manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Kramer
  6. •
  7. Extender
  8. •
  9. Kramer WP-2UT/R-KIT User manual

Kramer WP-2UT/R-KIT User manual

This manual suits for next models

1

Other Kramer Extender manuals

Kramer VM-2HDT User manual

Kramer

Kramer VM-2HDT User manual

Kramer VA-4X User manual

Kramer

Kramer VA-4X User manual

Kramer TP-300FW User manual

Kramer

Kramer TP-300FW User manual

Kramer PT-2H User manual

Kramer

Kramer PT-2H User manual

Kramer TP-600TR User manual

Kramer

Kramer TP-600TR User manual

Kramer PT-571 User manual

Kramer

Kramer PT-571 User manual

Kramer TP-780RXR User manual

Kramer

Kramer TP-780RXR User manual

Kramer PT-871xr User manual

Kramer

Kramer PT-871xr User manual

Kramer PT-871/2-KIT User manual

Kramer

Kramer PT-871/2-KIT User manual

Kramer VP-43 User manual

Kramer

Kramer VP-43 User manual

Kramer PT-3H2 User manual

Kramer

Kramer PT-3H2 User manual

Kramer VP-14 User manual

Kramer

Kramer VP-14 User manual

Kramer VM-3DT User manual

Kramer

Kramer VM-3DT User manual

Kramer TP-600TRxr User manual

Kramer

Kramer TP-600TRxr User manual

Kramer VP-14 User manual

Kramer

Kramer VP-14 User manual

Kramer FC-50 User manual

Kramer

Kramer FC-50 User manual

Kramer RS-232 User manual

Kramer

Kramer RS-232 User manual

Kramer EXT3-21-XR-TR User manual

Kramer

Kramer EXT3-21-XR-TR User manual

Kramer EXT3-C-XR-TR User manual

Kramer

Kramer EXT3-C-XR-TR User manual

Kramer K-Able/XL Box User manual

Kramer

Kramer K-Able/XL Box User manual

Kramer TP-600TRxr User manual

Kramer

Kramer TP-600TRxr User manual

Kramer KW-14R User manual

Kramer

Kramer KW-14R User manual

Kramer EXT3-U-KIT User manual

Kramer

Kramer EXT3-U-KIT User manual

Kramer PT-100 User manual

Kramer

Kramer PT-100 User manual

Popular Extender manuals by other brands

Paugge ENT-EXT20B user manual

Paugge

Paugge ENT-EXT20B user manual

REIGN XRE-100 manual

REIGN

REIGN XRE-100 manual

Lindy 42805 user manual

Lindy

Lindy 42805 user manual

Digi ConnectPort Network Device user manual

Digi

Digi ConnectPort Network Device user manual

British General N300 instructions

British General

British General N300 instructions

VPI ST-WLHDMI-L-30M Installation and operation manual

VPI

VPI ST-WLHDMI-L-30M Installation and operation manual

Gefen EXT-DIGAUD-141 user manual

Gefen

Gefen EXT-DIGAUD-141 user manual

AMX netlinx NXC-MPE Dimensional drawing

AMX

AMX netlinx NXC-MPE Dimensional drawing

SY HDBT-60T installation guide

SY

SY HDBT-60T installation guide

Appsys ProAudio ADX-16 user manual

Appsys ProAudio

Appsys ProAudio ADX-16 user manual

Atlona RS232 user manual

Atlona

Atlona RS232 user manual

IDK OPF-TH1000-A user guide

IDK

IDK OPF-TH1000-A user guide

Enable-IT 824WP quick start guide

Enable-IT

Enable-IT 824WP quick start guide

Worx Landroid RadioLink WA0864 Get started

Worx

Worx Landroid RadioLink WA0864 Get started

TP-Link TL-WA730RE user guide

TP-Link

TP-Link TL-WA730RE user guide

Camplex CMX-HDMI-SFPL user manual

Camplex

Camplex CMX-HDMI-SFPL user manual

SC&T HE03-4K user manual

SC&T

SC&T HE03-4K user manual

Samsung SCS-26UC4 user guide

Samsung

Samsung SCS-26UC4 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

WP-2UT/R-KIT Quick Start
P/N:
2900- 301411QS
Rev:
1
Scan for full manual
WP-2UT/R-KIT Quick Start Guide
This guide helps you install and use your WP-2UT/R-KIT for thefirst time.
Go to www.kramerav.com/downloads/WP-2UT/R-KIT to download the latest user manual and check if
firmware upgrades are available.
Step 1: Check what’s in the box
WP-2UT USB Transmitter
1 C-USB/AB-6 cable
Installation accessories
1 Bracket set
PT-2UR USB Receiver
1 Power adapter and cord
Frame set and faceplate
1 Quick start guide
Step 2: Get to know your WP-2UT/R-KIT
WP-2UT
#
Feature
Function
1
USB 2.0 Type B Port
Connect to USB host.
2
LINK LED
Flashes blue when a link is established.
3
ON LED
Lights green when locally powered by the power adapter.
Lights orange when powered by PoC.
4
Ring Tongue Terminal Grounding Screw
Connect to grounding wire (optional).
5
SRV (Tx, Rx)
5-pin Terminal Block
Connector (with a
common G pin)
Connect for firmware upgrade.
6
RS-232 (G, Rx, Tx)
Connect for serial extension (9600 baud rate).
7
Power Supply 2-pin Terminal Block
Connector
Connect to the power supply. Connect GND to GND, +12V to +12V.
8
LINK POC ◄► OUT RJ-45 Connector
Connect to the LINKIN port on the PT-2UR and to power either the device
via the receiver or the receiver by the device.
PT-2UR
WP-2UT
#
Feature
Function
9
LINK LED
Flashes blue when a link is established.
10
AUDIO OUT 3.5mm Mini Jack
Connect to an unbalanced stereo audio acceptor.
11
USB 2 Type A Ports (1 to 4)
Connect to USB devices.
Connect PT-2UR directly to the power adapter in order to charge USB
devices.
12
ON LED
Lights green when locally powered by the power adapter. Lights orange
when powered by PoC.
13
LINK IN RJ-45 Connector
Connect to the LINK OUT port on the WP-2UT and to power either the
device via the transmitter or the transmitter by the device.
14
PROG (Tx, Rx)
5-pin Terminal Block
Connector (with a
common G pin)
Connect for firmware upgrade.
15
RS-232 (G, Rx, Tx)
Connect for serial extension (9600 baud rate).
16
12V DC Power Connector
Connect to the supplied power adapter.
Step 3: Install the WP-2UT/R-KIT
WP-2UT
Insert the device into the in-wall box (note that first you need to connect the HDBT cable and power) and connect the parts as
shown in the illustrations below:
US-D Version
DECORA® design or similar frames are
included in US-D models. DECORA® is a
registered trademark of Leviton
Manufacturing Co., Inc.
We recommend that you use any of the
following standard 1 Gang in-wall junction
boxes (or their equivalent):
•US-D: 1 Gang US electrical
junction boxes.
PT-2UR
Install PT-2UR using one of the following methods:
•Attach the rubber feet and place the unit on a flat surface.
•Fasten a bracket (included) on each side of the unit and attach it to a flat surface
(see www.kramerav.com/downloads/PT-2UT/R).
•Mount the unit in a rack using the recommended rack adapter
(see www.kramerav.com/product/PT-2UT/R).
•Ensure that the environment (e.g., maximum ambient temperature &
air flow) is compatible for the device.
•Avoid uneven mechanical loading.
•Appropriate consideration of equipment nameplate ratings should be
used for avoiding overloading of the circuits.
•Reliable earthing of rack-mounted equipment should be maintained.
•Maximum mounting height for the device is 2 meters.
Step 4: Connect the inputs and outputs
Always switch OFF the power on each device before connecting it to your WP-2UT/R-KIT. For best results, we recommend
that you always use Kramer high-performance cables to connect AV equipment to the WP-2UT/R-KIT.
In the following example, devices that are connected to the PT-2UR USB ports are powered/charged while connected.
Only 9600 baud rate is supported for RS-232 communication for both WP-2UT and PT-2UR.
Grounding the WP-2UT (Optional)
1. Connect the ring tongue terminal to the building grounding point wire (a green-yellow, AWG#18 (0.82mm2) wire,
crimped with a proper hand-tool is recommended).
2. Insert the M3x6 screw through the toothed lock washers and the tongue terminal in the order shown above.
3. Insert the M3x6 screw (with the two toothed lock washers and ring tongue terminal) into the grounding screw hole
and tighten the screw.
Wiring the RJ-45 Connectors
This section defines the TP pinout, using
a straight pin-to-pin cable with RJ-45
connectors.
EIA /TIA 568B
PIN
Wire Color
1
Orange / White
2
Orange
3
Green / White
It is recommended that the cable
ground shielding be
connected/soldered to the connector
shield.
4
Blue
5
Blue / White
6
Green
7
Brown / White
8
Brown
To achieve specified extension distances, use the recommended Kramer cables available at www.kramerav.com/product/WP-2UT/R-KIT.
Using third-party cables may cause damage!
Step 5: Connect the power
Connect the 12V power adapter to the WP-2UT/R-KIT transmitter or receiver side and plug the power supply into the mains
electricity.
Safety Instructions
Caution:
•For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual.
•There are no operator serviceable parts inside the unit.
Warning:
•Use only the power cord that is supplied with the unit.
•Disconnect the power and unplug the unit from the wall before installing.
•Do not open the unit. High voltages can cause electrical shock! Servicing by qualified personnel only.
•To ensure continuous risk protection, replace fuses only according to the rating specified on the product label which located on the bottom of the unit.