JOYTECH PY1400ACL User manual

PY1400ACL
Sliding Gate Opener
User Manual
2017

Dear users,
Thank you for choosing this product. Please read the manual carefully before assembling and using it.
Please do not leave out the manual if you send this product to a third party.
1. Safety Instruction
Please ensure that the using power voltage matches with the supply voltage of gate opener
(AC110V or AC220V); kids are forbidden to touch the control devices or the remote-control unit.
The remote-control unit is controlled by a single button mode. The indicator light on the
remote-control unit will flicker when the button on it is pressed. Main engine and gate can be
unlocked by disengagement wrench and the gate can move with manual operation after
disengagement.
Please ensure that no one is around the main engine or gate when the switch is operated and it is
usually demanded to examine the stability of installation. Please temporarily stop using if the main
engine needs repairing or regulation.
The installation and maintenance of the products must be carried out by professionals.

2. Packing List (standard)
No.
Picture
Name
Quantity
1
Main engine
1
2
Manual release bar
1
3
A
B
C
D
A
B
C
D
Remote control
2
4
Mounting accessories box
1
4-1
Sprocket cover
1
4-2
Chain link
2
4-3
Chain
6m
4-4
Tie rod
2
4-5
Square screw
4
4-6
Round screw
4

No.
Picture
Name
Quantity
4-7
Door connecting plate
2
4-8
Horizontal mounting plate
2
4-9
Vertical mounting plate
2
4-10
Foundation bolt M8
4
4-11
or
Magnetic or Spring limit
switch block
1
4-12
Inner hexagon screw
M6×20
8
4-13
Hexagon screw M6×65
4
Hexagon screw M8×25
4
4-14
Nut M6
20
Nut M8
16
4-15
Flat washer φ6
20
Flat washer φ8
16
4-16
Spring washer φ6
20
Spring washer φ8
12

2. Packing List (optional)
No.
Picture
Name
Quantity
1
Infrared sensor
1
2
0
8
5 6
97
4
1 2 3
Wireless keypad
1
3
Alarm lamp
1
3. Technical parameters
Model
PY1400ACL
Power supply
220V/50Hz;110V/60Hz
Motor power
500W
Gate moving speed
12m/min
Maximum weight of gate
1400Kg
Remote control distance
≥30m
Remote control mode
Single button mode
Limit switch
Spring limit switch
/ Magnetic limit switch
Noise
≤60dB
Working duty
S2, 15min
Recording of up remote controls
25
Frequency
433.92 MHz
Working temperature
-20°C ~ +70°C
Package weight
26.5Kg
4. Installation
PY800ACL/PY1400ACL sliding gate opener is applicable to gate weight less than 800kg/1400kg,
and length of the sliding gate should be less than 14m/20m. The drive mode adopts the gear and
rack transmission. This gate opener must be installed inside the enclosure or yard for protection.
4.1 Installation drawing

⑤
④
③
②
0
8
5 6
97
4
1 2 3
⑧
①
⑦
⑥
Figure 1
①Gate opener; ②Wireless keypad (optional); ③Gate; ④Infrared sensor (optional);
⑤Alarm lamp (optional); ⑥Safety stop block; ⑦Chain; ⑧Remote control;
4.2 Size of main engine and accessories
4.2.1 Size of main engine
340 288
530
Figure 2

4.2.2 Size of embedded hole
305
139
Figure 3
4.3 Installation procedures
4.3.1 Preparation work before installation
Please ensure that the sliding gate is correctly installed, the gate rail is horizontal, and the gate can
glide back and forth smoothly when moved by hands before installing the gate opener.
Cable installation
Please bury the motor & power cable and controlling cable with PVC tube, and use two PVC tubes
to bury (motor & power cable) and (controlling cable) separately, so as to guarantee normal
operation of the gate opener and protect the cables from damages.
Concrete pedestal
Please cast a concrete pedestal with the size of 550mm x 400mm and depth of 200mm in advance,
so as to firmly install PY800ACL/PY1400ACL gate opener. Please verify whether the distance
between the gate and gate opener is suitable before casting the pedestal.
Embedded screws
Concrete
Power line
Mounting base
Foundation bolt
Figure 4

4.3.2 Main engine installation
a) Dismantle the plastic housing on the main engine before installation and keep relevant fasteners
properly;
b) If select the detachable mounting base, the base should be assembled first as shown in Figure 5;
InnerInner hexagonhexagon screwscrew M6×20M6×20
VerticalVertical mountingmounting platenplaten
HorizontalHorizontal mountingmounting plateplate
NutNut M6M6
SpringSpring washerwasherφ6
FlatFlat washerwasherφ6
Figure 5
c) Assemble the machine engine to the mounting base as shown in Figure 6;
MountingMounting basebase
HexagonHexagon screwscrew M8×25M8×25
FlatFlat washerwasherφ8
SpringSpring washerwasherφ8
NutNut M8M8
Figure 6
d) Please prepare the power line for connecting mounting plate and main engine (the number of
power supply cable core shall not be less than 3 PCS, the sectional area of cable core shall not be

lower than 1.5mm² and the length shall be determined by users according to the field situation) due
to different installation environments;
e) Please unlock the main engine before installation, the unlock method is: take out the key cover,
insert the key, and open the manual release bar till it rotates by 90° as shown in Figure 7. Then turn
the output sprocket and the sprocket can be rotated easily;
Rotate
Figure 7
4.3.3 Chain installation
Close the gate; connect the tie rod with chain through chain link; fasten the tie rod to the door
connecting plate by washers and nuts as shown in Figure 8. If necessary, the elasticity of chain can
be adjusted through the tie rod at both ends as shown in Figure 9 and 10. If necessary, the chain
can be shortened. If it need to be lengthened, make sure to use same type of chain.

ChainChain ChainChain linklink
TieTie rodrod
Figure 8
If door frame is round, please use the round screw as shown in Figure 9:
Gate Round screw
Spring washerφ8
Nut M8
Flat washerφ8
Tie rod
Nut M6
Spring washerφ6
Flat washerφ6
Figure 9
If door frame is square, please use the square screw as shown in Figure 10:
Gate Square screw
Spring washerφ8
Nut M8
Flat washerφ8
Tie rod
Nut M6
Spring washerφ6
Flat washerφ6
Figure 10

Installation of chain, small and big sprocket as shown in Figure 11:
Figure 11
Installation of sprocket cover as shown in Figure 12:
CrossCross screwscrew M4×10M4×10
SprocketSprocket covercover
Figure 12

The distance between main engine and chain ends should be at least 30CM, as shown in Figure 13:
.
≥30CM≥30CM
Figure 13
Warnings
·To ensure safety, install safety stop blocks on both ends of the rails to prevent the gate out of the rail.
Before installing the main engine, make sure that the safety stop blocks are in place and whether it
has the function of preventing the gate from moving out of the rail and out of the safety range.
·Please ensure that the main engine and its components have good mechanical properties, and the
gate can operate flexibly when moved by hands before installing the main engine.
·In this product, one control can drive one main engine only, otherwise, the control system will be
damaged.
·Earth leakage circuit breaker must be installed where the gate movement can be seen, and the
minimum mounting height is 1.5m to protect it from being touched.
·After installation, please check whether the mechanical property is good or not, whether gate
movement after manual unlocking is flexible or not, and whether the infrared sensor (optional) is
installed correctly and effectively.
4.3.4 Limit switch adjustment
Insert the manual release bar and rotate it clockwise to unlock the gate opener, manually move the
gate to the predetermined position; fix the magnetic limit switch block and rotate the manual release
bar anticlockwise to close the clutch; testing run after power on, slightly adjust the position of the
magnetic limit switch block until the gate reaches the desired open and close limit location.

Installation of Spring limit switch bock:
GateGate
SpringSpring limitlimit
switchswitch blockblock
ChainChain
HexagonHexagon screwscrew
M6M6 × 6565
4545
Figure 14
GateGate
MainMain engineengine
ChainChain wheelwheel
ChainChain
SpringSpring limitlimit switchswitch blockblock
SpringSpring
Spring washerφ8
Nut M8
Flat washerφ8
Figure 15

Installation of magnetic limit switch bock:
103103
4141
GateGate
MagnetMagnet
MagneticMagnetic limitlimit switchswitch blockblock
ChainChain
Figure 16
≤20mm
GateGate
MainMain engineengine
chainchain wheelwheel
ChainChain
MagneticMagnetic limitlimit switchswitch blockblock
MagnetMagnet
Spring washerφ8
Nut M8
Flat washerφ8
Figure 17
Note: The default setting is right side mounting. (According to actual situation, please refer to the
“Note” of section 4.3.5.1 and 4.3.5.2 “Adjustment and operation” to adjust.)

4.3.5 Control board wiring
4.3.5.1 Standard control board
+
+
O
+
24VDC24VDC
GNDGND
I.RI.R
CLLMCLLM
COMCOM
OPLMOPLM
COMCOM
STPSTP
X5X5
10A10A 250V250V
CLSCLS
OPNOPN
X1X1
W U V PEPE
D2D2 D1D1 C C
SW1SW1
ONON
AN1AN1
LED1LED1
X2X2X3X3
PEPE N L
X8X8
M
24VDC24VDC
GNDGND
PowerPower
LampLamp CapacitorCapacitor
InfraredInfrared sensorsensor
LimitLimit switchswitch
EarthEarth
LED2LED2
ExternalExternal buttonbutton
switchswitch
X7X7
MotorMotor
Figure 18
Wiring instruction:
1. Connect L and N to the power supply of AC220V/50HZ; AC110V/60HZ; L is live wire, N is
Neutral wire, and PE is grounding wire.
2. Connect LAMP to D1, D2; voltage: AC220V/50HZ; AC110V/60HZ.
3. Connect the motor wire U to the REV motor wire, connect W to the FWD motor wire, and
connect V to the motor common wire.
4. Connect C, C to the capacitor wire.
X5 Terminal
24VDC Power supply for fittings +24VDC(Electric current ≤50mA);
GND Power ground;
I.R Photocell input (N.C.);
CLLM Close limit switch;
COM Limit switch common terminal;
OPLM Open limit switch.
X7 Terminal
COM Control button common terminal;
STP Stop control button (N.O.);
CLS Gate close control button (N.O.);
OPN Gate open control button (N.O.).

DIP Switch
1. External button switch. ON - Three button switch; OFF - One button switch (X7 terminal CLS
button can be used to circularly control the main engine OPEN/STOP/CLOSE/STOP).
2. Automatic close time.
3. Automatic close time.
2 ON 3 OFF: automatic close time is 15s,
2 OFF 3 ON: automatic close time is 30s,
2 OFF 3 OFF: automatic close time is 45s,
2 ON 3 ON: no automatic close function.
Infrared connection
Infrared photocell function: In the closing process, when infrared ray of the infrared sensor is
covered, the gate will open immediately, to protect user and property security.
The distance between photocell receiver and photocell emitter should be not less than 2 meters,
otherwise will affect the induction of the photocell.
If connect the infrared photocell, please remove the short connection between I.R and GND on the
X5 terminal.
24VDC24VDC
GNDGND
I.RI.R
CLLMCLLM
COMCOM
OPLMOPLM
COMCOM
STPSTP
X5X5
10A10A 250V250V
CLSCLS
OPNOPN
X1X1
PEPE N L
X8X8
ComCom OutOut
SetSet NCNC
InfraredInfrared receiverreceiver connectingconnecting
- +
- +
X7X7
InfraredInfrared emitteremitter connectingconnecting
Figure 19

Adjustment and operation
Remote control operation
Remote control is single button mode, one same button on the remote control to circularly control
the main engine OPEN/STOP/CLOSE/STOP.
A
B
C
D
CLOSECLOSE
OPENOPEN
STOPSTOP
Figure 20
Add extra remote control (remote control learning): Remove the upper cover of main engine,
remove the upper cover of the control box, press the learning button AN1 on the control board, and
indicator light LED2 will flash once and then go out; press the same button on the remote control
twice, the LED2 flashes repeatedly and then goes out; remote control learning is succeed. At most
25 remote controls can be learned.
Delete remote control: Delete remote control that have been learned; press the learning button
AN1 and LED2 will be on; loosen the button until LED2 is off. This indicates that all remote controls
that learned previously have been deleted.
Note: To disengage gate opener, move the gate to the middle position, then close the clutch and
press the open button of external button switch to open the gate. If the gate opening direction is
wrong, can through the toggle switch SW1 on the control board or exchange the two motor
lines U and W. Please seriously observe whether the motor can stop automatically when the
gate fully opened. If the position cannot be limited correctly, please exchange limit switch
lines CLLM and OPLM.

4.3.5.1 Intelligent control board
L
PEPE
1313
LAMPLAMP PEPE
32
1456791010 1111 1212
8
MOTMOT
MOTMOT
COMCOM
MOT1MOT1
MOT2MOT2
CAPCAP
SPEEDSPEED GNDGND VCCVCC
N
L N
OFFOFF
ONON
X1X1
J5J5
U1U1
HALLHALL
J2J2
U2U2
S1S1
VR3VR3 VR4VR4
LEARNLEARN
POWERPOWER
J1J1
J6J6
J3J3
1313
1111
5 6
VR1VR1 VR2VR2
81010
SW1SW1
1 2 3
J4J4
12VDC12VDC
GNDGND
LimitLimit switchswitch
LoopLoop detetcordetetcor
O/S/CO/S/C switchswitch
ExternalExternal buttonbutton
PedestrianPedestrian switchswitch
M
PowerPower
EarthEarth
CapacitorCapacitor
LampLamp
HallHall lineline
InfraredInfrared sensorsensor
switchswitch
Figure 21
Wiring instruction:
1. Connect L and N to the power supply of AC220V/50HZ; AC110V/60HZ; L is live wire, N is
Neutral wire, and PE is grounding wire.
2. Connect LAMP to caution light; voltage: AC220V/50HZ; AC110V/60HZ.
3. Connect the motor wire MOT2 to the REV motor wire, connect MOT1 to the FWD motor wire,
and connect MOTCOM to the motor common wire.
4. Connect MOTCAP to the capacitor wire.
J2 (For the convenience of wiring, this terminal is accompanied with failure diagnosis light)
1. Gate close control button (N.O.)
2. Gate open control button (N.O.)
3. Stop control button (N.O.)
4. Control button common terminal
5. Open/Stop/Close/Stop loop control button (N.O.)
6. Pedestrian mode control button (N.O.)

J5 (For the convenience of wiring, this terminal is accompanied with failure diagnosis light)
7. Power supply for fittings: +12V(Electric current ≤100mA)
8. Photocell input (N.C.); short out the device if not used.
9. GND
10. Loop detector (sensor coil) connector (N.O.)
In the closing process, once vehicles are detected by the loop detector, the gate will open
soon; when the vehicle passes, the gate will close automatically. When the gate is in a
halted state, it will keep this state when vehicles are detected; after the vehicle passes, the
gate will close automatically.
In the above loop detector function, users can make the gate close automatically 12
seconds later after the vehicle passes. Change the No.4 key of the dip switch on circuit
board, and the gate will close automatically 12 seconds later after the vehicle passes.
11. Close limit switch
12. Limit switch and other input signal common terminal
13. Open limit switch
Function adjustment
Functional parameters of the control board equipped with microprocessor can be adjusted through
potentiometer and dip switch, so as to meet different installation requirements.
1313
1212 SPEEDSPEED GNDGND VCCVCC
OFFOFF
ONON
X1X1
HALLHALL
U2U2
S1S1
VR3VR3 VR4VR4
LEARNLEARN
POWERPOWER
J1J1
1313
VR1VR1 VR2VR2
SW1SW1
1 2 3 4 5
Figure 22
Adjusting knob
VR1: When meet obstacle reverse function is enabled (DIP switch 5 at OFF position and the motor
assembled the hall line).This knob is used for sensitivity adjustment of meet obstacle.
Clockwise rotation to reduce sensitivity of obstacle, counter-clockwise rotation to increase sensitivity
of obstacle.
When meet obstacle reverse function is disabled (DIP switch 5 at ON position). This knob is used for
motor working total time adjustment. Clockwise rotation to increase, counter-clockwise rotation to
reduce. The total time can be set to 10 seconds as minimum and 90 seconds as maximum.
VR2: For brake force adjustment in limit position.
Clockwise rotation to increase, counter-clockwise rotation to reduce.
Rotate to minimum to cancel brake function in place.
VR3: For slow stop width adjustment.
Clockwise rotation to increase, counter-clockwise rotation to reduce.

VR4: For motor output force adjustment to keep safe usage.
Clockwise rotation to increase, counter-clockwise rotation to reduce.
Note: the default setting is VR1, VR2, VR3, VR4 are the maximum value, and the user can adjust
according to the actual requirement.
Warning: the motor output force cannot set too large, just to be able to drive the gate.
Dip switch
1. Soft start function. OFF - enabled; ON - disabled.
2. Limit switch setting. OFF- normal open (N.O.); ON - normal close (N.C.).
3. Automatic close time.
4. Automatic close time.
Setting for automatic close time:
3 OFF 4 ON: automatic close time is 12s,
3 ON 4 OFF: automatic close time is 24s,
3 ON 4 ON: automatic close time is 36s,
3 OFF 4 OFF: no automatic close function.
5. Meet obstacle reversal function. OFF - enabled; ON - disabled.
Infrared connection
Infrared photocell function: In the closing process, when infrared ray of the infrared sensor is
covered, the gate will open immediately, to protect user and property security.
The distance between photocell receiver and photocell emitter should be not less than 2 meters,
otherwise will affect the induction of the photocell.
If connect the infrared photocell, please remove the short connection between 8 and 9 on the J5
terminal.
1313
791010 1111 1212
8SPEEDSPEED GNDGND VCCVCC
OFFOFF
ONON
X1X1
J5J5
U1U1
HALLHALL
U2U2
S1S1
VR3VR3 VR4VR4
LEARNLEARN
POWERPOWER
J1J1
1313
1111
VR1VR1 VR2VR2
81010
SW1SW1
ComCom OutOut
SetSet NCNC
InfraredInfrared receiverreceiver connectingconnecting InfraredInfrared emitteremitter connectingconnecting
- +
- +
Figure 23
Table of contents
Other JOYTECH Gate Opener manuals

JOYTECH
JOYTECH PY800AC User manual

JOYTECH
JOYTECH PK300DC User manual

JOYTECH
JOYTECH SL1000AC User manual

JOYTECH
JOYTECH PY500AC User manual

JOYTECH
JOYTECH SL1000AC User manual

JOYTECH
JOYTECH SW300DC User manual

JOYTECH
JOYTECH SL500DC User manual

JOYTECH
JOYTECH PY300DC User manual

JOYTECH
JOYTECH PY800AC User manual

JOYTECH
JOYTECH PY500AC User manual
Popular Gate Opener manuals by other brands

fadini
fadini Bart 350 instruction manual

DITEC
DITEC 0DT869 Installation manual, maintenance, use

Topens
Topens JY9132 user manual

GiBiDi
GiBiDi PLUS-1 Connecting Instructions

Nice
Nice Wingo 5024 Kit Instructions and warnings for installation and use

Allstar