ELECTRICAL SPECIFICATIONS : KM 175D
o o
Accuracy is ± (% of reading digits + number of digits) or otherwise specified, at 23 C ± 5 C
Maximum Crest Factor <2.5:1 at full scale & <5:1 at half scale or otherwise specified, and with frequency components
within the specified frequency components within the specified frequency bandwidth for non-sinusoidal waveforms.
Range
TM
AMPTIP CLAMP-ON AC CURRENT
1) 2) 3) 4)
Accuracy
Resolution
50Hz ~ 60Hz
±(1.5%rdg + 5dgts)
0.1 A
60.00 A
1) Induced error from adjacent current-carrying conductor : < 0.06A/A
2) Induced error from ACV measurement <0.60A / kV @ 50 / 60Hz
3) Add 10d to the specified accuracy @ < 6A
4) Induced non-zero residual while beeper turns on : <20d
AUDIBLE CONTINUITY TESTER
Audible Threshold Between 10 and 250W W
Response Time 32ms approx.
80ms PEAK-RMS for Clamp-on ACA
Response 80ms to > 90% of specifications,
& is specified from 2% of range.
200.0 mF
2500 mF
±(2.0%rdg + 4dgts)
CAPACITANCE
1)
Accuracy
Resolution
Range
0.1 mF
1 mF
1) Accuracies with film capacitor or better
Range
AC VOLTAGE (with Digital Low-Pass Filter)
Accuracy
Resolution
Input Impedance : 10MW, 100pF nominal
50Hz ~ 60Hz
±(1.0%rdg + 5dgts)
0.1 V
600.0 V
200.0 Am
±(1.0%rdg + 5dgts)
0.1 mA
2000 Am0.1 mA
DC A m
Accuracy
Resolution
Range
Burden Voltage : 3.5mV/ Am
REGULAR CLAMP-ON AC CURRENT
1) Induced error from adjacent current-carrying conductor : < 0.06A/A
2) Induced error from ACV measurement <0.60A / kV @ 50 / 60Hz.
3) Specified accuracy is for measurements made at the jaw center. When the
conductor is not positioned at the jaw center,add 2% to specified accuracy
for position errors.
4) Induced non-zero residual while beeper turns on : < 20d
5) Add 10d to specified accuracy @ < 6A.
1) 2) 3) 4)
Accuracy
±(1.8%rdg + 5dgts)
Resolution
0.01 A
0.1 A
Range
50Hz ~ 100Hz
5)
60.00 A
600.0 A
±(2.0%rdg + 5dgts)
0.01 A
0.1 A
100Hz ~ 400Hz
5)
60.00 A
600.0 A
-40.0ºC ~ 99.9ºC
TEMPERATURE
Range
100.0ºC ~ 400ºC
-40.0ºF ~ 99.9ºF
100ºF ~ 752ºF
1.0% ~ 0.8ºC
Accuracy1) 2)
1.0% ~ 1ºC
1.0% ~ 1.5ºF
1.0% ~ 2ºF
1)
2)
K-type thermocouple range & accuracy not included
Accuracies assume meter interior has the same temperature of the ambient
(isothermal stage) for a correct junction voltage compensation. Allow enough
time to reach the isothermal stage for a signficant change of ambient
temperature. It can take up to an hour for changes > 5°C.
3.000 V ±(1.5%rdg + 5dgts)
DIODE TESTER
Accuracy
Resolution
Range
1 mV
Test Current : 0.3mA typically Open Circuit Voltage : < 3.5VDC typical.
600.0 V ±(1.0%rdg + 5dgts)
DC VOLTAGE
Accuracy
Resolution
Range
0.1 V
Input Impedance : 10MW, 100pF nominal
RESISTANCE
600.0W
6.000KW±(1.0%rdg + 5dgts)
Accuracy
Resolution
Range
0.1 W
0.001kW
60.00KW0.01 kW
Open Circuit Voltage : 1.7VDC typical
1)Test Current : 2mA typical
2)Test Current : 0.2mA typical
600.0KW1) 0.1 kW
6000KW2) 1 kW
±(1.2%rdg + 5dgts)
HZ LINE LEVEL FREQUENCY
Accuracy :
1) DC-bias, if any, not more than 50% of Sine RMS.
1% + 5d
Function
600 V
Sensitivity (Sine RMS)1)
50 V
5.00Hz~999.9Hz
Range
EF-H
(High Sensitivity)
NON-CONTACT EF-DETECTION
Indication : Bar-graph segments & audible beep tones proportional to the
field strength
Detection Frequency : 50/60Hz
Detection Antenna : Inside the top side of the stationary jaw
Probe-Contact EF-Detection : For more precise indication of live wires, such
as distinguishing between live and ground connections, use direct contact testing
with one single test-probe via an input terminal. The COM terminal (Black)
has the test sensitivity.
10V (5V ~ 25V)
Bar-Graph
Indication
-
- -
- - -
- - - -
- - - - -
Typical Voltage (Tolerance)
EF-L
(Low Sensitivity)
25V (20V ~ 66V)
55V (50V ~ 125V)
110V (90V ~ 200V)
220V (>180V)
40V (32V ~ 70V)
110V (55V ~ 165V)
220V (130V ~ 265V)
400V (250V ~ 500V)
550V (>430V)
An ISO 9001:2008 Company
®
All Specifications are subject to change without prior notice.
G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA.
Sales Direct.: 022-24156638, Tel. : 022-24124540, 24181649, Fax : 022-24149659