manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. jablotron
  6. •
  7. Security System
  8. •
  9. jablotron JA-11A User manual

jablotron JA-11A User manual

Other jablotron Security System manuals

jablotron Azor User manual

jablotron

jablotron Azor User manual

jablotron JA-152A User manual

jablotron

jablotron JA-152A User manual

jablotron JA-60 "Comfort" User manual

jablotron

jablotron JA-60 "Comfort" User manual

jablotron JA-63 PROFI" User manual

jablotron

jablotron JA-63 PROFI" User manual

jablotron OS-360A User manual

jablotron

jablotron OS-360A User manual

jablotron JA-60 "Comfort" User manual

jablotron

jablotron JA-60 "Comfort" User manual

jablotron JA-63 PROFI" User manual

jablotron

jablotron JA-63 PROFI" User manual

jablotron JA60K User manual

jablotron

jablotron JA60K User manual

jablotron 100+ User manual

jablotron

jablotron 100+ User manual

jablotron JA-162A User manual

jablotron

jablotron JA-162A User manual

jablotron JA-10 Series User manual

jablotron

jablotron JA-10 Series User manual

jablotron OS-360A User manual

jablotron

jablotron OS-360A User manual

jablotron OS-360 User manual

jablotron

jablotron OS-360 User manual

jablotron JA-162A-UK User manual

jablotron

jablotron JA-162A-UK User manual

jablotron JA-80-Oasis User manual

jablotron

jablotron JA-80-Oasis User manual

jablotron JA-163A Series User manual

jablotron

jablotron JA-163A Series User manual

jablotron JA-60N User manual

jablotron

jablotron JA-60N User manual

jablotron Oasis JA-80 User manual

jablotron

jablotron Oasis JA-80 User manual

jablotron JA-114E User manual

jablotron

jablotron JA-114E User manual

jablotron JA-63 PROFI" User manual

jablotron

jablotron JA-63 PROFI" User manual

jablotron MAESTRO JA-65 User manual

jablotron

jablotron MAESTRO JA-65 User manual

jablotron JK-84 Oasis User manual

jablotron

jablotron JK-84 Oasis User manual

jablotron Profi User manual

jablotron

jablotron Profi User manual

jablotron 100 User manual

jablotron

jablotron 100 User manual

Popular Security System manuals by other brands

Polon-Alfa 4000 Installation and maintenance manual

Polon-Alfa

Polon-Alfa 4000 Installation and maintenance manual

Nexcom NViS 14162 Series user manual

Nexcom

Nexcom NViS 14162 Series user manual

Eminent EM8670 Quick install

Eminent

Eminent EM8670 Quick install

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

urmet domus

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

SmartPool YardGuard YG03 manual

SmartPool

SmartPool YardGuard YG03 manual

DSC PC5964 Mounting instructions

DSC

DSC PC5964 Mounting instructions

Secure USAB-1 operating instructions

Secure

Secure USAB-1 operating instructions

B&B 480 SERIES Operation & maintenance manual

B&B

B&B 480 SERIES Operation & maintenance manual

ADEMCO VISTA-20P Series Installation and setup guide

ADEMCO

ADEMCO VISTA-20P Series Installation and setup guide

Inner Range Concept 2000 user manual

Inner Range

Inner Range Concept 2000 user manual

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Johnson Controls

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Aeotec Siren Gen5 quick start guide

Aeotec

Aeotec Siren Gen5 quick start guide

Swann SW-P-MC2 Specifications

Swann

Swann SW-P-MC2 Specifications

Ecolink Siren+Chime user manual

Ecolink

Ecolink Siren+Chime user manual

EDM Solution 6+6 Wireless-AE installation manual

EDM

EDM Solution 6+6 Wireless-AE installation manual

Siren LED GSM operating manual

Siren

Siren LED GSM operating manual

Detection Systems 7090i Installation and programming manual

Detection Systems

Detection Systems 7090i Installation and programming manual

FRIEDLAND MA10 Installation and operating instructions

FRIEDLAND

FRIEDLAND MA10 Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

JABLOTRON ALARMS a.s.
Pod Skalkou 4567/33 46601 Jablonec n. Nisou
Czech Republic www.jablotron.com
||
|
JA-11A RB BUS external siren
JA-11A RB BUS external siren 1 / 1 MLQ54101
The JA-11A RB is a component of the JA-10 system. It is used for
system alarm indication outside a building and as a pre-sensing tamper
detector. It can also be used for supplementary acoustic signalling.
The siren is equipped with a backup battery which powers the siren
during tamper alarm reporting when the connection to the digital bus
is severed. The JA-11A RB is completed by assembling two parts,
the JA-11A-BASE-RB base with the PCB and the JA-1XA-C-WH cover.
The siren occupies one position in the system.
Installation
The siren should
be installed on a vertical
wall, with the flasher
facing down-wards.
Avoid installing the siren
near the gutters and on
other places where there
is a danger of ice
accumulation.
Figure: 1 – mounting hole;
2 – two piezzo sirens;
3 – NiCd battery with
reusable battery strap;
4 – hole for cable;
5 – bus-cable; 6 – PCB;
7 – spirit level;
8 – mounting hole with
tamper detection;
9 – front cover screw;
10 – string with clip
connecting the front
cover for easy
installation
1. Open the external siren cover by releasing the screw (9).
2. Push the bus cable (5) through the hole (4) in the bottom part and
secure it using the plastic tabs.
3. Attach the siren to a suitable place using 2 screws through the holes
(1) and (8). The spirit level can be used for easy installation (7).
When connecting the siren to the system
bus, always switch the power off.
Figure: 11 – bus terminals; 12 – LEARN (enrollment) button; 13 – tamper
sensors; 14 – production code; 15– high-intensity red LED flashers;
16 – yellow fault indicator; 17 – backup battery connection;
18 – piezo siren connection (attention: high voltage)
4. Connect the bus cable to the terminals (11).
5. Connect the backup battery to the connector (17).
6. Proceed according to the control panel installation manual.
Basic procedure:
a. When the siren is switched on, the yellow LED (16)
indicates that the siren has not been enrolled into the
system.
b. Go to the N-Link software, select the required position
in the Devices tab and launch the enrollment mode by
clicking on the Enroll option.
c. Press the enrollment button (12) – the siren is thus
enrolled and the yellow LED indicator goes off.
7. Put back the siren cover and attach it using the screw (9).
8. The siren can be tested by N-Link software by clicking the Test
button in the internal settings option. After clicking the button the
siren sounds for three minutes and after that flashes for one
minute.
Internal settings of the siren
The siren properties can be set in the Devices window of the
N-Link program. When at the siren position, use the Internal
settings option to open a dialog window where you can set:
(default settings are marked *):
Setting tab:
Acoustic indication of alarms from sections: to set for which
sections the siren should indicate an alarm, as well as setting chirps.
The default setting is indication for all sections.
Reaction: defines whether the siren should indicate EW* (external
warning) or IW (internal warning); Alarm indication can also be disabled
completely (other functions remain enabled).
Siren sound: intermittent*, continuous.
Maximum siren time: No, 1, 2, 3*, 4, 5 minutes. Option ‘No’ – the
siren doesn’t indicate alarm acoustically (optical indication remains)
During section control: YES / NO* if enabled, the siren chirps once
upon setting and twice upon unsetting and three times upon unsetting
after an alarm. The signalling only works for the preset sections.
Optical indication
Flashes every 60 seconds: YES / NO* optional indication of siren
functioning.
After alarm expiration: During alarms, until memory erased,
30 minutes after an alarm - the optical indication can be extended
until the alarm indication is terminated (by new system setting/
unsetting) or the extended time can be set to 30 minutes after the alarm
expiration.
Signalling PG tab:
The siren can indicate PG output activity with its chirps.
The siren can indicate the activity of selected PG outputs with its
beeps.
Slow beeping - 1 per second (for the whole period when the PG
is active)
Quick beeping - 2 per second (for the whole period when the PG
is active)
1xOn/2xOff - 1 chirp when the PG is activated, 2 chirps when the PG
is deactivated
20 seconds of beeping – a long 20 s beep when the PG is activated
Sound priorities
The siren sound has the highest priority, the control chirps have a
lower priority and the PG output activity indication has the lowest priority
(PG1 has a higher priority than PG2 etc). The chirp with a higher priority
always terminates the chirp with a lower priority.
Loss of communication with the control
panel
If the power supply wire is severed, the siren keeps sounding and
flashing for 3 minutes (this function does not work in service mode). If the
system power supply is disconnected due to a discharged control panel
battery (long lasting power failure) then the siren does not sound and
flash.
Backup battery replacement
The system reports a low battery automatically. The control panel
must be in service mode before you start changing the battery
otherwise a tamper alarm will be triggered. Use a BAT-4V8 battery
only.
JA-11A RB BUS external siren
JA-11A RB BUS external siren 2 / 1 MLQ54101
Technical specifications
Power from control panel digital bus 12 V (9…15 V)
Current consumption in standby mode 5 mA
Current consumption for cable choice 50 mA
Backup battery NiCd pack 4.8 V/1800 mAh
lifetime approx. 3 years
-minimum loaded voltage 4.0 V
(replace the battery when voltage drops down this value)
-maximum unloaded voltage 6.0 V
reusable battery strap
Piezoelectric siren 110 dB/m (with fully charged battery)
Dimensions 200 x 300 x 70 mm
Weight without battery 434 g
Classification Security grade 2/environmental class IV
according to EN 50131-1, EN 50131-4,
environment general outdoor
operational temperature range -20 °C to +60 °C
operational humidity 90% RH, non-condensing
power supply type W/12 hours backup
certification body Trezor Test s.r.o. (no. 3025)
Security grade IP44
Also complies with EN 50130-4, EN 55032, EN 62368-1, EN 50581
JABLOTRON ALARMS a.s. hereby declares that the JA-11A
RB is in
a compliance with the relevant Union harmonisation
legislation: Directives No:
2014/35/EU, 2014/30/EU,
2011/65/EU. The original of the conformity assessment can be
found at www.jablotron.com - Section Downloads.
Note: Although this product does not contain any harmful materials
we suggest you return the product to the dealer or directly to the
producer after use. For more detailed information visit
www.jablotron.com.