Kenner KNL100E-01 User manual

VER 1
9
b

Table of Contents
Safety Installation Information .......................................................................................................................... 1
Parts List ........................................................................................................................................................... 3
Optional Accessories Parts List........................................................................................................................ 4
Tools Needed: .................................................................................................................................................. 4
Technical Specifications & Features ................................................................................................................ 5
Installation Overview ........................................................................................................................................ 6
Preparation for Installation ............................................................................................................................... 7
Install the Gate Opener on the Gate ................................................................................................................ 7
Mounting of the control box .............................................................................................................................11
Connection of the Power Supply .....................................................................................................................11
Connection of the control board ..................................................................................................................... 14
How to Program the Remote to the Opener .................................................................................................. 17
How to Erase All the Remote Codes .............................................................................................................. 18
How to use the remote to operate your gate opener ..................................................................................... 18
Wireless keypad programming....................................................................................................................... 18
Adjusting the Limit Switch .............................................................................................................................. 19
Setting of the Control Board ........................................................................................................................... 19
Trouble Shooting ............................................................................................................................................ 20

1
Safety Installation Information
1. READ and FOLLOW all instruction.
2. The gate opener is intended for use with Class I
vehicular swing gates.
Class I denotes a vehicular gate opener (or system)
dwellings, a garage or parking area associated with.
Install the gate opener only when the opener is
appropriate for the construction and the usage class of
the gate.
3. Gate opening system designers, installers and
users must take into account the possible hazards
associated with each individual application. Improperly
designed, installed or maintained systems can create
risks for the user as well as the bystander. Gate
system design and installation must reduce public
exposure to potential hazards. All exposed pinch
points must be eliminated or guarded.
4. A gate opener can create high levels of force
during normal operation. Therefore, safety features
must be incorporated into every installation. Specific
safety features include safety sensors.
5. The gate must be properly installed and work
freely in both directions prior to the installation of the
gate opener.
6. The gate must be installed in a location so that
enough clearance is provided between the gate and
adjacent structure when opening and closing to
reduce the risk of entrapment. Swinging gates shall
not open into public access areas.
7. The opener is intended for use only on gates used
for vehicles. Pedestrians must be supplied with a
separate access opening. The pedestrian access
opening shall be designed to promote pedestrian
usage. The pedestrian access shall be located
where person(s) will not come in contact with the
moving vehicular gate.
8. Pedestrians should never cross the pathway of a
moving gate. The gate opener is not adequate for
pedestrian use. Pedestrians must be supplied with
a separate pedestrian access.
9. For an installation utilizing non-contact sensors
(safety sensors), see product manual on the
placement of non-contact sensors (safety sensors) for
each type of application.
a. Care shall be exercised to reduce the risk of
nuisance tripping, such as when a vehicle trips the
safety sensor while the gate is still moving.
b. One or more non-contact sensors (safety sensors)
shall be located where the risk of entrapment of
obstruction exists, such as the perimeter reachable by
a moving gate or barrier.
10. Never mount any device that operates the gate
opener where the user can reach over, under, around
or through the gate to operate the controls. Controls
are to be placed at least 6’ (1.8m) from any part of the
moving gate.
11. Controls intended to be used to reset an operator
after 2 sequential activations of the entrapment
protection device or devices must be located in the
line of sight of the gate, or the controls that have
easy access shall have a security feature to
prevent unauthorized use. Never allow anyone to
hang on or ride the gate during the entire travel of
the gate.
12. Each gate opener is provided with two safety
warning placards. The placards are to be installed on
the front and back of the gate where they are fully
visible. The placards may be mounted using cable ties
through the four holes provided on each placard.
All warning signs and placards must be installed
where visible from the gate area.

2
13. To AVOID damaging gas, power, or other
underground utility lines, contact underground utility
locating companies BEFORE digging.
SAVE INSTRUCTION.
14. Do not permit children to play on or around the
gate and keep all controls out of their reach.

3
Parts List



6
Installation Overview

7
Preparation for Installation
There are two installation types for the gate opener, Pull-to-Open and Push-to-Open.
Our gate opener is designed for Pull-to-Open, in the Push-to-Open installation, please purchase
Push-To-Open Bracket from your supplier.
The gate opener is mounted to the gate
and to the gate post. Both round and
square posts can be used because the
Post Brackets are curved. When
mounting the Post Brackets, use bolts
long enough to pass through the entire
post. M10 x 200 bolts are included.
Concrete anchors are not provided.
When mounting the Post Brackets to
wooden posts, a larger-size washer or
metal plate should be used between the
bolts and the wooden post to ensure the stability of the fastening hardware. If the post is smaller than 6"
diameter or square, it should be made of metal and set in cement to ensure its stability.
Install the Gate Opener on the Gate
The position of Post Bracket is very important. The following illustrations and tables are required to determine
the proper mounting position for the Post Bracket. The tables show the maximum opening angle of the gate for
a given A and B. For example, if A is 15 cm and B is 20 cm, the maximum opening angle of the gate is 110°.
Pull-to-Open Installation — Gate in Closed position (Moving-Rod is extended)
NOTE: Ensure the gate does not open into public areas.


9
5. Make sure there is a minimum clearance of 2.5cm between the gate and the opener and that the opener and
the Post Pivot Bracket are not binding in both the gate-open and gate-closed positions. If there is not at least
2.5cm of clearance or if the opener and the Post Pivot Bracket are binding, rotate the Post Pivot Bracket and/or
move the Post Bracket Assembly to obtain the minimum clearance and eliminate the binding. When the
minimum clearance has been obtained and any binding has been eliminated, place the M8 x 30 bolt through the
aligned holes in the Post Bracket and the Post Pivot Bracket.


12.
Open the release hole plug on the top of the gate opener, insert the release key, and turn the key 90°
counterclockwise. This restores normal operation.
Mounting of the
control box
Remove the cover of the control box and use 4 deck
(
not provided) to install the control box.
box is installed in a secure surface and at least 100 cm (40
inches) above the ground to protect it from rain, snow, etc.
wh
ich probably cause damage to the control box.
Connection of the P
ower
The gate opener can be powered by 24V 12Ah battery (NOT INCLUDED) OR
supply (NOT INCLUDED) with minimum output power 150W.
ONLY used to charge the battery.
Instead of using a battery, the AC
save the cost where AC electricity is accessible
and stable.
If batteries
are chosen as the power source,
Marine or Automotive Type Battery with
capacity greater than 7
Ah is required. The
batteries should be waterproof type, or be
placed in water proof circumstance.
2 PCS 12VDC batteries can be connected in
series to function
as 24VDC. The following
diagram shows on how to connect 2 PCS
batteries in series. Charging mode for the
battery could be by the adapter, by the solar panel, or both of them at the same time.
11
Open the release hole plug on the top of the gate opener, insert the release key, and turn the key 90°
counterclockwise. This restores normal operation.
control box
Remove the cover of the control box and use 4 deck
screws
not provided) to install the control box.
Ensure the control
box is installed in a secure surface and at least 100 cm (40
inches) above the ground to protect it from rain, snow, etc.
ich probably cause damage to the control box.
Supply
The gate opener can be powered by 24V 12Ah battery (NOT INCLUDED) OR
supply (NOT INCLUDED) with minimum output power 150W.
The adapter included in the packag
Instead of using a battery, the AC
-
DC Power Supply is highly recommended as the power source to
save the cost where AC electricity is accessible
are chosen as the power source,
Marine or Automotive Type Battery with
Ah is required. The
batteries should be waterproof type, or be
placed in water proof circumstance.
2 PCS 12VDC batteries can be connected in
as 24VDC. The following
diagram shows on how to connect 2 PCS
batteries in series. Charging mode for the
battery could be by the adapter, by the solar panel, or both of them at the same time.
Open the release hole plug on the top of the gate opener, insert the release key, and turn the key 90°
The gate opener can be powered by 24V 12Ah battery (NOT INCLUDED) OR
a 24VDC AC-DC power
The adapter included in the packag
e is
DC Power Supply is highly recommended as the power source to
battery could be by the adapter, by the solar panel, or both of them at the same time.

Please note that the wire connection of the power supply syste
connection will damage the control board.
WARNING: NEVER connect the gate opener to the power outlet before all the installations have been
done.
1. Use the batteries
as the power source
the batteries
The “ 24V+”
of the battery should be wired to the
terminal. The wire (2*0.75mm2,
1meter
connected to the control board in factory.
terminals of the control board, no matter the polarity.
distance between the outlet and the control box is longer than that, you should use an extended wire to connect
the adapter to the control board. The wire size should be at least 16
(300’), the wire si
ze should be at least 14
300m (1000’).
You can plug the adapter
into the electrical o
connections are completed
. Use a surge protector
strongly recommended.
If electrical outlet is
adapter should be protected by a
weatherproof cover.
2. Use the batteries
as the power source
adapter & solar panel to charge the batteries at the
same time
If you want to use an optional
solar panel
charge controller must be used to control it to charge the battery. You can connect adapter, the solar panel and
the solar charge controller refers
to the following il
12
Please note that the wire connection of the power supply syste
m is very important. Incorrect wire
connection will damage the control board.
WARNING: NEVER connect the gate opener to the power outlet before all the installations have been
as the power source
and only use the adapter to char
of the battery should be wired to the
BAT+ (#11) terminal, “ 24V-”
should be wired to
1meter
long) for connecting the battery has been provided and
connected to the control board in factory.
The adapter
should be wired to the
terminals of the control board, no matter the polarity.
The length of the wire of the adapter is
distance between the outlet and the control box is longer than that, you should use an extended wire to connect
the adapter to the control board. The wire size should be at least 16
AWG
. If the distance is more than
ze should be at least 14
AWG
. The maximum distance from the adapter to the control box is
into the electrical o
utlet after all the wire
. Use a surge protector
with the adapter is
If electrical outlet is
located outdoors, outlet and
weatherproof cover.
as the power source
and use the
adapter & solar panel to charge the batteries at the
solar panel
to charge the battery
with the adapter at the same time
charge controller must be used to control it to charge the battery. You can connect adapter, the solar panel and
to the following il
lustration.
m is very important. Incorrect wire
WARNING: NEVER connect the gate opener to the power outlet before all the installations have been
and only use the adapter to char
ge
should be wired to
“ BAT-” (#12)
long) for connecting the battery has been provided and
“ ADAPTER” (#13, #14)
The length of the wire of the adapter is
1.2m (4’). So if the
distance between the outlet and the control box is longer than that, you should use an extended wire to connect
. If the distance is more than
100m
. The maximum distance from the adapter to the control box is
with the adapter at the same time
, a solar
charge controller must be used to control it to charge the battery. You can connect adapter, the solar panel and

13
3. Use the batteries as the power source and only use the solar panel to
charge the batteries
If you only use the solar panel to charge the batteries, please note the power of the solar panel should be at
least 20W. The gate opener can works for 10 cycles per day if there is no other accessory except
photocell & electric lock & push button& alarm lamp connected to the control board. The capacity of the
batteries and the power of the solar panel should be enlarged if you want to use more. You can connect the
solar panel and the solar charge controller refers to the following illustration.
4. Use the 24VDC AC-DC power supply as the power source if AC electricity is accessible and stable
The gate opener can be powered by an AC to DC 24V Power Supply (NOT INCLUDED). Instead of using

14
batteries, this alternative save costs and is strongly recommended. The positive output of the 24VDC power
supply should be wired to the BAT+ (#11) terminal, the negative output should be wired to “BAT-” (#12) terminal.
There is no need to use the adapter in this situation.
Connection of the control board

15
1. Actuator
Insert the stripped cable wires into the appropriate terminals on the opener terminals block. The red wire should
be inserted into the “ +MOTOR” terminal(#17), the black wire into “ MOTOR-” terminal (#18), the blue wire into
“ DLMT” terminal(#19), the green wire into “ COM” terminal(#20), and the yellow wire into “ ULMT” terminal
(#21).
2. Battery (Required but not included)
The “ 24V+” of the battery should be wired to the +BAT (#11) terminal, “ 24V-” should be wired to “ BAT-” (#12)
terminal. 2*12VDC batteries can be connected in series to become 24V.
3. AC transformer (Only used to charge the batteries)
Insert the stripped cable wires into AC24V (#13) terminals to the control board. No matter the polarity.

16
4. Alarm Lamp (optional)
The red wire of the alarm lamp should be inserted into either LAMP (#15) terminal, the white wire into the other
one (#16).
5-1. Photocell Beam System (PBS) (optional)
Use a 2-core cable to connect the “ + ~” terminal of the photocell emitter to the “+24” (#1) terminal, the “ - ~”
terminal to the “GND” (#3) terminal. Also the “ + ~” and “ - ~” terminals of the photocell receiver should be
connected to the “+24” and “GND” terminals in parallel.
Use another 2-core cable to connect the “ NC” terminal of the receiver to the “PHOTO”(#2) terminal, the “ COM”
terminal to the“GND”(#3) terminal.
5-2. KNL104B Reflective Photocell (optional)
Use a 2-core cable to connect the “ #2” terminal of the KNL104B photocell to the “ +24” (#1) terminal of gate
opener control board, the “ #3" terminal of the KNL104B photocell to the “ GND” (#3) terminal of gate opener
control board.
Use another 2-core cable to connect the “ NC” (#5) terminal of the KNL104B photocell to the “ PHOTO” (#2)
terminal of the gate opener control board, the “ COM” (#6) terminal of KNL104B photocell to the “ GND” (#3)
terminal of gate opener control board.
6. Push Button (optional)
The push button should be wired to the “#4 and “#5” terminals. No matter the polarity. The gate operator works
alternately by pressing the button (open-stop-close-stop-open).
7. Electric Lock (optional)
A lock plus board (should be purchased separately) is required to connect the electric lock to the control board.
The 2 wires of J1 of lock plus should be wired to the “9#” and “10#” terminal of the control board. No matter the
polarity. Red wire of J2 should be wired to the 11# terminal and yellow wire of J2 should be wired to the 12#
terminal. Red wire of J3 should be connected to the red wire of electric lock and also the yellow wire of J3
should be connected to the yellow wire of electric lock.
8. Exit Wand (optional)
The BLACK wire of the exit wand should be connected into the “#5” terminal.
The BLUE wire of the exit wand should be connected into the “#6” terminal.
The RED wire of the exit wand should be connected into the “#11” terminal.
The GREEN wire of the exit wand should be connected into the “#12” terminal.
The sensitivity adjustment board should be wired to the GREEN wire and the YELLOW wire of the wand. No
matter the polarity.
9. Wireless Exit Wand (optional)
The “ NO” terminal of the receiver should be wired to the “#5” terminal of the control board.
The “ COM” terminal of the receiver should be wired to the “#6” terminal of the control board.
The “ PWR” terminal of the receiver should be wired to the “#11” terminal of the control board.
The “ GND” terminal of the receiver should be wired to the “#12” terminal of the control board.

17
10. Wired Keypad (optional)
The RED wire of the wired keypad should be connected into the “#11” terminal.
The BLACK wire of the wired keypad should be connected into the “#5” terminal.
The PURPLE wire of the wired keypad should be connected into the “#5” terminal.
The BLUE wire of the wired keypad should be connected into the “#4” terminal.
11. External receiver (optional)
The RED wire of the external receiver should be connected into the “#11” terminal.
The BLACK wire of the external receiver should be connected into the “#5” terminal.
The BROWN wire of the external receiver should be connected into the “#4” terminal.
Note: Using of the exit wand, keypad and external receiver would cause the battery exhausted quickly.
Big capacity of battery and big power of solar panel (if the solar panel is used as main charger) is
required if you want to use either of them.
How to Program the Remote to the Opener
You must program the remote to the opener before operating. You can follow the below steps to program the
remote to the opener.
Press and release the CODE SW button, the CODE LED will be ON, then press the key in the remote twice in 4
seconds, the CODE LED will flash for 3 seconds and then to OFF. Now the remote has been programmed
successfully.
NOTE: The button of the remote control should be pressed and hold for more than 2 seconds while
programming. Max. 10 remotes can be programmed for the opener. If you want program more remotes, you
should use an optional external receiver.

18
How to Erase All the Remote Codes
Press and hold the CODE SW button until the CODE LED from ON to OFF. Now all remote codes have been
erased.
How to use the remote to operate your gate opener
Each remote has four buttons, they are A, B, C and D.
You may use this remote to operate as many as 4 sets our swing gate opener or 1
set our sliding gate opener and 2 sets our swing gate opener.
1. Use this remote to only operate swing gate opener
A, B, C and D four buttons share same function once they are programmed with
our swing gate opener. You may choose any button to program it with our swing
gate opener. Every press of the button is able to active the gate opener to work
alternately (open-stop-close-stop-open).
2. Use one remote to operate swing gate opener & sliding gate opener at the same time
All of our sliding gate opener have midway mode. B is designed for a midway function (refer to more details in
sliding gate opener manual). In this case, program A button for sliding gate opener and program either C or D
button for swing gate opener.
Wireless keypad programming
You can follow the below steps to program wireless keypad to the opener. Press the CODE SW button until the
CODE LED is ON, and then release the button. Then press "OK" button on keypad and CODE LED will flash for
3 seconds and then be OFF which indicates the keypad has been programmed successfully. You can use the
default password “888888” to operate the opener after programming. You can press “PIN” “8 8 8 8 8 8” and then
press “OK” to confirm to operate the opener.
Also you can change the password of the keypad follow the below steps. Press “PIN” and then input the six
digits old password and then press ”PIN” again, the CODE LED will be ON. Input the six digits new password
and then press the “PIN” to confirm the new setting, CODE LED will flash for 3 seconds and then be OFF which
indicates the password has been changed successfully. You can press “PIN” “6 digits new password” and then
press “OK” to confirm to operate the opener.
NOTE: Every step for pressing button during program must be finished within 1 second to ensure successful
This manual suits for next models
1
Table of contents
Other Kenner Gate Opener manuals
Popular Gate Opener manuals by other brands

Meccanica Fadini
Meccanica Fadini Nyota 115 evo instruction manual

Dea
Dea 202 E Instructions and warnings

BFT
BFT SUB BT installation manual

Max
Max Phantom 2000 Installation and owner's manual

Aprimatic
Aprimatic SLIDE 230 Electrical installation, Use and Maintenance instructions

CAME
CAME ATS-S324 Quick setup guide