ISIC DuraPanel Series User manual

User Manual
DuraPanel Series
DuraPanel 7”
DuraPanel 12”

Disclaimer
ISIC A/S makes no representation or warranties with respect to the contents or use of this
manual, and specifically disclaims any express or implied warranties of merchantability or
fitness for any particular purpose. Further, ISIC A/S reserves the right to revise this
publication and to make changes to its content at any time, without obligation to notify any
person or entity of such revisions or changes.
Image sticking: If the monitor is operated with static images (logo’s etc) it will inevitably
lead to images sticking on the display (like on old CRT’s). This is not a permanently situation
and can be removed by operating the monitor with a completely black screen.
FCC Warning
Computing devices and peripherals generate and radiate radio frequency energy, and if not
installed and used in accordance with the instructions advised by ISIC A/S, it may cause
interference to radio communication.
The DuraPanel series, manufactured by ISIC A/S, is designed to comply with the emerging
generic EEC standards, that cover applications in maritime environment.
Classification
The monitor is classified as “protected from the weather” according to IEC 60945 ed.4 (former
class b).
Approvals
Approval according to IACS E10 ed. 6 and IEC 60945 ed. 4, Maritime navigation and radio
communication equipment and systems – General requirements.
ISIC A/S is complying with the WEEE directive within the European Union, stating that
electronic and electric products must be collected separately.
Products are marked according to the directive.
Copyright 2015 ISIC A/S
ISIC PN: 07353-000 rev. B
ISIC A/S
Edwin Rahrsvej 54
DK-8220 Brabrand
Denmark
Phone: +45 70 20 70 77
Fax: +45 70 20 79 76
Web: http://www.isic-systems.com
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 2

Table of Contents
1FEATURES ............................................................................................................. 4
2GENERAL CONSIDERATIONS ON INSTALLATION AND OPERATION .......................4
3DURAPANEL CONNECTIONS .................................................................................. 5
4CONNECTOR PIN-OUT ........................................................................................... 6
5TECHNICAL SPECIFICATION DURAPANEL 7 .......................................................... 8
6TECHNICAL SPECIFICATION DURAPANEL 12 ........................................................ 9
7MECHANICAL OUTLINE DURAPANEL 7 – DROP IN............................................... 10
8MECHANICAL OUTLINE DURAPANEL 7 – FLUSH MOUNT ...................................... 11
9MECHANICAL OUTLINE DURAPANEL 7 – RETROFIT............................................. 12
10 MECHANICAL OUTLINE DURAPANEL 7 – SIMULATION ........................................ 13
11 MECHANICAL OUTLINE DURAPANEL 7 – OPTIONAL FAN..................................... 14
12 MECHANICAL OUTLINE DURAPANEL 12 INCH - FLUSH........................................ 15
13 MECHANICAL OUTLINE DURAPANEL 12 INCH - RETROFIT .................................. 16
14 MECHANICAL OUTLINE DURAPANEL 12 INCH – DROP IN....................................17
15 DURA COMMUNICATION PROTOCOL ................................................................... 18
16 BACKLIGHT, COLOR … ETC SETTINGS ................................................................. 22
17 COMPASS SAFE DISTANCE .................................................................................. 23
18 POWER CONSUMPTION....................................................................................... 23
19 IN RUSH CURRENT.............................................................................................. 23
20 TROUBLESHOOTING............................................................................................ 23
21 SERVICING THE UNIT ......................................................................................... 23
22 ISIC INFO / SUPPORT......................................................................................... 24
23 REVISION HISTORY ............................................................................................ 25
24 APPENDIX A: PIXEL POLICY................................................................................ 26
25 APPENDIX B: CERTIFICATE OF CONFORMITY...................................................... 29
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 3

1Features
Congratulations on your purchase of a DuraPanel. This short form manual is designed to get
you started working with your new DuraPanel.
The DuraPanel series of Panel Computers are all designed for the demanding operating
conditions at sea.
The DuraPanel series are tested for full compliance to marine-standards IACS E10 and IEC
60945.
The DuraPanel comes with excellent brightness and contrast levels that, together with wide
viewing angles, ensure a good readability thus making it very eye-friendly. For the best picture
quality, always use a double shielded DVI or VGA cable with ferrites on external monitor.
2General considerations on Installation and
Operation
The DuraPanel is designed to work at conditions according to IEC 60945. However, keeping the
temperature and vibration level at a minimum will extend the life time of the product. ISIC
recommend operating this product at normal room temperature (20-25 °C), with the lowest
level of vibration and humidity.
Installation of the DuraPanel
In order to obtain the best possible operating conditions, please note the following precautions.
-Room for cooling.
When designing the cabinet/console for the DuraPanel, please ensure that air can
flow freely around the cabinet, in order to avoid any unnecessary rise in
temperature. If it is not possible to have an adequate natural airflow, use a fan to
force the airflow to be higher.
-Mounting positions
The DuraPanel is designed for both horizontal and vertical installation.
-Sunlight
Avoid direct sunlight to keep temperature low by that improve lifetime.
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 4

3DuraPanel connections
Below is a view of connections to the DuraPanel.
3.1 DuraPANEL7” connections
* Optional fan output.
3.2 DuraPANEL12” connections
* FAN
PWR
4 x USB
4 x LAN
Serial
DVI-I
2 x PWR
DC
RESET
CHASSIS
*FAN
PWR
2 x USB
4 x LAN
Serial
2 x PWR
DC
RESET
DVI-I
CHASSIS
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 5

Pin1
4Connector pin-out
Mating part: SUB-D 9 pole female, Norcomp 172-E09-20201 or equivalent.
4.1 DuraPANEL7” Serial
COM port used for external communication
COM2
COM port used for internal communication
COM1
Pin
RS-232
RS-422
RS-485
1
DCD
Tx-
D-
2
RxD
Tx+
D+
3
TxD
Rx+
4
DTR
Rx-
5
GND
6
DSR
7
RTS
8
CTS
9
RI
COM2 settings RS232/422/485 is set in BIOS
4.1 DuraPANEL12” Serial
COM port used for external communication
COM1
COM port used for internal communication
COM2
Pin
RS-232
RS-422
RS-485
1
DCD
Rx+
D+
2
RxD
Rx-
D-
3
TxD
Tx+
4
DTR
Tx-
5
GND
6
DSR
7
RTS
8
CTS
9
RI
COM1 needs to be specified when DuraPANEL12 is ordered.
RS485 flow control is set in BIOS
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 6

Pin1
Pin1
4.2 Power input
The nominal input power voltage is 24V (18-36VDC). There are two independent galvanic isolated power inputs.
Mating part number: Weidmüller BLZP5.08HC/02/180F
Pin
Power in
1
0VDC
2
24VDC
4.3 Fan output
Mating part: JST XHP-2 (housing), SXH-001T-P0.6 (terminal)
Pin
FAN out
1
12VDC
2
0VDC
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 7

5Technical specification DuraPanel 7
DuraPANEL - General
CPU:
Intel
®
Celeron
®
Processor J1900, 2.42 GHz (4 Cores / 4 Threads)
Chipset: Intel®processor Core, Graphics and Memory Controller in a single system-on-chip (SOC)
solution
Memory: 1 x SODIMM sockets with 1x 4GB DDR3L 1600MHz mounted
Up to 8GB DDR3L SODIMM
Hard Disk Drive: 80GB Intel®S3500 SSD SATA
Optional sizes 120GB / 160GB / 240GB / 300GB … 800GB SSD SATA III
Video:
External Video out:
Intel®HD Graphics controller on-CPU
DirectX* 11 and OpenGL 4.0 compliant
Dual Independent display capable
1 x DVI-I video output connector
Audio:
Built-in Buzzer (75-85 dB(A) / 1m)
Ethernet: 4 x 10/100/1000 Mbits/s Ethernet LAN on-board, (RJ45) with auto-negotiate
2 x Intel and 2 x Realtek
USB:
2 x USB 2.0 (max 0,5 Amp per USB, max 5 Watt total)
COM:
1 x RS232/422/485 (BIOS configurable)
OS:
Windows 7, Windows 8, Linux
DuraPANEL - Front
Display size:
7 inch LCD (TFT), IPS technology
Resolution:
800 x 480
Active area:
152 x 91 mm
View angle:
89° (T/B), 89° (L/R) (typical)
Luminance: 450 Cd/m2(typical)
Optional Ambient light sensor
Contrast ratio:
Touch:
800:1 (typical)
10 finger PCAP touch (internal USB interface)
Front glass:
Anti Reflection
Protection: IP56 (from front, when mounted)
IP22 (from rear)
DuraPANEL - Power
Standard: 18-34VDC Galvanic isolated
Optional Dual input DC power, Galvanic isolated
Power Consumption:
Ptyp = 10 Watt, Pmax = 15 Watt
DuraPANEL - Environmental
Operating Temperature:
-15 to +55 °C
Storage Temperature:
-25 to +70 °C
Relative Humidity:
8 to 95 % (non-condensing)
DuraPANEL - Approvals
CE Mark:
EN61000-6-2
Marine:
IACS E10 Rev. 5 & IEC 60945 Ed. 4
Shock:
±5G, 10ms in accordance with IEC 60068-2-27
Certificates:
MR certificate
DuraPANEL - Dimensions
Size:
218 (W) x 147mm (H) x 59mm (Depth behind bezel)
Weight: App. 2 kg.
Optional Bracket:
Desk/ceiling-and wall-bracket (VESA 75x75mm)
Optional Accessories: External fan for VESA mounting
2 page flyer rev. 11.02.2016. Technical specifications are subject to change without prior notice. For drawing
and full technical specifications please consult the users manual.
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 8

6Technical specification DuraPanel 12
DuraPANEL - General
CPU:
Intel
®
Celeron
®
Processor 2980U (2M Cache, 1.60 GHz) (2 Cores / 2 Threads)
Chipset: Intel®processor Core, Graphics and Memory Controller in a single system-on-chip (SOC)
solution
Memory: 2 x SODIMM sockets with 1x 4GB DDR3L 1600MHz mounted
Up to 16GB DDR3L SODIMM
Primary Disk Drive: 80GB Intel®S3500 SSD SATA
Optional sizes 120GB / 160GB / 240GB / 300GB … 800GB SSD SATA
Optional Secondary Disk Drive (Removable): 80GB Intel®S3500 SSD SATA (optional)
Optional sizes 120GB / 160GB / 240GB / 300GB … 800GB SSD SATA
Video:
External Video out:
Intel®HD Graphics controller on-CPU
DirectX* 11 and OpenGL 4.0 compliant
Dual Independent display capable
1 x DVI-I video output connector
Audio:
Built-in Buzzer (75-85 dB(A) / 1m)
Ethernet: 4 x 10/100/1000 Mbits/s Ethernet LAN on-board, (RJ45) with auto-negotiate
1 x Intel
®
I218 and 3 x Intel
®
I210AT
USB:
COM:
OS:
4 x USB 3.0 (max 0,5 Amp per USB, max 5 Watt total)
1 x RS232/422/485 (configurable, choose when place order)
Windows 7, Windows 8, Linux
DuraPANEL - Front
Display size:
12,1 inch 16:10 LCD (TFT), MVA technology
Resolution:
1280 x 800
Active area:
261 x 163 mm
View angle:
88° (T/B), 88° (L/R) (typical)
Luminance: 400 Cd/m2(typical)
Optional Ambient light sensor
Contrast ratio:
Touch:
1000:1 (typical)
10 finger PCAP touch (internal USB interface)
Front glass:
Anti Reflection
Protection: IP56 (from front, when mounted)
IP22 (from rear)
DuraPANEL - Power
Standard: 18-34VDC Galvanic isolated
Optional Dual input DC power, Galvanic isolated
Power Consumption:
Ptyp = 20 Watt, Pmax = 25 Watt
DuraPANEL - Environmental
Operating Temperature:
-15 to +55 °C
Storage Temperature:
-25 to +70 °C
Relative Humidity:
8 to 95 % (non-condensing)
DuraPANEL - Approvals
CE Mark:
EN61000-6-2
Marine:
IACS E10 Rev. 5 & IEC 60945 Ed. 4
Shock:
±5G, 10ms in accordance with IEC 60068-2-27
Certificates:
MR certificate
DuraPANEL - Dimensions
Size:
396 mm (W) x 256 mm (H) x 63.5 mm (Depth behind bezel) – Drop-in retrofit 13.3” version
Weight: App. 4 kg.
Optional Bracket:
Desk/ceiling-and wall-bracket (VESA 75x75mm)
2 page flyer rev. 24.06.2015. Technical specifications are subject to change without prior notice. For drawing
and full technical specifications please consult the users manual.
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 9

7Mechanical outline DuraPanel 7 – Drop in
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
A A
B B
C C
D D
E E
F F
G G
H H
218
147
4x R0,5
0
3,5
52,1
58,1
65,1
VESA 75
VESA 75
VESA 4x M4x0.7 x 6 deep
32
136
213
2,5 2,5
5,55,5
10
6
214
195
137
126
134,4
204
4x Ø6,3
62,6
Approved by
Projection method: Drawing size:
Units: mm
Designed by KSC 25-08-2015
Mechanical outline DuraPanel 7" Drop in
NJS 25-08-2015
General tolerances:
`
0,2
Hole position:
`
0,1
Angle, straightness and flatness: DS/ISO 2768-H
Scale: Drawing no.
Replaces:
07376-001 A
Rev.
Subject:
ISIC A/S, Edwin Rahrs Vej 54, DK-8220 Brabrand. Tlf.: +45 70207077.Web: www.isic.dk
This docoment contains proprietary information and i s not to be
used or reproduced without the written permission of ISIC A/S
ECO
Material: Surface:
Sheet: 1 of 1
A1
1:1
Recommended panel cut out
134,4
204
4x M3 x max 3 deep
4x M3 x 12
2
n
6
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 10

8Mechanical outline DuraPanel 7 – Flush mount
Approved by
Projection method: Drawing size:
Units: mm
Designed by KSC 25-08-2015
Mechanical outline DuraPanel 7" Flush
NJS 25-08-2015
General tolerances:
`
0,2
Hole position:
`
0,1
Angle, straightness and flatness: DS/ISO 2768-H
Scale: Drawing no.
Replaces:
07376-004 A
Rev.
Subject:
ISIC A/S, Edwin Rahrs Vej 54, DK-8220 Brabrand. Tlf.: +45 70207077.Web: www.isic.dk
This docoment contains proprietary information and is not to be
used or reproduced without the written permission of ISIC A/S
ECO
Material: Surface:
Sheet: 1 of 1 A1
1:1
VESA 4x M4x0.7 x 6 deep
57,6
0
5
56,6
63,6
4,5
228
157
97
6x
n
4,5 THRU
4x R0,5
233
162
147
218
4x R8 VESA 75
VESA 75
39,5
7,5
7,5
7,5 7,5
148
219
Recommended panel cut out
228
157
97
6x M4 or Ø4,5
4x R1
213
136
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
A A
B B
C C
D D
E E
F F
G G
H H
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 11

9Mechanical outline DuraPanel 7 – Retrofit
0
7,1
54,5
61,5
237
154
19
4x R1
VESA 75
VESA 75
42
136 15,515,5
213 18,5
18,5
4x M5
250
167
154
237
143
215
4x Ø5,5
Recommended panel cut out
Approved by
Projection method: Drawing size:
Units: mm
Designed by KSC 25-08-2015
Mechanical outline DuraPanel 7" Retrofit
NJS 25-08-2015
General tolerances:
`
0,2
Hole position:
`
0,1
Angle, straightness and flatness: DS/ISO 2768-H
Scale: Drawing no.
Replaces:
07376-002 A
Rev.
Subject:
ISIC A/S, Edwin Rahrs Vej 54, DK-8220 Brabrand. Tlf.: +45 70207077.Web: www.isic.dk
This docoment contains proprietary information and is not to be
used or reproduced without the written permission of ISIC A/S
ECO
Material: Surface:
Sheet: 1 of 1
A1
1:1
VESA 4x M4x0.7 x 6 deep
55,5
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
A A
B B
C C
D D
E E
F F
G G
H H
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 12

10 Mechanical outline DuraPanel 7 – Simulation
140
266
4x M4 or Ø4,5
Approved by
Projection method: Drawing size:
Units: mm
Designed by KSC 25-08-2015
Mechanical outline DuraPanel 7" Simulator
NJS 25-08-2015
General tolerances:
`
0,2
Hole position:
`
0,1
Angle, straightness and flatness: DS/ISO 2768-H
Scale: Drawing no.
Replaces:
07376-003 A
Rev.
Subject:
ISIC A/S, Edwin Rahrs Vej 54, DK-8220 Brabrand. Tlf.: +45 70207077.Web: www.isic.dk
This docoment contains proprietary information and is not to be
used or reproduced without the written permission of ISIC A/S
ECO
Material: Surface:
Sheet: 1 of 1
A1
1:1
VESA 4x M4x0.7 x 6 deep
60,5
286
176
213 36,5
36,5
0
2,15
59,5
66,5
286
176
100
266
4x
n
4,5 -8 DEEP
w
n
9 X 90°
136 20
20
VESA 75
VESA 75
46,5
R6
Recommended panel cut out
215
143
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
A A
BB
C C
DD
EE
FF
G G
H H
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 13

11 Mechanical outline DuraPanel 7 – Optional fan
Approved by
Projection method: Drawing size:
Units: mm
Designed by KSC 24-9-2015
Mechanical outline Optional fan for
DuraPanel 7"
NHL 24-9-2015
General tolerances:
`
0,2
Hole position:
`
0,1
Angle, straightness and flatn ess: DS/ISO 2768-H
Scale: Drawing no.
Replaces:
07386-000 A
Rev.
Subject:
ISIC A/S, Edwin Rahrs Vej 54, DK-8220 Brabrand. Tlf.: +45 70207077. Web: www.isic.dk
This docoment contains proprietar y information and is not to be
used or reproduced without the writtenpermission of ISIC A/S
ECO .
Material: Surface:
Sheet: 1 of 1
A2
1:1
76,2
72
17
60
85
60
85
12VDC Plup for fan.
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 14

12 Mechanical outline DuraPanel 12 inch - Flush
218
314
Recommended panel cut out
323
227
130
8x M4 or Ø4,5
4x R1
Approved by
Projection method: Drawing size:
Units: mm
Designed by KSC 28-08-2015
Mechanical outline DuraPanel 12,1" Flush
NJS 28-08-2015
Generalt olerances:
`
0,2
Holepo sition:
`
0,1
Angle, straightness and flatness: DS/ISO 2768-H
Scale: Drawing no.
Replaces:
07377-002 A
Rev.
Subject:
ISIC A/S, Edwin Rahrs Vej 54, DK-8220 Brabrand. Tlf.: +45 70207077. Web: www.isic.dk
Thisdo coment contains proprietary information and is not to be
used or reproduced without the written permission of ISIC A/S
Material: Surface:
Sheet: 1 of 1
A0
1:1
0
64,5
71,5
4,5
304,6
25
88,5
VESA 4x M4 x0.7 x 6 deep
VESA 75
VESA 75
150
96
12,5 12,1
36
313
217
237
333
130
150
8x Ø4,5
R2,5
R13
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
A A
B B
C C
D D
E E
F F
G G
H H
I I
J J
K K
L L
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 15

13 Mechanical outline DuraPanel 12 inch - Retrofit
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
A A
B B
C C
D D
E E
F F
G G
H H
I I
J J
K K
L L
215
364
212
308
4x Ø5,5
Recommended panel cut out
Approved by
Projection method: Drawing size:
Units: mm
Designed by KSC 25-08-2015
Mechanical outline DuraPanel 12,1" Retrofit
NJS 25-08-2015
Generalt olerances:
`
0,2
Holepo sition:
`
0,1
Angle,st raightness and flatness: DS/ISO 2768-H
Scale: Drawingno.
Replaces:
07377-001 A
Rev.
Subject:
ISIC A/S, Edwin Rahrs Vej 54, DK-8220 Brabrand. Tlf.: +45 70207077. Web: www.isic.dk
Thisdo coment contains proprietary information and is not to be
usedor re produced without the written permission of ISIC A/S
Material: Surface:
Sheet: 1 of 1
A0
1:1
4x M5
18,5
0
7
62
69 304,6
44,4 46,5
396
256
4x R0,5
207 24,5
24,5
25
98 VESA 75
VESA 75
364
215
63 VESA 4x M4 x0.7 x 6 deep
12,5 9,6
96
24,5
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 16

14 Mechanical outline DuraPanel 12 inch – Drop In
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
A A
B B
C C
D D
E E
F F
G G
H H
I I
J J
K K
L L
304
289
208
193
203
299
4x Ø7,3
Approved by
Projection method: Drawing size:
Units: mm
Designed by KSC 28-08-2015
Mechanical outline DuraPanel 12,1" Drop in
NJS 28-08-2015
Generalt olerances:
`
0,2
Holepo sition:
`
0,1
Angle,s traightness and flatness: DS/ISO 2768-H
Scale: Drawing no.
Replaces:
07377-004 A
Rev.
Subject:
ISIC A/S, Edwin Rahrs Vej 54, DK-8220 Brabrand. Tlf.: +45 70207077. Web: www.isic.dk
Thisdo coment contains proprietary information and is not to be
used or reproduced without the written permission of ISIC A/S
Material: Surface:
Sheet: 1 of 1
A0
1:1
Recommended panel cut out
303,3
207,3
VESA 75
VESA 75
29,9 78,5
313
217
4x R0,5
0
4
65
72
4,85 4,85
4,85
4,9
70
VESA 4x M4 x0.7 x 6 deep
10
8
8
10
96
12,5
24,5
12,6
4x M4 x 12
203
299
n
7
2
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 17

15 Dura Communication protocol
15.1 Message Format
The interface board supports a data rate of 19200 bits per second.
Data shall be transmitted with no parity, one start bit, and one stop bit.
The basic message format is shown below:
ATTN
ADDR
CMD
LEN
IHCHK
DATA
IDCHK
The minimum message length is 7 bytes.
15.1.1 Attention (ATTN)
This byte identifies the start of a message. The following three values are defined:
ATTN Description
0x07 Command
0x06 Acknowledge
0x15 Negative Acknowledge
A remote master initiates a command using the 0x07 attention code. The interface board will reply with an acknowledge
(ACK) code if the command was received successfully, or a negative acknowledge (NACK) if the command contained
errors.
Note that the interface board will acknowledge messages, even if it fails to execute the actions contained within.
NACKs are only issued when the message format is corrupted, e.g. invalid checksums.
15.1.2 Address (ADDR)
This byte is used to identify and address individual interface boards. In a multi-slave configuration, the master can
target each interface board individually, in which case the addressed interface board will reply with either an ACK or a
NACK.
The remote master can address all interface boards simultaneously using the broadcast address. In this case the interface
boards will not reply.
ADDR Description
0x00:0xFE Individual address space
0xFF Broadcast address
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 18

15.2 Command (CMD)
The following commands are defined for the interface board:
CMD Description
MAN Manufacturer ID
BZZ Buzzer Control Command
FAN Fan Control Command
ETC Elapsed Time Counter
TMP Temperature Sensor
LIS Light Sensor
15.2.1 Data Length (LEN)
This byte contains the length of the DATA field. The minimum value is 0 bytes. No messages have been defined with a
length of more than 35 bytes.
15.2.2 Inverse Header Checksum (IHCHK)
This is a simple 8 bit checksum. The checksum byte is initialized to 0. A bit-wise inversion of bytes 0 to 5 is performed.
The 8 bit sum (without carry) of inverted bytes 0 to 5 and byte 6 shall be 0xFF.
If a message fails the checksum, the interface board will reply with a NACK message with zero data. This requirement
does not apply to broadcasted messages.
15.2.3 Data Sent (DS)
The DS field is only transmitted as a mirror of the sent data.
15.2.4 Data Field (DATA)
The data field is only transmitted if LEN is greater than 0. The field carries additional data depending of the message
command.
15.2.5 Inverse Data Checksum (IDCHK)
The inverse data checksum is only transmitted if LEN is greater than zero. The checksum is initialized to 0. A bit-wise
inversion of DATA field(s) is performed. The 8 bit sum (without carry) of the inverted bytes and the IDCHK shall be
0xFF.
The interface board will reply with a NACK to all messages with invalid checksums. This requirement does not apply
to broadcasted messages.
15.2.6 No Operation (NOP)
This is empty data ‘0x00’ and only used as a filler between detection bytes for the reset command.
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 19

15.3 Message Command
15.3.1 Manufacturer ID (MAN)
This command shall be sent to the interface board to request Manufacturer ID Code. No data shall be sent with the
command
The interface board will reply to this command with an ACK attention code. The DATA field will be set to an ASCII
string with the value “ISIC”.
Example:
Ask for the Manufacturer ID:
ATTN
ADDR
CMD
LEN
IHCHK
0x07
0x00
0x4D
0x41
0x4E
0x00
0x1C
Reply from interface board (“ISIC”):
ATTN
ADDR
CMD
LEN
IHCHK
DATA
IDCHK
0x06
0x00
0x4D
0x41
0x4E
0x04
0x19
0x49
0x53
0x49
0x43
0xD7
15.3.2 Monitor Firmware Version (VER)
This command is sent to the monitor to request the Firmware Version of the embedded code. No data shall be sent with
the command.
The monitor will reply to this command with an ACK attention code. The DATA field will be set to an ASCII string
with the ISIC P/N and revision. Maximum length is 20 characters.
Example:
Ask for the Monitor Firmware Version:
ATTN
ADDR
CMD
LEN
IHCHK
0x07
0x00
0x56
0x45
0x52
0x00
0x0B
Reply from monitor (“07050-000-B”):
ATTN
ADDR
CMD
LEN
IHCHK
DATA
0x06
0x00
0x56
0x45
0x52
0x0B
0x01
0x30
0x37
0x30
0x35
0x30
0x2D
DATA (cont.)
IDCHK
0x30
0x30
0x30
0x2D
0x42
0xD7
15.3.3 Buzzer Control Command (BZZ)
This command will change the state of the buzzer on interface boards with a buzzer integrated.
The value placed in the DATA field selects the state of the buzzer as listed below:
DATA State
0x00 Turn the buzzer off (DEFAULT)
0xFF Turn the buzzer on
If the checksum is valid and the command completes successfully, the interface board will reply with an ACK message
with the current buzzer state in the DATA field.
If the checksum was invalid, the interface board will reply with an ACK message.
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 20