3
1. INTRODUCTION
Thank you for choosing the JABLOTRON 100+security system. This system
is a unique flexible indoor solution for commercial and home security that offers
the use of both wired and wireless devices. The JABLOTRON 100+is very easy
to control. Simplicity of control consists of two steps, authorization with a code
or a RFID tag followed by pressing an individual keypad segments with assigned
function on a keypad. It is possible to use a reversed method when the “Default”
system profile is enabled. Press a segment button first and then authorize.
The control segments use a simple traffic light logic which everyone can
understand. The number of segments can be promptly adapted to requirements
of premises. The JABLOTRON 100+series offers a wide range of detectors
with timeless design. It can be operated from anywhere owing to complete
remote control access. The MyJABLOTRON web interface, the MyJABLOTRON
application for smart phones and the J-Link software allow you to control,
program and monitor the system remotely.
The JABLOTRON 100+system is designed for up to 600 users and it can
be divided into 15 individual sections. Up to 230 devices can be connected and
the system offers up to 128 multi-purpose programmable outputs (e.g. home
automation).
The security system can be controlled in a number of different ways. To unset the alarm, authorization
in the form of user identification is always required. The system detects the identity of the users and allows
them to operate those parts of the system which they have been assigned to control. You can choose from
different ways of setting with or without authorization. When Standard authorization type is used, you don’t have
to authorize yourself because it is possible to set the system just by pressing the right segment button
on a keypad. The user name, date, and time are recorded and stored in the system memory every time
the system is accessed. This information is available indefinitely. Any user can also cancel a triggered alarm
(stop sirens from sounding) just by authorization in any part of the system (depending on their access rights).
However, that does not automatically unset the system (unless the system’s default setting is changed).
Note: Depending on the configuration of the installation and system settings, some of the options
described below may not be available. Consult the configuration of the installation with your service technician.
Users and their access rights
CODE
AUTHORIZATION
TYPE DESCRIPTION
ARC code This code has the highest level of authorization to configure the system’s behaviour and is exclusively
allowed to perform the system unblock after a triggered alarm. It can enter Service mode, access all tabs
with options including ARC communication to which it can deny access to a Service technician (Service
code). As long as the “Administrator-restricted Service/ARC right” parameter remains unchecked, the ARC
code can control all sections and PG outputs used in the system. This code enables to add more Administra-
tors and other users with a lower level of authorization, assign them with codes, RFID tags and cards.
It also has a permission to erase alarm and tamper alarm memory.
The number of ARC codes is limited only by remaining capacity of the control panel and there
is no code set by the factory defaults.
Service code
(Service)
This code can enter Service mode and configure the system’s behaviour. It has access to all tabs with
options including ARC communication unless the access is limited by the ARC technician. As long
as the “Administrator-restricted Service/ARC right” parameter remains unchecked, the Service code can
control all sections and PG outputs used in the system. It can create users with ARC permission, other
Service technicians, Administrators and other users with a lower level of authorization and assign them with
access codes, RFID tags and cards. It also has a permission to erase alarm and tamper alarm memory.
The number of Service codes is limited only by remaining capacity of the control panel.
By the factory defaults, the code is 1010. The Service user is always on position 0 in the control
panel and it cannot be erased.
2. OPERATING THE JABLOTRON 100+ SYSTEM