Keba Kemro NX 252/A Installation and operation manual

Kemro
NX 252/A
Ethernet PCI option module
Project engineering manual V1.03
Translation of the original instructions

Document : V1.03 / article no.: 1000412
Filename : nx252apjen.pdf
Pages : 21
.
© KEBA 2011
Specifications are subject to change due to further technical developments. Details presented may be subject to correction.
All rights reserved.
A: KEBA AG, Gewerbepark Urfahr, A-4041 Linz, Tel.: +43 732 7090-0, Fax: +43 732 7309-10, E-Mail: [email protected]
D: KEBA GmbH Automation, Leonhard-Weiss-Straße 40, D-73037 Göppingen, Tel.: +49 7161 9741-0, Fax:
US: KEBA Corp., 100 West Big Beaver Road, Troy, MI 48084, US, Tel.: +1 248 526-0561, Fax: +1 248 526-0562, E-Mail:
CN: Beijing Austrian KEBA Science and Technology Development Ltd., Room B516, Nan Xin Cang Tower, A22 Dong Si Shi
Tiao, Dong Cheng District, Beijing, 100027, P.R. China, Tel. +86 10 6409-6592, Fax +86 10 6409-6312, E-Mail:
www.keba.com

Record of Revision
Version Date Change in chapter Description changed by
1.00 02-2008 Newly created meis
1.01 04-2009 EC directives corrected hasl
1.02 08-2010 EC directives and
standards, Declara-
tion of conformity
updated hasl
1.03 08-2011 Introduction Hint "not for end customers" added, various minor up-
dates. fstl
NX 252/A Record of Revision
© KEBA 2011
Project engineering manual V1.03 3


Table of Contents
1 Introduction....................................................................................................................... 7
1.1 Purpose of the document........................................................................................ 7
1.2 Preconditions.......................................................................................................... 7
1.3 Intended use........................................................................................................... 8
1.4 Notes on this document.......................................................................................... 8
1.4.1 Contents of the document........................................................................ 8
1.5 Documentation for further reading.......................................................................... 8
2 Safety notes...................................................................................................................... 9
2.1 Representation........................................................................................................ 9
2.2 General safety instructions...................................................................................... 9
3 Description of the module............................................................................................. 11
3.1 Front view.............................................................................................................. 11
4 Installation instructions................................................................................................. 12
5 Connections and wiring................................................................................................. 15
5.1 Ethernet................................................................................................................. 15
5.1.1 Pin assignment....................................................................................... 15
5.1.2 Cable and plug specification.................................................................. 15
5.2 EMC and wiring guidelines.................................................................................... 15
6 Configuration.................................................................................................................. 16
7 Operating behavior......................................................................................................... 17
7.1 Start-up after Power-On........................................................................................ 17
7.2 Reset..................................................................................................................... 17
8 Disposal........................................................................................................................... 18
8.1 Disposal of the module.......................................................................................... 18
9 Technical data................................................................................................................. 19
9.1 Environmental conditions...................................................................................... 19
9.2 Interface to the CPU module................................................................................. 19
9.3 Ethernet interface.................................................................................................. 19
9.4 Mechanics............................................................................................................. 19
10 EC directives and standards......................................................................................... 20
10.1 EC directives......................................................................................................... 20
10.2 Standards.............................................................................................................. 20
10.2.1 General procedures and safety principles.............................................. 20
10.2.2 EMC guideline........................................................................................ 20
10.2.3 Electrical safety and fire protection........................................................ 20
10.2.4 Environmental and surrounding conditions............................................ 20
10.3 Standards for the American market...................................................................... 20
10.3.1 UL test for industrial control equipment.................................................. 20
NX 252/A Table of Contents
© KEBA 2011
Project engineering manual V1.03 5

1 Introduction
1.1 Purpose of the document
This document describes the structure of the NX 252/A
(Ethernet PCI option module).
Information
This manual is not adressed to end costumers! Necessary safety notes for
theendcostumerhavetobetakenintothecostumermanualintherespective
national language by the machine builders and system providers.
1.2 Preconditions
This document contains information for persons with the following skills:
Target group Knowledge and skills pre-requirement
Project engineer
Basic technical training (University of Applied Science/University level,
engineering degree or corresponding professional experience).
Knowledge in:
●working mode of a PLC,
●safety regulations,
●the application.
Operator
Basic technical training (Vocational high school, engineering degree or
corresponding professional experience).
Knowledge in:
●safety regulations,
●working mode of machine or plant,
●principal functions of the application,
●system analysis and troubleshooting,
●setting options at the operating installations.
Service technician
Basic technical training (Vocational high school, engineering degree or
corresponding professional experience).
Knowledge in:
●working mode of a PLC,
●safety regulations,
●working mode of machine or plant,
●diagnosis possibilities,
●systematic error analysis and rectification.
NX 252/A Introduction
© KEBA 2011
Project engineering manual V1.03 7

1.3 Intended use
The NX 252/A may only be used for the types of use described in the technical
descriptions and only in conjunction with recommended/approved third-party
equipment/installations.
The NX 252/A has been developed, manufactured, tested and documented in
accordance with the appropriate safety standards. Therefore, the products do
not pose any danger to the health of persons or a risk of damage to other
property or equipment under normal circumstances, provided that the instruc-
tionsandsafetyprecautionsrelatingtotheintendeduseareproperlyobserved.
1.4 Notes on this document
This manual is integral part of the product. It is to be retained over the entire
life cycle of the product and should be forwarded to any subsequent owners
or users of the product.
1.4.1 Contents of the document
●Description of the Ethernet PCI option module NX 252/A
●Use of the Ethernet PCI option module in CPU modules
●Description of interface including EMC measures
●Technical data
1.5 Documentation for further reading
Thefollowingdocumentsaretobeobserveddependingonthesystemsolution
used:
If you are using the KeStudio U2 tool suite:
Doc.No. Name Target group
DE: 65352
EN: 65353 K2-200 automation system manual
●Project engineer
●Electrician
●Programmer
●Commissioning foreman
●Service technician
If you are using the KeStudio U3 tool suite:
Doc.No. Name Target group
DE: 1000868
EN: 1000869 System manual Kemro automation
system
●Project engineer
●Electrician
●Programmer
●Commissioning foreman
●Service technician
Introduction NX 252/A
© KEBA 2011
Project engineering manual V1.038

2 Safety notes
2.1 Representation
At various points in this manual you will see notes and precautionary warnings
regarding possible hazards. The symbols used have the following meaning:
DANGER!
●indicates an imminently hazardous situation which will result in death or
serious bodily injury if the corresponding precautions are not taken.
WARNING!
●indicates a potentially hazardous situation which can result in death or se-
rious bodily injury if the corresponding precautions are not taken.
CAUTION!
●meansthat ifthe corresponding safetymeasures arenottaken, apotentially
hazardous situation can occur that may result in property injury or slight
bodily injury.
CAUTION
●CAUTION used without the safety alert symbol indicates a potentially haz-
ardous situation which, if not avoided, may result in damage to property.
●This symbol reminds you of the possible consequences of touching elec-
trostatically sensitive components.
Information
Useful practical tips and information on the use of equipment are identified
by the “Information” symbol. They do not contain any information that warns
about potentially dangerous or harmful functions.
2.2 General safety instructions
WARNING!
●It is absolutely essential to observe the safety instructions in the system
manual.
●The module is defined as "open type equipment" (UL508) or as "offenes
Betriebsmittel" (EN 61131-2) and must therefore be installed in a control
cabinet.
NX 252/A Safety notes
© KEBA 2011
Project engineering manual V1.03 9

CAUTION
Improper use of the assembly or the control system leads to irreparable dam-
age!
●Turn off the power supply before inserting or removing the module. Other-
wise, the module can be destroyed or undefined signal states can lead to
damage of the control system.
When removed from it's casing this module is sensitive to electrostatic dis-
charge. Before handling the modules touch a grounded metal object in order to
discharge any static electricity from your body.
Safety notes NX 252/A
© KEBA 2011
Project engineering manual V1.0310

3 Description of the module
The NX 252/A is a Ethernet PCI option module for inserting into CPU modules
of the type CP 24x/x or CP 25x/x. The NX 252/A Ethernet PCI option module
can be integrated into a 10Mbit/s as well as a 100Mbit/s Ethernet.
Information
The module’s functionality is only guaranteed if used within a
CP 24x/x or CP 25x/x. The module is not designed for connection with foreign
modules.
3.1 Front view
Fig.3-1: NX 252/A front view
NX 252/A Description of the module
© KEBA 2011
Project engineering manual V1.03 11

4 Installation instructions
The module has been designed for operation with CPU-module, where it is
inserted into the PCI slot.
Fig.4-1: Use of a NX 252/A in a CPU module
Information
The Ethernet PCI option module may not be plugged or removed if the CPU
module is activated.
Inserting an option module into slot
1) Turn off power supply
2) Remove dummy module
3) Insertmoduleinthecorrectposition(labellingrightside)intotheright-hand
slot
Installation instructions NX 252/A
© KEBA 2011
Project engineering manual V1.0312

Fig.4-2: Inserting the NX 252/A
Removing an option module:
1) Turn off power supply
2) Pull module out of the slot
3) Insert dummy module
NX 252/A Installation instructions
© KEBA 2011
Project engineering manual V1.03 13

Fig.4-3: Removing the NX 252/A
Installation instructions NX 252/A
© KEBA 2011
Project engineering manual V1.0314

5 Connections and wiring
5.1 Ethernet
5.1.1 Pin assignment
Fig.5-1: Ethernet connection
Pin no. Signal designation Input / Output
1 Tr. Data + Transmit Data + Output
2 Tr. Data - Transmit Data - Output
3 Re. Data + Receive Data + Input
4 Bi-Data + n.c. ---
5 Bi-Data - n.c. ---
6 Re-Data- Receive Data - Input
7 Bi-Data + n.c. ---
8 Bi-Data - n.c. ---
5.1.2 Cable and plug specification
Further information: See system manual.
5.2 EMC and wiring guidelines
Pay attention from the outset to careful wiring and shielding.
Further information: See system manual.
NX 252/A Connections and wiring
© KEBA 2011
Project engineering manual V1.03 15

6 Configuration
No configuration is required for this module.
Configuration NX 252/A
© KEBA 2011
Project engineering manual V1.0316

7 Operating behavior
7.1 Start-up after Power-On
The module is passive and is configured and activated through the HOST.
7.2 Reset
The module can be reset by the HOST without the HOST itself having to be
reset.
NX 252/A Operating behavior
© KEBA 2011
Project engineering manual V1.03 17

8 Disposal
8.1 Disposal of the module
CAUTION
Please observe the regulations regarding disposal of electric appliances and
electronic devices!
●The symbol with the crossed-out waste container means that electrical
and electronic devices including their accessories must not be disposed
of in the household garbage.
●The materials are recyclable in accordance with their labeling. You can
makeanimportantcontributiontoprotecting ourenvironmentbyreusing,
renewing and recycling materials and old appliances.
Disposal NX 252/A
© KEBA 2011
Project engineering manual V1.0318

9 Technical data
9.1 Environmental conditions
Operating temperature: +5 °C to +55 °C
Storage temperature: -40 °C to 70 °C
Relative humidity of air: 10 % to 95 % (non condensing)
Vibration resistance: according to EN 61131-2:2007
Shock resistance: according to EN 61131-2:2007
9.2 Interface to the CPU module
Interface type: Media Independent Interface
Connection: CHAMP plug 30-pin
Power supply: 5 V
Power consumption (5 VDC): 2 W
Module recognition: YES (Module given, YES/NO, no type recog-
nized)
9.3 Ethernet interface
Ethernet interface: 10/100 MBit/s LAN,
Galvanic isolation: Yes, signaling line
Number: 1
Connection: Modular 8-pin plug (RJ45 plug)
9.4 Mechanics
Structure: No casing; only front plate mounted on print
Protection class: When the module is plugged into CPU module,
then the CPU module conforms to IP 20
Weight: 23 g
NX 252/A Technical data
© KEBA 2011
Project engineering manual V1.03 19

10 EC directives and standards
10.1 EC directives
Guideline 2004/108/EC EC guideline on electromagnetic compatibility
Guideline 2002/95/EC RoHS guideline
10.2 Standards
To check the conformity of the system with the directives, the following non-
binding legal European standards were applied:
10.2.1 General procedures and safety principles
EN 61131-1:2003 Programmable controllers - Part 1
Information
This product was developed for the use in industrial areas and can cause
radio interference when used in residential areas.
10.2.2 EMC guideline
EN 61131-2:2007 Programmable controllers - Part 2
10.2.3 Electrical safety and fire protection
EN 61131-2:2007 Programmable controllers - Part 2
10.2.4 Environmental and surrounding conditions
EN 61131-2:2007 Programmable controllers - Part 2
10.3 Standards for the American market
10.3.1 UL test for industrial control equipment
UL 508, 2005 Industrial Control Equipment
EC directives and standards NX 252/A
© KEBA 2011
Project engineering manual V1.0320
Table of contents
Other Keba Control Unit manuals

Keba
Keba Kemro K2 Installation and operation manual

Keba
Keba Kemro FM 280/A Installation and operation manual

Keba
Keba Kemro CP 263/S Installation and operation manual

Keba
Keba Kemro MM 240/A Installation and operation manual

Keba
Keba Kemro TM 225/A Installation and operation manual

Keba
Keba D3-DA 3 Series Installation and operation manual

Keba
Keba D3DP 3 Series Installation and operation manual

Keba
Keba Kemro FX 271/A Installation and operation manual

Keba
Keba Kemro MM 280/A Installation and operation manual

Keba
Keba D3-DA 3 Series Installation and operation manual