Description Upgrade number Additional information
Windows Embedded Standard 7 N9094AK-W7X
N9094AK-PC4
Upgrade existing 32-bit processor with Windows XP to a 64-bit perfor-
mance processor with Windows 7, 8 GB RAM and removable solid-state
drive; must be ordered under N9038AK; requires PC2
Increase frequency from 3.6 to 8.4 GHz N9038AK-F01 Requires Option 503
Increase frequency from 3.6 to 26.5 GHz N9038AK-F03 Requires Option 503
Increase frequency from 3.6 to 44 GHz N9038AK-F04 Requires Option 503
Increase frequency from 8.4 to 26.5 GHz N9038AK-F07 Requires Option 508
Increase frequency from 8.4 to 44 GHz N9038AK-F08 Requires Option 508; for Serial prex less than MY/SG5322, upgrade
kits include N9038AK-HL4
Increase frequency from 26.5 to 44 GHz N9038AK-F13 Requires Option 526; for Serial prex less than MY/SG5322, upgrade
kits include N9038AK-HL4
Increase analysis bandwidth from 10 MHz to 25 MHz1N9038AK-B25
Additional removable solid-state drive N9094AK-WX7
N9094AK-SSD
For Windows 7 operating systems only, provides additional removable
solid-state drive; not compatible with Win XP systems; requires PC4 or
greater; additional Windows XP drive last order date was March 1, 2015;
must be ordered under N9038AK
Add Y-axis screen video output N9038AK-YAS
USB DVD-ROM/CD-R/RW drive N9038AK-DVR
Keyboard, USB interface N9038AK-KYB
US 65 key USB keyboard N9038AK-KB2
Rack mount and handle kit N9038AK-1CP Not compatible with Options 1CM and 1CN
Front handle kit N9038AK-1CN Not compatible with Options 1CM and 1CP
Rack mount kit N9038AK-1CM Not compatible with Options 1CP and 1CN
External source control kit N9038AK-ESC
Type "N" connector for input N9038AK-CNF Makes both inputs 1 and 2 type-N connectors
3.5 mm connector for input N9038AK-C35 Input 2 remains type-N
Hardware to enable monitor spectrum, APD, and time
domain scan
N9038AK-HL4 Includes high-performance digital signal processor (Option DP2) and
wideband second IF rear panel output (Option CR3)
1. At the time of manufacture, the hardware related to many of these options was fully adjusted and the option performance was veried to be
within its warranted specications. Within one year of the initial calibration date of the analyzer, this option is fully calibrated with no further
adjustment or verication testing.
2. If this analyzer has been adjusted as part of a repair or calibration during its rst year, or if the analyzer is more than one year old, additional
adjustment and performance verication tests are required to ensure that some newly installed options are functioning properly. However,
the completion of these tests does not guarantee that the analyzer meets all warranted specications.
Instrument Upgrades
Upgrade your existing MXE
Fast license-key upgrades for performance options that do not require addi-
tional hardware:
1. Place an order for the upgrade with Keysight and request to receive the
software entitlement certicate through email
2. Redeem the certicate through the Web by following the instructions on
the certicate
3. Install the license le and latest software in the MXE
4. Begin using the new capability 1, 2
Installation and testing information is available at:
www.keysight.com/nd/mxe_upgrades
You Can Upgrade!
Options can be
added after your
initial purchase.
Most X-Series options are
license-key upgradeable.
UP
GRADE
06 | Keysight | N9038A MXE EMI Receiver - Conguration Guide