KERR elements IC User manual

elements™IC
INSTRUCTIONS FOR USE
O B T U R A T I O N S Y S T E M
077-0901_REVA_ELEMENTS_IC_EU_IFU_BOOK_P24.indb Cover 6/13/19 6:21 PM

077-0901_REVA_ELEMENTS_IC_EU_IFU_BOOK_P24.indb 6/13/19 6:21 PM

TABLE OF CONTENTS
English................................................................................................................................................................................................. 2
Français...............................................................................................................................................................................................10
Español...............................................................................................................................................................................................16
Deutsch.............................................................................................................................................................................................. 22
Italiano............................................................................................................................................................................................... 28
Dansk................................................................................................................................................................................................. 34
Svenska..............................................................................................................................................................................................40
Ελληνικa ...........................................................................................................................................................................................46
Nederlands.........................................................................................................................................................................................52
Norsk.................................................................................................................................................................................................. 58
Suomi.................................................................................................................................................................................................64
Português.......................................................................................................................................................................................... 70
Polski...................................................................................................................................................................................................76
Românâ............................................................................................................................................................................................. 82
Magyar............................................................................................................................................................................................... 88
Slovenský...........................................................................................................................................................................................94
Český.................................................................................................................................................................................................100
Türkçe................................................................................................................................................................................................106
Eesti....................................................................................................................................................................................................112
Lietuvių..............................................................................................................................................................................................118
Slovensko .........................................................................................................................................................................................124
ةيبرعلا.............................................................................................................................................................................................130
Български.......................................................................................................................................................................................136
Hrvatski.............................................................................................................................................................................................142
Srpski................................................................................................................................................................................................148
......................................................................................................................................................................................154
077-0901_REVA_ELEMENTS_IC_EU_IFU_BOOK_P24.indb 1 6/13/19 6:21 PM

2
elements™IC
OBTURATION SYSTEM
The cordless elements™ IC obturation system combines a Downpack heat source with a Backfill extruder. The Downpack device provides fast heating of
the heat plugger with precisely controlled temperature and timing, making it suitable for single-motion downpack obturation of the apical portion of the
root canal. Utilizing single-use gutta-percha cartridges, the ergonomic Backfill device has a motorized extruder system for precise temperature and speed
control for a 3-dimensional obturation of the root canal system.
CONTENTS OVERVIEW
Backfill Device
Downpack Device
Ring Switch
Ring Switch
Battery Level Indicator
Mode Selection
Mode Button
On/O Power Button
On/O Power Button
Charging IndicatorCharging Indicator
Reverse Button
Battery Level Indicator
Power Cord
Dual Charging Base
Supplied only with combo unit
Heat Plugger
Supplied only with Downpack and combo unit
Transformer
Needle Bender
Supplied only with Backfill and combo unit
Single Charging Base
LED “ready-to-use” Indicator
Mode Selection
Gutta-Percha (GP) Level Indicator
Mode Button
077-0901_REVA_ELEMENTS_IC_EU_IFU_BOOK_P24.indb 2 6/13/19 6:21 PM

3
INDICATIONS FOR USE
The cordless elements™ IC obturation system is intended to be used in Endodontics
to backfill and downpack gutta-percha during root canal obturation using warm
vertical obturation technique.
CONTRAINDICATIONS
• Not for use in the presence of flammable anesthetics such as a mixture of
oxygen, air and nitrous oxide.
• The obturation unit should NOT be used on a patient with a pacemaker.
• Do not use on patients with a known sensitivity to natural rubber latex or
copper.
WARNINGS
Read the following warning before using this device.
• This device has been investigated with regards to safety from electrical shock
and fire hazard as well as electromagnetic compatibility (EMC). The device has
not been investigated for other physiological eects.
Please contact Kerr Endodontics if you have any further questions regarding
electrical safety or EMC.
• This device has been tested and found to comply with EMC limits for the
Medical Device Directive 93/42/EEC. These limits are designed to provide
reasonable protection against harmful interference in a typical medical
installation. The device generates radio frequency energy and, if not
installed and used in accordance with these instructions, may cause harmful
interference to other devices in the vicinity.
However, there is no guarantee that interference will not occur in a particular
installation. If this device does cause harmful interference with other devices,
which can be determined by turning the device o and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
— Reorient or relocate the receiving device.
— Increase the separation between devices.
— Connect the device into an outlet on a circuit dierent from that to
which the other device(s) is connected.
— Consult the manufacturer for help.
WARNING: This product can expose you to chemicals including Lead
and Lead Compounds, which are known to the State of California to
cause cancer and birth defects or other reproductive harm. For more
information, go to www.P65Warnings.ca.gov.
Treatment Procedure
• elements™ IC system can only be used with Kerr elements gutta-percha
cartridges and heat pluggers.
• The heat pluggers and elements gutta-percha cartridges are designed to
reach high temperatures. Inadvertent contact with patient and operator must
be avoided to prevent accidental burns.
• Do not touch the cartridge needle within one minute after the device is turned
o to avoid potential burn risk. Wait until the Backfill device is completely
cooled down before touching the cap.
• Handle empty elements gutta-percha cartridges by the plastic locknut only.
Other portions could be hot and could result in a serious burn.
Use, Repairs and Service
• For use by qualified and trained personnel only.
• U.S. federal law restricts the sale of this device by or on the order of a
healthcare professional.
• To reduce the risk of electrical shock, do not remove charging cover. Refer
servicing to qualified service personnel.
• Only use the specified Kerr Endodontics transformer and power cords.
• Use of other accessories that are not authorized for use in connection with this
device may cause malfunction and compromise patient safety.
• No modification of this equipment is allowed.
• When transporting the device, use the original packaging provided by
manufacturer to prevent accidental activation of the unit or any damage to
the device itself.
Replacing or Shipping the Battery
• Only use Kerr Endodontics batteries designated for this system. Use of other
batteries may damage the device(s) or cause a malfunction.
• Air or land transportation of the device is allowed if they are in the original
packaging container.
• For shipping batteries within the United States or Internationally, consult
the Department of Transportation’s Pipeline and Hazardous Materials Safety
Administration or the International Air Transport Association guidelines.
PRECAUTIONS
• Do not use in teeth with immature and/or over instrumented root canal apices
unless the apex has been sealed.
• A protective dental dam is highly recommended when using this device.
• For the Backfill device, keep temperature setting above 150°C.
Extruding material at lower temperatures will create more stress on the motor,
and may shorten the device’s life.
• Elements gutta-percha cartridges are for single-patient use.
• The electronic components should not be autoclaved as it will damage the
circuitry.
• Do not spray the devices with any liquids as it may damage the circuitry.
• Do not immerse the gutta-percha cartridges in any liquid and do not autoclave
them.
• Do not allow liquids to collect in the Charging Base or come in contact with the
connector as it may damage the circuitry.
• Do not allow liquids to enter the openings for the heat plugger on the
Downpack device or the elements gutta-percha cartridge on the Backfill device
as it may damage the circuitry.
• Avoid multiple activations of the Downpack device while operating
inside the root canal since prolonged exposure to the high temperatures may
cause damage to the tissues surrounding the tooth (PDL or bone).
ADVERSE REACTIONS
None known.
SYMBOLS
Serial Number
Manufacturer
Manufacturing Date
Authorized Representative in the European Community
Corresponds to MDD 93/42 EEC Including
EN 60601-1 and EN 60601-1-2
This Way Up
CSA Mark with "C/US" Indicator for Certified Products
Precaution/Warning
Fragile, Handle with Care
Stack 12 Maximum
Keep Dry
Type B Applied Part
Temperature Limits for Storage and Transportation
Do Not Autoclave
Humidity Limitation
Do Not Throw into Trash
Pressure Limitation
Part Number
Consult Accompanying Documents
CAUTION: Federal law restricts this device to sale by or on the
order of a dentist
Protected against vertically falling water drops when
enclosure tilted up to 15°. Applies to Backfill and Downpack
devices
077-0901_REVA_ELEMENTS_IC_EU_IFU_BOOK_P24.indb 3 6/13/19 6:21 PM
Other manuals for elements IC
1
Table of contents
Other KERR Dental Equipment manuals

KERR
KERR SonicFill 2 Manual

KERR
KERR elements IC User manual

KERR
KERR DemiPlus User manual

KERR
KERR Demi Ultra User manual

KERR
KERR EndoVac User manual

KERR
KERR OptiBond Solo Plus User manual

KERR
KERR Demi L.E.D Curing Light User manual

KERR
KERR System B HeatSource 1005 Instruction Manual

KERR
KERR DemiPlus User manual

KERR
KERR Elements 8:1 User manual