INSTALLATION/OPERATING
INSTRUCTIONS FOR 7DAY
ELECTRONIC IMMERSION HEATER TIMER
-T106-C
WIRING THE TIMER
Drill two 6mm holes 97mm vertically apart in the wall.
Insert plastic anchor (supplied) into holes and fit one
No.6screw to top hole leaving a gap under the screw
head of approximately 4.75mm. Place the keyhole slot
over the screw and slide the timer down; if the timer
is loose remove it, tighten the screw and refit the
timer. Continue to do this until the timer fits securely
against the wall. Remove terminal cover “D” by
undoing screw “C”. lnsert the second No.6screw into
slot “B ”and tighten. Your timer is now ready for
wiring.
FIXING THE TIMER
TO THE WALL
Ensure the correct cable cut-outs have been
removed in terminal cover “D” and refit terminal
cover “D ” and tighten screw “C”.
N.B. Ch ck all t rminal scr ws ar tight.
Your Kingshield timer should be wired from a fused
spur. We recommend a PowerBreaker H92 RCD
model.
Switch off th mains and isolat
th supply by r moving th appropriat fus
b for starting th installation.
Prepare cables for connection to the timer, (see
Diagram A).
The maximum size cable that can be used with this
timer is 2.5mm. If flat twin and earth cable is used
the bare earth cable must be fitted with green/yellow
sleeving before fitting the earth terminal.
Fit the bare wire ends into the correct terminals (see
diagram A). You must ensure that there are no loose
strands left out of the terminals.
Firmly tight n all th scr ws.
sing the cable clamps and screws provided and
ensuring the cable clamp is fitted the correct way
round, tightly secure the cable into position.
BC
Red or Brown
Black or Blue
Green or yellow
Diagram A
D
From mains
L = Red or Brown
N = Black or Blue
= Green or Yellow
To appliance
1. Press the R button to reset the timer to its default
settings, activate using a pencil or simular
pointed instrument. (pressing R will delete all
stored programmes)
2. Press Y to enter function setup. (Note: if another
button is not pressed within 10 seconds the
display will revert to the normal screen).
3. se the + or - button to scroll to the clock icon
(flashing) and press Y to enter the current time
setting mode (hours flashing).
4. If you keep the + or - buttons pressed for more
than 3seconds, the display will enter fast scroll
mode.
5. se the + or - button to adjust the hours and
press Y to confirm, minutes will flash.
6. se the + or - button to adjust the minutes and
press Y to confirm, day will flash.
7. se the + or - button to adjust the day and press
N to exit.
CURRENT TIME AND
DAY SETTING
PROGRAMMING THE
SWITCHING TIMES
1. There are 24 ON/OFF programmes available.
2. Press the Y button twice to enter the
programming setting mode.(Note: if another
button is not pressed within 10 seconds the
display will revert to the normal screen).
Please read the instructions fully before attempting
installation.
IMPORTANT
This unit should be installed to current
IEE wiring regulations if in doubt
consult a ualified electrician.
• Timer must not be mounted on a flammable
surface.
• Ensure that the timer does not come into
contact with any combustible materials such as
towels or bedding.
• Ensure at least a 300mm air space is allowed
around the timer.
Issue no: 702576
PLEASE KEEP THESE INSTRUCTIONS
SAFE FOR FUTURE REFERENCE
CE INFORMATION
ACTION TYPE: IB
POLL TION SIT ATION: NORMAL
CLASS 2INS LATION:
:MICRO-DISCONNECTION LIVE
POLE ONLY
3. Default is programme 01 ON, this can be changed
if required by pressing + or - button to scroll
through the 24 ON/OFF programmes as required,
pressing the Y will confirm the programme.
4. Press the Y button to confirm programme 01 ON,
hours will flash.
5. se the + or - button to adjust the hours and
press Y to confirm, minutes will flash.
6. se the + or - button to adjust the minutes and
press Y to confirm, days will flash.
7. Apart from individual days of the week, the
following day combinations of multiple day blocks
can be selected by pressing the + or - buttons.
•Monday to Sunday
• Monday to Friday
• Saturday to Sunday
• Monday to Saturday
• Monday + Wednesday + Friday
• Tuesday + Thursday + Saturday
• Monday + Tuesday + Wednesday
• Thursday + Friday + Saturday
8. Select day or day block as required and press the Y
button to confirm.
9. Press the + button, this will select the programme
01 OFF, press Y to confirm.
10.Follow 4to 7above to set the 01 OFF programme
(day or day block must be the same as
programme ON).
11.If no more programmes are required, press the
N button to exit.
12.If more programmes are required follow step 3.
13.To cancel a programme once set, press and hold
the N button for more than 3seconds when the
desired programme number is flashing i.e. to
cancel programme 01 ON, press the Y button
twice and hold the N button down for more than 3
seconds to delete. Pressing the + button again will
select 01 OFF.
14.Repeat 13 to delete 01 OFF. This procedure can be
repeated to delete any of the 24 programmes.
MANUAL OVERRIDE
SUMMER TIME SETTING
TIMER COUNTDOWN
FUNCTION
1. Timer has a 100 hour countdown feature i.e. the
timer can be set to any period from 1minute to
100 hours and will countdown in the ON state and
turn OFF at the end of the countdown period.
2. Press the Y button then use the + or - button to
select the “down” icon on the right hand side of
the display, press Y again to enter the countdown
mode.
3. se the + or - button to adjust the hours and
press Y to confirm. minutes will flash.
4. se the + or - button to adjust the minutes and
press Y to confirm and complete the countdown
time setting.
5. Press the N button to start the countdown.
6. Output switched to ON during the countdown
period.
7. Press the N button to pause the countdown
(output switched to OFF)
8. To resume countdown simply press the N button
again.
9. Press and hold the N button for more than 3
seconds to exit the countdown function.
1. When in normal clock mode, pressing the N
button will scroll through the following switching
options.
•ALWAYS ON - timer is permanently ON.
• PROG - timer is in programme ON mode,
will switch off at the next programme OFF time.
• ALWAYS OFF - timer is permanently OFF.
• PROG - timer is in programme OFF mode,
will switch on at the next programme ON time.
1. Press the Y button, then use the + or - buttons to
scroll through to “summer” (flashing).
2. Press the Y button again to access the summer
time setting.
3. Press the + or - button to change between
summer on or off.
4. Press Y to confirm summer setting, time will
advance 1hour.
5. A “S MMER” icon will appear in the display.
6. se the same procedure to remove the
“S MMER” icon when reverting to GMT in the
winter.
TECHNICAL DATA
RESET
GUARANTEE
Your KingShield 7Day Electronic Immersion
Heater Timer is guaranteed for 12 months
from the date of purchase.
This does not affect your statutory rights.
READING YOUR
PROGRAMMED TIMES
Pressing the reset button R with a pencil or similar
will reset all programmed times and set time of day
to zero.
1. Press Y button twice to enter programme mode.
2. Press the + or - buttons to scroll through the 24
ON/OFF programmes to check settings.
3. Press the N button to exit and revert to clock
mode.
Connection: See label on unit
Switching Capacity: 16A resistive, 2A Inductive
Ambient Temperature: -10°C to + 55°C
Running Reserve: 150 Hours
Memory location: 24
Shortest switching time: 1minute
WEST ROAD . HARLOW
ESSEX . CM20 2BG . UK
[email protected]
W W W. G R E E N B R O O K . C O . U K

Other manuals for T106-C

1

Other KingShield Timer manuals

KingShield T109-C Manual

KingShield

KingShield T109-C Manual

KingShield T17B-C Manual

KingShield

KingShield T17B-C Manual

KingShield T80-C Manual

KingShield

KingShield T80-C Manual

KingShield T106-C User manual

KingShield

KingShield T106-C User manual

Popular Timer manuals by other brands

Profi Power 2.440.007 manual

Profi Power

Profi Power 2.440.007 manual

Intermatic HB35R supplementary guide

Intermatic

Intermatic HB35R supplementary guide

Woods 50007 instructions

Woods

Woods 50007 instructions

Prime TNID7111 quick start guide

Prime

Prime TNID7111 quick start guide

Intermatic Grasslin Talento Smart LAN operating instructions

Intermatic

Intermatic Grasslin Talento Smart LAN operating instructions

AVK ACMO 879 Series Installation, operation & maintenance manual

AVK

AVK ACMO 879 Series Installation, operation & maintenance manual

Emerson Research SmartSet JMK2442 user manual

Emerson Research

Emerson Research SmartSet JMK2442 user manual

Theben Timeguard NTT05 Installation & operating instructions

Theben

Theben Timeguard NTT05 Installation & operating instructions

Alzatex Timekeeper F Series user manual

Alzatex

Alzatex Timekeeper F Series user manual

HANYOUNG NUX T48A instruction manual

HANYOUNG NUX

HANYOUNG NUX T48A instruction manual

red lion CUB3T4 manual

red lion

red lion CUB3T4 manual

HANYOUNG NUX MA4N-A instruction manual

HANYOUNG NUX

HANYOUNG NUX MA4N-A instruction manual

Green Brook T106A-C Installation & operating instructions

Green Brook

Green Brook T106A-C Installation & operating instructions

HANYOUNG NUX TF4A instruction manual

HANYOUNG NUX

HANYOUNG NUX TF4A instruction manual

nor-tec 37224 instruction manual

nor-tec

nor-tec 37224 instruction manual

Aqua Control ACCESS C1114 manual

Aqua Control

Aqua Control ACCESS C1114 manual

ACU-RITE 00534 instruction manual

ACU-RITE

ACU-RITE 00534 instruction manual

Fantini Cosmi W04C quick start guide

Fantini Cosmi

Fantini Cosmi W04C quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.