8
Alternate
SLAVEMASTER MASTER SLAVE
Further control facilities
*RandomAccess
You select slides in 2 projector dissolve
ac- cording to the slide number of
your presentation and not ac-
cordingto the slidetray number
(see table on p. 34)!
Of course, if the slide you
are looking for is in the
slide tray of the projector
which is currently projecting a slide, a
dissolve is not possible. The slide will
first be faded down and the new slide
fadedup. Inthiscase, thescreen willstay
blank during the transport period.
However, if the slide you are looking for
is in the slide tray of the projector which
is currently dark, it will dissolve with
the slide you are currently projecting.
Zerocompartment
Ifthere isaslide inthe zerocompartment
of the slide tray, this can be selected by
entering the following:
161 for the MASTER projector;
0 for the SLAVE projector.
Note: it is not possible to dissolve from
0 to 161 or vice versa.
Note (EKTAPRO 7010 and 9010)
If the slide tray (SLAVE) is transported
on after a random access by pressing the
transport buttons on the projector once
or more, the previously selected slide
cannot be accessed with a repeated ran-
domaccesscommand.(Example:onslide
36 with RA, transport forwards to slide
38, then back to slide 36 with RA cannot
be done.)
With the commands "Fade MASTER",
"Fade SLAVE" and "Alternate" you can
carry out dissolves without a slide trans-
port afterwards. When a dissolve com-
mand follows this will be carried out via
forward transport key on the next slide
and with the backward transport key on
the previous slide. Therefore it is guaran-
teed, that the synchroniicity will also be
maintained by individual lamp status. The
fade in and out time will be that of the
dissolve time last set.
Withthese commandsyou alsocan change
the lamp status of the projectors when
operated in the parallel mode (code 970)
or in the individual control mode (code
980), whereby the new lamp status will be
keptbyfurthertransportor softslidechang-
es. This opens up interesting possiblities
for your presentation.
FFADE MASTER (770)
The MASTER projector's lamp can be
faded in or faded out according to status.
By re-pressing the button the command
will be reversed.
Press <770> and <*> on your remote
control.
FFADE SLAVE (707)
The SLAVE projector's lamp can be faded
in or faded out according to status. By
repressingthe button the command willbe
reversed.
Press <707> <*> on your remote
control.
F* ALTERNATE (Dissolve without
transport) (777)
With the Alternate command the existing
lamp status can be changed (see chart).
Press <777> and <*> on your remote
control.
F*FREEZE(789)
Withthe Freezecommanda soft dissolve
can be stopped at any time (resp. fade in
and fade out by single projection) and in
anyposition. The dissolvecan becontin-
ued by pressing the forward transport
key. With the backwards transport key
you can fade back accordingly.
Press <789> and <*> on your remote
control.
Note:Modeswitch-overs cannot bedone
in FREEZE. FREEZE can only be re-
leased by pressing the standby button or
the transport buttons. If you release
FREEZE by pressing the standby button,
giving the standby command again will
not return to FREEZE but will continue
the dissolve.
With Soft Slide Change the lamp lights
up when FREEZE is ended by pressing
the transport forwards button, and goes
dark if the transport backwards button is
pressed.No slide transportis carriedout.
Special feature: You can use the trans-
port buttons during the dissolve proce-
dure to change the direction of dissolve
morethan once.Once thedissolve proce-
dure has finished, however, the slide is
not transported. This only happens the
next time you press the transport button.
Pressing it again continues your presen-
tation as normal.
Further presentation
features
FINDIVIDUALSLIDETRANSPORT
OFTHE TWO PROJECTORS WITH
REMOTECONTROL(980)
Withthenumbercombination<980>and
<*> you can control the transport of the
two projectors individually with the re-
mote control.
If this code is transmitted, the dissolve
mode is cancelled and the lamps of both
projectors remain on. Soft slide change
cannot be carried out in this mode.
Press <980> and <*> on your remote
control.