INTRODUCTION
The LED Rechargeable Floodlights are available in 20W & 40W versions, offering up to
4000lm light output. The range is available with either one 22.2V battery or two 7.4V
batteries delivering runtime of up to seven hours from a 3-4 hour charge time per battery.
The product offers a powerful magnetic base for stability and flexibility when working and
has a hook design handle for adaptability in application. The range is suitable for complex
and hazardous working environments. and offers multiple brightness options of 50% and
100%.
JCB-FL20 JCB-FL20S
JCB-FL40 JCB-FL40S

3
JCB-FL20, JCB-FL20S, JCB-FL40, JCB-FL40S
Instruction Manual
SPECIFICATION
JCB-FL20 JCB-FL20S JCB-FL40 JCB-FL40S
Power Output 20W 20W 40W 40W
Lumen Output 1600lm 2000lm 2600lm 4000lm
Beam Angle 60º
IP Rating IP65
Charge Time 3-4 hours / battery
Run Time 3 Hours / 1 Batt.
5-6 Hours / 2 Batts.
6-7 Hours / 1 Batt. 1.5 Hours / 1 Batt.
3-4 Hours / 2 Batts.
3-3.5 Hours / 1
Batts
Input Voltage 100-240V, 50Hz
Material Iron Stand, Aluminium Alloy & Rubber Coated Head, PC Lens, 4mm Tempered Glass
LED 2x 1616 COB Chip 2x 1616 COB Chip 4x 1616 COB Chip 4x 1616 COB Chip
CRI 70Ra
Power Factor 0.9
Colour Temp 6500K
IK Rating IK09
Life Expectancy 20,000 Hours
Working Temp. -10ºC - 40ºC
Battery 2 x 7.4V 4.4Ah 1 x 22.2V 4.4Ah 2 x 7.4V 4.4Ah 1 x 22.2V 4.4Ah
PCB Protection Charging /
Discharging
Charging /
Discharging / High
Temp (70ºC)
Charging /
Discharging
Charging /
Discharging / High
Temp (70ºC)
Battery Indicator 5 Level Indicator – Green/Green/Green/Amber/Red
Dimensions W222 x D212 x
H358mm
W224 x D212 x
H335mm
W224 x D212 x
H335mm
W222 x D212 x
H358mm
Charger 12V, 1A 25.2V, 2A 12V, 1A 25.2V, 2A
Weight 2.5Kg 3Kg 2.5Kg 3Kg
Features • Battery indicator lights will turn off
one by one during discharge
• When the red indicator light flashes
the capacity is less than 5%
• Li-Ion battery with 100% / 50% /
Off switch
• USB output option
• Hook design handle
• A powerful base magnet allows
the product to be fixed to a metal
surface
• M10 nut for fixing onto a tripod

4JCB-FL20, JCB-FL20S, JCB-FL40, JCB-FL40S
Instruction Manual
JCB-FL20
AVERAGE ILLUMINATION
PLANAR INTENSITY DISTRIBUTION CURVE
Bare Lamp Photometric Data Page 1 Of
Goniophotometer Test Report
Measured Para U: 0.0V I: 0.0mA P: 0.00W PF: 0.000
Lamp Name:
Shape Size:
Sur(m^2):
Lamp Type:
Lamp Spec:
Manufactory:
Weight(kg):
Lamp ID:
Protect Angle(Deg):
ataD cirtemotohPataD ecruoS thgiL
Model
Nominal P(w)
Rated Flux(lm)
Illuminant QTY
Peak Value(cd)
Dw Flux Rate(%) Down(C180-C360)
Efficiency(lm/w)
UP(C0-C180)
UP(C180-C360)
0.0
0.0
Planar Intensity Distribution Curve
0
1596.9
9.740.001
0.0
0.0
0.0
Position 0.0,0.0
Up Flux Rate(%) 0.0
C0 Plane beam angle(50%):54.4(DEG) C90 Plane beam angle(50%):54.4(DEG)
C0 Pla n e b e a m angle(50%)
C90 Pl a ne bea m a n g l e ( 50%)
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
1,590
1,272
954
636
318
0
C Angle Range:0 - 180(Deg)
54 :)geD(lavretni C1 :)geD(lavretni amaG
Temperature(Deg): 27
Tester:
Test System: ZWL Goniophotometer System V3.0
Humidity(%): 50
Date: 2019-7-15
Gama Angle Range:-90 - 90(Deg)
:krameR070.01 :)m(ecnatsiD
4

5
JCB-FL20, JCB-FL20S, JCB-FL40, JCB-FL40S
Instruction Manual
JCB-FL20S
PLANAR INTENSITY DISTRIBUTION CURVE
AVERAGE ILLUMINATION
Bare Lamp Photometric Data Page 1 Of
Goniophotometer Test Report
Measured Para U: 0.0V I: 0.0mA P: 0.00W PF: 0.000
Lamp Name:
Shape Size:
Sur(m^2):
Lamp Type:
Lamp Spec:
Manufactory:
Weight(kg):
Lamp ID:
Protect Angle(Deg):
ataD cirtemotohPataD ecruoS thgiL
Model
Nominal P(w)
Rated Flux(lm)
Illuminant QTY
Peak Value(cd)
Dw Flux Rate(%)Down(C180-C360)
Efficiency(lm/w)
UP(C0-C180)
UP(C180-C360)
0.0
0.0
Planar Intensity Distribution Curve
0
1626.8
8.640.001
0.0
0.0
0.0
Position180.0,1.0
Up Flux Rate(%)0.0
C0 Plane beam angle(50%):55.4(DEG) C90 Plane beam angle(50%):55.7(DEG)
C0 Pl a n e b e am angle(50%)
C90 Plane b e a m angle(50%)
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
1,630
1,304
978
652
326
0
C Angle Range:0 - 180(Deg)
54 :)geD(lavretni C1 :)geD(lavretni amaG
Temperature(Deg): 27
Tester:
Test System: ZWL Goniophotometer System V3.0
Humidity(%): 50
Date: 2019-7-15
Gama Angle Range:-90 - 90(Deg)
:krameR070.01 :)m(ecnatsiD
4

6JCB-FL20, JCB-FL20S, JCB-FL40, JCB-FL40S
Instruction Manual
JCB-FL40
PLANAR INTENSITY DISTRIBUTION CURVE
AVERAGE ILLUMINATION
Bare Lamp Photometric Data Page 1 Of
Goniophotometer Test Report
Measured Para U: 0.0V I: 0.0mA P: 0.00W PF: 0.000
Lamp Name:
Shape Size:
Sur(m^2):
Lamp Type:
Lamp Spec:
Manufactory:
Weight(kg):
Lamp ID:
Protect Angle(Deg):
ataD cirtemotohPataD ecruoS thgiL
Model
Nominal P(w)
Rated Flux(lm)
Illuminant QTY
Peak Value(cd)
Dw Flux Rate(%) Down(C180-C360)
Efficiency(lm/w)
UP(C0-C180)
UP(C180-C360)
0.0
0.0
Planar Intensity Distribution Curve
0
2405.6
4.640.001
0.0
0.0
0.0
Position 180.0,3.0
Up Flux Rate(%) 0.0
C0 Plane beam angle(50%):57.9(DEG) C90 Plane beam angle(50%):54.8(DEG)
C0 Plane beam ang l e (50%)
C90 Plane b e a m a n g l e ( 50%)
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
2,410
1,928
1,446
964
482
0
C Angle Range:0 - 180(Deg)
54 :)geD(lavretni C1 :)geD(lavretni amaG
Temperature(Deg): 27
Tester:
Test System: ZWL Goniophotometer System V3.0
Humidity(%): 50
Date: 2019-7-15
Gama Angle Range:-90 - 90(Deg)
:krameR070.01 :)m(ecnatsiD
4

7
JCB-FL20, JCB-FL20S, JCB-FL40, JCB-FL40S
Instruction Manual
JCB-FL40S
PLANAR INTENSITY DISTRIBUTION CURVE
AVERAGE ILLUMINATION
Bare Lamp Photometric Data Page 1 Of
Goniophotometer Test Report
Measured Para U: 0.0V I: 0.0mA P: 0.00W PF: 0.000
Lamp Name:
Shape Size:
Sur(m^2):
Lamp Type:
Lamp Spec:
Manufactory:
Weight(kg):
Lamp ID:
Protect Angle(Deg):
ataD cirtemotohPataD ecruoS thgiL
Model
Nominal P(w)
Rated Flux(lm)
Illuminant QTY
Peak Value(cd)
Dw Flux Rate(%) Down(C180-C360)
Efficiency(lm/w)
UP(C0-C180)
UP(C180-C360)
0.0
0.0
Planar Intensity Distribution Curve
0
3414.9
4.850.001
0.0
0.0
0.0
Position 0.0,1.0
Up Flux Rate(%) 0.0
C0 Plane beam angle(50%):54.7(DEG) C90 Plane beam angle(50%):59.0(DEG)
C0 Pl a n e b e am angle(50% )
C90 Plane b e a m angle(50%)
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
3,410
2,728
2,046
1,364
682
0
C Angle Range:0 - 180(Deg)
54 :)geD(lavretni C1 :)geD(lavretni amaG
Temperature(Deg): 27
Tester:
Test System: ZWL Goniophotometer System V3.0
Humidity(%): 50
Date: 2019-7-15
Gama Angle Range:-90 - 90(Deg)
:krameR070.01 :)m(ecnatsiD
4

8JCB-FL20, JCB-FL20S, JCB-FL40, JCB-FL40S
Instruction Manual
SAFETY NOTICE
GENERAL
Ensure the worklight is correctly charged before initial use
DO NOT cover or block the lens during use
DO NOT shine the product directly into the eyes of people or animals
DO NOT allow children to use the worklight
DO NOT handle or move the worklight while it is being charged
DO NOT use the worklight if you suspect the battery or casing is damaged
DO NOT place the product in or near naked flames
DO NOT open the equipment or touch any of the internal parts
Ensure replacement batteries are genuine batteries of the same rating
Ensure the worklight is unplugged and allow to cool before attempting cleaning & maintenance
BATTERY
WARNING! To reduce the risk of fire or burns:
DO NOT attempt to open, disassemble, modify or service the battery
DO NOT expose to temperatures above 40ºC
DO NOT crush, puncture, short external contacts or dispose of in fire or water
DO NOT dispose of with regular waste - dispose of the old batteries in accordance with
local authority battery regulations
DO NOT cover the battery while charging
Ensure the charger is switched off and disconnected from the worklight before attempting
to open the lamp unit
Replace only with the batteries designated for this product
If the electrolyte in the cells comes into contact with the skin, wash thoroughly with soap
and water
If the electrolyte in the cells comes into contact with the eyes, rinse thoroughly with cold
water and seek immediate medical attention
Prior to use carry out the necessary risk assessment considering the people who could be
at risk, the level of risk and the precautions required to control the risk.

9
JCB-FL20, JCB-FL20S, JCB-FL40, JCB-FL40S
Instruction Manual
SAFETY NOTICE
ELECTRICAL
WARNING! It is the user’s responsibility to read, understand and comply with the
following electrical instructions:
Ensure the risk of electrical shock is minimised by the installation of appropriate safety
devices
Inspect the charger plug, cable and connection for wear and damage to ensure the items
are safe before connecting to the mains power supply
DO NOT use if worn or damaged
Check cables are always protected against short circuit and overload
IMPORTANT! Check that the voltage marked on the charger plug is the same as the
power supply to be used
Uncoil the cable between charger and the worklight
DO NOT use any other type of charger with this product
DO NOT place the connector into any area of the worklight except the correct inlet
socket
DO NOT try to take the charger plug apart
DO NOT use the charger plug to charger or power any other electrical items
DO NOT wet the charger or use in wet or damp conditions (indoor use only)

10 JCB-FL20, JCB-FL20S, JCB-FL40, JCB-FL40S
Instruction Manual
OPERATION
CHARGING WARNING! Ensure that you read and fully understand the safety
instruction before use
Charge the batteries before use
IMPORTANT! Ensure the worklight is turned OFF while charging. Failure to do so will
damage the charger plug/vehicle plug
Connect the charging plug into the charging socket located on the rear of worklight
Connect the 230V charger or 12-24V DC charger to a power supply
The LED battery indicator will flash whilst charging and remain constant when fully charged
Disconnect the charger from the worklight when it is fully charged and replace the dust cap
DO NOT shine the product directly into the eyes of people or animals
MAINTENANCE & STORAGE
When not in use store the product in a safe, clean, dry environment out of the reach of
children
Keep the worklight clean from dirt and grease using a damp cloth
DO NOT submerge in water
DO NOT clean the worklight with solvents
Check the product for damage before each use

11
JCB-FL20, JCB-FL20S, JCB-FL40, JCB-FL40S
Instruction Manual
GUARANTEE
This product is guaranteed against manufacturing defects for a period of 3 years from the
date of purchase.
Repair or replacement of products will be undertaken providing that:
• The product has been subject to fair wear and tear only
• The product has not been subject to accidental or cosmetic damage
• The product has not been misused and has been used only in accordance with the
instruction manual provided
• The product has not been subject to insufficient servicing and maintenance
• The product has not been subject to any abnormal environmental conditions or
inappropriate operating conditions
• Repairs have not been attempted by an unauthorised person and no modifications
have been made to the product
The guarantee excludes the following (where relevant):
• Components normally subject to wear and tear
• Batteries and chargers
Your statutory rights are not affected.
We reserve the right to alter specifications without prior notice.
WE WILL NOT BE LIABLE FOR ANY INJURIES OR CONSEQUENTIAL
DAMAGES RESULTING FROM THE USE OF THIS PRODUCT

12 JCB-FL20, JCB-FL20S, JCB-FL40, JCB-FL40S
Instruction Manual
NOTES
This manual suits for next models
3
Table of contents
Other jcb Work Light manuals

jcb
jcb JCB-IT30 User manual

jcb
jcb JCB-WL-TUFFXONE User manual

jcb
jcb JCB-WL-POCKET II Planning guide

jcb
jcb JCB-PT5S User manual

jcb
jcb JCB-PL10 User manual

jcb
jcb JCB-SL-KONNECT 6500 Planning guide

jcb
jcb 21-18IL Planning guide

jcb
jcb JCB-WL-TUFFCLAMP Planning guide

jcb
jcb JCB-FLH40 User manual

jcb
jcb JCB-WL-POCKET User manual
Popular Work Light manuals by other brands

Techly
Techly LED LAMP Series user manual

Vigor Equipment
Vigor Equipment V5500 operating instructions

V-TAC
V-TAC VT-8500 installation instructions

brennenstuhl
brennenstuhl ML DA 1206 DE 3993 operating instructions

Qlightec
Qlightec QLEX-350 quick start guide

Acclaim Lighting
Acclaim Lighting RGBX-DRUM-HIP Specifications