KPN-35 PON Optical Power Meter User Manual
1
4
3
5
6
10
13
8
7
11
2
External and key function description
1 3
4
5
2
The meter will turn on after pressing the
" " key,press this key again for more than two
seconds to turn off the instrument.
9
12
Long press OK to enter the
calibration page,after calibration,
press OK to save.
Calibration
Set threshold
View threshold range
Clear threshold
Long press the TH key to enter the
threshold page,threshold setting from
large value to small value.
Press the P/F key to enter the threshold
interface, if the value more than the value
set before,it will be showed in green,means
pass, if it is close to the value set,then showing
in yellow,means warning,if less than the set
value,it will be displayed in red,means failure.
In the shutdown state, first press the
TH button and then press the power button,
Clear the modified threshold and return to
the original factory setting valve.
TH
+
ONT port
1
OLT port
2
Auto shutdown icon
3
Wavelength
4
Power supply battery
5P/F key to enter
threshold page
6Long press OK button to enter the
calibration page and confirm button
7
REF/dB key
Shut down button
Numerical value
8
12
TFT HD LCD display
13
11
Data saving/ Right arrow key in
the state of adjusting the threshold
10
Long press the TH key to enter
the threshold page
9
TH
+
KPN-35 PON Optical Power Meter User Manual
7
8
6Products Specification
9
Data preservation
Products introduction
Products features
Save the current test data:
Long press this button on the test page
to save the current test data, tap to view
stored data.
Clear saved data:
In the shutdown state, first press the
right arrow key and then press the
power button to clear data records.
PON
Measuring wavelength
Sensor type
Linearity
Isolation
With filtering function
1490nm wavelength >40dB 1310nm wavelength >40dB 1310nm wavelength >40dB
1550nm wavelength >30dB
Less than 1.5dB
1260~1360 1480~1500
1310nm 1490nm 1550nm
InGaAS
1539~1565
-40dBm~+16dBm -50dBm~+16dBm
0.01dB
-50dBm~+23dBm
10 groups are set by the host computer
1310nm/1490nm/1550nm
-10℃~+50℃
0%~95%RH
SC/UPC(Other connectors are optional)
3 AA batteries
900 sets
1490nm wavelength >30dB
1550nm wavelength >40dB
Measuring range
Power supply
Connector type
Relative humidity
Working temperature
Data storage
Calibration wavelength
Threshold setting
Display resolution
Inherent uncertainty
Measurable optical
frequency broadband
Insertion loss in
penetration mode(dB)
KPN-35, USB cable, quick guide.
This PON power meter adopts a TFT high-definition
LCD display,it is designed for OLT equipment which is
foucs on online testing, it is very suitable for FTTx/
PON service adjustment or maintenance usage. It can
test and measure signal power for voice, data and
video connections. Allows you to quickly evaluate the
power level of the network, the USB port can transmit
data quickly,up to 1,000 measurement items can be
saved at one time, it is an indispensable tool for
construction and maintenance in the PON system, the
silicone protective cover can prevent accidental falls
drop or other damage.
● The meter test threshold can be set through the
management software.
● Automatic shutdown (can be cancelled).
● Users can test 1490nm, 1550nm in PON network.
at the same time,1310nm three wavelengths.
● Simultaneously measure and display different PON
architectures, data and video signals.
● The instrument provides 5 sets of thresholds to choose
from, with pass, warning, and fail modes.
● Manual calibration.
Tips
10
Operating environment altitude:
areas below 2000m above sea level
Please read all instructions and warnings before
using this product. Irregular use will cause.It will
damage the product or personal safety.
Use environment
1) Do not store this product in high temperature, strong light
and strong magnetic field environment, do not put it pace in
other harsh environments such as fire sources.
2)Improper use of the product may easily cause the product
itself or may endanger personal property Safety.
3)If the consumer violates the product manual and improper
use, the personal and financial Property damages will bear all
consequences, and the company will not bear any legal
responsibility.
4)Non-professionals are strictly forbidden to decompose
this product.
5)Avoid using electrical appliances or loads that exceed the
output current of this product (the circuit will protect
Protection, no output).
6)Avoid strong physical effects, including knocking, throwing,
trampling, squeezing, etc.
Standard configuration
Model
0.5dBm 1nW@1550nm
0.2dB@1550nm≥-40dBm
Contact us:
KOMSHINE TECHNOLOGIES LIMITED
Tel : +86 25 66047688
Email : [email protected]
Add: 2F Bldg. D Qinheng Tech. Pk. Nanjing,
JS, 210001, China.
Website :www.KomShine.com

Other Komshine Measuring Instrument manuals

Komshine KLS-35 User manual

Komshine

Komshine KLS-35 User manual

Komshine KPM-25m User manual

Komshine

Komshine KPM-25m User manual

Komshine OTDR QX50 User manual

Komshine

Komshine OTDR QX50 User manual

Komshine KLS-35m User manual

Komshine

Komshine KLS-35m User manual

Komshine QX45 User manual

Komshine

Komshine QX45 User manual

Komshine KIP-600V User manual

Komshine

Komshine KIP-600V User manual

Komshine KPM-11M User manual

Komshine

Komshine KPM-11M User manual

Komshine KPV-53 User manual

Komshine

Komshine KPV-53 User manual

Komshine KPM-35m User manual

Komshine

Komshine KPM-35m User manual

Komshine KPM-35 User manual

Komshine

Komshine KPM-35 User manual

Komshine KLS-35 User manual

Komshine

Komshine KLS-35 User manual

Komshine KFI-40 User manual

Komshine

Komshine KFI-40 User manual

Komshine KFL-11M User manual

Komshine

Komshine KFL-11M User manual

Komshine KLS-25m User manual

Komshine

Komshine KLS-25m User manual

Komshine QX55 Series User manual

Komshine

Komshine QX55 Series User manual

Popular Measuring Instrument manuals by other brands

X-Rite 891 Operation manual

X-Rite

X-Rite 891 Operation manual

Sequoia LISST-200X user manual

Sequoia

Sequoia LISST-200X user manual

Endress+Hauser Liquiline Control CDC90 operating instructions

Endress+Hauser

Endress+Hauser Liquiline Control CDC90 operating instructions

KPS KPS-PA20 MINI instruction manual

KPS

KPS KPS-PA20 MINI instruction manual

Velleman PCSU1000 Software installation

Velleman

Velleman PCSU1000 Software installation

Emerson 6888i instruction manual

Emerson

Emerson 6888i instruction manual

Dilog DL6780 Combi Volt 1 instruction manual

Dilog

Dilog DL6780 Combi Volt 1 instruction manual

janitza UMG 508 operating manual

janitza

janitza UMG 508 operating manual

Sekonic FLASH MASTER L-358 quick guide

Sekonic

Sekonic FLASH MASTER L-358 quick guide

Primes Cube L Original instructions

Primes

Primes Cube L Original instructions

JENCO VisionPlus 6177 Operation manual

JENCO

JENCO VisionPlus 6177 Operation manual

ENDEAVOUR ET2044 instruction manual

ENDEAVOUR

ENDEAVOUR ET2044 instruction manual

Fidelity Electronics 19e Operation manual

Fidelity Electronics

Fidelity Electronics 19e Operation manual

REED ST-805 instruction manual

REED

REED ST-805 instruction manual

Yoda MR-2000E operating manual

Yoda

Yoda MR-2000E operating manual

HP 82324 Installing

HP

HP 82324 Installing

TESTO 335 instruction manual

TESTO

TESTO 335 instruction manual

SICK GMS815P-PS-3G Supplementary operating instructions

SICK

SICK GMS815P-PS-3G Supplementary operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.