Joy-it VAX-1100 User manual

VAX-1030 & VAX-1100
Multifunction meter for the measurement of direct current circuits
1. GENERAL INFORMATION
Dear customer,
thank you for choosing our product. In the following, we will show you how
to use your product.
Should you encounter any unexpected problems during use, please do not
hesitate to contact us.
The measuring instruments of the VAX series are multimeter which
transmit the measurement results to the display via a wireless 2.4 GHz
technology. A TFT-LCD shows the measured values clearly and enables a
comfortable operation.
The measuring instruments are safeguarded against overvoltage,
undervoltage and overcurrent. In operation with batteries, these devices
can detect automatically the direction of the current ow and displays the
battery capacity in real time.

2. TECHNICAL SPECIFICATIONS
Model VAX-1030 VAX-1100
Measuring range voltage
Resolution voltage
Measuring range current
Resolution current
Relay
0 - 100 V
0,01 V
0 - 100 V
0,01 V
0 - 100 A0 - 30 A
0,01 A
Internal
0,1 A
External (optional)
Measuring range
temperature -20 - 120 °C
0 - 100 %
0 - 200 kW
0,001 W
0 - 2000 AH
0,001 AH
0 - 4000 kWH
0,001 WH
0 - 99 days
1 seconds
± 2 % + 3 digits
± 5 % + 10 digits
5 Hz
Up to 10 m
ca. 0,4 W
Charge indicator
Measuring range power
Resolution power
Measuring range
ampere hours
Resolution ampere hours
Measuring range
watt-hours
Resolution watt-hours
Measuring range time
Resolution time
Accuracy voltage
Accuracy current
Sampling rate
Range, wireless
Power consumption
measuring instrument
Power consumption
display
NCP
OCP
OVP
LVP
delay of
protection settings
0,5 W
0 - 300 A (setting of negative overcurrent protection)
0 - 300 A (setting of overcurrent protection)
0 - 100 V(setting of overvoltage)
0 - 100 V(setting of undervoltage)
0 - 10 s

3. DIMENSIONS IN MM
4. DISPLAY
The measuring instrument can be connected with the display via a cable or
wireless.
If the connection is wireless, there are two opportunities to power the
display. You can use the mUSB port (5 V) or the JST port (8 - 16 V).
mUSB port JST port

VAX-1030
signal
power key lock relay address
charge status (for batteries)
voltage
current
output
ampere hours
watt-hours
time
negative overcurrent protection
overcurrent protection
undervoltage protection
overvoltage protection
output (relay)
resetting
charge status
system settings
address settings
channel setting
language setting
5. CONNECTION
If the instrument is integrated in the circuit like in the le illustration, it is
possible to measure DC current circuits and the discharge of batteries.
If the instrument is integrated in the circuit like in the right illustration, you
can measure the charging process of batteries.
power
source load battery charger

VAX-1100
For a measuring range from 10 to 100 V, the instrument must be connected
like that:
These illustrations display how the VAX1100 must be connected for a
measuring range from 10 to 100 V. Please note that the jumper must be
pinned on position 2W .
If the instrument is integrated in the circuit like in the le illustration, it is
possible to measure DC current circuits and the discharge of batteries.
If the instrument is integrated in the circuit like in the right illustration, you
can measure the charging process of batteries.
For a measuring range from 0 to 100 V, the instrument must be connected
like that:
These illustrations display how the VAX1100 must be connected for a mea-
suring range from 0 to 100 V. Please note that the jumper must be pinned
on position 3W. Moreover, the measuring module must be supplied
with a 10 to 30 V DC voltage.
If the instrument is integrated in the circuit like in the le illustration, it is
possible to measure DC current circuits and the discharge of batteries.
If the instrument is integrated in the circuit like in the right illustration, you
can measure the charging process of batteries.
power
source
power
source
load
load
battery
battery
charger
charger

Connection between a relay and the VAX1100
You must note among the usage with a relay that the relay must be
designed for the expected voltage and current in that specic
construction.
There are displayed 3 possible symbols which are designed for the
verication of the connection. These symbols have this meaning:
6. OPERATION
Wireless connection is successfully established
Corded connection is successfully established
Connection failed or is not connected
Key Function
“OUT“ Hereby, you can switch the output. In order that it
works, the relay must be controlled.
“NCP“
Hereby, the protection against the negative current
can be activated. With “OK“ you can change the
value, if the value is “0“, the function is deactivated.
This function shis the relay to interrupt the circuit.
“OCP“
Hereby, the protection against overcurrent can be
activated. With “OK“ you can change the value, if the
value is “0“, the function is deactivated. This function
shis the relay to interrupt the circuit.
power
source load battery charger

“LVP“
Hereby, the undervoltage protection can be
activated. With “OK“ you can change the value, if the
value is “0“, the function is deactivated. This function
shis the relay to interrupt the circuit.
“OVP“
Hereby, the overvoltage protection can be activated.
With “OK“ you can change the value, if the value is
“0“, the function is deactivated. This function shis
the relay to interrupt the circuit.
“CLR“ This buttons deletes all saved values of Ah, Wh and
time. Additionally, the battery status is set on 100 %.
“BAT“ You can adjust here the values of the battery with this
button.
“SET“ You can adjust here the fundamental setteings of the
device.
“ADR“ With “ADR“ the communication address can be
adjusted.
“FCH“ With “FCH“ the communication channel can be
adjusted.
“BRI“ You can adjust here the brightness of the display.
“LNG“ You can change here the language.
Important: To go to the “LNG“ option, you must enter “ADR“ and hold down
the down arrow key for 3 seconds.
7. CONNECTING SEVERAL DEVICES TO ONE DISPLAY
To connect several devices to one display, you must rst assign dierent
addresses to the devices.
1. To do this, connect your display to your device using the USB cable.
2. Now open the menu by pressing the OK key.
3. Use the arrow keys to navigate to the ADR. menu item and press the OK key.
4. Now you can select the address with the arrow keys. By changing the
address you should now see the following symbol in the upper le corner of
the display:
5. To conrm the address, press and hold the OK button for about three
seconds.
6. If you now release the key, the display should change and the following
symbol appears:
In this way, you can assign dierent addresses to each device.

9. SUPPORT
If any questions remain open or problems arise aer your purchase, we are
available by e-mail, telephone and with a ticket support system to answer
these.
E-Mail: servic[email protected]
Ticket-System: http://support.joy-it.net
Telephone: +49 (0)2845 98469 – 66 (10 - 17 o‘clock)
For further information visit our website:
www.joy-it.net
www.joy-it.net
SIMAC Electronics GmbH
Pascalstr. 8 47506 Neukirchen-Vluyn
Published: 01.10.2020
8. DECLARATION OF CONFORMITY
Hereby, the Simac Electronics Handel GmbH declares that the radio
equipment type COM-VAX1030 and COM-VAX1100 are in compliance with
Directive 2014/53/EU. The full text of the EU declarations of conformity are
available at the following internet addresses:
www.simac-gmbh.de/CE/com-vax1030.pdf
www.simac-gmbh.de/CE/com-vax1100.pdf
Information on transmission power and frequency band of COM-VAX1030:
Frequency band: 2412-2472 MHz
Max. transmisson power: 11,67 dBm
Information on transmission power and frequency band of COM-VAX1100:
Frequency band: 2412-2472 MHz
Max. transmisson power: 11,67 dBm
In order to control the individual devices wirelessly, the address of your
display and that of the device you want to control must match.
1. To do this, connect the display to a voltage source.
2. Now open the menu by pressing the OK key.
3. Use the arrow keys to navigate to the ADR. menu item and press the OK key.
4. You can now select the address with the arrow keys.
5. To conrm the address, press the OK button.
If the wireless connection is successful, you should see the following symbol in
the upper le corner of your display:
This manual suits for next models
3
Table of contents
Other Joy-it Measuring Instrument manuals

Joy-it
Joy-it JT-TC66C User manual

Joy-it
Joy-it JT-DMSO2D72 User manual

Joy-it
Joy-it VM-533 User manual

Joy-it
Joy-it 2860-JT-LCRT7 User manual

Joy-it
Joy-it SEN-HX711 User manual

Joy-it
Joy-it JT-AT34 User manual

Joy-it
Joy-it COM-KY051VT User manual

Joy-it
Joy-it VM-433 User manual

Joy-it
Joy-it JT-UM25C User manual

Joy-it
Joy-it VAX-1030 User manual