Kramer SL-12 User manual

Kramer Electronics, Ltd.
Preliminary
USER MANUAL
Model:
SL-12
Master Room Controller

Contents
i
Contents
1Introduction 1
2Getting Started 1
2.1 Quick Start 2
3Overview 3
4Your SL-12 Master Room Controller 4
5Connecting the SL-12 Master Room Controller 5
5.1 Using the RC-4 IR transmitter 7
5.2 Connecting the RS-232 Interface 7
5.3 Connecting the RS-485 Interface 7
5.4 Connecting the Ethernet Port 8
5.5 Connecting the K-NET Port 8
6Operating the SL-12 Master Room Controller 9
7Technical Specifications 9
Figures
Figure 1: SL-12 Master Room Controller 4
Figure 2: Connecting the SL-12 Master Room Controller 6
Figure 3: RS-232 Connection 7
Figure 4: RS-485 Connection 7
Figure 5: K-NET Pinout Connection 8
Tables
Table 1: SL-12 Master Room Controller Functions 4
Table 2: SL-12 Master Room Controller Technical Specifications 9

Introduction
1
1
1 Introduction
Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been
providing a world of unique, creative, and affordable solutions to the vast
range of problems that confront the video, audio, presentation, and
broadcasting professional on a daily basis. In recent years, we have
redesigned and upgraded most of our line, making the best even better! Our
1,000-plus different models now appear in 11 groups1
Thank you for purchasing the Kramer MultiTOOLS®SL-12 Master Room
Controller, which is ideal for:
that are clearly
defined by function.
•Controlling multimedia rooms, such as classrooms, auditoriums,
conference rooms, and so on, while enabling remote control and
management of the AV equipment
•Production studios, rental, and staging
Each package includes the following items:
•The SL-12 Master Room Controller
•Kramer K-Config configuration software
•Power supply and this user manual2
2 Getting Started
We recommend that you:
•Unpack the equipment carefully and save the original box and
packaging materials for possible future shipment
•Review the contents of this user manual
•Use Kramer high-performance high-resolution cables
1 GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Matrix Switchers; GROUP 3: Control Systems;
GROUP 4: Format/Standards Converters; GROUP 5: Range Extenders and Repeaters; GROUP 6: Specialty AV Products;
GROUP 7: Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9: Room Connectivity;
GROUP 10: Accessories and Rack Adapters; GROUP 11: Sierra Products
2 Download up-to-date Kramer user manuals from our Web site at http://www.kramerelectronics.com

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Getting Started
2
2.1 Quick Start
This quick start chart summarizes the basic setup and operation steps.

Overview
3
3
3 Overview
The SL-12 is a highly versatile controller that acts as an all-in-one control
processor for control of A/V equipment—especially projectors and
associated equipment—in any room (such as classrooms, boardrooms, or
auditoriums). It streamlines operations and simplifies control by integrating
audio, video, and computer-video sources into a centralized system.
The SL-12 Master Room Controller features:
•4 general purpose I/O ports that can be configured as analog inputs,
digital inputs, or digital outputs for interfacing with a variety of devices
such as sensors, switches, LEDs, and relays
•4 bidirectional RS-232 ports that control AV equipment such as
projectors, LCD and PDP displays, power amplifiers, switchers and
scalers
•8 relay contact closure ports that control other room items related to the
AV system such as raising and lowering drapes, the screen or the
projector
•IR control on 2 inputs (3.5mm) and 4 outputs (terminal blocks)
•IR Learning that learns commands from any IR remote
•1 RS-485 serial port
•Compatibility with Kramer Site-CTRL software for network remote
control and management over the Ethernet port
•A K-NET™ control channel that connects compatible user interfaces
and supplies power and control data over a single cable
•A USB port for uploading a configuration file
•Status LEDs for all functions
•Flexible control via Ethernet, K-NET™, RS-485, an IR sensor and
external IR commands
To achieve the best performance:
•Use only good quality connection cables1
•Position your Kramer SL-12 away from moisture, excessive sunlight
and dust
1 Available from Kramer Electronics on our Web site at http://www.kramerelectronics.com

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Your SL-12 Master Room Controller
4
4 Your SL-12 Master Room Controller
Figure 1 and Table 1 define the unit.
Figure 1: SL-12 Master Room Controller
Table 1: SL-12 Master Room Controller Functions
#
Feature
Function
1 ETHERNET RJ-45 Connector Connects to the PC or other serial controller through computer
networking LAN
2 DEFAULT Recessed Pushbutton Press to reset to factory default definitions
1
3
:
IP number −192.168.1.39, Mask – 255.255.0.0,
Gateway – 0.0.0.0
IR Output Terminal Blocks Connect to IR emitter cables (from 1 to 4)
4 GPI/O Terminal Blocks Connect to various analog and digital sensors (from 1 to 4)
5 RELAYS Terminal Blocks Connect to low-voltage relay-driven devices (from 1 to 8)
6 RS-232 Terminal Blocks Connect to the RS-232 devices (from 1 to 4)
7 RS-485 Terminal Block Pins B (-) and A (+) are for RS-485; Pin G may be connected to
the shield (if required)
8 K-NET2PIN GND is for the Ground connectionConnector 3
9
; PIN B (-) and PIN A
(+) are for RS-485, and PIN +12V is for powering the unit
RS-485 TERM Switch Slides down for RS-485 termination, slides up for not
terminated
10 K-NET TERM Switch Slides down for K-NET termination, slides up for not
terminated
11 PROG. Switch For service use only
1 First disconnect the power supply and then connect it again while pressing the DEFAULT button. The unit powers up and
loads its memory with the factory default definitions and erases all stored presets
2 K-NET is a proprietary Kramer protocol for interconnecting Kramer units
3 The ground connection is sometimes connected to the shield of the RS-485 cable (in most applications, it is not connected)

Connecting the SL-12 Master Room Controller
5
5
#
Feature
Function
12 12V DC 12V DC connector for powering the unit
13 IR INPUTS Sensor and Status LED Accepts IR remote commands
14 IR INPUTS 3.5mm Mini Jacks Connect to remote infrared sensors (1 and 2)
15 RELAYS LEDs Illuminate when an relay is active (1 to 8)
16 IR LEDs Illuminate when an IR port is active
17 NET LED Illuminates when the Ethernet link is active
18 K-NET LED Illuminates while transmitting over K-NET
19 RS-485 LED Illuminates while transmitting/receiving on an RS-485 port
20 RS-232 (Tx/Rx)LEDs Illuminate while transmitting/receiving on an RS-232 port
(1 to 4)
21 GPI/O LEDS Illuminate while transmitting/receiving on a general purpose
I/O port (1 to 4)
22 PROGRAM USB Connector Connect to a computer for unit configuration and firmware
upgrading
5 Connecting the SL-12 Master Room Controller
To connect the SL-12, as the example in Figure 2 illustrates, do the following1
1. Connect the RELAY terminal block connectors as follows:
:
Connect RELAY 1 and 2 to the projector lift
Connect RELAY 3 and 4 to the screen
Connect RELAY 5 and 6 to the blinds
Connect RELAY 7 and 8 to the lighting system
2. Connect the GPI/O ports as follows:
Connect GPI/O 2 to motion detector 1
Connect GPI/O 4 to motion detector 2
3. Connect the IR outputs as follows:
Connect an IR emitter2
Connect an IR emitter
to IR OUTPUT 1 and attach the emitter to
the DVD player 2to IR OUTPUT 2 and attach the emitter to
the power amplifier
4. Connect the IR sensors as follows:
Connect IR INPUT 1 to IR sensor3
Connect IR INPUT 2 to IR sensor 1
32
1 Switch OFF the power on each device before connecting it to your SL-12. After connecting your SL-12, switch on its power
and then switch on the power on each device
2 P/N: C-A35/IRE-10; two IR Emitter Extension Cables are also available: a 15 meter cable and a 20 meter cable
3 P/N: 95-0104050

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Connecting the SL-12 Master Room Controller
6
5. Connect the RS-232 ports as follows:
Connect RS-232 port 1 to the projector
Connect RS-232 port 3 to the plasma display
6. Connect the RS-485 to several Kramer matrices, for example1
7. Connect the Ethernet port to a network.
.
8. Connect the K-NET port to any RC device with K-NET.
Figure 2: Connecting the SL-12 Master Room Controller
1 Not shown in Figure 2

Connecting the SL-12 Master Room Controller
7
7
5.1 Using the RC-4 IR transmitter
You can use the optional RC-4 IR transmitter as an auxiliary control panel
and initiate configured control macros—refer to the K-Config configuration
guide—via the built in IR receiver on the front panel, or, instead, via an
optional external wired IR receiver1
5.2 Connecting the RS-232 Interface
, which exists in several cable lengths.
To connect an AV device to the SL-12 using the RS-232 port, connect the
RS-232 9-pin D-sub port on your device to the RS-232 terminal block on
the rear panel of the SL-12 as shown in Figure 3:
Figure 3: RS-232 Connection
5.3 Connecting the RS-485 Interface
To connect an AV device to the SL-12 using the RS-485 port, connect the
RS-485 port on your device to the RS-485 terminal block on the rear panel
of the SL-12 as shown in Figure 4:
Figure 4: RS-485 Connection
1 Model: C-A35M/IRR-50

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Connecting the SL-12 Master Room Controller
8
5.4 Connecting the Ethernet Port
The Ethernet connection of the SL-12 allows you to perform all control
functions of the SL-12 over the Internet using a PC running the Kramer
Site-CTRL control program.
To connect the SL-12 to a network:
1. Connect the Ethernet port of the SL-12 to the Ethernet port on a network hub
or network router, via a straight cable with RJ-45 connectors.
2. At the other end, connect the Internet to a PC running Site-CTRL.
After connecting the Ethernet port, you have to install and configure it. For
detailed instructions on how to install and configure your Ethernet port, see
the K-Config Configuration Guide1
5.5 Connecting the K-NET Port
.
The K-NET port is wired as shown in Figure 5.
Figure 5: K-NET Pinout Connection
1 Available for download at the Kramer Web site: www.kramerelectronics.com

Operating the SL-12 Master Room Controller
9
9
6 Operating the SL-12 Master Room Controller
You can operate your SL-12 using:
•An RC family remote controller:
To operate your device using an RC remote controller, see the Kramer
K-Config Guide1
•The optional RC-4 infrared remote control transmitter
2
•A PC running Site-CTRL control software:
To operate your device using Site-CTRL, see the Site-CTRL and
Web Access Online User Guide
:
To operate your device using the infrared remote controller, see the
User Manual packed with the remote controller
1
7 Technical Specifications
The SL-12 technical specifications are shown in Table 2:
Table 2: SL-12 Master Room Controller Technical Specifications3
INPUTS:
4 RS-232, RS-485, 4 GPI/O and K-NET on terminal block connectors;
Ethernet on an RJ-45 connector; 1 infrared sensor, 2 infrared on 3.5mm
mini jack connectors; 1 USB for programming
OUTPUTS: 4 infrared, 8 relays (36V AC or DC, 2A, 60VAC maximum on non-inductive
load) and 4 GPI/O on terminal block connectors
DEFAULT IP SETTINGS: IP number − 192.168.1.39; Mask – 255.255.0.0; Gateway – 0.0.0.0
INDICATORS: LED indicator for each function
POWER SOURCE: 12V DC over K-NET connection
DIMENSIONS 14.3cm x 12.2cm x 4.4cm (5.6" x 4.8" x 1.7") W, D, H
WEIGHT: 0.6kg (1.4lbs)
ACCESSORIES: Power supply, K-Config configuration software
OPTIONS: RK-13 19” rack mount, RC-4 remote controller, IR emitter cables
4
, IR sensor
cable5
1 Available for download at the Kramer Web site: www.kramerelectronics.com
2 The RC-4 is configured via the Kramer K-Config software
3 Specifications are subject to change without notice
4 P/N: C-A35/IRE-10; two IR Emitter Extension Cables are also available: a 15 meter cable and a 20 meter cable
5 P/N: 95-0104050

10
LIMITED WARRANTY
WHOISPROTECTED?
WHATISCOVEREDANDWHATISNOTCOVERED
WHATWEWILLPAYFORANDWHATWEWILLNOTPAYFOR
HOW YOU CAN GET WARRANTY SERVICE
LIMITATIONOFIMPLIEDWARRANTIES
EXCLUSIONOFDAMAGES
CAUTION!
Kramer Electronics (hereafter ) warrants this product free from defects in material and workmanship under the
followingterms. Kramer
HOWLONGISTHE WARRANTY
Labor and parts are warranted for seven years from the date of the first customer purchase.
Only the first purchase customer may enforce this warranty.
Wewillpaylaborandmaterialexpensesforcovereditems.Wewillnotpayforthefollowing:
The liability of Kramerfor any effective productsis limited to the repairor replacement of the product at our option.Kramer shall
notbeliable for:
Thiswarrantygivesyouspecificlegalrights,andyoumayalsohaveotherrights,whichvaryfromplacetoplace.
AllproductsreturnedtoKramerforservicemusthavepriorapproval.Thismaybeobtainedfromyourdealer.
Thisequipmenthasbeentestedtodeterminecompliancewiththerequirementsof:
EN-50081: "Electromagneticcompatibility(EMC);
genericemissionstandard.
Residential,commercialandlightindustry"
EN-50082: "Electromagneticcompatibility(EMC)genericimmunitystandard.
Part1:Residential,commercialandlightindustryenvironment".
CFR-47: FCC* Rules and Regulations:
Part 15: “Radio frequency devices
Subpart B Unintentional radiators”
Except as below, this warranty covers all defects in material or workmanship in this product. The following are not covered
bythewarranty:
1. Any product which is not distributed by Kramer, or which is not purchased from an authorized Kramer dealer. If you are
uncertain as to whether a dealer is authorized, please contact Kramer at one of the agents listed in the Web site
www.kramerelectronics.com.
2. Any product, on which the serial number has been defaced, modified or removed, or on which the WARRANTY VOID
TAMPERED sticker has been torn,
3. Damage,deteriorationormalfunctionresultingfrom:
i) Accident,misuse,abuse, neglect,fire, water,lightningorotheractsofnature
ii) Productmodification,orfailuretofollowinstructionssuppliedwiththeproduct
iii) RepairorattemptedrepairbyanyonenotauthorizedbyKramer
iv) Anyshipmentoftheproduct(claimsmustbepresentedtothe carrier)
v) Removalorinstallationoftheproduct
vi) Anyothercause,whichdoesnotrelatetoaproductdefect
vii) Cartons,equipmentenclosures,cablesoraccessoriesusedinconjunctionwiththeproduct
1. Removalorinstallationscharges.
2. Costs of initial technical adjustments (set-up), including adjustment of user controls or programming. These costs are the
responsibilityoftheKramerdealerfromwhomtheproductwaspurchased.
3. Shippingcharges.
1. To obtain service on you product, you must take or ship it prepaid to any authorized Kramerservice center.
2. Whenever warranty service is required, the original dated invoice (or a copy) must be presented as proof of warranty
coverage, and should be included in any shipment of the product. Please also include in any mailing a contact name,
company, address, and a description of the problem(s).
3. For the name of the nearest Kramer authorized service center, consult your authorized dealer.
All implied warranties, including warranties of merchantability and fitness for a particular purpose, arelimited in duration to
the length of this warranty.
1. Damagetootherpropertycausedbydefectsinthisproduct,damagesbaseduponinconvenience,lossofuseof theproduct,loss
oftime,commercialloss;or:
2. Any other damages, whether incidental,consequential or otherwise.Somecountriesmaynotallow limitations onhow long an
implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitationsandexclusionsmaynotapplytoyou.
Servicing the machines can only be done by an authorized Kramer technician. Any user who makes changes or
modifications to the unit without the expressed approval of the manufacturer will void user authority to operate the
equipment.
UsethesuppliedDCpowersupplytofeedpowertothemachine.
Pleaseuserecommended interconnection cablestoconnect the machineto other components.
IF reattached, removed or otherwise interfered with.
*FCCandCEapprovedusingSTPcable(fortwistedpairproducts)
NOTE:
Part1:

Kramer Electronics, Ltd.
Web site: www.kramerelectronics.com
E-mail: info@kramerel.com
P/N: 2900-000552 REV 2
For the latest information on our products and a list of Kramer
distributors, visit our Web site: www.kramerelectronics.com
where updates to this user manual may be found.
We welcome your questions, comments and feedback.
Caution
Safety Warning:
Disconnect the unit from the power supply before
opening/servicing.
Other manuals for SL-12
2
This manual suits for next models
1
Table of contents
Other Kramer Controllers manuals

Kramer
Kramer RC-2 User manual

Kramer
Kramer RC-6 User manual

Kramer
Kramer FC-22ETH User manual

Kramer
Kramer SL-10 User manual

Kramer
Kramer FC-28 User manual

Kramer
Kramer RC-63DLN User manual

Kramer
Kramer RC-7RL User manual

Kramer
Kramer RC-76R User manual

Kramer
Kramer VA-4H User manual

Kramer
Kramer SL-240C User manual

Kramer
Kramer FC-10ETH User manual

Kramer
Kramer RC-8IR User manual

Kramer
Kramer FC-18 User manual

Kramer
Kramer RC-62 User manual

Kramer
Kramer RC-13TC User manual

Kramer
Kramer RC-52N User manual

Kramer
Kramer SL-12 User manual

Kramer
Kramer K-NET RC-53D User manual

Kramer
Kramer RC-54DL User manual

Kramer
Kramer RC-63DLN User manual