Configuration
By default, PAD is set with the Wiegand 26 protocol with a 4-digit PIN.
Default master code: 000000
Wiegand34 selection
•Hold the "B" key down until you hear 3 beeps.
•Master code (by default: 000000) →Orange LED activated.
•Press 6.
•Press 2.
•Press A →Orange LED deactivated.
Change PIN length
Example 8-digit PIN:
•Hold the "B" key down until you hear 3 beeps.
•Master code (by default: 000000) →Orange LED activated.
•Press 4.
•Press 8.
•Press A →Orange LED deactivated.
Notes:
•Option 4-6: 6-digit PIN (recommended for WG26).
•Option 4-9: 9-digit PIN (recommended for WG34).
•Option 4-0: PIN for any length (not recommended).
•If you want to work without a limitation on duration, consider these restrictions (Warning: with these modes, higher val-
ues will cause double codes):
•WG26 →maximum value = 16,777,215
•WG34 →maximum value = 4.294,967,295
•Caution: values higher than the maximum value will lead to repeated codes when the device decodes the PIN.
•In this mode, you must press "A" to send the PIN you have entered.
Change master code
•Hold the "B" key down until you hear 3 beeps.
•Master code (by default: 000000) →Orange LED activated.
•Specify the new master code (6 digits).
•Press A →Orange LED deactivated.
Restart the factory master code
•Disconnect from power source.
•Hold the "A" key down and reconnect to power source.
•Hold the "A" key down for at least 2 seconds.
•You will hear 3 beeps.