Keysight Technologies M1740A User manual

Getting Started
Guide
Keysight Wireless Test Sets
M1740A mmWave Transceiver

Notices
©Keysight Technologies, Inc. 2018
No part of this manual may be
reproduced in any form or by any
means (including electronic storage
and retrieval or translation into a
foreign language) without prior
agreement and written consent from
Keysight Technologies, Inc. as
governed by United States and
international copyright laws.
Trademark Acknowledgments
Manual Part Number
M1740-90001
Edition
Edition 1, October 2018
Supersedes August 2018
Printed in USA/Malaysia
Published by:
Keysight Technologies
1400 Fountaingrove Parkway
Santa Rosa, CA 95403
Warranty
THE MATERIAL CONTAINED IN THIS
DOCUMENT IS PROVIDED “AS IS,”
AND IS SUBJECT TO BEING
CHANGED, WITHOUT NOTICE, IN
FUTURE EDITIONS. FURTHER, TO
THE MAXIMUM EXTENT PERMITTED
BY APPLICABLE LAW, KEYSIGHT
DISCLAIMS ALL WARRANTIES,
EITHER EXPRESS OR IMPLIED WITH
REGARD TO THIS MANUAL AND
ANY INFORMATION CONTAINED
HEREIN, INCLUDING BUT NOT
LIMITED TO THE IMPLIED
WARRANTIES OF
MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE.
KEYSIGHT SHALL NOT BE LIABLE
FOR ERRORS OR FOR INCIDENTAL
OR CONSEQUENTIAL DAMAGES IN
CONNECTION WITH THE
FURNISHING, USE, OR
PERFORMANCE OF THIS
DOCUMENT OR ANY INFORMATION
CONTAINED HEREIN. SHOULD
KEYSIGHT AND THE USER HAVE A
SEPARATE WRITTEN AGREEMENT
WITH WARRANTY TERMS
COVERING THE MATERIAL IN THIS
DOCUMENT THAT CONFLICT WITH
THESE TERMS, THE WARRANTY
TERMS IN THE SEPARATE
AGREEMENT WILL CONTROL.
Technology Licenses
The hardware and/or software
described in this document are
furnished under a license and may be
used or copied only in accordance
with the terms of such license.
U.S. Government Rights
The Software is “commercial
computer software,” as defined
by Federal Acquisition Regulation
(“FAR”) 2.101. Pursuant to FAR
12.212 and 27.405-3 and
Department of Defense FAR
Supplement (“DFARS”) 227.7202,
the U.S. government acquires
commercial computer software
under the same terms by which
the software is customarily
provided to the public.
Accordingly, Keysight provides
the Software to U.S. government
customers under its standard
commercial license, which is
embodied in its End User License
Agreement (EULA), a copy of
which can be found at
http://www.keysight.com/find/sweula
The license set forth in the EULA
represents the exclusive authority
by which the U.S. government
may use, modify, distribute, or
disclose the Software. The EULA
and the license set forth therein,
does not require or permit,
among other things, that
Keysight: (1) Furnish technical
information related to
commercial computer software
or commercial computer
software documentation that is
not customarily provided to the
public; or (2) Relinquish to, or
otherwise provide, the
government rights in excess of
these rights customarily provided
to the public to use, modify,
reproduce, release, perform,
display, or disclose commercial
computer software or
commercial computer software
documentation. No additional
government requirements
beyond those set forth in the
EULA shall apply, except to the
extent that those terms, rights, or
licenses are explicitly required
from all providers of commercial
computer software pursuant to
the FAR and the DFARS and are
set forth specifically in writing
elsewhere in the EULA. Keysight
shall be under no obligation to
update, revise or otherwise
modify the Software. With
respect to any technical data as
defined by FAR 2.101, pursuant
to FAR 12.211 and 27.404.2 and
DFARS 227.7102, the U.S.
government acquires no greater
than Limited Rights as defined in
FAR 27.401 or DFAR 227.7103-5
(c), as applicable in any technical
data.
Safety Notices
A CAUTION notice denotes a hazard. It
calls attention to an operating
procedure, practice, or the like that,
if not correctly performed or adhered
to, could result in damage to the
product or loss of important data. Do
not proceed beyond a CAUTION
notice until the indicated conditions
are fully understood and met.
A WARNING notice denotes a hazard.
It calls attention to an operating
procedure, practice, or the like that,
if not correctly performed or adhered
to, could result in personal injury or
death. Do not proceed beyond a
WARNING notice until the indicated
conditions are fully understood and
met.

3
Where to Find the Latest Information
Documentation is updated periodically. For the latest information about these products, including instrument software
upgrades, application information, and product information, browse to one of the following URLs, according to the name
of your product:
http://www.keysight.com/find/m1740a
To receive the latest updates by email, subscribe to Keysight Email Updates at the following URL:
http://www.keysight.com/find/MyKeysight
Information on preventing instrument damage can be found at:
www.keysight.com/find/PreventingInstrumentRepair
Is your product software up-to-date?
Periodically, Keysight releases software updates to fix known defects and incorporate product enhancements. To search
for software updates for your product, go to the Keysight Technical Support website at:
http://www.keysight.com/find/techsupport

4

Contents
Getting Started Guide 5
Table of Contents
Safety & Environmental Information 7
Warning Statements and Symbols 8
Safety 9
Safety Compliance 9
Acoustic statement (European Machinery Directive) 9
General Safety Notices 9
Environmental Conditions (Operating) 10
Environmental Information 10
EMC (Electromagnetic Compatibility) 11
South Korean Class A EMC declaration 11
Declaration of Conformity 11
Ventilation 12
Power requirements 12
Using Accessories 12
Weight and Dimensions 13
Protecting against electrostatic discharge 13
Instrument Maintenance 14
Cleaning the Instrument 14
Cleaning the Connectors 14
Quick Start 15
Initial Inspection 16
Shipping Problems? 16
Location and Mounting 17
Exterior Features 19
DUT-Facing Side 20
Instrument-Facing Side 22
Port Connections to Measurement Instruments 23
Labels and Symbols 24
Functionality 25
Simplified Block Diagram 26
Configuration Example: M1740A used with E7760B 28
Configuration Example: M1740A used with the E7770A CIU 31

7
Keysight Wireless Test Set
M1740A mmWave Transceiver
Getting Started Guide
1 Safety & Environmental Information
The following topics can be found in this section:
“Warning Statements and Symbols” on page 8
“Safety” on page 9
“Environmental Conditions (Operating)” on page 10
“EMC (Electromagnetic Compatibility)” on page 11
“Ventilation” on page 12
“Power requirements” on page 12
“Using Accessories” on page 12
“Weight and Dimensions” on page 13
“Protecting against electrostatic discharge” on page 13
“Instrument Maintenance” on page 14

8 Getting Started Guide
Safety & Environmental Information
Warning Statements and Symbols
Warning Statements and Symbols
Caution and Warning notices are used in this document are described below.
See also: “Labels and Symbols” on page 24.
A CAUTION notice denotes a hazard. It calls attention to an operating
procedure, practice, or the like that, if not correctly performed or adhered to,
could result in damage to the product or loss of important data. Do not proceed
beyond a CAUTION notice until the indicated conditions are fully understood
and met.
A WARNING denotes a hazard. It calls attention to an operating procedure,
practice or the like that, if not correctly performed or adhered to, could result in
personal injury or death. Do not proceed beyond a WARNING notice until the
indicated conditions are fully understood and met.

Getting Started Guide 9
Safety & Environmental Information
Safety
Safety
This product has been designed and tested in accordance with accepted
industry standards, and has been supplied in a safe condition.The
documentation contains information and warnings that must be followed by
the user to ensure safe operation and to maintain the product in a safe
condition.
Safety Compliance
This product complies with the essential requirements of the European Low
Voltage Directive as well as current editions of the following standards (dates
and editions are cited in the Declaration of Conformity):
— IEC/EN 61010-1
— Canada: CSA C22.2 No. 61010-1
— USA: UL std no. 61010-1
Acoustic statement (European Machinery Directive)
Acoustic noise emission
LpA <70 dB
Operator position
Normal operation mode per ISO 7779
General Safety Notices
If this product is not used as specified, the protection provided by the
equipment could be impaired. This product must be used in a normal condition
(in which all means for protection are intact) only.
No operator serviceable parts inside. Refer servicing to qualified personnel. To
prevent electrical shock, do not remove covers.

10 Getting Started Guide
Safety & Environmental Information
Environmental Conditions (Operating)
Environmental Conditions (Operating)
This product is designed for use in the following conditions:
— For indoor use only
— Altitude up to 3000 m
— Temperature 10 to 40°C
— Maximum relative humidity 95% (non-condensing)
Environmental Information
Samples of this product have been type tested in accordance with the Keysight
Environmental Test Manual and verified to be robust against the environmental
stresses of Storage, Transportation and End-use; those stresses include but
are not limited to temperature, humidity, shock, vibration, altitude and power
line conditions.
Test Methods are aligned with IEC 60068-2 and levels are similar to
MIL-PRF-28800F Class 3.
This product is designed for use in INSTALLATION CATEGORY II and
POLLUTION DEGREE 2, per IEC 61010-1 Third Edition and 664 respectively.

Getting Started Guide 11
Safety & Environmental Information
EMC (Electromagnetic Compatibility)
EMC (Electromagnetic Compatibility)
This product complies with the essential requirements of the European
Directive as well as current editions of the following standards (dates and
editions are cited in the Declaration of Conformity):
— IEC/EN 61326-1
— CISPR Pub 11 Group 1, class A
— AS/NZS CISPR 11
— ICES/NMB-001
This ISM device complies with Canadian ICES-001.
Cet appareil ISM est conforme a la norme NMB-001 du Canada.
South Korean Class A EMC declaration
This equipment is Class A suitable for professional use and is for use in
electromagnetic environments outside of the home.
Declaration of Conformity
The Declaration of Conformity for any Keysight product can be found on the
website:
http://www.keysight.com/go/conformity

12 Getting Started Guide
Safety & Environmental Information
Ventilation
Ventilation
Power requirements
The M1740A does not have an AC power connection. It is powered by a DC
voltage from the E7760B Wideband Transceiver or the E7770A Common
Interface Unit; this voltage is supplied over the RF Cable Assembly to the
LO/Pwr/Ctrl/IF In connector. The DC supply does not represent a risk of
personal injury.
Using Accessories
When the M1740A is used in connection with the E7760B Wideband
Transceiver or the E7770A Common Interface Unit, use only the RF Cable
Assembly that was supplied with the M1740A to connect it with the other
instrument, and connect it only to the mmW ports on that instrument.
VENTILATION REQUIREMENTS: When installing the instrument(s) into a
cabinet, consideration shall be given to the convection flow into and out of the
cabinet. Consideration shall also be given to the individual instruments to avoid
having the heated discharge of one instrument, now becoming the cooling
intake air for another instrument.
Another area of concern is verification that the maximum ambient operating
temperature of the instrument(s) is not exceeded by cabinet installation.
Keysight recommends forced air convection whenever an instrument(s) are
installed in a cabinet and further recommends that the maximum operating
temperature of the cabinet be reduced 10°C from the lowest, of the maximum
operating temperature of a single instrument.
If there are any concerns or special requirements an Keysight Field Engineer
should be consulted to assure instrument(s) temperature compliance and
performance.used.
The RF Cable Assembly should not be connected to, or disconnected from, the
M1740A while it is suppling DC power from the E7760B or E7770A. This
connection should be made only when the E7760B is powered off, or the cable
is not connected to the E7760B or E7770A. If the LED status indicator on the
front of the M1740A is lit, this indicates that it is powered up and the cable
should not be disconnected.

Getting Started Guide 13
Safety & Environmental Information
Weight and Dimensions
Weight and Dimensions
The weight and dimensions of the M1740A are as follows.
—Weight:2.2kg
—Height:66mm
— Width: 139 mm
— Depth: 183 mm
Protecting against electrostatic discharge
Electrostatic discharge (ESD) can damage or destroy electronic components
(the possibility of unseen damage caused by ESD is present whenever
components are transported, stored, or used).
Test equipment and ESD
To help reduce ESD damage that can occur while using test equipment:
• Before connecting any coaxial cable to a test set connector for the first time
each day, momentarily short the center and outer conductors of the cable
together.
• Personnel should be grounded with a 1 MΩresistor-isolated wrist-strap
before touching the center pin of any connector and before removing any
assembly from the test set.
• Be sure that all instruments are properly earth-grounded to prevent
build-up of static charge.
• Perform work on all components or assemblies at a static-safe workstation.
• Keep static-generating materials at least one meter away from all
components.
• Store or transport components in static-shielding containers.
• Always handle printed circuit board assemblies by the edges. This reduces
the possibility of ESD damage to components and prevent contamination of
exposed plating.
Additional information about ESD
For more information about ESD and how to prevent ESD damage, contact the
Electrostatic Discharge Association (http://www.esda.org). The ESD standards
developed by this agency are sanctioned by the American National Standards
Institute (ANSI).
Do not use these first three techniques when working on circuitry with a voltage
potential greater than 500 volts.

14 Getting Started Guide
Safety & Environmental Information
Instrument Maintenance
Instrument Maintenance
Cleaning the Instrument
Cleaning the Connectors
Cleaning connectors with isopropyl alcohol shall only be done with all cables
disconnected, and in a well-ventilated area. Allow all residual alcohol moisture
to evaporate, and the fumes to dissipate prior to energizing the instrument.
Disconnect the M1740A from all cables before cleaning. Use a dry cloth or one
slightly dampened with water to clean the external case parts. Do not attempt
to clean internally.
Keep isopropyl alcohol away from heat, sparks, and flame. Store in a tightly
closed container. The alcohol shall not be stored, or left open, in the area of the
equipment. Use isopropyl alcohol with adequate ventilation to prevent the
combustions of fumes or vapors.
Avoid contact with eyes, skin, and clothing, as isopropyl alcohol causes skin
irritation, may cause eye damage, and is harmful if swallowed or inhaled. It may
be harmful if absorbed through the skin. Wash thoroughly after handling. In case
of spill, soak up with sand or earth. Flush spill area with water. Dispose of
isopropyl alcohol in accordance with all applicable federal, state, and local
environmental regulations.
In case of fire, use alcohol foam, dry chemical, or carbon dioxide; water may be
ineffective.

16 Getting Started Guide
Quick Start
Initial Inspection
Initial Inspection
Inspect the shipping container and the cushioning material for signs of stress.
Retain undamaged shipping materials for future use, as you may wish to ship
the test set to another location or to Keysight Technologies for service. Verify
the contents of the container against the table below.
Shipping Problems?
If the shipping materials are damaged or the contents of the container are
incomplete:
— Contact the nearest Keysight Technologies office.
— Keep the shipping materials for the carrier’s inspection.
— If you must return a test set to Keysight Technologies, use the undamaged
original or comparable shipping materials. See “Returning Your Test Set for
Service” on page 37.
Item Deliverable Description
Getting Started Guide (this
document)
Provides first-time power on
instructions, licensing
information, operating system
information, and general
hardware information.
Keysight M1740A mmWave
Transceiver
RF Cables
(One or more of
M1740-60006 and/or
M1740-60014; quantity
depends on options
ordered at time of
purchase)
In addition to IF and LO signals,
these cables carry control signals
and DC supply voltages from the
E7760B Wideband Transceiver
(M1740-60006 cable) or from the
E7770A Common Interface Unit
(M1740-60014 cable).
The M1740A is often used in conjunction with the E7760B Wideband Transceiver
or the E7770A Common Interface Unit, but those are separate purchase and are
not always shipped with the M1740A.

Getting Started Guide 17
Quick Start
Location and Mounting
Location and Mounting
It is recommended to suspend the transceiver above the Device Under Test
(DUT), with the mmWave port pointed downwards at the DUT, so that heat
given off by the transceiver will rise away from the DUT. Leave a minimum
clearance of 2.5 inches (7 cm) around the transceiver. Also, ensure there is
enough room to attach all necessary cables between the transceiver and other
devices.

18 Getting Started Guide
Quick Start
Location and Mounting

20 Getting Started Guide
Exterior Features
DUT-Facing Side
DUT-Facing Side
Figure 3-1 M1740A, DUT-facing side
The features are described in the following table.
Figure 3-2 M1740A regulatory labels
See “Labels and Symbols” on page 24 for information about these labels.
Number Name Description
1 RF Tx/Rx 1 (2.4 mm connector) A port which can be configured either to supply a mm wave signal to the DUT, or
to receive it from the DUT.
2 RF Tx/Rx 2 (2.4 mm connector) A port which can be configured either to supply a mm wave signal to the DUT, or
to receive it from the DUT.
Table of contents
Other Keysight Technologies Transceiver manuals

Keysight Technologies
Keysight Technologies M1749B User manual

Keysight Technologies
Keysight Technologies S9101A User guide

Keysight Technologies
Keysight Technologies M9411A User manual

Keysight Technologies
Keysight Technologies M9410A User manual

Keysight Technologies
Keysight Technologies M9420A User manual

Keysight Technologies
Keysight Technologies M1650A User manual

Keysight Technologies
Keysight Technologies S9130A User manual

Keysight Technologies
Keysight Technologies S9106AC-42D User guide

Keysight Technologies
Keysight Technologies M9420A User manual

Keysight Technologies
Keysight Technologies M9410A User manual