INSTALLATION INSTRUCTIONS (cont.)
ELECTRICAL
Electrical Power Supply: These instructions are written
assuming 60Hz, 120V power supply. Special notations are
alsoincludedforexportversionsoftheequipmentandpower
supply.
WARNING: Verification of electrical requirements MUST
bemadebeforeinstallation.Refertotheequipmentlabels
for voltage and frequency requirements.
NOTE: Verify that the electrical service matches either the
120v or 240v system requirements for this bath.
NOTE: Thebath is designedfor indoor use only. The electri-
calequipmentmustnotbeexposedtodirectorindirectwater
or moisture contact. The electrical equipment must also be
protectedfromdustand otherairbornedebrisbefore,during,
and after installation.
1. Electrical Service: A licensed electrician must provide
the “dedicated” electrical service protected by a GFCI.
The location of the GFCI must be at least five (5) feet
(152cm)awayfrom theinside surfaceofthe bath,acces-
sible for regular testing. Use copper conductors only.
DANGER—RISKOFELECTRICSHOCK:Connectonly
toacircuitprotectedbyaGroundFaultCircuitInterrupter
(GFCI).Intheunlikelyoccurrenceofacurrentimbalance
inthepowerconductors,theGFCIwillinterruptthepower
to the bath.
WARNING: The electrical service to the GFCI must not
beinterruptedbyanycontroldevice.Likewise,theelectri-
cal service from the GFCI to the bath control should be
directandnotinterruptedbyaswitch.Neveruseaswitch
inconjunctionwithacontroldevice.ThiswillVOID THE
MANUFACTURER’S WARRANTY.
2. GROUNDING IS REQUIRED. The unit should be
installed by a qualified service representative and
properly grounded.
3. INSTALLSERVICECONNECTIONATLEAST6"(15cm)
ABOVE SUB FLOOR.
ALLLOCALANDSTATEELECTRICALANDPLUMB-
ING CODES MUST BE OBSERVED. Where there are
no local codes, the National Electric Code (NEC) and
Uniform Plumbing Code (UPC) shallbeobserved.It is
theresponsibilityoftheinstaller/ownertodeterminespe-
cific code compliance prior to installation of the product.
NOTE:IntheCommonwealthofMassachusetts,installa-
tionis tobe done by aMassachusetts licensedplumber.
DANGER: Do not alter the factory installed wiring.
All building materials and wiring should be routed
away from the equipment or other heat-producing
components of the unit.
4. Whirlpool Equipment
ThisWhirlpoolbathisprovidedwithanAirOn/Offswitch.
The pump is pre-wired to a control box which has a 36"
cord. Connect the pump to a GFCI (Ground Fault Circuit
Interrupter) with the proper service:
Standard Equipment (120V,60Hz).
120V,20A,60Hzelectricalservicewithaserviceground
receptacle dedicated for use by this bath.
Export Whirlpool Equipment (240V,60Hz).
240V,15A,60Hzelectricalservice withaserviceground
receptacle dedicated for use by this bath.
Export Whirlpool Equipment (120V,50Hz).
120V,20A,50Hzelectricalservicewithaserviceground
receptacle dedicated for use by this bath.
Export Whirlpool Equipment (240V,50Hz).
240V, 15A,50Hzelectricalservicewithaservice ground
receptacle dedicated for use by this bath.
5. MicroSilk®Equipment
This MicroSilk®bath is provided with an Air On/Off switch.
The pump is pre-wired to a junction control box which has
a 36" cord. Connect the pump to a GFCI with the proper
service:
Standard Equipment (120v,60Hz).
120V,20A,60Hzelectricalservicewithaserviceground
receptacle dedicated for use by this bath.
Export Whirlpool Equipment (240V,60Hz).
240V,15A,60Hzelectricalservice withaserviceground
receptacle dedicated for use by this bath.
Export Whirlpool Equipment (120V,50Hz).
120V, 20A,50Hzelectricalservicewithaserviceground
receptacle dedicated for use by this bath.
Export Whirlpool Equipment (240V,50Hz).
240V,15A,50Hzelectricalservice with aserviceground
receptacle dedicated for use by this bath
6. AirMasseur®Equipment (120V,60Hz).
This AirMasseur®system comes equipped with an
Air On/Off switch and control box. The blower is pre-
wired with a 36" cord with a NEMA plug end. The air
switch control box and tubing is temporarily secured to
the bath’s plumbing for shipping. During installation the
tubing must be attached to the bath’s air switch actua-
tor and the air switch control box. The air switch control
box should be relocated to its dedicated circuit outlet.
Connect only to a dedicatedGFCI protected,120V, 15A,
60Hz circuit with a service ground. The air switch tubing
must be firmly attached to the air switch control box and
to the air switch actuator. A small bead of silicone may
be added to the air tubing connections to help prevent
the tubing from disengaging. The air switch tub-
ing must also be installed to allow for a “drop loop”
(See Figure 3c). This will prevent any moisture from
enteringtheairswitchcontrolboxfromthetubing.Finally,
the blower will plug into the control box.