
9 - FORM NO. 56041434 - SelectSpot™
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
WARNING !
To reduce the risk electric shock or injury, unplug the power cord before servicing.
1Toggle the Power Switch (15) to the MIDDLE position to turn both the vacuum motor and the solution pump OFF.
2DISCONNECT THE POWER CORD (13).
3Move the machine to a designated waste water “DISPOSAL SITE”.
4Disconnect the Hose Assembly (6) from the machine.
5Unstrap the Latches (2) and lift the Recovery Tank (4) from the machine.
6Remove the Recovery Tank Lid (3), empty the tank and rinse with clean water.
7Tip the Solution Tank (1) over to empty unused water or solution. Rinse the tank thoroughly if any cleaning chemical was used.
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
MAINTENANCE SCHEDULE
MAINTENANCE ITEM DAILY WEEKLY YEARLY
Clean the Hand Tool X
Check the Power Cord for Damage X
**Flush Pump System X
Clean the Vacuum Motor Filters X
*Check the Vacuum Motor Brushes X
*Have Kent check the carbon motor brushes once a year or after 500 operating hours.
**If you use cleaning chemicals in the Solution Tank (1) the pump system should be flushed clean after each use.
8Store the machine indoors in a clean, dry place. Keep from freezing. Leave the tanks open to air them out..
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
FLUSHING PUMP SYSTEM
1Move the machine to a designated waste water “DISPOSAL SITE”.
2Fill the Solution Tank (1) with clean hot water.
3Plug the machine in and toggle the Power Switch (15) to the UP position.
4Pull and hold the trigger on the Hand Tool (7) until all of the water has emptied from the tank.
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
VACUUM MOTOR MAINTENANCE
Once a month, check the vacuum motor to make sure the airways are not blocked. Clear hose of debris and keep the vacuum motor exhaust area
clean.
Have Kent check the carbon motor brushes once a year or after 500 operating hours. Replace the carbon brushes if they are worn to 3/8” (9.5 mm)
or less.
IMPORTANT !
Motor damage from failure to service the carbon brushes is not covered under warranty.
AFTER USE
revised 2/01