possible to have an adequate natural airflow, use a fan to
force the airflow to be higher.
-Mounting positions
To obtain adequate cooling by convection ISIC recommends that the DuraPANEL is
mounted at least 30 degrees from horizontal. If this is not possible, forced cooling
must be applied directly to the unit in order not to overheat it.
-Sunlight
Avoid direct sunlight to keep temperature low and by that improve lifetime.
User Reference Manual – DuraPANEL series
PN: 07354-000 Rev A Page 5

3DuraPANEL connections
Below is a view of optional connections to the monitor. The default inputs are: power, RS-
232, DVI and VGA.
3.1 DuraPANEL24 connections:
3.2 DuraPANEL26 connections:
DP
HDMI
USB 3.0 x 4
LAN1
POWER DC
POWER AC
LAN2
LINE OUT
MIC IN
RS232
DP
HDMI
USB 3.0 x 4
LAN1
POWER DC
POWER AC
LAN2
LINE OUT
MIC IN
RS232
CHASSIS
CHASSIS
User Reference Manual – DuraPANEL series
PN: 07354-000 Rev A Page 6

4DuraPANEL front panel controls (ECDIS and
Radar)
The front panel controls are illuminated and will be dimmed continuously depending on
changing of backlight brightness.
4.1 DuraPANEL front:
STATUS:
This LED will illuminate green when the monitor is powered on and red when the monitor is
powered down. The LED will blink green if no active signal is found.
ECDIS:
When calibrated this LED will illuminate when backlight level is at calibrated setting.
BRILL:
Used to adjust backlight. Pressing UP and DOWN at the same time will restore the backlight
level to the last selected ECDIS mode (day, dusk or night) by the serial link.
PWR:
This key is used to turn the product on or off. Pressing it will turn the power on, while holding
it pressed for 5 seconds will turn the power off. The status light will change from green to red
to indicate it’s powered down.
ECDIS LED
STATUS LED
UP
DOWN
POWER
User Reference Manual – DuraPANEL series
PN: 07354-000 Rev A Page 7

Pin1
Pin1
5Connector pin-out
5.1 RS-232
Pin
RS-232
SUB-D 9-pol male
1
-
2
DuraPANEL TX
3
DuraPANEL RX
4
-
5
GND
6
-
7
-
8
-
9
-
Mating part: SUB-D 9 pole female, Norcomp 172-E09-20201 or equivalent.
5.2 Power input DC (optional)
The nominal input power voltage is 24V (18-36VDC). The input is galvanic isolated and protected against reverse
polarity.
Mating part number: Weidmüller BLZP5.08HC/02/180F
Pin
Power in
1
0VDC
2
24VDC
5.3 Power input ac
L
E
N
Pin1
User Reference Manual – DuraPANEL series
PN: 07354-000 Rev A Page 8

6Technical specifications DuraPANEL 24”
DuraPANEL - General CPU: Intel®Core® i3-4330TE– 2,4 GHz 2 cores, 4 threads (CPUMark 3,224)
Optional Intel®Core i5-4590T 2,0 GHz 4 cores, 4 threads (CPUMark 5,758)
Optional Intel®Core i7-4770TE 2,3 GHz 4 cores, 8 threads (CPUMark 8,800)
Optional Intel
®
Celeron G1820TE 2,2 GHz 2 cores (CPUMark 2,230)
Chipset:
Intel
®
Q87 Chipset
Memory: 4GB DDR3 1333/1600 MHz SODIMM
Up to 16GB DDR3 SODIMM
Hard Disk Drive: 80GB SSD
Optional 120 / 200 / 240… 1600 GB SSD SATA or USB / CF (option)
Video:
External Video out:
Intel® Graphics controller on-CPU
DirectX* 11.2 and OpenGL - 4.3, OpenCL 2.0, Shader Model 5
3 Independent display capable
HDMI and DP video output connectors
Audio:
Mic-in, Line-out, 2 x 3,5mm Minijack
Ethernet: 2 x 10/100/1000 Gbits/s Ethernet LAN on-
board, (RJ45)
1 xIntel© PHY I217LM (VPro)
1x Intel® I210AT
USB:
COM:
4 x USB 3.0 ports plus 6 x USB 2.0 internally available
1x RS232
Expansion Slots: 1 x PCI Express x 4
1 x PCI Express half-size Mini Card Slot
DuraPANEL - Front
Display size:
23,6 inch 16:9 LCD (TFT)
Resolution:
1920 x 1080
Active area:
521 x 293 mm
View angle:
89° (T/B), 89° (L/R) (typical)
Luminance:
250 Cd/m
2
(typical)
Contrast ratio:
3000:1 (typical)
Front glass:
Anti glare Hardness 3H
Touch:
Optional PCAP Multitouch
DuraPANEL - Power Standard:
Automotive: 90-264VAC. 50-60Hz Input
24VDC (18-36VDC)
Optional Dual power, combined AC and DC input
DuraPANEL - Environmental
Operating Temperature:
-15 to 55 °C
Storage Temperature:
-25 to 70 °C
Relative Humidity:
8 to 95 %
DuraPANEL - Approvals
CE Mark:
EN61000-6-2
Marine: IACS E10 Rev. 6 & IEC 60945 Ed. 4
IEC 61174 / IEC 62288 / IEC 62388
Certificates:
MR Certificate
DuraPANEL - Dimensions
Size:
593 (W) x 384,1 (H) x 68mm (D)
Weight:
App. 12 kg.
Bracket:
Desk/ceiling-and wall-bracket (optional extra)
2 page flyer rev. 09.09.2015. Technical specifications are subject to
change without prior notice. For drawing and full technical
User Reference Manual – DuraPANEL series
PN: 07354-000 Rev A Page 9

7Technical specifications DuraPANEL 26”
DuraPANEL - General CPU: Intel®Core® i3-4330TE– 2,4 GHz 2 cores, 4 4hreads (CPUMark 3,224)
Optional Intel®Core i5-4590T 2,0 GHz 4 cores, 4 threads (CPUMark 5,758)
Optional Intel
®
Core i7-4770TE 2,3 GHz 4 cores, 8 threads (CPUMark 8,800)
Chipset:
Optional Intel®Celeron G1820TE 2,2 GHz 2 cores (CPUMark 2,230)
Intel
®
Q87 Chipset
Memory: 4GB DDR3 1333/1600 MHz SODIMM
Up to 16GB DDR3 SODIMM
Hard Disk Drive: 80GB SSD
Optional 120 / 200 / 240… 1600 GB SSD SATA or USB / CF (option)
Video:
External Video out:
Intel® HD Graphics controller on-CPU
DirectX* 11.2 and OpenGL 4.3, OpenCL 2.0, Shader Model 5
3 Independent display capable
HDMI and DP video output connectors
Audio:
Mic-in, Line-out, 2 x 3,5mm Minijack
Ethernet: 2 x 10/100/1000 Gbits/s Ethernet LAN on-
board, (RJ45)
1 xIntel© PHY I217LM (VPro)
1x Intel® I210AT
USB:
COM: 4 x USB 3.0 ports plus 6 x USB 2.0 internally available
1x RS232 internally available
Expansion Slots: 1 x PCI Express x 4
1 x PCI Express half-size Mini Card Slot
DuraPANEL - Front
Display size:
25,5 inch 16:10 LCD (TFT)
Resolution:
1920 x 1200
Active area:
550 x 343.8 mm
View angle:
88° (T/B), 88° (L/R) (typical)
Luminance:
350 Cd/m
2
(typical)
Contrast ratio:
1500:1 (typical)
Front glass:
Anti glare Hardness 3H
Touch:
Optional PCAP Multitouch
DuraPANEL - Power Standard:
Automotive: 90-264VAC. 50-60Hz Input
24VDC (18-36VDC)
Optional Dual power, combined AC and DC input
DuraPANEL - Environmental
Operating Temperature:
-15 to 55 °C
Storage Temperature:
-25 to 70 °C
Relative Humidity:
8 to 95 %
DuraPANEL - Approvals
CE Mark:
EN61000-6-2
Marine: IACS E10 Rev. 6 & IEC 60945 Ed. 4
IEC 61174 / IEC 62288 / IEC 62388
Certificates:
MR Certificate
DuraPANEL - Dimensions
Size:
621 (W) x 435 (H) x 89mm (D)
Weight: App. 16 kg.
Bracket:
Desk/ceiling-and wall-bracket (optional extra)
2 page flyer rev. 09.09.2015. Technical specifications are subject to
change without prior notice. For drawing and full technical
User Reference Manual – DuraPANEL series
PN: 07354-000 Rev A Page 10

8Mechanical outline DuraPANEL 24”
1
1
2
2
3
3
4
4
5
5
6
6
A A
B B
C C
D D
Approved by
Projection method: Drawing size:
Units: mm
Designed by
General tolerances: `0,2
Hole position: `0,1
Angle, straightness and flatness: DS/ISO 2768-H
Scale: Drawing no.
Replaces:
Rev.
Subject:
ISIC A/S, Edwin Rahrs Vej 54, DK-8220 Brabrand. Tlf.: +45 70207077. Web: www.isic.dk
This docoment contains proprietary information and is not to be
used or reproduced without the written permission of ISIC A/S
Material: Surface:
Sheet: 1 of 1
ksc 22-05-2015
A3
Mechanical outline DuraPanel WS Glass 24''
AC 1:5 06669-000 1
384,1
593
52,4
576,8
8,1 8,1
0
7,8
19,5
62
66,5
23,2
367,98,1 8,1
R4
Recommended panel cut out
580
371
Max R4
R6,5 4x M6 x 18 Deep
546,6
97,4
VESA 280
VESA 150
120,1
57
67
Air vent outlet.
Do not cover!
263,5
85
78
LAN 2 LAN 1 USB 3/4 USB 1/2 HDMI Displayport
Audio
out
Audio
in
RS232
Power AC
User Reference Manual – DuraPANEL series
PN: 07354-000 Rev A Page 11

9Mechanical outline DuraPANEL 26”
1
1
2
2
3
3
4
4
5
5
6
6
A A
B B
C C
D D
417,6
73,5
8,78,7
621
435
52,3
0
7,8
40,2
82,8
87,3
603,6
8,7 8,7
Recommended panel cut out
423
609
R4
Max R4
R6,5
98
118,1
57
73
85
VASA 280
VASA 150
120,7
Displayport
Audio
in Audio
out HDMI
USB 3/4 USB 1/2
LAN 1
LAN 2
Power AC RS232
Air vent outlet.
Do not cover!
0
29
161
236
159
Approved by
Projection method: Drawing size:
Units: mm
Designed by
General tolerances: `0,2
Hole position: `0,1
Angle, straightness and flatness: DS/ISO 2768-H
Scale: Drawing no.
Replaces:
Rev.
Subject:
ISIC A/S, Edwin Rahrs Vej 54, DK-8220 Brabrand. Tlf.: +45 70207077. Web: www.isic.dk
This docoment contains proprietary information and is not to be
used or reproduced without the written permission of ISIC A/S
Material: Surface:
Sheet: 1 of 1
ksc 23-06-2015
A3
Mechanical outline DuraPanel Glass 26'' AC 1:5 07426-000 1
User Reference Manual – DuraPANEL series
PN: 07354-000 Rev A Page 12

10 Dura Communication protocol
See document 04924-000 for protocol details.
11 Compass safe distance
Test object / condition
Minimum Compass safe
distance [cm]
(5.4°/H deviation or a
horizontal magnetic flux of
0.094µT)
Minimum Compass safe
distance [cm]
(18°/H deviation or a
horizontal magnetic flux of
0.313µT)
DuraPANEL 24”
205
125
DuraPANEL 26”
225
140
12 Power Consumption
Test object / condition
Ptyp [W]
Pmax [W]
DuraPANEL 24”
60W
80W
DuraPANEL 26”
65W
85W
13 In rush current
Test object / condition
[A] @24VDC
[A] @230Vac
DuraPANEL 24”
~ 100
~ 100
DuraPANEL 26”
~ 100
~ 100
User Reference Manual – DuraPANEL series
PN: 07354-000 Rev A Page 13

14 Troubleshooting
Problem
Cause
Solutions
No picture on display
Backlight level set to
minimum
Increase backlight
Monitor turned off
Turn on the monitor
No input signal present
Apply signal
No power cord connected
Apply power
Buttons on front doesn’t work
Unit in ECDIS mode
Press Menu + Enter to unlock
the monitor
No power cord connected
Apply power
Keypad defect
Please do not try to open the
unit. Send it to ISIC A/S for
repair.
The unit smells burned /
smoke is coming from the unit
There might be something
burned inside
Please do not try to open the
unit. Send it to ISIC A/S for
repair.
15 Servicing the unit
In case that the unit still fails after following the troubleshooting send the unit to ISIC for
repair via our RMA service on our web.
User Reference Manual – DuraPANEL series
PN: 07354-000 Rev A Page 14

16 ISIC info / Support
In case you have inquiries or problems with your DuraPanel, you have a number of possibilities
to get support.
Company name:
ISIC A/S
Head office:
Edwin Rahrs Vej 54
DK-8220 Brabrand
Denmark
Shipping address:
Holmstrupgaardvej 5
DK-8220 Brabrand
Denmark
Telephone:
+45 70 20 70 77
Fax:
+45 70 20 79 76
Mail:
mail@isic-systems.com
www:
www.isic-systems.com
VAT number:
DK 16 70 45 39
Bank Name/Address:
Handelsbanken A/S
Havneholmen 29
DK-1561 København V
Denmark
Bank Code:
0892
SWIFT:
HANDDKKK
IBAN for DKK:
DK53 0892 0001 0159 69
IBAN for EUR:
DK48 0892 0003 0026 19
IBAN for USD:
DK26 0892 0003 0026 27
Contacts:
RFQ’s:
By fax to +45 70 20 79 76
By mail to sales@isic-systems.com
Orders:
By fax to +45 70 20 79 76
By mail to orders@isic-systems.com
Support:
Via homepage www.isic-systems.com under aftersales
By mail to service@isic-systems.com
During office-hours (Mo-Fr: CET 0800 - 1600) at +45 70 20 70 77
Service:
Before shipment for service Request Return Material Authorization
number at homepage www.isic-systems.com under AFTER SALES
TECH SUPPORT RMA
By mail to service@isic-systems.com
User Reference Manual – DuraPANEL series
PN: 07354-000 Rev A Page 15

17 Revision history
Rev A
August 2015
First release
User Reference Manual – DuraPANEL series
PN: 07354-000 Rev A Page 16

18 Appendix A: Pixel policy
ISO 9241-307:2008 guidelines for LCD pixel defects
Introduction
TFT displays consist of a set number of pixels. Each pixel consists of 3 sub-pixels also called dots (one red, one blue
and one green). Every sub-pixel is addressed by its own transistor. As a result, the manufacturing of glass substrate is
very complex.
Due to the nature of this manufacturing process, occasional defects can occur. Pixel defects or failures cannot be fixed
or repaired and may occur at any stage during the service life of the TFT display.
To regulate the acceptability of defects and protect the end user, ISIC A/S complies with the ISO 9241-307:2008
standard. This standard recommends how many defects are considered acceptable in a display, before it should be
replaced within the terms of the warranty.
Monitor classification ISO 9241-307:2008
Allowed defects per type per million pixels
Defect classes
Pixel defects Cluster defect
Type 1 Type 2 Type 3 total
(2xN3a + N3b)Type 1 Type 2 Type 3
Class: 0 0 0 0 0 0 0
Class: I 1 1 5 0 0 0
Class: II 2 2 10 0 0 1
Class: III 5 15 100 0 0 5
ISIC TFT monitors comply with ISO 9241-307:2008 Class II.
Special agreements about other classifications can be made between ISIC A/S and the customer.
Measurement method/monitoring conditions for pixel defects
In compliance with the ISO-9241-307:2008 standard, the following conditions are observed:
•Final check for pixel fault undertaken right after burn-in, i.e. with pre-heating of the display.
•Surrounding temperature 25ºC ± 5ºC
•Relative air humidity 40–70%
Pixel definition
Every pixel consists of three sub-pixels/dots (red, blue, green).
Every sub-pixel has its own transistor.
The three sub-pixels/dots must be considered as one unit.
User Reference Manual – DuraPANEL series
PN: 07354-000 Rev A Page 17

Pixel
Pixel defect type 1 Pixel constantly lit Pixel defect type 2 Pixel constantly dark
Pixel defect type 3a Pixel defect type 3b
Sub-pixel/dot (red, blue, green) constantly lit Sub-pixel/dot (red, blue, green) constantly dark
Cluster
A cluster consists of 5 x 5 pixels.
Cluster pixel defect type 1 Cluster pixel defect type 2
Pixels in a cluster area constantly lit Pixels in a cluster area constantly dark
Cluster pixel defect type 3a Cluster pixel defect type 3b
Sub-pixels/dots in a cluster area constantly lit Sub-pixels/dots in a cluster area constantly dark
User Reference Manual – DuraPANEL series
PN: 07354-000 Rev A Page 18

Pixel faults accepted by ISIC A/S
The maximum number of pixel faults that is considered acceptable at different screen resolutions is shown in the
table below.
This is the native resolution and not the resolution as adjusted by user.
Class II
Allowable number of pixel faults in monitor applications
Screen
type Native
resolution Number of
pixels Pixel defect
type 1 Pixel defect
type 2
Pixel defect
Type 3 total
(2xN3a + N3b)
Cluster
defect type
1 and 2
Cluster
defect
type 3
WVGA
800x480
384,000
0
0
3
0
0
XGA 1024x768 768,432 1 1 7
0
0
WXGA 1280x800 1,024,000 2 2 10
0
1
SXGA 1280x1024 1,310,720 2 2 13
0
1
UXGA 1600x1200 1,920,000 3 3 19
0
1
FHD 1920x1080 2,073,600 4 4 20
0
2
WUXGA 1920x1200 2,304,000 4 4 23
0
2
User Reference Manual – DuraPANEL series
PN: 07354-000 Rev A Page 19

19 Appendix C: Declaration of Conformity
User Reference Manual – DuraPANEL series
PN: 07354-000 Rev A Page 20
This manual suits for next models
1
Table of contents
Other ISIC Touch Panel manuals