manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Komshine
  6. •
  7. Measuring Instrument
  8. •
  9. Komshine KLS-35 User manual

Komshine KLS-35 User manual

nm
1310
HZ
270
nm
1310
HZ
270
nm
1310
HZ
270
nm
1310
HZ
270
KLS-35 stable light source instruction manual
1
3
9
8
4
5
6
12
11
10
7
2
1 3
4
5
2
1310nm
1550nm
HZ
270 HZ
1000
HZ
2000
nm
1310
HZ
270
CW
CW
External and key function description
OLS interface: laser light source output port
1
LED lighting: flashlight illumination
2
Display: display test results and other information
3
Enter key: switch between 7 different output wavelength tests.
4
LED key: turn on/off the flashlight, press any key to backlight
5
key: switchable carrier frequency 270Hz/ 1kHz/ 2kHz
6
On/off key: turn on or off the device
7
automatic shutdown
9frequency
10
power supply battery
8
unit
11 wavelength
12
CW
Power-on and power-saving function
settings
The equipment will turn on
after pressing the " " key. Press
this button again for more than
two seconds to shut down.
This instrument has power
saving function, normal there is no
operation for about ten minutes
after booting, The device will
automatically shut down. If you need
a screen Shield this function to keep
the equipment working all the time
Status, just short press "on" when
booting Key, "Auto-off" at the bottom
left of the meter display. Disappearing
means that the power saving function
is cancelled.
Backlight control
In the power-on state, the
backlight will automatically turn off
after a period of time. After turning
off, press any key to activate the
backlight. The backlight is used to
illuminate the instrument display at
night or in dark places.
Wavelength selection
According to the needs of the
project, select the corresponding
wavelength to match the optical power
meter. After the meter is turned on,
press the "output wavelength" key, the
output wavelength and length will be
switched to the corresponding wave-
length in turn, and will be displayed on
the display. The laser light source of this
series can provide 1310nm and 1550nm
dual-wavelength laser output according
to demand.
Carrier output
In the actual project, it is necessary to
load the audio carrier in the optical signal
to identify the optical fiber. The equip-
ment contains three carrier frequencies,
which are 270Hz, 1KHZ, and 2KHz. After
pressing the "modulated carrier" key, the
equipment will load different carriers in
sequence, and the display will be
displayed at the same time. The current
carrier frequency will be displayed on the
screen.
nm
1310
HZ
270
KLS-35 stable light source instruction manual
Products introduction
7
Products features
8
6
PON wavelength 1310nm/1490nm/1550nm
Automatic shutdown in 10 minutes
SC FC
9
10
Wavelength(nm)
Output Power ≥-5dB
Optical connector SC&FC+2.5mmuniversal(1.25mm LCoptional)
Power supply Alkaline batteries(3 AA 1.5V batteries))
Stable output ±0.05dB/15mins; ±0.1dB/ 8小时
Modulation frequency CW, 270Hz, 1KHz, 2KHz
volume and weight
Please read all instructions and warnings before
using this product. Irregular use will cause
It will damage the product or personal safety.
1310+1550nm(MS)
850+1300nm(MM)
850+1300+1310+1550nm(MS&MM)
1310+1490+1550nm(PON)
183*83*42mm/287g
Silica gel shell protection design, 2m anti-fall
Output power ≥-5dB
2.5mm universal interface + SC&PC adapter
LED function description
Press the "illumination"
button to turn on the LED
lighting, which is convenient
for construction and operation
in a dark environment.
Interface
accessories
Operating environment altitude:
areas below 2000m above sea level
Use environment
Tips
Contact us:
KOMSHINE TECHNOLOGIES LIMITED
Tel : +86 17366186481
Email : [email protected]
Add: 2F Bldg. D Qinheng Tech. Pk. Nanjing,
JS, 210001, China.
Website :www.KomShine.com
1) Do not store this product in high temperature, strong light
and strong magnetic field environment, do not put it pace in
other harsh environments such as fire sources.
2)Improper use of the product may easily cause the product
itself or may endanger personal property Safety.
3)If the consumer violates the product manual and improper
use, the personal and financial Property damages will bear all
consequences, and the company will not bear any legal
responsibility.
4)Non-professionals are strictly forbidden to decompose
this product.
5)Avoid using electrical appliances or loads that exceed the
output current of this product (the circuit will protect
Protection, no output).
6)Avoid strong physical effects, including knocking, throwing,
trampling, squeezing, etc.
Packing carton, stable light source,
certificate, instruction manual
Standard kit
Products specification
The KLS-35 fiber optic light source is characterized by
stable output optical power, wavelength and spectral width with
a small range of stable changes. Provide single-mode fiber
measurement (1310nm/1550nm) dual-wavelength laser output
and multi-mode fiber measurement (850nm/1300nm)
dual-wavelength laser output, and can also provide single and
multi mode (850nm/1300nm/1310nm/1550nm) four-wavelength
laser output And (1310nm/1490nm/1550nm) three-wavelength
laser output. Mainly used for FTTX network and fiber optic
testing. When combined with Optical power meter, it is used to
measure optical power and end-to-end optical loss.

Other Komshine Measuring Instrument manuals

Komshine QX45 User manual

Komshine

Komshine QX45 User manual

Komshine KPM-25m User manual

Komshine

Komshine KPM-25m User manual

Komshine KPN-35 PON User manual

Komshine

Komshine KPN-35 PON User manual

Komshine QX55 Series User manual

Komshine

Komshine QX55 Series User manual

Komshine OTDR QX50 User manual

Komshine

Komshine OTDR QX50 User manual

Komshine KIP-600V User manual

Komshine

Komshine KIP-600V User manual

Komshine KLS-25m User manual

Komshine

Komshine KLS-25m User manual

Komshine KPM-11M User manual

Komshine

Komshine KPM-11M User manual

Komshine KPV-53 User manual

Komshine

Komshine KPV-53 User manual

Komshine KPM-35m User manual

Komshine

Komshine KPM-35m User manual

Komshine KPM-35 User manual

Komshine

Komshine KPM-35 User manual

Komshine KLS-35m User manual

Komshine

Komshine KLS-35m User manual

Komshine KLS-35 User manual

Komshine

Komshine KLS-35 User manual

Komshine KFL-11M User manual

Komshine

Komshine KFL-11M User manual

Komshine KFI-40 User manual

Komshine

Komshine KFI-40 User manual

Popular Measuring Instrument manuals by other brands

Cerlic CBX manual

Cerlic

Cerlic CBX manual

OHAUS 7000 Series Service manual

OHAUS

OHAUS 7000 Series Service manual

GANN HYDROMETTE BL LG 17 operating manual

GANN

GANN HYDROMETTE BL LG 17 operating manual

PCB Piezotronics 3503A1120KG Installation and operating manual

PCB Piezotronics

PCB Piezotronics 3503A1120KG Installation and operating manual

Sensitech TempTale GEO Eagle Instructions for use

Sensitech

Sensitech TempTale GEO Eagle Instructions for use

Simpson Falcon F35 Series manual

Simpson

Simpson Falcon F35 Series manual

Fluke VT Plus HF Operator's manual

Fluke

Fluke VT Plus HF Operator's manual

Instantel Blastmate III Operator's manual

Instantel

Instantel Blastmate III Operator's manual

Siemens 7LQ3 353 manual

Siemens

Siemens 7LQ3 353 manual

Triax MCT059 user manual

Triax

Triax MCT059 user manual

Schmidt FS1-422 instruction manual

Schmidt

Schmidt FS1-422 instruction manual

VetScan i-STAT 1 Operator's manual

VetScan

VetScan i-STAT 1 Operator's manual

Seametrics FT400 General information

Seametrics

Seametrics FT400 General information

T.I.S. MFT-ECO user manual

T.I.S.

T.I.S. MFT-ECO user manual

OrienTek T11P Instructions for use

OrienTek

OrienTek T11P Instructions for use

Netio PowerDIN 4PZ manual

Netio

Netio PowerDIN 4PZ manual

Sensit HXG-3 Quick start instructions

Sensit

Sensit HXG-3 Quick start instructions

frako EM-PQ 2500 operating manual

frako

frako EM-PQ 2500 operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.