Kramer RC-62 User manual

Kramer Electronics, Ltd.
USER MANUAL
Room Controller Models:
RC-62 Series (RC-62, RC-62P, RC-62L)
RC-63A Series (RC-63A, RC-63AL, RC-63AP)
RC-63D Series (RC-63D, RC-63DL, RC-63DP)

Contents
i
Contents
1
Introduction 1
2
Getting Started 2
3
Overview 3
4
Installing the Room Controller 4
4.1
Defining the RC-62, RC-62P and RC-62L 4
4.2
Defining the RC-63A, RC-63AL and RC-63AP 6
4.3
Defining the RC-63D, RC-63DP and RC-63DL 8
5
Using Your Room Controller 10
5.1
Operating the Room Controller 13
5.2
Using the Macro Buttons 13
6
Customizing the Controllers' Buttons and Labels 14
6.1
Button Labels 14
6.2
Panel Labels 15
7
Technical Specifications 16
Figures
Figure 1: RC-62 Room Controller Front Panel 4
Figure 2: RC-62 Room Controller Rear Panel 5
Figure 3: RC-63D Room Controller Front Panel 8
Figure 4: RC-63D Room Controller Rear Panel 9
Figure 5: RC-63D Standalone Power Supply Pinout 10
Figure 6: Example of a Typical RC-63DL Configuration 11
Figure 7: RC-63D connected to the SV-551 SummitView™ Processor / Switcher 12
Figure 8: RC-63DL Labels Setup 13
Figure 9: Sample “Button Labels” Sheet 14
Figure 10: Sample “Panel Labels" Sheet 15
Tables
Table 1: Defining the Room Controllers' Series 1
Table 2: RC-62 Front Panel Features 5
Table 3: RC-62 Rear Panel Features 5
Table 4: Defining the RC-63, RC-63AL and RC-63AP 7
Table 5: RC-63D Front Panel Features 9
Table 6: RC-63D Rear Panel Features 9
Table 7: Connection Scheme (for the example in Figure 6) 11
Table 8: The Commands Configuration 13
Table 9: Technical Specifications of the Room Controller Series 16

Introduction
1
1 Introduction
Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been
providing a world of unique, creative, and affordable solutions to the vast range of
problems that confront the video, audio, presentation, and broadcasting
professional on a daily basis. In recent years, we have redesigned and upgraded
most of our line, making the best even better! Our 1,000-plus different models
now appear in 11 groups
1
that are clearly defined by function.
Congratulations on purchasing your Kramer RC-62 and/or RC-63A and/or
RC-63D room controller (defined in Table 1), which are available in European
and American versions.
Table 1: Defining the Room Controllers' Series
2
LCD Labels Printed Labels Plastic Caps
Has LCD labels,
letting you
program the
required group
label, as well as
rolling text on
the display
The DISPLAY
and SOURCES
labels are
printed on the
unit
Has backlit
plastic caps to
which you can
insert a label
from a set of
supplied stickers
RC-62 Series RC-62L RC-62 RC-62P
RC-63A series
With a separate analog
volume control adjustment
knob
RC-63AL
RC-63A
RC-63AP
RC-63D Series
With a separate digital
volume control adjustment
knob
RC-63DL
RC-63D
RC-63DP
1 GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Matrix Switchers; GROUP 3: Control Systems; GROUP 4:
Format/Standards Converters; GROUP 5: Twisted-Pair Solutions; GROUP 6: Specialty AV Products; GROUP 7: Scan
Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9: Room Connectivity; GROUP 10: Accessories and
Rack Adapters; GROUP 11: Sierra Products
2 The specific model is not printed on the unit. For example, RC-63DL (with LCD labels) has RC-63D printed on it and can
be recognized by the LCD displays on its panel

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Getting Started
2
The Room Controllers are designed to let you control an A/V system with ease—
such as our SummitView™ kits
1
—in a multimedia classroom or conference room.
The RC-63DL is provided by default with both SummitView™ kits.
The room controllers—RC-62,RC-63A and RC-63D—can be used as:
System controllers for the SummitView™ system when connected via
K-NET
2
cable to the SV-551 SummitView™ Processor / Switcher. When
used in this way, no programming of these units is needed and the unit does
not require a separate power supply
Advanced, standalone, wall-mounted room controllers. When used in this
way, programming of these units is required
3
as well as a separate power
supply
The package includes the following items:
Any version of the RC-62 series, the RC-63A series or the RC-63D series
3' (0.91m) USB cable
4
Screwdriver
This user manual
5
RC-SV configuration software
2 Getting Started
This user manual is written for the end user. Refer to the separate
RC-SV Configuration Guide (available online) for details of how to install and
configure the Room Controller
6
We recommend that you review the contents of this user manual.
1 SummitView™ is a complete and simple solution for the integration of media and control in classrooms, training rooms and
presentation rooms. SummitView™ is as easy-to-use as it is to specify and install. Everything required, including wall plate
interfaces, controllers, amplifiers, speakers, cable and even enclosures ready to be mounted to projection mounts is included.
With SummitView™ you get everything you need for a high end integrated media system – just add the displays and sources.
All the signals are transmitted over economical CAT 5 cable
2 K-NET is a proprietary Kramer protocol for interconnecting Kramer units
3 Refer to the separate online “RC-SV Configuration Guide” at http://www.kramerelectronics.com
4 Part number C-UA/MUB-3
5 Download up-to-date Kramer user manuals from the Internet at this URL: http://www.kramerelectronics.com
6 That provides information about how to set up the system. This online guide may well be updated on a regular basis. For the
latest online guide, go to http://www.kramerelectronics.com

Overview
3
3 Overview
This user manual describes the RC-62 / RC-63A / RC-63D series. Each of these
highly versatile controller interfaces acts as an all-in-one extended remote control
panel for control of A/V equipment—especially projectors and associated
equipment—in any room (such as classrooms, boardrooms, or auditoriums). They
streamline operations and simplify control by integrating audio, video, and
computer-video sources into a centralized system. Each room controller includes:
Configurable backlit
1
buttons to set up any supported
2
command
A bidirectional RS-232 wired serial port, for universal display (for example,
projectors) and switcher control
Two K-NET ports
Two relays for the simplified and centralized control of room functions (such
as lighting, closing blinds, screen settings, and so on)
An IR control port
An IR-learner for the customized control of external sources, receiving the IR
commands from different remote transmitters without the need for an external
IR remote control unit
Macro mode operation, for programming multiple commands with the press
of a single button
Support for firmware upgrade via USB (using K-NET connection when used
together with the SV-551. For further details, see our Web site)
In addition, the RC-63A and the RC-63D feature a separate analog and digital
volume adjustment knob, respectively.
To achieve the best performance:
Connect only good quality connection cables, thus avoiding interference,
deterioration in signal quality due to poor matching, and elevated noise-levels
(often associated with low quality cables)
Avoid interference from neighboring electrical appliances and position your
Kramer Room Controller away from moisture, excessive sunlight and dust
Caution – No operator-serviceable parts inside unit.
Warning – Use only the Kramer Electronics input power
wall adapter that is provided with this unit
1
.
Warning – Disconnect power and unplug unit from wall
before installing or removing device or servicing unit.
1 256 colors are available for backlit buttons (to be configured by the system integrator)
2 To be configured by the system integrator only

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Installing the Room Controller
4
4 Installing the Room Controller
This section defines the:
RC-62, RC-62P, and RC-62L, see section 4.1
RC-63A, RC-63AL and RC-63AP, see section 4.2
RC-63D, RC-63DL, RC-63DP, see section 4.3
4.1 Defining the RC-62, RC-62P and RC-62L
The RC-62 is available as a 1 Gang wall plate (for the USA) or a 2 Gang wall
plate (for Europe). It features 6 front panel buttons designed in two groups; one
group of 2 buttons, and another group of 4 buttons. Each group can be
programmed according to the user's requirements. LCD and plastic cap variations
are available as well as printed graphics. The:
RC-62 has the DISPLAY and SOURCES labels printed on the unit
RC-62P has a backlit plastic cap to which you can insert a label from a set of
supplied stickers (see section 6)
RC-62L has an LCD label, letting you program the required group label
The RC-62 series includes two relays for the simplified and centralized control of
room functions (such as lighting, closing blinds, screen settings, and so on), an IR
output, a bi-directional RS-232 port, and two K-NET ports. In addition, the
RC-62 features an IR-learner for the customized control of external sources,
memorizing the IR commands from different remote transmitters. A USB port is
included for programming the RC-62 via a computer.
Figure 1, Figure 2, Table 2 and Table 3 define the RC-62, RC-62P, and RC-62L.
Version for Europe
Version for the USA
Figure 1: RC-62 Room Controller Front Panel
2
1 For example: model number AD2512C, part number 2535-000251
2 The USA version shown has plastic cap labels (RC-62P), and the European version shown has printed labels (RC-62)

Installing the Room Controller
5
Table 2: RC-62 Front Panel Features
# Feature Function
1 “DISPLAY” and
“SOURCE” Labels
RC-62 - "DISPLAY" and “SOURCE” are printed on the panel
RC-62P - backlit plastic cap to affix your own labels (see Figure 10)
RC-62L - an LCD version on a blue background that displays up to 8
characters at once (programmed via the USB port) and includes rolling text
2 DISPLAY Buttons These 2 configurable backlit buttons can set up any supported command
1
3 SOURCE Buttons These 4 configurable backlit buttons can set up any supported command
1
Version for Europe
Version for the USA
Figure 2: RC-62 Room Controller Rear Panel
Table 3: RC-62 Rear Panel Features
# Feature Function
1 FIRMWARE UPGRADE
Switch For technical support use only
2 Grounding Screw Connect to grounding wire (optional)
3 K-NET TERM Switch For line termination
4 PROGRAM (USB)
Connector Connect to a computer for unit configuration
5 IR IN Receiver Receives IR remote commands
6 RELAYS Connections Connect to room items (such as lighting, screen settings, blinds, and so on)
7 IR Connections Control a machine via an IR Emitter
8 RS-232 Connections Connect to the RS-232 connector on the A/V equipment or a PC or other Serial
Controller
9 K-NET 2 Connections
10 K-NET 1 (K-NET)
Connections
On K-NET 1 (K-NET) and K-NET 2, PIN GND is for the Ground
connection
2
; PIN B (-) and PIN A (+) are for RS-485, and PIN +12V is for
powering the unit
11 FACTORY RESET
Button Press to revert to the default settings, including all the configured buttons
1 By the system integrator only
2 The ground connection is sometimes connected to the shield of the RS-485 cable (in most applications, it is not connected)

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Installing the Room Controller
6
4.2 Defining the RC-63A, RC-63AL and RC-63AP
The Kramer RC-63A is available as a 2 Gang wall plate. It features 6 front panel
buttons designed in two groups; one group of 2 buttons, and another group of 4
buttons. Each group can be programmed according to the user's requirements.
LCD and plastic cap variations are available:
RC-63A has the DISPLAY and SOURCES labels printed on the unit
RC-63AP has a backlit plastic cap to which you can insert a label from a set
of supplied stickers
RC-63AL has an LCD label, letting you program the required group label, as
well as rolling text on the display
The RC-63A also includes:
An analog volume control adjustment knob
Two relays for the simplified and centralized control of room functions (such
as lighting, closing blinds, screen settings, and so on)
An IR output, a bi-directional RS-232 port, and two K-NET ports
An IR-learner for the customized control of external sources, memorizing the
IR commands from different remote transmitters
A USB port is included for programming the RC-63A via a computer.
Table 4 defines the RC-63 RC-63AL and RC-63AP.

Installing the Room Controller
7
Table 4: Defining the RC-63, RC-63AL and RC-63AP
1
# Feature Function
1 SOURCE
Buttons These 4 configurable
backlit buttons can set up
any supported command
2
2 “DISPLAY”
and
“SOURCE”
Labels
RC-63A - "DISPLAY" and
“SOURCE” are printed on
the panel
RC-63AP - backlit plastic
cap to affix your own
labels (see Figure 10)
RC-63AL - an LCD
version on a blue
background that displays
up to 8 characters at once
(programmed via the USB
port) and includes rolling
text
3 DISPLAY
Buttons These 2 configurable
backlit buttons can set up
any supported command
2
4 VOLUME
Knob Rotate clockwise to
increase the level
#
Feature Function
1 GND Connection Ground connection for the
potentiometer
2 LEVEL
Connection Wiper of potentiometer
3 +V PIN +V connection for the
potentiometer
4 PROGRAM
Switch For technical support use only
5 K-NET TERM
Switch For line termination
6 PROGRAM
(USB) Connector Connect to a computer for unit
configuration
7 IR IN Receiver Receives IR remote commands
8 RELAY
Connections Connect to room items (such
as lighting, screen settings,
blinds, and so on)
9 IR Connections Control a machine via an IR
Emitter
10
RS-232
Connections Connect to the RS-232 connector
on the A/V equipment or a PC or
other Serial Controller
11
K-NET 2
Connections
12
K-NET 1
Connections
On K-NET 1 and K-NET 2,
PIN GND is for the Ground
connection
3
; PIN B (-) and PIN
A (+) are for RS-485, and PIN
+12V is for powering the unit
13
FACTORY
RESET Button Press to revert to the default
settings, including all the
configured buttons
1 This European version has LCD labels
2 By the system integrator only
3 The ground connection is sometimes connected to the shield of the RS-485 cable (in most applications, it is not connected)

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Installing the Room Controller
8
4.3 Defining the RC-63D, RC-63DP and RC-63DL
The Kramer RC-63D is available as a 2 Gang wall plate for the USA or a 2 Gang
wall plate for Europe. It features 6 front panel buttons designed in two groups;
one group of 2 buttons, and another group of 4 buttons. Each group can be
programmed according to the user's requirements. LCD and plastic cap variations
are available:
RC-63D has the DISPLAY and SOURCES labels printed on the unit
RC-63DP has a backlit plastic cap to which you can insert a label from a set
of supplied stickers
RC-63DL is the default room controller included as part of the
SummitView™ Standard Kit Box and the SummitView™ Essentials Kit Box
and described in that user manual, and has an LCD label, letting you program
the required group label, as well as rolling text on the display
The RC-63D also includes:
A digital volume control adjustment knob with five LEDs
Two relays for the simplified and centralized control of room functions (such
as lighting, closing blinds, screen settings, and so on)
An IR output, a bi-directional RS-232 port, and two K-NET ports
An IR-learner for the customized control of external sources, memorizing the
IR commands from different remote transmitters
A USB port is included for programming the RC-63D via a computer.
Figure 3, Figure 4, Table 5 and Table 6 define the RC-63D, RC-63DL and
RC-63DP.
Version for Europe
Version for the USA
Figure 3: RC-63D Room Controller Front Panel

Installing the Room Controller
9
Table 5: RC-63D Front Panel Features
# Feature Function
1 SOURCE Buttons These 4 configurable backlit buttons can set up any supported command
1
2 “DISPLAY” and
“SOURCE” Labels
RC-63D - "DISPLAY" and “SOURCE” are printed on the panel
RC-63DP - backlit plastic cap to affix your own labels (see Figure 10)
RC-63DL - an LCD version on a blue background that displays up to 8 characters
at once (programmed via the USB port) and includes rolling text
3 DISPLAY Buttons These 2 configurable backlit buttons can set up any supported command
1
4 VOLUME LED Lights red, indicating maximum volume
5 VOLUME LEDs Lights green, indicating volume level
6 VOLUME Knob Rotate clockwise to increase the level
Version for Europe
Version for the USA
Figure 4: RC-63D Room Controller Rear Panel
Table 6: RC-63D Rear Panel Features
# Feature Function
1 FIRMWARE UPGRADE Switch For technical support use only
2 Grounding Screw Connect to grounding wire
3 K-NET TERM Switch For line termination
4 PROGRAM (USB) Connector Connect to a computer for unit configuration
5 IR IN Receiver Receives IR remote commands
6 RELAY Connections Connect to room items (such as lighting, screen settings, and so on)
7 IR Connections Control a machine via an IR Emitter
8 RS-232 Connections Connect to the RS-232 connector on the A/V equipment or a PC or
other Serial Controller
9 K-NET 2 Connections
10 K-NET 1 Connections
On K-NET 1 and K-NET 2, PIN GND is for the Ground
connection
2
; PIN B (-) and PIN A (+) are for RS-485, and PIN
+12V is for powering the unit
11 FACTORY RESET Button Press to revert to the default settings, including all the configured
buttons
1 By the system integrator only
2 The ground connection is sometimes connected to the shield of the RS-485 cable (in most applications, it is not connected)

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Using Your Room Controller
10
5 Using Your Room Controller
This user manual is applicable once the unit is installed and configured
1
. The
installation process is not detailed in this user manual, and includes:
Configuration via the Windows®-based configuration software and/or the IR
learner
Setting up the labels on the buttons, according to your specific requirements
2
Hardware installation
Connecting the display
When the room controller functions as a standalone, wall-mounted room
controller, as illustrated in Figure 6:
The controlled machines are connected directly to the room controller
A power supply unit is required
It requires programming
3
The power supply pinout is defined in Figure 5:
Black = GND
PINOUT
Red = +12V
RC-63DL Room Controller
To power supply
Figure 5: RC-63D Standalone Power Supply Pinout
The room controller is easy to use, as the example in Figure 6 and Table 7
defines
4
:
1 By authorized Kramer technical personnel or by an external system integrator
2 It is recommended to place labels on the buttons prior to installing the unit, as this involves removing the face plate
3 Refer to the separate online “RC-SV Configuration Guide” at http://www.kramerelectronics.com
4 Your room controller was installed and configured to suit your specific requirements. This example describes how to setup
one of an unlimited number of available setups for the system

Using Your Room Controller
11
Figure 6: Example of a Typical RC-63DL Configuration
Table 7: Connection Scheme (for the example in Figure 6)
This connector: Connects to:
REL 1
REL 2 The screen
IR OUT and GND PINs A DVD player
RS-232 (TX, RX) Terminal Block Connector A projector
+12V and GND A power supply unit
1
A PC is connected via the USB connector for setup of the room controller
1 Optional, see Table 9

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Using Your Room Controller
12
When the room controller is used as a system controller for the SummitView™
system via the proprietary communication channel K-NET, as illustrated in
Figure 7:
It requires only a K-NET connection to the SV-551 SummitView™ Processor
/ Switcher
A power supply unit is not required
1
No programming of the room controller is needed
Figure 7 shows how the room controller is used as part of the SummitView™
system:
SV-551
To 5A Power Supply
Room Controller
Black = GND
PINOUT
Red = +12V
Green = A
White = B
Figure 7: RC-63D connected to the SV-551 SummitView™ Processor / Switcher
1 Power supplies are sold separately. Consult your Kramer dealer for details

Using Your Room Controller
13
5.1 Operating the Room Controller
In the following example
1
that is illustrated in Figure 8, the room controller is
labeled with specific functions and each button is programmed
2
to perform
several tasks
3
as defined in Table 8.
Table 8: The Commands Configuration
The Label The Macro Sequence
ON Power up the projector
Power up the DVD player
Roll down the projector screen
1 minute delay [for the projector to heat
up]
The projector selects the DVD input
OFF Power down the projector
Stop the DVD player
Power down the DVD player
Stop the VCR
Power down the VCR
Roll up the projector screen
DVD Stop the video player
The projector selects the DVD input
Play the DVD
VCR Stop the DVD
The projector selects the VCR input
Play the VCR
ROOM
Figure 8: RC-63DL Labels Setup
VOLUME Use the VOLUME knob to adjust the
audio level
5.2 Using the Macro Buttons
Pressing any button initiates a macro sequence
4
, during which the button blinks
(as programmed by the system integrator).
1 This is only one example among numerous possibilities, each button can be configured as required. In this example, two
buttons are not assigned
2 By the technical installer
3 A macro sequence, including several commands per button, carried out one after the other
4 The macro sequence can be carried out instantly or can take a while, depending on the delay times included in the sequence

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Customizing the Controllers' Buttons and Labels
14
6 Customizing the Controllers' Buttons and Labels
This section describes the button and panel labels.
6.1 Button Labels
The backlit buttons
1
are available on plastic caps. We recommend you to insert
the labels on the Front Panel buttons before installing the controller, as it involves
removing the face plate. Figure 9 illustrates the button labels for the macro
buttons
2
:
Figure 9: Sample “Button Labels” Sheet
1 You can program the color of the button with flexible RGB values
2 Installed by the system integrator only

Customizing the Controllers' Buttons and Labels
15
6.2 Panel Labels
Figure 10 illustrates the sample "Labels" sheet
1
supplied with the RC-62P,
RC-62AP and the RC-63DP, for inserting under the plastic caps:
Figure 10: Sample “Panel Labels" Sheet
1 Installed by the system integrator only

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Technical Specifications
16
7 Technical Specifications
Table 9 defines the technical specifications:
Table 9: Technical Specifications
1
of the Room Controller Series
PORTS: 1 RS-232 on terminal block connectors; 2 K-NET on terminal block connectors;
1 USB port
OUTPUTS: 2 relays on terminal block connectors (36V AC or DC, 2A, 60VAC maximum on
non-inductive load); 1 IR emitter on terminal block connectors
POWER SOURCE: RC-62/RC-63A: 12V DC, 100mA
RC-62L/RC-63D: 12V DC, 140mA
RC-63DL: 12V DC, 200mA
FUSE: 500mA, FSMD 2920
ADAPTER: SummitView™ kits: 12V, 5A; independent: 12V/500mA
DIMENSIONS: RC-62 (for the USA): 6.9cm x 2.6cm x 11.4cm (2.72" x 1.02" x 4.49", W, D, H)
RC-63A and RC-63D: (for the USA): 11.4cm x 2.6cm x 11.4cm (4.49" x 1.02" x
4.49", W, D, H)
RC-62 and RC-63D (for Europe): 15.2cm x 1.9cm x 8.6cm (5.98" x 0.75" x
3.39", W, D, H)
WEIGHT: 0.14kg. (0.31lbs.) approx.
ACCESSORIES: USB cable 3' (0.91m)
2
, screwdriver, Windows®-based Kramer control software
OPTIONS: 12V DC, 0.5A Power supply
3
Kramer 3.5mm to IR Emitter Control Cable (C-A35/IRE-10), 15 meter and 20 meter
IR emitter extension cables
1 Specifications are subject to change without notice
2 Part number C-UA/MUB-3
3 Model number AD2512C, part number 2535-000251

17
LIMITED WARRANTY
WHO IS PROTECTED?
WHAT IS COVERED AND WHAT IS NOT COVERED
WHAT WE WILL PAY FOR AND WHATWE WILL NOT PAY FOR
HOW YOU CAN GET WARRANTY SERVICE
LIMITATION OF IMPLIED WARRANTIES
EXCLUSION OF DAMAGES
CAUTION!
Kramer Electronics (hereafter ) warrants this product free from defects in material and workmanship under the
followingterms.
Kramer
HOW LONG IS THE WARRANTY
Labor and parts are warranted for seven years from the date of the first customer purchase.
Only the first purchase customer may enforce this warranty.
We will pay laborand material expenses for covered items. We will not payforthe following:
Theliability of Kramer for anyeffective products is limited to the repair or replacement of the product atour option. Kramer shall
not be liable for:
Thiswarranty givesyou specific legal rights, andyoumay also have other rights,whichvary from place toplace.
Allproducts returned to Kramer for service musthaveprior approval.Thismay beobtainedfromyour dealer.
Thisequipment has beentestedto determinecompliance withthe requirements of:
EN-50081: "Electromagnetic compatibility(EMC);
genericemissionstandard.
Residential, commercial and light industry"
EN-50082: "Electromagnetic compatibility(EMC) genericimmunity standard.
Part 1: Residential, commercial andlight industryenvironment".
CFR-47: FCC Rules and Regulations:
Part 15: “Radio frequency devices
Subpart B Unintentional radiators”
Except as below, this warranty covers all defects in material or workmanship in this product. The following are not covered
by the warranty:
1. Any product which is not distributed by Kramer, or which is not purchased from an authorized Kramer dealer. If you are
uncertain as to whether a dealer is authorized, please contact Kramer at one of the agents listed in the Web site
www.kramerelectronics.com.
2. Any product, on which the serial number has been defaced, modified or removed, or on which the WARRANTY VOID
TAMPERED sticker hasbeen torn,
3. Damage, deterioration or malfunction resultingfrom:
i) Accident, misuse, abuse, neglect, fire, water, lightning or otheracts of nature
ii) Product modification, or failure to follow instructions supplied withthe product
iii) Repair or attemptedrepair by anyone not authorized byKramer
iv) Anyshipment of the product(claims must be presentedto the carrier)
v) Removal orinstallation of the product
vi) Anyother cause, which does not relateto a product defect
vii) Cartons, equipment enclosures, cables or accessories used inconjunction with the product
1. Removal orinstallationscharges.
2. Costs of initial technical adjustments (set-up), including adjustment of user controls or programming. These costs are the
responsibility of the Kramerdealerfromwhomthe product was purchased.
3. Shippingcharges.
1. To obtain service on you product, you must take or ship it prepaid to any authorized Kramer service center.
2. Whenever warranty service is required, the original dated invoice (or a copy) must be presented as proof of warranty
coverage, and should be included in any shipment of the product. Please also include in any mailing a contact name,
company, address, and a description of the problem(s).
3. For the name of the nearest Kramer authorized service center, consult your authorized dealer.
All implied warranties, including warranties of merchantability and fitness for a particular purpose, are limited in duration to
the length of this warranty.
1. Damage to other property caused by defects in this product, damages based upon inconvenience, loss of use of the product, loss
of time, commercialloss; or:
2. Anyother damages, whether incidental, consequential or otherwise. Some countries may not allow limitations on how long an
implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitationsand exclusions maynot applyto you.
Servicing the machines can only be done by an authorized Kramer technician. Any user who makes changes or
modifications to the unit without the expressed approval of the manufacturer will void user authority to operate the
equipment.
Usethe suppliedDCpowersupplytofeed powertothemachine.
Please userecommended interconnection cables to connect the machine to other components.
IF reattached, removed or otherwise interferedwith.
NOTE:
Part 1:

Kramer Electronics, Ltd.
Web site: www.kramerelectronics.com
P/N: 2900-000473 REV 1
For the latest information on our products and a list of Kramer
distributors, visit our Web site: www.kramerelectronics.com,
where updates to this user manual may be found.
We welcome your questions, comments and feedback.
Caution
Safety Warning:
Disconnect the unit from the power supply before
opening/servicing.
Other manuals for RC-62
1
This manual suits for next models
8
Table of contents
Other Kramer Controllers manuals

Kramer
Kramer SL-280 User manual

Kramer
Kramer KT-107-INWL User manual

Kramer
Kramer FC-18 User manual

Kramer
Kramer PT-12 User manual

Kramer
Kramer RC-7B User manual

Kramer
Kramer RC-7B User manual

Kramer
Kramer PT-12 User manual

Kramer
Kramer FC-10ETH User manual

Kramer
Kramer FC-18 User manual

Kramer
Kramer SL-1N User manual

Kramer
Kramer RC-63DLN User manual

Kramer
Kramer FC-10ETH User manual

Kramer
Kramer RC-2 User manual

Kramer
Kramer SL-10 User manual

Kramer
Kramer SL-1N User manual

Kramer
Kramer RC-13TC User manual

Kramer
Kramer FC-22ETH User manual

Kramer
Kramer SL-12 User manual

Kramer
Kramer SL-12 User manual

Kramer
Kramer KC-Virtual Brain5 User manual