Technische Daten
Technical Data
RF-TA55P2.01
RF-TA55P4.01
RF-TA55P6.01
RF-TA55P8.01
RF-TA55A2.01
RF-TA55A4.01
RF-TA55A6.01
RF-TA55A8.01
Anzahl Sensorächen
Number of sensor areas 2/4/6/8 2/4/6/8
Anzahl zweifarbige LED
Number of bicolored LED 2/4/6/8 2/4/6/8
Orientierungs LED
Orientation LED 1 1
Sendefrequenz
Transmitter frequency 868,3Mhz (Für den Betrieb in der EU/For operating inside the EU)
Reichweite Freifeld
Range 150m 150m
Ausgangspegel
Output level 10dBm 10dBm
Empndlichkeit
Sensitivity >-105dBm >-105dBm
Anzahl Ausgänge
Number of outputs - 2
Maximale Schaltleistung pro Kanal
Output switching ratings
Ohmsche Last
Ohmic load -- 10A
Kapazitive Last
Capacitive load -- 21uF
Spannung
Voltage -- 230VAC
Mech. Schalthäugkeit
Output life expectancy -- 1.000.000
Max. Kabelquerschnitt
Permitted wire gauge
Anschlußklemmen
Connection terminal 1,5mm² 1,5mm²
Versorgungsspannung
Power Supply 230VAC 230VAC
Leistungsaufnahme typ.
Power Consumption typ. < 0,3W < 0,3W*
Umgebungstemperatur
Operation temperature range 0 bis + 45°C 0 bis + 45°C
Schutzart
Enclosure IP 20 IP 20
Abmessungen (B x H)
Dimensions (W x H) 55mm x 55mm 55mm x 55mm
Technische Daten KNX Taster RF+ - Technical Data KNX Push Button RF+
RF-TA55x8.01 Front Oberteil/Upper part
Allgemeine Sicherheitshinweise - Important safety notes
Lebensgefahr durch elektrischen Strom - Danger High Voltage
Das Gerät darf nur von Elektrofachkräften montiert und angeschlossen werden. Beachten sie die länderspezischen •
Vorschriften sowie die gültigen KNX-Richtlinien. Die Geräte sind für den Betrieb in der EU zugelassen und tragen das CE
Zeichen. Die Verwendung in den USA und Kanada ist nicht gestattet. Installation and commissioning of the device
only be carried out by authorised electricans. The relevant standards, directives, regulations and instructions must be
observed. The devices are approved for use in the EU and have the CE mark. Use in USA and Canada is prohibited.
Betriebsanleitung KNX Taster RF+
nur für autorisiertes Elektrofachpersonal
Operating Instructions KNX Push Button RF+
for authorised electricans
Anschlußklemmen, Bedien- und Anzeigeelemente KNX Taster RF+
Terminals, Operating and Display KNX Push Button RF+
1 - Programmiertaster
- Programming key
2 - Rote Programmier LED
- Red programming LED
3 - Verriegelung Beschriftungsfolie
- Interlock labeling lm
4 - Anschlußklemmen
- Connection terminals
BG-RFPSA Front Unterteil/Base part
BG-RFPSA Back Unterteil/Base part
Alle roten LEDs der Taster dienen
als Programmier LED. Diese blinken im
Wechsel von links nach rechts.
2
All red LEDs of the Push Button are
used as programming LED. They are
blinking alternately from the left to the
right side.
2
4
Wichtiger Einbauhinweis - Important assembly note
- Die Beschriftungsfolie nur mit einem Laserdrucker bedrucken !
- The labeling lm has to be printed with a laser printer !
RF-TA55x.01 Back Oberteil/Upper part
1
- Die Lieferung des Tasters RF+ erfolgt in zwei getrennten Verpackungen. Dem Oberteil RF-TA55xx.01 sowie dem Unterteil BG-RFPSA.
- The Push Button RF+ is delivered in two separate boxes. The Upper part RF-TA55xx.01 and the base part BG-RFPSA.
* Abhängig von der Schaltstellung der Ausgangsrelais. * Depends on the switching position of the output relays.
- Die notwendige Abisolierlänge der verwendeten Kabel beträgt 8mm.
- Insulation of the inserted cable must be removed 8mm.
MDT technologies GmbH •51766 Engelskirchen •Papiermühle 1
Tel.: + 49 - 2263 - 880 •Fax: + 49 - 2263 - 4588 •[email protected] •www.mdt.de
Stand: 1013
Technische Änderungen und Irrtümer vorbehalten,
Abbildungen können abweichen.
Anschlußbeispiel RF-TA55Ax.01 - Schaltbetrieb
Exemplary circuit diagram RF-TA55Ax.01 - switching mode
Beschreibung KNX Taster RF+ - Description KNX Push Button RF+
Der MDT KNX RF+ Funk Taster löst nach Tastendruck abhängig von der Parametrierung KNX/EIB Telegramme aus. Die Tasten sind als
Tastenpaar (zweiächig) oder als Einzeltasten parametrierbar. Neben Dimmer/Jalousie, Kontaktart und Sperrobjekten stehen zahlreiche
Funktionen zur Auswahl. Der MDT KNX RF+ Funk Taster verfügt über 2 integrierte Logikmodule. Das Senden eines zweiten Objektes ist über
die Logikmodule möglich. Der MDT KNX RF+ Funk Taster arbeitet im bidirektionalen KNX RF Systemmode und eignet sich hervorragend
zum Austausch von herkömmlichen Serienschaltern in bestehenden Installationen ohne KNX Buskabel. Die Anbindung an den KNX Bus
erfolgt über den MDT KNX RF+ Funk Linienkoppler. Der eingebaute Aktor kann als 2-fach Schaltaktor oder 1-fach Jalousieaktor parametriert
werden (Nur RF-TA55Ax.01). Das mittige Schriftfeld mit Deckfolie erlaubt die individuelle Beschriftung des Tasters. Die Beschriftungsvorlage
nden Sie auf unserer Webseite im Downloadbereich. Der MDT KNX RF+ Funk Taster verfügt über ein Orientierungslicht und je eine
zweifarbige (Rot/Grün) LED pro Tasten-äche. Diese können mit internen oder externen Objekten angesteuert werden. Es besteht die
Möglichkeit 3 Zustände mit einer LED anzuzeigen z.B.: LED aus = „abwesend“, LED grün = „anwesend“, LED rot = „Fenster auf“.
Der KNX RF+ Taster ist zur Installation in Schalterdosen vorgesehen. Die Montage muss in trockenen Innenräumen erfolgen.
The MDT KNX RF+ Push Button releases KNX telegrams after pushing the buttons on top, 1 or 2 Button operation can be paramerized.
The device provides extensive functions like switching of lighting, operation of blinds and shutters, contact type and block communication
objects for each channel. The MDT KNX RF+ Push Button has 2 integrated logical modules. The sending of an second object is possible by
the logical modules. The MDT KNX RF+ Push Button is operating in bidirectional KNX RF+ system mode and is perfectly suited to replace
conventionel push buttons in existing installations without placing KNX bus cables. The connections to the KNX bus is realized via the MDT
KNX RF+ Line Coupler. The integrated actuator can be set as 2-fold switching actuator or 1-fold shutter actuator (RF-TA55Ax.01 only).
The centered title block allows individually marking of the MDT KNX RF+ Push Button. You can use transparent or the lightgray lm if no
is marking is required. You nd the marking draft in our download area. The MDT KNX RF+ Push Button has an orientation light LED and
a bicolored (Red/Green) LED for the sensor area. These LED can be set from internal or external objects. The LED can display 3 situations
like: LED off 0 „absent“, LED green „present“, LED red „window open“. The MDT KNX RF+ Push Button is a ush mounted device for xed
installations in dry rooms, it is delivered with support ring.
Inbetriebnahme KNX Taster RF+ - Commissioning KNX Push Button RF+
Montage und Anschluß KNX Taster RF+ - Installation KNX Push Button RF+
1. Der Einbau des Tasters (RF-TA55xx.01) erfolgt in einer Schalterdose.
The installation of the Glass Push Button (RF-GTx4x) requires a outlet socket.
2. Verkabeln Sie das Unterteil (BG-RFPSA) laut Zeichnung. Die Schaltkontakte sind durch vorgeschaltete Leitungschutzschalter abzusichern.
Wire up the base part (BG-RFPSA) as descripted in the circuit diagram. The switching contacts must be fused with a circuit breaker.
3. Schrauben Sie das Unterteil (BG-RFPSA) auf die Schalterdose. Beachten Sie die richtige Einbaulage (TOP)
Screw the base part (BG-RFPSA) onto the outlet socket. Mind the correct installation position (TOP)
4. Stecken Sie das Taster Oberteil (RF-TA55xx.01) auf das bereits montierte Unterteil. Beachten Sie die richtige Einbaulage (TOP)
Plug the Push Button upper part (RF-TA55xx.01) onto the already installed base part. Mind the correct installation position (TOP)
5. Netzspannung zuschalten.
Switch up mains power.
Hinweis: Die Produktdatenbank nden Sie unter www.mdt.de/Downloads.html
Note: Before commisioning please download application software at www.mdt.de/Downloads.html
1. Programmierung des KNX RF+ Linienkopplers vor Inbetriebnahme des KNX RF+ Tasters erforderlich.
Programming of the KNX RF+ Line Coupler necessary before commissioning the KNX RF+ Push Button.
2. Physikalische Adresse vergeben und Applikationsprogramm in der ETS3/4/5 erstellen.
Assign the physical address and set parameters with the ETS3/4/5.
3. Physikalische Adresse vergeben und Applikationsprogramm in der ETS3/4/5 erstellen.
Assign the physical address and set parameters with the ETS3/4/5.
4. Laden Sie die Physikalische Adresse und das Applikationsprogramm in den KNX Taster.
Drücken Sie den Programmiertaster wenn Sie dazu aufgefordert werden.
Upload the physical address and parameters into the KNX Push Button.
After request press programming button.
5. Die roten LEDs erlöschen nach erfolgreicher Programmierung.
After sucessfull programming the red LEDs turn off.
Anschlußbeispiel RF-TA55Ax.01 - Jalousiebetrieb
Exemplary circuit diagram RF-TA55Ax.01 - shutter mode
Einbaulage unbedingt beachten (TOP)
Mind the correct installation position (TOP)
!
Wichtiger Einbauhinweis - Important assembly note

This manual suits for next models

8

Other KNX Controllers manuals

KNX Iddero Verso User manual

KNX

KNX Iddero Verso User manual

KNX GIRA Standard User manual

KNX

KNX GIRA Standard User manual

KNX GIRA User manual

KNX

KNX GIRA User manual

KNX GIRA 2015 00 User manual

KNX

KNX GIRA 2015 00 User manual

KNX SATION-DM0101.0210 User manual

KNX

KNX SATION-DM0101.0210 User manual

KNX Jung 230011SU User manual

KNX

KNX Jung 230011SU User manual

KNX GIRA 5065 00 User manual

KNX

KNX GIRA 5065 00 User manual

KNX GIRA User manual

KNX

KNX GIRA User manual

KNX Berker 7531 40 18 User manual

KNX

KNX Berker 7531 40 18 User manual

KNX Module SAS-04.16 User manual

KNX

KNX Module SAS-04.16 User manual

KNX GIRA User manual

KNX

KNX GIRA User manual

KNX Jung 2304.16 REG HE User manual

KNX

KNX Jung 2304.16 REG HE User manual

Popular Controllers manuals by other brands

EAS Electric ECRL10B instruction manual

EAS Electric

EAS Electric ECRL10B instruction manual

Maintronic Casambi CBA UP manual

Maintronic

Maintronic Casambi CBA UP manual

SamplexPower MSK-20A owner's manual

SamplexPower

SamplexPower MSK-20A owner's manual

Nastec VASCO operating manual

Nastec

Nastec VASCO operating manual

Honeywell CENTRALINE EAGLE user guide

Honeywell

Honeywell CENTRALINE EAGLE user guide

DeVilbiss HARG-510 Service manual

DeVilbiss

DeVilbiss HARG-510 Service manual

ADC GSM Base Station Controller UltraWAVE BSC Specification sheet

ADC

ADC GSM Base Station Controller UltraWAVE BSC Specification sheet

Eurotherm 808 Installation and operation manual

Eurotherm

Eurotherm 808 Installation and operation manual

Vivitek LauncherPlus WQL-400 user manual

Vivitek

Vivitek LauncherPlus WQL-400 user manual

Aeotec WallMote user guide

Aeotec

Aeotec WallMote user guide

Festo CMMP-AS-***-M3 Series Description

Festo

Festo CMMP-AS-***-M3 Series Description

Plum Cieplo ecoMAX850P2-C manual

Plum

Plum Cieplo ecoMAX850P2-C manual

Festo ELGC-TB Series operating instructions

Festo

Festo ELGC-TB Series operating instructions

Reya BATVIEW 2 Operating and users manual

Reya

Reya BATVIEW 2 Operating and users manual

Aqua Lung MISTRAL SECOND STAGE Technical maintenance manual

Aqua Lung

Aqua Lung MISTRAL SECOND STAGE Technical maintenance manual

ICP DAS USA ISaGRAF PAC Series Getting started

ICP DAS USA

ICP DAS USA ISaGRAF PAC Series Getting started

ABB CBXi Series user guide

ABB

ABB CBXi Series user guide

Axis A1001 installation guide

Axis

Axis A1001 installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.