Isotech IDM5 User manual

V
V
Auto Power Off(Battery Saver)
Press
Display Hold
HOLD HOLD
Press
OFF
OFF
AUTO
SENSE
DC
AUTO
SENSE HOLD
DC
V
V
SENSE
AUTO
DC
V
HOLD
HOLD
20min
V
V
Auto Power Off(Battery Saver)
Press
Display Hold
HOLD HOLD
Press
OFF
OFF
AUTO
SENSE
DC
AUTO
SENSE HOLD
DC
V
V
SENSE
AUTO
DC
V
HOLD
HOLD
20min
RANGE RANGE
Auto Range/Manual Range
Press < 1sec
to change
the range
Press > 1sec
Press
DC
V
DC
V
AUTO
SENSE
RANGE
OTROS
Auto
Sense
Note: Last
SELECT
Press
SELECT
Selecting Function
Hz
Hz
%
Hz
1
1
2
3
L
2 3 L
L
RANGE RANGE
Auto Range/Manual Range
Press < 1sec
to change
the range
Press > 1sec
Press
DC
V
DC
V
AUTO
SENSE
RANGE
OTROS
Auto
Sense
Note: Last
SELECT
Press
SELECT
Selecting Function
Hz
Hz
%
Hz
1
1
2
3
L
2 3 L
L
Resistor/Capacitor/
HOLD RANGESELECT
Black
Red
Black Red Black
Red
Black
Red
Continuity/Diode
SENSE
AUTO
V
AUTO
SENSE
V
AUTO
SENSE k
SENSE
AUTO
F
AUTO
SENSE
F
SENSE
AUTO OLF OLM
RANGESELECTHOLD
AC V /DC V /Hz /Duty
Hz
%
V
AUTO
SENSE AC
V
AUTO
SENSE
DC
V
Hz
VHz
Safety Information
Read and understand this Instruction Manual completely
before using this instrument. Failure to observe the
warnings and cautions in this Instruction Manual may
result in injury or death, or damage to the instrument and
other equipment or property.
The following symbols may appear on the
instrument and in this Instruction Manual:
Warning
If this instrument is used in a manner not specied
in these instructions, the protection provided by the
instrument may be impaired.
Examine the instrument, probes and leads before use.
Do not use the instrument if it is wet or damaged, or if
you suspect it is not operating correctly.
• Always use the correct switch position and range for
measurements.
• Do not apply more than the rated voltage as marked
on the instrument between terminals, or between any
terminal and earth ground.
• To avoid incorrect readings that can lead to electric
shock, replace the battery as soon as low battery
indicator appears in the display.
• Use caution when measuring voltages above 30 Vac
rms or 60 Vdc. These voltages pose a shock hazard.
• Disconnect the circuit power and discharge all high-
voltage capacitors before making resistance, continuity,
diode, or capacitance measurements.
• Do not use the instrument in a Hazardous Area or
around explosive gasses or vapours.
• When using the instrument, test leads or probes, keep
your ngers behind the nger guards.
• Wear suitable Personal Protective Equipment when
working around or near Hazardous Live conductors
which could be accessible.
Caution
• When connecting the test leads to a circuit or device,
connect the black lead before the red lead and
disconnect the red lead before the black lead.
• If possible, do not work alone, so assistance can be
given if required.
• If this instrument is used in the vicinity of equipment
which generates electromagnetic interference, the
display may become unstable or the measurements
may be subject to large errors.
• Do not expose the instrument to extremes of
temperature or high humidity.
The internal sounder will operate continuously and
the LCD display will ash in two situations in the
Data Hold mode:
1. The instrument measures a signal different to that
shown on the LCD.
2. The measured signal is the same units as the LCD
reading, but different by more than 50 counts to the
LCD reading.
• For greater measurement accuracy of low-value
capacitance, subtract the residual capacitance of the
instrument and leads from the measured value.
• Under diode mode, the LCD will display “bad” when
measuring a diode which conducts in forward and
reverse bias.
• The instrument will default to capacitance mode when
no component is sensed by the Auto-sense mode.
• When using Auto-sense mode, do not attempt to
measure a faulty component, an unknown component,
or a component with mixed electrical characteristics
such as a resistor and a capacitor in parallel. The
instrument may display incorrectly.
Risk of electric shock
Refer to Instruction Manual
Equipment protected throughout by double or
reinforced insulation
Battery
Earth
Conforms to applicable EU directives
Dispose of this equipment in accordance with
local regulations.
Auto Power-off
Auto Range / Manual Range Resistor / Capacitor / Continuity / Diode AC V / DC / Hz / Duty
Non-contact Volt Sense
Selecting Function
Display Hold
Disconnect
I
SELECT RANGEHOLD
AC A /DC A
Volt Sence
Black
Red
A
SENSE
AUTO
DC
A
Red
V
RANGEHOLD SELECT
V
1
4
2
5
3
6
Instruction Manual
IDM5 Digital Multimeter
EN
300V CAT III
600V CAT II
Hz
F
n
mA
V
m
AC
DC
Mk
OLFM
HOLD
SENSE
AUTO
OFF
Hz
%
RANGE
V
HOLD
V
SELECT
IDM5
Asia
Iso-Tech
460 Alexandra Road, #15-01A
PSA Building
Singapore 119963
USA
7410 Pebble Drive
Fort Worth
Texas 76118-6961
Europe
Iso-Tech
PO Box 99
Corby
Northamptonshire
NN17 9RS
United Kingdom
Canada
1701 Woodward Drive
Ste 108 Ottawa
Ontario K2C 0R4, Canada
Japan
West Tower (12th Floor)
Yokohama Business Park
134 Godocho, Hodogaya
Yokohama, Kanagawa 240-0005 Japan
South America
Av. Pdte. Eduardo Frei M. 6001-71
Centro Empresas El Cortijo
Conchali, Santiago, Chile

AC A / DC A
Carry Case Assembling
87
1211
9
13
10
14
Warning – For non-contact voltage sensing, do not
touch Hazardous Live conductors with the red or black
test-probe.
• For non-contact voltage sense, place the top of
the instrument body or the red test-probe near
the conductor.
• The buzzer will sound and the number of dashes
shown on the LCD will indicate the relative electric eld
strength. If there is no indication, a voltage may still be
present.
For calibration and repair contact RS Components - the
address is given at the end of these instructions.
Cleaning
Periodically wipe the case with a dry cloth and detergent.
Do not use abrasives or solvents.
Battery Replacement
WARNING
Disconnect the test leads from the circuit before
removing the battery cover.
Refer to the following gure to replace the batteries:
Specications
1-1 General Specications
LCD display digits:
4000-count large-scale Liquid Crystal Display.
Measuring rate: 3 times / sec.
Polarity Indication: Automatic, positive implied,
Overrange display: “OL” or “-OL”
Unit symbol indication.
Automatic power off time:
Approximately 20 minutes after power on.
Low battery indicator: is displayed.
Power requirement: 2 x 1.5V LR44 type batteries.
Battery life: 50 hours (GPA76P)
1-2 Environmental Conditions
Indoor Use Only.
Calibration: One year calibration cycle.
Operating temperature:
0°C to 30°C ( 80% RH)
30°C to 40°C ( 75% RH)
40°C to 50°C ( 45%RH)
Operating altitude: 2000m (6562 ft)
Pollution degree: 2
EMC: EN 61326-1
Dimensions (W x H x D): 56 x 12 x 112mm
Weight: 115g
Accessories: Batteries (installed), carry case and
Instruction manual.
1-3 Electrical Specications
Accuracy is ±(% reading + number of digits) at
23°C ± 5°C < 80%RH.
Storage temperature:
-20 to +60°C, 0 to 80% RH (batteries not tted).
Temperature coefcient: Add 0.2 x (Specied
accuracy) / °C, < 18°C, > 28°C.
Shock and vibration: Sinusoidal vibration per
MIL-T-28800E (5 to 55 Hz, 3g maximum).
Drop Protection: 4 feet drop onto hardwood or
concrete oor.
Overvoltage (Measurement) category:
IEC 61010-1 300V CAT , 600V CAT .
Measurement Category l is for measurements
performed on circuits not directly connected to mains.
Examples include: Measurements on battery powered
equipment and specially protected (internal) mains-
derived circuits.
Measurement Category ll is for measurements on
circuits directly connected to the low voltage installation.
Examples include: Household appliances, portable tools
and similar equipment.
Measurement Category lll is for measurements
performed in the building installation. Examples
include measurements on distribution boards, junction
boxes, socket-outlets and wiring and cables in the
xed installation.
Maintenance
Do not attempt to repair this Instrument. It contains no
user-serviceable parts. Repair or servicing should only be
performed by qualied personnel. This instrument should
be calibrated yearly or more frequently if used in harsh
conditions or if it is suspected of being inaccurate.
Disconnect
I
SELECT RANGEHOLD
AC A /DC A
Volt Sence
Black
Red
A
SENSE
AUTO
DC
A
Red
V
RANGE
HOLD SELECT
V
RANGEHOLD SELECT
Battery Replacement
1
Carry Case Assembling
1
2
2
RANGEHOLD SELECT
Battery Replacement
1
Carry Case Assembling
1
2
2
Function Range Resolution Accuracy
ACV
400.0mV 0.1mV ± (1.5%+ 5 D)
4.000V 0.001V
± (0.9%+ 5 D)
40.00V 0.01V
400.0V 0.1V
600V 1V
Function Range Resolution Accuracy
Cap
40.00nF 0.01nF ±(5%+ 0.4nF )
400.0nF 0.1nF
±(2.9%+ 5 D)
4.000µF 0.001µF
40.00µF 0.01µF
400.0µF 0.1µF
Function Range Resolution Accuracy
ACA 400.0µA 0.1µA ± (1.5%+ 5 D)
4.000mA 0.001mA
Function Range Resolution Accuracy
DCA 400.0µA 0.1µA ± (0.9%+ 5 D)
4.000mA 0.001mA
Function Range Resolution Accuracy
%
0.1 - 99.9%
0.1%
± (0.5%+10 D) *
Function Range Resolution Accuracy
Hz
40.00Hz 0.01Hz
±(0.3%+ 5 D)
400.0Hz 0.1Hz
4.000KHz 0.001KHz
40.00KHz 0.01KH
Function Range Resolution Accuracy
DCV
400.0mV 0.1mV ± (0.7%+ 5 D)
4.000V 0.001V
± (0.6%+ 2 D)40.00V 0.01V
400.0V 0.1V
600V 1V ± (0.7%+ 5 D)
Function Range Resolution Accuracy
Ohm
400.0Ω 0.1Ω ± (0.9%+ 5 D)
4.000kΩ 0.001kΩ
± (0.9%+ 2 D)40.00kΩ 0.01kΩ
400.0kΩ 0.1kΩ
4.000MΩ 0.001MΩ ± (1.5%+ 5 D)
40.00MΩ* 0.01MΩ
Frequency Response: 50 to 500Hz
AC Conversion Type: AC Coupled Average sensing,
RMS Indication.
Input Impedance: 10MΩ || <100pF.
Overload protection: 600V rms.
Open Circuit Voltage: 0.4V
* Rolling of digits of less than ± 2%
Overload protection: 600V rms.
CONTINUITY CHECK
Continuity Threshold: Approx. <50Ω
Continuity Indicator: 2.7KHz Tone Buzzer.
Input Protection: 600V rms.
Measuring Time: <30sec. (400.0µF range),
<10sec. (40.0µF range), <3sec. (other range)
Overload protection: 600V rms.
*30% ≤ Duty ≤ 70%,
Square Wave (5 Hz to 1KHz)
Sensitivity: 1.5Vp-p
Overload protection: 600V rms.
Frequency Response: 50 to 500Hz
AC Conversion Type: AC Coupled Average Sensing,
RMS Indicating.
Input Impedance: Approx. 3KΩ
Overload protection: 600V rms.
Input Impedance: Approx. 3KΩ
Overload protection: 600V rms.
DIODE TEST
Test Current: Typical. 350µA
Open Circuit Voltage: Max. 1.8V DC
Input Protection: 600V rms.
Sensitivity: > 10Vp-p (40KHz range) > 1.5Vp-p
(other ranges)
The signal must have positive and negative portions
of a cycle.
Max. Sensitivity: 600V rms.
Overload protection: 600V rms.
Input Impedance: 10MΩ || <100pF.
Overload protection: 600V rms.
Table of contents
Other Isotech Multimeter manuals

Isotech
Isotech ICM33R II User manual

Isotech
Isotech IDM 91E User manual

Isotech
Isotech IDM 205 RMS User manual

Isotech
Isotech IDM19 User manual

Isotech
Isotech ICM A7-4 User manual

Isotech
Isotech IPM 138 User manual

Isotech
Isotech IDM101 User manual

Isotech
Isotech IDM 98-III User manual

Isotech
Isotech IDM61 User manual

Isotech
Isotech ICM36R User manual

Isotech
Isotech IDM 91E User manual

Isotech
Isotech IDM63N User manual

Isotech
Isotech IDM99II User manual

Isotech
Isotech IDM17 User manual

Isotech
Isotech IDM19 User manual

Isotech
Isotech IDM 103N User manual

Isotech
Isotech IDM201N User manual

Isotech
Isotech ICM 136R User manual

Isotech
Isotech IDM 97 User manual

Isotech
Isotech IDM93N User manual