KingShield T109-C Manual

Please read the instructions fully before
attempting installation.
IMPORTANT
This unit should be installed to current
IEE wiring regulations if in doubt
consult a ualified electrician.
• Timer must not be mounted on a
flammable surface.
• Ensure that the timer does not come
into contact with any combustible
materials such as towels or bedding.
• Ensure at least a 300mm air space
is allowed around the timer.
INSTALLATION/OPERATING
INSTRUCTIONS FOR
DUAL TARIFF BOOST TIMER
-T109-C
INSTALLATION
THIS TIMER SHOULD NOT BE
FITTED ONTO A CONDUCTIVE
SURFACE (I.E METAL)
NOTE
Use the terminals 1to 5as identified.
1. Before you begin to install.
DISCONNECT THE MAINS SUPPLY
2. The Dual Tariff Boost Timer is suitable
for fixed wiring only.
3. The following cable cross sections are
possible:
4. Select the single or twin box fixing
points on the plate.
5. If the timer is to be surface mounted:
select the single or twin fixing points
on the back plate.
6. ire entry from rear, both sides
possible.
7. Connect main cable as shown in Fig.5.
8. Select desired flexible cable outlet to
immersion heaters and using pliers
remove the selected slot.
9. Clamp cables using attached cable
clamp.
10. Connect the ‘BOOST’ and the
‘TIMED ON’ as required in Fig.6,7
&8.
11. Assemble the timer to the back plate
by aligning the location pins on the
top of the backplate with the cut outs
provided on the clock body. Lock in
position using a fixing screw.
Fig.1
Fig.2
Fig.3
box box
Fig.4
3x2.5mm2
(2X) output
3x4mm2
(2X) output
Fig.5
Fig.6
Two seperate immersion heaters.
Fig.7
Single immersion heaters.
Fig.8
Dual immersion heaters.
This timer controls the use of cheap rate
electricity during the night to heat the
water in your tank for the following
applications:
BOOST LOAD
BOOST LOAD
BOOST LOAD
TIME ON LOAD
TIME ON LOAD
TIME ON LOAD
MAINS
SUPPLY
MAINS
SUPPLY
MAINS
SUPPLY
BOOST
BOOST LOAD
TIME ON LOAD
NEUTRAL
MAINS
SUPPLY
ON/OFF
SWITCH
APPLICATIONS
T109-C Ins June 11:Layout 1 6/9/12 13:35 Page 1
Issue no: 702580
PLEASE KEEP THESE INSTRUCTIONS
SAFE FOR FUTURE REFERENCE
TECHNICAL DATA
GUARANTEE
Your KingShield Dual Tariff Boost Timer
is guaranteed for 12 months from the
date of purchase. This does not affect
your statutory rights.
TIMED ON INDICATOR
The indicator glows when the ‘TIMED
ON’ output is active.
BOOST ACTIVATOR
The indicator glows if the ‘BOOST
S ITCH’ is used.
ON/OFF SWITCH - SWITCH IS IN ‘OFF
POSITION’
The settings of the ‘TIMED ON’and
‘BOOST’ time period are not activated
the clock runs but the heater is
disconnected.
SWITCH IS IN ‘ON POSITION’
The settings of the ‘TIMED ON’ AND
‘BOOST’ time period are activated and
the water will be heated during the
‘TIMED ON’ time period.
BOOST BUTTON
1. This button is only needed if you
need extra hot water during the day
time ‘PEAK’ time.
2. Choose your boost time (adjustable
between 15 &120 minutes). Press
the ‘BOOST BUTTON’ once for
switching ON.
3. If you want to interrupt the boost
function before the boost time is
completed: Press the ‘BOOST
BUTTON’ again.
CHANGING THE ‘TIMED ON’ TIME
PERIOD
To set the time on period, move the
tappets for the ‘TIMED ON’ time period
to the outer position of the dial. The
minimum switching time is 15 minutes.
SETTING THE TIME OF DAY
Turn the dial in the direction of the arrow
(clockwise) until the correct time of day is
exactly opposite the time set marker on
the clockface (24hr clock).
FITTING THE SEE-THROUGH COVER
1. Once the see through cover is
located, it can be removed using a
screwdriver.
2. Align the bar on the edge of the cover
with the groove at the lower end of
the dial in the housing.
3. Remove the cover by applying a
screwdriver between groove and
cover.
Fig.10
Fig.11
Boost
Indicator
Boost
Button
On/Off
Switch
Timed on
Indicator
Clock with
Tappets
HEATER CONTROLLER AT A GLANCE
Fig.9
Rated Voltage: 230V, AC 50Hz
Max Current: 16A resistive, 2A Inductive
Ambient Temp: -10°C to + 55°C
Rating: 16A for immersion
heaters upto 3.5Kw
Boost: Adjustable between 15
and 120 minutes
Fitting: Surface mounted
Dimensions: 86Hx155 x 55D (mm)
Protection Category: IP20
WEST ROAD . HARLOW
ESSEX . CM20 2BG . UK
[email protected]
W W W. G R E E N B R O O K . C O . U K
T109-C Ins June 11:Layout 1 6/9/12 13:35 Page 2

Other KingShield Timer manuals

KingShield T106-C Installation and user guide

KingShield

KingShield T106-C Installation and user guide

KingShield T106-C User manual

KingShield

KingShield T106-C User manual

KingShield T17B-C Manual

KingShield

KingShield T17B-C Manual

KingShield T80-C Manual

KingShield

KingShield T80-C Manual

Popular Timer manuals by other brands

RUSTA 90451254 manual

RUSTA

RUSTA 90451254 manual

Hunter NITETIME PRO 45043 Owner's guide and installation manual

Hunter

Hunter NITETIME PRO 45043 Owner's guide and installation manual

Motorola DSP56602 user manual

Motorola

Motorola DSP56602 user manual

Intermatic DTAV40 Series Installation & operating instructions

Intermatic

Intermatic DTAV40 Series Installation & operating instructions

Intermatic EJ351 Owner's instruction manual

Intermatic

Intermatic EJ351 Owner's instruction manual

Schellenberg 25551 manual

Schellenberg

Schellenberg 25551 manual

Levante LEV24/7PFS Fitting & user instructions

Levante

Levante LEV24/7PFS Fitting & user instructions

LCI LT3500 Handbook

LCI

LCI LT3500 Handbook

Uniteck UNITIMER 16.12 manual

Uniteck

Uniteck UNITIMER 16.12 manual

Prime Wire & Cable TNOLED02 user manual

Prime Wire & Cable

Prime Wire & Cable TNOLED02 user manual

TOOLCRAFT 2384970 operating instructions

TOOLCRAFT

TOOLCRAFT 2384970 operating instructions

Prime TNID7111 quick start guide

Prime

Prime TNID7111 quick start guide

BestTrack Champ Timer Command manual

BestTrack

BestTrack Champ Timer Command manual

Orbit B-hyve quick start guide

Orbit

Orbit B-hyve quick start guide

Smeg KIT TIMER manual

Smeg

Smeg KIT TIMER manual

Theben TR Series Assembly and operating instructions

Theben

Theben TR Series Assembly and operating instructions

Omron H3CR-F - instruction manual

Omron

Omron H3CR-F - instruction manual

F&F AS-214 quick start guide

F&F

F&F AS-214 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.