Product Description
RBW201-C, RBW202-C, RBW204-C, RBW205-C
Room Control Module
Application
Room control modules with room temperature sensor,
manual room temperature setpoint configuration and
LED status display for the following room controllers and
automation systems:
■RCN150-L, RCN151-L, RCN152-L, RCN155-L
■RCC200-L or RCN200-L
■RCN420-B
■DDC4000, DDC420
Different variants with a graded range of functions are
available: Set room temperature, manual and automatic
fan control, presence button (present/absent).
Content Page
Important Information Regarding Product Safety ..................................................................................................2
Item........................................................................................................................................................................3
Technical Data.....................................................................................................................................................3
Accessories (not included in delivery) .................................................................................................................3
Compatibility ........................................................................................................................................................4
Dimensions..........................................................................................................................................................4
Connection...........................................................................................................................................................4
Mounting ................................................................................................................................................................7
Using the Software ................................................................................................................................................9
Setting the room temperature..............................................................................................................................9
Energy saving function (RBW202, RBW205) ......................................................................................................9
Energy saving function (RBW202, RBW205; with schedule in RCx200-L) .......................................................10
CAN Address Setting...........................................................................................................................................11
Installation............................................................................................................................................................11
Notes for service technicians...............................................................................................................................12

APage 2 / 12
Product DescriptionRBW201-C, RBW202-C, RBW204-C, RBW205-C
Datasheet 1.10-60.001-01-EN Issue 2017-07-20
Important Information Regarding Product Safety
Safety Instructions
This data sheet contains information on installing and commissioning the product "RBW201-C,
RBW202-C, RBW204-C, RBW205-C". Each person who carries out work on this product must have
read and understood this data sheet. If you have any questions that are not resolved by this data
sheet, you can obtain further information from the supplier or manufacturer.
If the product is not used in accordance with this data sheet, the protection provided will be impaired.
Applicable regulations must be observed when installing and using the device. Within the EU, these
include regulations regarding occupational safety and accident prevention as well as those from the
VDE (Association for Electrical, Electronic & Information Technologies). If the device is used in other
countries, it is the responsibility of the system installer or operator to comply with local regulations.
Mounting, installation and commissioning work on the devices may only be carried out by qualified
technicians. Qualified technicians are persons who are familiar with the described product and who
can assess given tasks and recognize possible dangers due to technical training, knowledge and
experience as well as knowledge of the appropriate regulations.
Legend
WARNING
Indicates a hazard of medium risk which can result in death or severe bodily injury if it is not avoided.
CAUTION
Indicates a hazard of low risk which can result in minor or medium bodily injury if it is not avoided.
!CAUTION
Indicates a hazard of medium risk which can result in material damage or malfunctions if it is not
avoided.
NOTE
Indicates additional information that can simplify the work with the product for you.
Notes on Disposal
For disposal, the product is considered waste from electrical and electronic equipment (electronic
waste) and must not be disposed of as household waste. Special treatment for specific components
may be legally binding or ecologically sensible. The local and currently applicable legislation must be
observed.

A
Page 3 / 12
Datasheet 1.10-60.001-01-EN
RBW201-C, RBW202-C, RBW204-C, RBW205-CProduct Description
Issue 2017-07-20
Item
Technical Data
Accessories (not included in delivery)
RBW201-C Room control module with room temperature sensor, setting of room temperature set-
point made using knob (with LED indicator)
RBW202-C All features of RBW201-C plus presence button and LED indicator
RBW204-C All features of RBW201-C plus buttons for fan control (higher/lower) and a button for
automatic fan mode, each with LED indicators
RBW205-C All features of RBW201-C plus presence button, buttons for fan control (higher/lower)
and a button for automatic fan mode, each with LED indicators
Nominal voltage DC 12 V ± 20%, 0.72 W
Power consumption 0.6 W (LEDs switched off), 0.72 W (LEDs switched on)
Measured value Room temperature of spaces in homes or commercial premises
Measuring system Integrated digital room sensor
Controls Knob for setting room temperature setpoint
Keys:
Fan control level increasing: Fan on, increased speed
Fan control level decreasing: Decreased speed, fan off
Fan in automatic mode (fan speed specified by controller)
Presence button (power save button): Switch to present or absent
Indicator ■Red LED: higher room temperature setpoint
■Blue LED: lower room temperature setpoint
■Green LEDs: Feedback for fan level , automatic mode, presence button
(present)
Interfaces CAN bus, 4-wire terminal or RJ9
Measuring range 0 °C to 50 °C
Relative measuring accu-
racy
0.1 K
Housing Plastic housing, RAL 9010 (pure white)
Other colors on request
Protection class III
Degree of protection IP30
Ambient temperature 0 °C to 50 °C
Ambient humidity During operation: 20% to 80% r.h.; non-condensing
Out of operation: 5% to 90% r.h.; non-condensing
Installation Screw mounting on standard flush-mounted box
Weight 0.1 kg
Dimensions WxHxD mm 90 x 90 x 32,5
Depth in wall 9.5
Z146 Adapter frame for direct wall mounting

APage 4 / 12
Product DescriptionRBW201-C, RBW202-C, RBW204-C, RBW205-C
Datasheet 1.10-60.001-01-EN Issue 2017-07-20
Compatibility
Can be connected to:
■RCN150-L, RCN151-L, RCN152-L, RCN155-L, RCC200-L, RCN200-L or RCN420-B room
controllers
up to four room control modules depending on the application
■DDC420 automation station
up to 3 room control modules
■DDC4200-L, DDC4200, DDC4002, DDC4400, DDC4200e, DDC4002e or DDC4400e automation
stations
depending on the fieldbus, up to nine room control modules to addresses 1 to 9
Dimensions
- Z146
Connection
90.0 23,0
16,0
90,0
9,5
Ø50
83,0
83,0
8,4
R 35,0
49,5
49,5
14,0
+12V=
C–
RJ
0V
C+
17 18 19 20

A
Page 5 / 12
Datasheet 1.10-60.001-01-EN
RBW201-C, RBW202-C, RBW204-C, RBW205-CProduct Description
Issue 2017-07-20
Sample connection
- RCC200-L
RBW20X-C
RBW30X-C
DDC420
21
2019 22
+-
0V
12VDC
CAN -
CAN +
0V DC
+12V DC
19
1817 20
RBW20X-C
RBW30X-C
RCN420-B
21
2019 22
+-
0V
12VDC
CAN -
CAN +
0V DC
+12V DC
19
1817 20
52 5350 51
98
7
16
15
1032
1
6
5
4
57
60
59
58
GND
K1 P1
GND
K3
GND
P3
GND
K2 P2
1312
11 14
GND
K4
GND
P4
GND
P5
+12V=
0V
C
+
C
í
AB
LON
LN
L L N N AB
K6K5 K7
42 4340 4137 38
K8
:
18
17
GND
P6
20
19
GND
P7
22
21
GND
P8
24
23
GND
K9
26
25
GND
K10
NL
17 18 19 20 17 18 19 20
+12V=
0V
C
+
C
í
17 18 19 20
RJ
17 18 19 20
17 18 19 20 17 18 19 20
RJ
RJ
230V~
230V~ 230V~
230V~ 24V=
$$

APage 6 / 12
Product DescriptionRBW201-C, RBW202-C, RBW204-C, RBW205-C
Datasheet 1.10-60.001-01-EN Issue 2017-07-20
- RCN155-L
+12V=
0V
C
+
C
í
17 18 19 20
17 18 19 20
RJ
59 6057 58
1817
L1N
2
1
Y4 0V
786
5
41110 12
9
32 33 34 35
30 31
26 27 28 29
24 25 50 51
BA
LON
Y2
+24V
0V
230V~
10 A
K10
K2K1
24V~/
230V~
K7 K8 K9
3 A (2 A)
24V~/
230V~
24V~/
230V~
P5 P6
0..10V
+
+
P1 P2
KP10
++
P3 P4
NTC10K
max. 0,4 A
59 6057 58

A
Page 7 / 12
Datasheet 1.10-60.001-01-EN
RBW201-C, RBW202-C, RBW204-C, RBW205-CProduct Description
Issue 2017-07-20
Mounting
!CAUTION
Installation and removal may only be carried out by qualified technicians when the power is switched
off.
Choose an installation location that is subject to the air flow of the room to ensure that the room
controller can quickly and accurately measure the room temperature.
Installation on a standard flush-mounted box (RJ9 connector)
1,5m
= 0,5m
≤ 2,5
1 2
Z178
3 4
5 6

APage 8 / 12
Product DescriptionRBW201-C, RBW202-C, RBW204-C, RBW205-C
Datasheet 1.10-60.001-01-EN Issue 2017-07-20
Installation on a standard flush-mounted box (4-wire connection to terminal)
Direct wall mounting with Z146 adapter frame (4-wire on terminal)
1 2 3 4
5 6
Z146
1
49,5 mm
2 3
RJ9
4
RJ9
3 mm
5 6 7 8
910 11

A
Page 9 / 12
Datasheet 1.10-60.001-01-EN
RBW201-C, RBW202-C, RBW204-C, RBW205-CProduct Description
Issue 2017-07-20
Using the Software
NOTE
The control module switches to standby mode after 10 seconds: All LEDs are switched off.
To make settings: Press any key or rotate the knob.
Setting the room temperature
If you turn the knob, the function is activated:
►Rotate the knob to the left: Reduce the temperature.
►Rotate the knob to the right: Increase the temperature.
Depending on the selected temperature setting, the display of the LEDs changes.
■Neither of the two LEDs is illuminated: The average value is set.
■Blue LED illuminated: Increase by degrees (°C) to full intensity (-10 °C in comparison to the
average value).
■Red LED illuminated: Decrease by degrees (°C) to full intensity (+10 °C in comparison to the
average value).
Energy saving function (RBW202, RBW205)
►If you leave the room for a longer period of time, switch the presence button to “Absent”, LED
(OFF).
The energy saving function is activated and the temperature is set to a preconfigured value
(cannot be adjusted).
►When you return to the room, switch the presence button to “Present”, LED (ON).
The energy saving function is switched off. You can adjust the temperature to a value of your
choice.
1 Knob Rotate: Set the value (e.g. temperature). Left: Lower it (blue LED).
Right: Raise it (red LED)
2 Presence button (power save button): Switch between “Present” and
“Absent”. Green LED (ON): “Present”
(RBW202, RBW205)
3 Fan in automatic mode: Fan speed specified by the controller. Green
LED (ON)
(RBW204, RBW205)
4 Reduce the speed, fan off. Four green LEDs: Max. to min. fan level
display (RBW204, RBW205)
5 Fan on, increase speed. Four green LEDs: Min. to max. fan level dis-
play (RBW204, RBW205)
5
4
3
2
1

APage 10 / 12
Product DescriptionRBW201-C, RBW202-C, RBW204-C, RBW205-C
Datasheet 1.10-60.001-01-EN Issue 2017-07-20
Energy saving function (RBW202, RBW205; with schedule in RCx200-L)
If the schedule is activated:
►If you leave the room for a longer period of time, switch the presence button to “Absent”, LED
(OFF).
The energy saving function is activated and the temperature is decreased to a preconfigured
value. The temperature cannot be adjusted using the knob.
►When you return to the room, switch the presence button to “Present”, LED (ON).
The energy saving function is switched off. The comfort temperature is activated. You can
adjust the temperature with the knob.
If the schedule switches from active to inactive, the presence button switches to “Absent”, LED (OFF).
►Switch the presence button to “Present” to re-activate the comfort temperature, LED (ON). The
comfort temperature is activated for a limited period of time.
After the period of time has expired, the presence button switches to “Absent”, LED (OFF).
The energy saving function is activated again.

A
Page 11 / 12
Datasheet 1.10-60.001-01-EN
RBW201-C, RBW202-C, RBW204-C, RBW205-CProduct Description
Issue 2017-07-20
CAN Address Setting
The address switch (1) is located on the PCB of the room control module (rear of device).
Address setting:
■For RCN150-L, RCN151-L, RCN152-L, RCN155-L, RCC200-L or RCN200-L with basic appli-
cation: Address 1 for main room,
Address 2 for secondary room
■For RCN150-L, RCN151-L, RCN152-L, RCN155-L, RCC200-L, RCN200-L or RCN420-B
configured with PS4000: Address 1 to 4 for room 1 to 4
■DDC4000: Address 1 to 9
■DDC420: Address 1 to 9
1 Address switch
Installation
■Online installation with the RCxxxx-L technolon® room controller:
The RCxxxx-L technolon® room controller can also be identified directly on the room control
module using a magnet (3). To do so, guide a magnet (3) along the right side of the RBW2xx-C
room control module.
This triggers the service PIN in the RCxxxx-L room controller internally. This is indicated by a
service LED (4) on the top part of the housing on the room control modules that lights up green.
1
3
4

APage 12 / 12
Product DescriptionRBW201-C, RBW202-C, RBW204-C, RBW205-C
Datasheet 1.10-60.001-01-EN Issue 2017-07-20
Notes for service technicians
Additional indicators
■The red and blue LEDs on the knob remain illuminated: Field bus error (duplicate address, short
circuit, interchanged bus).
■After interruption of the power supply, red and blue LEDs illuminate for approx. eight seconds until
the device is has logged on.
■The LED on the top part of the housing under the ventilation slots illuminates briefly once: When
logging onto the controller through the triggering of the dry reed contact on the external wall of the
housing (using magnets).
This manual suits for next models
3
Table of contents
Other Kieback&Peter Control Unit manuals

Kieback&Peter
Kieback&Peter RPW414-FTL-902-ALC User manual

Kieback&Peter
Kieback&Peter RBW322-FTL Technical specifications

Kieback&Peter
Kieback&Peter RBW301-C User manual

Kieback&Peter
Kieback&Peter BMA0804 User manual

Kieback&Peter
Kieback&Peter DDC111 User manual

Kieback&Peter
Kieback&Peter FBM45 User manual

Kieback&Peter
Kieback&Peter FSM21 Operating and installation instructions

Kieback&Peter
Kieback&Peter RBW322-FTL-315 User manual

Kieback&Peter
Kieback&Peter BMD1200 Technical specifications

Kieback&Peter
Kieback&Peter RBW101 Technical specifications