Table of contents
1 User instructions ................................................................................................................ 4
1.1 User guide .................................................................................................................... 4
1.1.1 Abbreviations ..................................................................................................... 4
1.1.2 Symbols ............................................................................................................ 4
1.1.3 Target group ...................................................................................................... 4
2 Setup methods according to ISO 17664 ............................................................................ 5
2.1 instructions ................................................................................................................... 5
2.2 General instructions for the reprocessing of KaVo treatment units....................................... 6
2.2.1 Overview of ESTETICA E70 Vision / E80 Vision reprocessing.................................... 8
2.3 Reprocessing of the surfaces of treatment centre / upholstery............................................ 9
2.4 Preparation of the dentist unit......................................................................................... 11
2.4.1 Preparation of the handle and holder pad/ anti-slip mat .......................................... 11
2.4.2 Preparing the instrument holder ........................................................................... 12
2.4.3 Reprocessing of the swing-arm S table (E70 Vision only) ........................................ 13
2.4.4 Setting up the triple-function and multifunction handpiece ...................................... 14
2.4.5 Preparation of the instrument hoses ..................................................................... 17
2.4.6 Servicing the turbine return air filter ..................................................................... 17
2.4.7 Reprocessing of the kit for physiological saline solution and surgical motor ............... 18
2.4.8 Reprocessing KaVo ERGOcam One ....................................................................... 22
2.5 Preparation of the assistant unit ...................................................................................... 23
2.5.1 Preparing the instrument holder ........................................................................... 23
2.5.2 Preparing the connector for the suction hose ......................................................... 24
2.5.3 Reprocessing of sieve inserts and suction hoses ..................................................... 25
2.5.4 Preparation of the sleeve of the Aquamat device .................................................... 26
2.6 Reprocessing of the patient element (optional) ................................................................. 26
2.6.1 Preparation of the tumbler................................................................................... 27
2.6.2 Preparation of the tumbler holder and filler............................................................ 27
2.6.3 Preparation of the spittoon................................................................................... 28
2.7 Automatic cleaning programmes ..................................................................................... 29
2.7.1 Preparation of the cleaning programmes ............................................................... 29
2.7.2 Discontinuing a cleaning programme .................................................................... 32
2.7.3 Cleaning programme, "After treatment" ................................................................ 32
2.7.4 Cleaning programs "Morning" and "Evening".......................................................... 33
2.7.5 "Weekly" cleaning programme ............................................................................. 34
2.7.6 Manual internal cleaning of the suction hoses......................................................... 37
2.8 Reprocessing of the handpiece holder .............................................................................. 37
2.9 Preparation of the amalgam separator ............................................................................. 39
2.10Reprocessing KaVo Screen One / KaVo Screen HD ............................................................ 39
2.11Reprocessing of the service table 1568 ............................................................................ 40
3 Replacing and checking cleaning and germ reduction agents ...........................................41
3.1 Replace the DEKAPURE Gel cleaner.................................................................................. 41
3.2 Replace the OXYGENAL 6 cleaner .................................................................................... 42
3.3 Check the OXYGENAL 6 concentration.............................................................................. 43
Care instructions ESTETICA E70 Vision / E80 Vision
Table of contents
3 / 48