K-array Redline KR100S User manual

K-array is the new voice that sings
aloud, "outside the choir", and whose
performance is better than any other
products. Born on-the-road, in the PA
world, where you get no discount, you
have to give your best as fast as you
can, often with a "compressed" budget,
K-Array systems have been designed to
give precise answers to precise needs.
Driven by new generation digital
engines, with power/dimension/weight
ratios that are ten times better than any
other professional products, K-arrays
can deliver the full spectrum of musical
styles with clarity, power, punch,
intelligibility and evenness across both
volume levels and the frequency
spectrum. These systems can be
remotely controlled and come with a
sophisticated on-board software,
allowing the user to shape their
performance to taste and needs. Inside
K-array systems you will find something
that only we can offer: the best in
t e c h n o l o g y, p r o u d l y c o n c e i v e d ,
designed and produced in Italy. If they
were cars, they would be Ferrari. Don't
agree to pay for a simple brand, claim
performance, and don't believe those
who maintain that these products are
only for few people, the only truth is that
K-array systems are unique, but
affordable and within everybody's
reach!
HP Sound Equipment s.r.l.
ENGLISH
USER'S MANUAL
USER'S MANUAL
REV.05

SYMBOLS
1. SAFETY INSTRUCTIONS
!
This symbol, wherever it appears, alerts you to
important operating and maintenance istructions in
the accompanying literature. Read the manual!
Dangerous voltages: risck of electric shock.
For information about the disposal of Waste Electrical
and Electronic Equipment (WEEE), please refer to the
website at
www.scanning.datalogic.com
This symbol alerts the user to the presence of
re c om m en d at i on s a bo u t pr o du c t' s u se a n d
maintenance.
CAUTION !
!
• To reduce the risk of electric shock, disconnect the amplifier from the AC mains before installing audio cable.
Reconnect the power cord only after making all signal connections.
• Connect the amplifier to a two-pole, three wire grounding mains receptacle. The receptacle must be connected to
a fuse or circuit breaker. Connection to any other type of receptacle poses a shock hazard and may violate local
electrical codes.
• Do not install the amplifier in wet or humid locations without using weather protection.
• Do not allow water or any foreign object to get inside the amplifier. Do not put objects containing liquid on, or near,
the unit.
• To reduce the risk of overheating the amplifier, avoid exposing it to direct sunlight. Do not install the unit near heat
emitting appliances, such as a room heater or stove.
• No naked flame sources such like lighted candles should be placed on the device.
• The amplifier should be placed so that its location does not interfere with its proper ventilation. For example, the
appliance should not be situated on a bed, carpet, or similar surface that may create an obstacle for the ventilation
openings.
ENGLISH
USER'S MANUAL
REV.05 pag. 02

2. INTRODUCTION
3. VOLTAGE REQUIREMENTS
KA 10 operates safely and without audio discontinuity if the AC voltage stays within either of two operating
windows: 95-125 (voltage selector on 115 V) or 195-250 V (voltage selector on 230 V), at 50 or 60 Hz.
115-230
Connecting a 115V system on a 230V AC Power causes heavy
damages to the device and serious risk for users .
CAUTION
!
The device is default set to be connected to 230 V AC Power. To use the device on a 115 V AC Power you need,
before connecting it, to move the voltage selector's cover, just loosening the two screws, and to choose the correct
use voltage by the red switch. Be sure that both voltage set on the selector and AC Power have the same value .
Always close the voltage selector's cover before connecting the device to AC Power. Change the label that points
out the correct voltage in use.
ENGLISH
USER'S MANUAL
REV.05 pag. 03
The KR100S is a high performance ultra-slim powered two way system designed for use with small to medium wavefront
systems, in both mobile and install applications. The KR100S includes two KL12ma powered subwoofers and 2 KR100 1mt
line array satellites.
KL12ma features a 1000 watt 12" drive unit with magnet structure and suspension engineered for maximum linear
excursion.
The ultra-light reflex cabinet is fitted with two pocket handles and one 35mm pole mounting point for easy installation with
every satellite speaker on it. It features large area porting to reduce air noise. KR100S ultra-slim satellite features a line
array of 2" high efficiency drive units with neodymium magnet structure and suspensions engineered for maximum linear
excursion and minimum noise problems. The ultra-strong chassis ensures high resistance and durability also with hardest
work conditions. KR100S
The
The
All the components are designed by K-array R&D department and custom made under K-array
control quality system.

PRESET
keep pressed
for preset lock
INPUT
PARALLEL
OUT
INPUT
(balanced)
GROUND
LIFT
ON LIMIT
LINK
LINK
(parallel)
POWER
ON
ATTENTION!:
READ MANUAL FOR
CORRECT
PRESET SELECTION
1+ POSITIVE OUT
1- NEGATIVE OUT
2+ N.C.
2- N.C.
REMOTE
DSP
POWER
OUTPUT
ANALOG
POWER SUPPLY
INPUT
PAD
dB
0
0.5 34
5
6
9
12
18
35
0
0
RS485
ADDRESS
MADE IN ITALY
WARNINGS:
To ensure correct operation,
allow at least
20 cm clearance from
back surface and correct
ventilation. To reduce risk of
electric shockdo not remove
cover. No operatoror serviceable
parts inside. Refer servicing to
qualified personnel. To reduce the
risk of fire or electric shock do
not expose this appliance to
rain or moisture.
CAUTION
RISK OF ELECTRICAL SHOCK
DO NOT OPEN!
DO NOT EXPOSE
TO RAIN OR MOISTURE!
ATTENTION
RISQUE DE CHOC ELECTRIQUE
NE PAS ENLEVER!
is a product of
viale Roma 7/i, 50037 S.Piero a Sieve
Firenze ITALY Tel + 39 055 8487222
HP Sound Equipment srl
ID12
PRESET
I
0
PUSH
Balanced XLR
In \ Out parallel
RS485 connection
for remote control
(don't connect to
LAN port!)
Ground lift switch
Input pad level
Preset change button
Keep it pressed 10sec.
to store preset as default
I D n u m b e r f o r
remote control
S p e a k o n p o w e r
output.
To use with KR100
satellite or with
K L 1 2 p a s s i v e
subwoofer
PowerCon Input
PowerCon parallel Output
(max 14 A)
Preset loaded
ENGLISH
USER'S MANUAL
REV.05 pag. 04
4. AMPLIFIER PANEL

Acoustics
Power handling
Max power
Impedance
Operating frequency range
Frequency range
SPL 1W/1mt
Maximum SPL
Cross over
Type
Frequency
Transducers
Low frequency
High frequency
Audio Input
Connectors
Wiring
Audio powered Output
Connector
Wiring
Remote control Input
Connectors
Power Input
Connectors
Amplifiers
Type
Subwoofer power
Satellite power output
Protections
AC power
Operating range
Max continuos and burst current
Physical
Measures
Weight
500(sub) + 250(sat) w1
1000(sub) + 600(sat) w
(sub) + 8 (sat)
40Hz - 19 KHz +/- 3dB (preset relating)
35Hz - 19 KHz +/- 3dB (preset relating)
98.5 dB(sub) 98 dB(sat)
124dB continuos - 130 dB peak
DSP controlled preset relating
150 Hz minimum (preset relating)
1 x 12" Neodymium speakers with 3" voice coil
16 x 2" Neodymium speakers with 0,75" voice coil
male + female parallel 3 poles balanced XLR
= ground / = hot / = cold
Female Speakon (16A max)
= CH1+ / = CH1- / = N.C. / = N.C.
1 x female 8 poles RJ45
2 x PowerCon IN/OUT (Max Out 14A)
1 modules class D - DSP controlled
750 Watt
750 Watt
Dynamic limiter, over current, over temp, short circuits
Standard 210 - 240 Vac 50Hz (standard)
Standard 6A(>10 sec) - 12A (<1 sec)
33.5 x 33.5 x 43.5 cm (KL12ma) 5.5 x 7 x 100 cm (KR100)
13 Kg (KL18ma) 4.5 Kg (KR200)
2
3
4
5
6
7
8
8
4W W
Pin1 Pin2 Pin3
Pin1+ Pin1- Pin2+ Pin2-
Optional 100 - 120 Vac 60Hz (optional)
Optional 10A(>10 sec) - 20A (<1sec)
Notes for data
1. Power handling is measured following AES standard conditions: transducers driven continuously for two hours with a band-limited noise signal having 6 dB of crest factor.
2. Max power is the maximum RMS applicable power for a musical signal, the referement signal is the one proposed by EIAJ standard.
3. Recommended maximum operating frequency range. Response depends on loading conditions and room acoustics.
4. Free field measured with 1/3 octave frequency resolution at 2 mt.
5. Measured@4 mt then scaled@1 mt.
6. Measured with audio source @1 mt.
7. This is the frequency in which the transducers produce the same sound pressure level (measured@2 mt).
8. Amplifier wattage rating is based on the maximum unclipped burst sine wave RMS voltage that the amplifier will produce into the nominal load impedance .
HP Sound Equipment s.r.l. - www.k-array.com
Viale Roma 7/i 50037 San Piero a Sieve (Firenze) Italy - tel +39 055 8487222 fax e-mail: info@k-array.com+39 055 8487238
ENGLISH
USER'S MANUAL
REV.05 pag. 05
5. TECHNICAL DATA

4.5 Kg
13 Kg
100 cm
33.5 cm
33.5 cm
43.5 cm
KR100
KL12ma
XLR Input
Speakon Output
Speakon Input
AC Input
AC Output
ENGLISH
USER'S MANUAL
REV.05 pag. 06
6. PHYSICAL

Clear
MCSB Music
Back Live
Dark
HP60 Li-3Cl-3
Li-6Cl-6
- Per caricare nuovi preset sul KL12ma è necessario
utilizzare l'adattatore USB-RS485 K-array K-usb.
- Per avere news riguardanti aggiornamenti di preset e
7. PRESETS
REV.05 pag. 07
MANUALE DELL'UTENTE ITALIANO

NOTES
www.k-array.com
by
HP Sound Equipment s.r.l.
Viale Roma 7/i
50037 San Piero a Sieve (Firenze)
Italy
tel +39 055 8487222 fax +39 055 8487238
e-mail: info@k-array.com
K
array
The contents of this manual are fornished for informational purpose
only. Hp Sound Equipment s.r.l. assumes no responsability for any
errors or inaccuracies that may appear in this manual.
Hp Sound Equipment s.r.l. reserves the right to make modifications
without prior notice.
Table of contents
Other K-array Speakers System manuals

K-array
K-array Python KP52 User manual

K-array
K-array Kobra KK52 User manual

K-array
K-array Concert Series Quick start guide

K-array
K-array Mugello-KH I User manual

K-array
K-array Vyper KV52 User manual

K-array
K-array Vyper KV50 User manual

K-array
K-array Redline KR100S User manual

K-array
K-array ninja kj50vb User manual

K-array
K-array Ko40 User manual

K-array
K-array Pinnacle-KR II User manual