KEYKING 6630KE User manual

Proximity Keypads Reader
Operation Manual
Model: 6630KE/6630KDE
KEYKING GROUP LIMITED

KEYKING GROUP 6630KE Keypads Reader Operation Manual (1.00)
Page 1
Keyking Group Limited
33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel
website: www.keyking.net E-mail: info@keyking.net
Index
Chapter 1: Summarize.......................................................................................................................2
1.1 Summarize ..........................................................................................................................2
1.2 System Characteristics..................................................................................................3
Chapter 2: 6630KE System Instructions:..........................................................................................4
2.1 6630KE surface:............................................................................................................4
2.2 LED:..............................................................................................................................4
2.3 6630KE Wiring:............................................................................................................5
2.4 Mode setting:.................................................................................................................5
2.3.1 Wiegand 26 Bits................................................................................................6
2.3.2 Wiegand 34 Bits................................................................................................6
2.5 Communication Interface:.............................................................................................6
Chapter 3: Keypads Output..............................................................................................................7
3.1 Keypad Message ...........................................................................................................7
Chapter 4: Installation.......................................................................................................................8
4.1 Install on the wall (Based on Internal Back Box) .........................................................8
4.2 Install on the wall (Based on Surface Back Box)..........................................................9
4.3 Install on the wall (Surface, Without Back Box).........................................................10
4.4 Notes...........................................................................................................................12
Chapter 5: Configuaration...............................................................................................................13
5.1 Application: 6630KX Reader Display Setting..................................................................13
5.2 RS485 to RS232 converter................................................................................................14
5.3 Configuration Steps...........................................................................................................15
5.4 Change clock.....................................................................................................................16
5.4.1 Change clock by Keypads..............................................................................................16
5.4.2 Change clock by Configuration software.......................................................................16
5.4.3 Synchronize Clock by RS485 bus from Panel ...............................................................16

KEYKING GROUP 6630KE Keypads Reader Operation Manual (1.00)
Page 2
Keyking Group Limited
33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel
website: www.keyking.net E-mail: info@keyking.net
Chapter 1: Summarize
1.1 Summarize
Reader Model Define:
66 1 1K D E
Support Card Type:
E: EM; For example: EM4100, TK4100 series.
M: Mifare-; For example: Philips S50, S70 series smart cards.
RC: Mifare Sector; For example: Philips S50, S70 series smart cards.
H: HID Compatible; For example: 1326, 1386 and tags.
T: Temic, like E5557;
S: 15693; For example: Ti series cards.
B: TAP_B, For example: Chinese 2cd Identifitation;
C: TAP_C, Hongkong Metro;
E: EM; Proximity; 125KHz
H: HID Compatible; 125KHz
U: CPU, Mifare, RC; 13.56MHz
B: TAP_B, 2cd China ID; 13.56MHz
C: TAP_C, Hongkong Metro; 13.56MHz
K: Keypads Reader;
11: Model;
66: Series;
D: Display Built-in;

KEYKING GROUP 6630KE Keypads Reader Operation Manual (1.00)
Page 3
Keyking Group Limited
33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel
website: www.keyking.net E-mail: info@keyking.net
1.2 System Characteristics
Technical Parameters:
Power: 12 VDC ± 10%, 200mA
Dimensions: 90mm (H) x 90mm (W) x 22mm (D)
Weight: 200 grams
Operating Frequency:
125KHZ:
E: EM;
H: HID;
T: Temic;
13.56MHZ:
B: TAP_B;
C: TAP_C;
M: Mifare;
RC: Mifare Sector;
S: 15693;
•Read Range: 5 to 15 cm
•LED indicators: Dual LEDs, Blue&Green, or Red&Green.
•Back Ground Light: Blue.
•Display Screen: OLED, Dual Color: Yellow, Blue
Cover Back
90mm
90mm

KEYKING GROUP 6630KE Keypads Reader Operation Manual (1.00)
Page 4
Keyking Group Limited
33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel
website: www.keyking.net E-mail: info@keyking.net
Chapter 2: 6630KE System Instructions:
2.1 6630KE surface:
LED:
2.2 LED:
Blue LED for power indication.
Green LED for card reading indication.
Details of Keypads:
No. Mark Definition Output(BIN) No. Mark Definition Output(BIN)
1 1 Digital 1 0001 7 7 Digital 7 0111
2
2
Digital 2
0010
8
8
Digital 8
1000
3
3
Digital 3
0011
9
9
Digital 9
1001
4
4
Digital 4
0100
10
0
Digital 0
0000
5
5
Digital 5
0101
1
*
Cancel / Start
1010
6 6 Digital 6 0110 12 # Enter / Confirm 1100
LED (Blue&Green)
Back light
Keypads
Door Bell
Clock
Company
J4: Door Bell
J5: RS485
Sync Clcok interface
J2: Wiegand 26/34
J1: Connector

KEYKING GROUP 6630KE Keypads Reader Operation Manual (1.00)
Page 5
Keyking Group Limited
33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel
website: www.keyking.net E-mail: info@keyking.net
2.3 6630KE Wiring:
J2: Wiring Connector (Definition of wiring):
No. Mark Definition Note
1 +12V Power Supply
2 D1 Data 1
3 D0 Data 0
4 LED
LED control, when it was shorted with GND, then LED
will change the color.
5 GND GND, Ground Wire
6 BUZ Buzzer control, when it was shorted with GND, then
Buzzer will beep.
J3: Door Bell:
Normally the 2 wires are open.
When you press Door Bell Key, the 2 wires will be shorted.
2.4 Mode setting:
DIP Switch: Wiegand Selector:
OFF: the reader will output Wiegand 26 bits format.
ON: the reader will output Wiegand 34 bits format.
J4: Door Bell
J5: RS485
Sync Clcok interface
DIP: Wiegand 26/34
J1: Connector

KEYKING GROUP 6630KE Keypads Reader Operation Manual (1.00)
Page 6
Keyking Group Limited
33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel
website: www.keyking.net E-mail: info@keyking.net
2.3.1 Wiegand 26 Bits
Please keep DIP Switch on the OFF, then the reader will output Wiegand 26 bits
format.
2.3.2 Wiegand 34 Bits
Please keep DIP Switch on the ON, then the reader will output Wiegand 34 bits
format.
2.5 Communication Interface:
J5: RS485 Inteface:
Configuration interface with PC.
It can work with IC-232 or RS485HUB converter.
J5:
RS485+
RS485-

KEYKING GROUP 6630KE Keypads Reader Operation Manual (1.00)
Page 7
Keyking Group Limited
33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel
website: www.keyking.net E-mail: info@keyking.net
Chapter 3:Keypads Output
3.1 Keypad Message
The reader will processes the keypad entries in the reader and then transmits the data to the host
system via the Wiegand data lines. The reader outputs each key as an ASCII encoded hexadecimal
digit. The decoding of the message sent through the Wiegand interface is the only processing required
of the host system. The user interface has been implemented in the most generic fashion to give the
integrator the most flexibility.
The keypad message follows a basic format.
0 = 0000 4 = 0100 8 = 1000
1 = 0001 5 = 0101 9 = 1001
2 = 0010 6 = 0110 * = 1010
3 = 0011 7 = 0111 # = 1011
The reader will transmit every key value individually, after it was pushed.
For example:
If you push “1”, then the reader will transmit “0001” to the host (Panel or controller).
If you push “1” and “2”, then the reader will transmit “0001” to the host (Panel or controller), then
tranmit “0010” to the host.

KEYKING GROUP 6630KE Keypads Reader Operation Manual (1.00)
Page 8
Keyking Group Limited
33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel
website: www.keyking.net E-mail: info@keyking.net
Chapter 4: Installation
Installation Procedure:
4.1 Install on the wall (Based on Internal Back Box)
1. Install a Reader Back Box inside wall:Determine an appropriate mounting position for the
reader. Install a single or double standard electrical box (86*86mm) inside wall. If mounting to a
metal surface, drill two 7/64 (.109) inch holes and use the enclosed self tapping screws for
mounting.
a). Reader Back Box (Standard Electronic Box, single)b). Reader Back Box (Double)
2. Route: Route the interface cable from the reader to the Host.
3. Wiring: Install all wires to the green connector according below image.
4. Plug the Green Connector: Plug the green connector to the reader socket.
5. Set the JUMPER (Output mode): select W26 or W34 bits output of reader.
6. Mount the reader body: Mount the reader body to the Electronic Box (Reader Back Box) using the
two screws. Two #6-32 x 1 inch screws are provided for mounting to a gang box or metal surface.
7. Put the top cover and face plate.

KEYKING GROUP 6630KE Keypads Reader Operation Manual (1.00)
Page 9
Keyking Group Limited
33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel
website: www.keyking.net E-mail: info@keyking.net
4.2 Install on the wall (Based on Surface Back Box)
1. Install a Reader Back Box on wall:Determine an appropriate mounting position for the reader.
Install a single or double standard electrical box (86*86mm) on the wall using 4 screws.
a). Reader Back Box (Surface, Standard Electronic Box, single)
2. Route: Route the interface cable from the reader to the Host.
3. Wiring: Install all wires to the green connector according below image.
4. Plug the Green Connector: Plug the green connector to the reader socket.

KEYKING GROUP 6630KE Keypads Reader Operation Manual (1.00)
Page
10
Keyking Group Limited
33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel
website: www.keyking.net E-mail: info@keyking.net
5. Set the JUMPER (Output mode): select W26 or W34 bits output of reader.
6. Mount the reader body: Mount the reader body to the Electronic Box (Reader Back Box) using the
two screws which isф4, 30mm length.
7. Put the top cover and face plate.
4.3 Install on the wall (Surface, Without Back Box)
1. Drill a
ф30
hole on the wall:Drill a ф30 hole using a professional drill.
a). ф30 drill, professional tool b). A hole on the wall, ф30
Note: This drill can drill the metal wall and wood wall, can not drill stone or cement wall.
2. Route: Route the interface cable from the reader to the Host.
3. Wiring: Install all wires to the green connector according below image.

KEYKING GROUP 6630KE Keypads Reader Operation Manual (1.00)
Page
11
Keyking Group Limited
33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel
website: www.keyking.net E-mail: info@keyking.net
4. Plug the Green Connector: Plug the green connector to the reader socket.
5. Set the JUMPER (Output mode): select W26 or W34 bits output of reader.
6. Mount the reader body: Mount the reader body to the Electronic Box (Reader Back Box) using the
two screws which isф4, 30mm length.
7. Put the top cover and face plate.

KEYKING GROUP 6630KE Keypads Reader Operation Manual (1.00)
Page
12
Keyking Group Limited
33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel
website: www.keyking.net E-mail: info@keyking.net
4.4 Notes
Cable Notes:
1) Cable type: Category 5 with shield.
2) Same Ground: the reader and Host must have the same ground. If you use different power supply
for reader and controller, please connect the GND of reader to GND of controller.
3) Max Cable Length: The MAX LENGTH is up to 60 meters from controller to reader.
4) Shield: Shield wire should be connected to GND of controller.
Other Notes:
1) Metal disturbing:the reader can not be installed on the metal wall, otherwise it will affect
the read range. Sometimes the reader can not read cards. So you should avoid the metal when
you install the reader.

KEYKING GROUP 6630KE Keypads Reader Operation Manual (1.00)
Page
13
Keyking Group Limited
33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel
website: www.keyking.net E-mail: info@keyking.net
Chapter 5: Configuaration
5.1 Application: 6630KX Reader Display Setting
6630KX Reader Display Setting:It is an application to configure 6630 series reader & TC419.
Before you run this application, please make sure you have a converter (IC-232) for 6630 Series
reader.
Before you run this application, please make sure there is a free serial port in your PC.
Run 6630KX Card Reader Display Setting application, you will see below image #5-1.
Image #5-1
Serial Port: You should select a serial port to communicate with 6630 series reader, like COM1.
Click Open or Close button to open/close the serial port.
Language:You can choose Chinese or English, then the message of the reader will follow the
option you ticked.
Display Mode:You can "Title + Clock" or "Title + Text"
Title +Clock:You can type your company name, and select the position (Left, Center, Right)
Message Box

KEYKING GROUP 6630KE Keypads Reader Operation Manual (1.00)
Page
14
Keyking Group Limited
33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel
website: www.keyking.net E-mail: info@keyking.net
which should be on the display.
Title +Text:3 lines Text. You can type "1st Line Text", "2cd Line Text", and "3rd line Text" (Left,
Center, Right) which should be on the display.
Keypad Mode:
Visual (1234): The display will show what you press. For example: if you press “1234”, then you will see
“1234” on the display.
Mask (****): The display will show “*” no matter what you press. For example: if you press “1”, then you
will see “****” on the display.
ScreenSaver:You should choose the screen saver time, and once you select it, the display
message will disappear after this time. 0 means never screen saver (0=unlimited).
Download Current Time: You can get the clock from PC, and download to the reader.
Selected: You will get the current time from PC, and download to the reader. Then the reader clock will
be the same with your PC.
UnSelected: You will not download the current time of PC to the reader. Then the reader clock will
display the old clock only.
Clear: It will clear all messages of message box after you click Clear button.
5.2 RS485 to RS232 converter
You can use any RS485 to RS232 converter between 6630K and PC application.
For example: IC-232 or RS485HUB. Of course you can use another brand converter also, but please
make sure it support 9600Bps Baud Rate.
Image #5-2
Please make sure the Baud Rate is 9600Bps.
If you use IC-232 conver, please put DIP1, DIP3,DIP4 are ON position and DIP2 is OFF.
If you use RS485HUB, you need no care about the baud rate.

KEYKING GROUP 6630KE Keypads Reader Operation Manual (1.00)
Page
15
Keyking Group Limited
33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel
website: www.keyking.net E-mail: info@keyking.net
5.3 Configuration Steps
When you do configuration, need no give power supply to reader. The reader will get power from
USB of PC.
Before you connect the cable, please make sure you already take out the power supply for 6630
series reader.
1. Connecting:
Plug white connector of Downloader to J5 on the back of reader.
Connect 485+ of J5 to 485+ of IC-232, 485- of J5 to 485- of IC-232.
Regarding IC-232, please put DIP1, DIP2, DIP3, DIP4 are ON position, let it work under 38400Bps.
Give IC-232 converter power supply.
Plug the DB9 female connector of cable to Serial Port of PC.
Plug the DB9 female connector of cable to IC-232.
Image #5-3 Diagram for IC-232
After connecting, the reader will work, and you will see the display information.
2. Configuring by 6630KX Reader Display Setting:
Choose a Serial Port, and Open it.
Type the Company Name (like: Keyking Group), and choose the position.
Choose a kind of Keypad Mode, Visual or Mask.
Choose “Download current time” or not.
Click OK Button. You will see “Succeed to configure reader” message in the message box.
Done. You will see the changes.

KEYKING GROUP 6630KE Keypads Reader Operation Manual (1.00)
Page
16
Keyking Group Limited
33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel
website: www.keyking.net E-mail: info@keyking.net
5.4 Change clock
5.4.1 Change clock by Keypads
Steps:
1. Power off 6630KE.
2. Power on 6630KE.
3. You will message “Update Clock/Time?”
4. Type “201509251601”according “YYYYMMDDHHMM”, and press “#” to confirm
5. Done
5.4.2 Change clock by Configuration software
Please follow 5.3.
You can change clock by keypads also.
5.4.3 Synchronize Clock by RS485 bus from Panel
6630KDM Diagram:
1. Wiegand Signal wires (+12V,GND,D0,D1,LED,Buzzer).
2. RS485 Sync clock wires: RVV2*0.5 to Access control Panel.

KEYKING GROUP 6630KE Keypads Reader Operation Manual (1.00)
Page
17
Keyking Group Limited
33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel
website: www.keyking.net E-mail: info@keyking.net
Wiegand Cable RS485 Sync clock wire