manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Kusam-meco
  6. •
  7. Measuring Instrument
  8. •
  9. Kusam-meco KM 1001 User manual

Kusam-meco KM 1001 User manual

Chhaya com/D/chhaya/my documents/chhaya/backup/catlog/New catlog/2015 new arrival catalogs/KM 1001.cdr
— Display : 3½ Digit 2000 counts LCD with automatic polarity indication.
— Measuring Method : Dual-slope integration A/D converter system.
— Over range indication.
— Over load protection : Protected by PTC in the resistance range.(protection upto 500V AC RMS).
—
—
—
—
— Operating
— Storage
— Accessories :
Data Hold function : the hold & release for all display data is performed alternatively by “D.H” push switch..
Low battery indication : The “BATTERY” symbol is displayed when the battery voltage drops below accurate operating level.
Continuity function.
Power Supply : 9V Alkaline or carbon-zinc battery.
Temperature & Humidity : 0°C ~ 50°C; 80% max. R.H.
Temperature & Humidity : -20°C ~ 60°C; 80% max. R.H.
User Manual, Battery & Carrying case.
GENERAL SPECIFICATIONS :
Preliminary Data
NEW
All Specifications are subject to change without prior notice.
G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA.
Sales Direct.: 022-24156638, Tel. : 022-24124540, 24181649, Fax : 022-24149659
Email : [email protected], Website : www.kusamelectrical.com
KM 1001 Digital Clampmeter is completely portable, 3½ Digit LCD display meter.
This Clampmeter is designed for us in the Laboratory, Field servicing, at home, under any
circumstance where high current measurement is required. This meter is built with a design
of finger guard which ensures safety operating & electronic overload protection for all
function & range. In addition, a carrying case is available for easy portability of the
meter & avoiding damage. Rugged Fire retardant & Shock Resistant casing.
ELECTRICAL SPECIFICATIONS :
AC CURRENT
AC VOLTAGE
Resolution AccuracyRange
600 V 1 V ±(1.5% rdg + 4 dgts)
DC VOLTAGE
Resolution AccuracyRange
600 V 1 V ±(1.0% rdg + 2 dgts)
RESISTANCE
Resolution AccuracyRange
50 W ~ 2000 W1 W±(1.0% rdg + 2 dgts)
400A AC DIGITAL CLAMPMETER
MODEL-KM 1001
An ISO 9001:2015 Company
®
An ISO 9001:2015 Company
Resolution AccuracyRange
20 A
400 A
0.1 A ±(1.5% rdg + 4 dgts)
200 A
400A AC DIGITAL CLAMPMETER
MODEL - KM 1001
We thank you very much for your purchasing our product. Electronic measuring instruments produced by us are high technology products
under strict quality control. We guarantee exceptional precision and reliability. This clamp meter is completely portable, 3 1/2 digit LCD
display Meter. This clamp meter is designed for use in the laboratory, field servicing, at home, educational institutes. It should not be used
under any circumstance where high energy current measurement is required.
1.Introduction
This meter is built with a design of finger guard which ensures safety operating; a rugged case that is shock resistant and fire retardant:
and electronic overload protection for all function and range.
In addition, a carrying case is available for easy portability of the meter and avoiding damage.
This clamp meter has been designed according to EN61010 concerning electronic measuring instruments with a test category (CAT II
600V) and pollution 2 and safety requirements for hand-held current clamps to electronical measurement and test. Follow all safety and
operating instruction to ensure that the meter is used safely and is kept in good operating condition.
2. Safety Information:
1. While using the meter, observe all normal safety rules concerning :
2.1 Preliminary
Protection against the damage of electric shock.
Full compliance with safety standard can be guaranteed only if used with test leads supplied.
2. During use
— Never exceed the protection limit values indicated in the specifications for each range of measurement.
— When the meter is linked to measurement circuit, do not touch unused terminals.
— When the value scale to be measured is unknown, set the range selector at the highest position.
— Before rotating the selector to change function, disconnect test leads from the circuit under testing.
— Never perform resistance measurements on live circuits.
— When the jaw is opened and while the conductor is under testing, ',our fingers must keep behind the barriers indicator.
— Never ground yourself when taking electrical measurement, do not touch exposed metal pipes, outlets, fixtures, etc., which might
be at ground potential. Keep your body isolated from ground by using dry clothing, rubber shoes, or any approved insulating material.
3. Symbols
— Display: 3 1/2 digit (2000 counts) LCD, with automatic polarity indication.
— Over-range indication: Display shows "1".
— Over load protection: Protected by PTC in the resistance range. (protection up to 500V AC RMS).
— DATA HOLD function: The hold and release for all display data is performed alternatively by "D.H" push switch.
— Low battery indication: The " " symbol is displayed when the battery voltage drops below proper operating level.
— Continuity function.
— Power supply: 9V Alkaline or carbon-zinc battery (6F22, NEAD 1604 type or equivalent).
— Operating temperature and Humidity: 0°C to 50°C; 80%max. RH.
— Storage temperature and Humidity: -20°C to 60°C; 80%max. RH.
3. GENERAL SPECIFICATIONS:
4. ELECTRICAL SPECIFICATIONS:
Resolution
Range
600 V 1 V
Accuracy
±(1.0% rdg + 2 dgts)
Double insulation, protection class III.
Warning: this symbol indicated where cautionary or other information is found in the manual.
Caution: risk of electric chock. This symbol indicates where cautionary or other information is found in the manual,
Ground terminal.
®®
AN ISO 9001:2015 COMPANY
AC CURRENT AC VOLTAGE
RESISTANCE
DC VOLTAGE
Range
20 A
200 A
400 A
Resolution
0.1 A
Accuracy
±(1.5% rdg + 4 dgts)
Range
600 V
Resolution
1 V
Accuracy
±(1.5% rdg + 4 dgts)
Range
50 W ~ 2000 W1 W
Resolution Accuracy
±(1.0% rdg + 2 dgts)
1. Set function knob to the proper AC A Range. Press the trigger to open the jaws and clamp on to one conductor only.
The transformer jaws pick up the AC current flowing through the conductor.
2. When only the figure "1" displayed, it indicates over range situation and the higher range has to be selected.
3. The reading will be indicated on the display.
5. OPERATING INSTRUCTION :
5.1 Measuring Current:
(1) Jaws should he completely closed while taking a reading.
(2) The most accurate reading will be obtained by the conductor across center of the transformer jaws.
NOTE:
5.2 AC Voltage Measurement :
1. Set the function knob to the AC V range.
2. Connect the black test lead to the "COM" terminal and red test lead to the "V/W" terminal. You can now place the test probes to the
source or load under measurement.
3. When only the figure "1" is displayed, it indicates over range situation disconnect the test leads immediately to avoid damage to
the meter.
5.3 DC Voltage Measurement :
1. Set the function knob to the DC V range.
2 Connect the black test lead to the "COM' terminal and red test lead to the "V/W" terminal. You can now place the test probes to the
source or load under measurement.
3. The polarity of red lead connection will be indicated along with the voltage value.
4. When only the figure "1" is displayed, it indicated over range situation disconnect the test leads immediately to avoid damage to
the meter
5.4 Resistance Measurement :
1. Set the function knob to the “ 20000W” range
2. Connect the black test lead to the “COM” terminal and red test lead to the V/W terminal.
3. Verify that the power to the circuit under test is off. Connect test lead to the circuit to make measurement.
NOTE: If the resistance being measurement exceeds, the maximum value of the range selected or the input is not connected,
an over range indication "1' will be displayed
WARNING
To avoid electrical shock, hazard or damage to the meter, do not attempt to measure voltage that might exceed DC 600V.
To avoid electrical shock, hazard or damage to the meter, do not attempt to measure voltage that might exceed AC 600V RMS.
(1) Attempting resistance or continuity measurements on live circuits can cause electrical shock, damage to the meter and damage
to the equipment under test.
(2) Resistance measurement must be made on de-energized circuit.
5.5 Continuity Test
1. Set the function knob to the “ 20000W” range.
2. Connect the black test lead to the "COM" terminal and red test lead to the "V/W" terminal.
3. Connect the test probes across two points of the circuit under testing. If continuity exists BUZZER will sound.
6. Maintenance :
Maintenance consists of periodic cleaning and battery replacement. The exterior of the meter can be cleaned with a dry clean cloth to
remove any oil, grease. Never use liquid solvents or abrasives
Replacing Battery :
When the meter displays the sign " ", the battery must be replaced to maintain proper operation. Remove the battery cover of case.
replace the exhausted battery with new one.
To avoid electrical chock, disconnect the test leads and any input signals before replacing the battery. Replace only with same type of battery.
WARNING
17, Bharat Industrial Estate, T. J . Road, Sewree (W), Mumbai - 400015. INDIA
Sales Direct: (022)24156638 Tel.:(022) 24124540, 24181649 Fax: (022) 24149659
E-mail : [email protected], Website : www.kusamelectrical.com
®®
AN ISO 9001:2015 COMPANY
17, Bharat Industrial Estate, T. J . Road, Sewree (W), Mumbai - 400015. INDIA
Sales Direct: (022)24156638 Tel.:(022) 24124540, 24181649 Fax: (022) 24149659
E-mail : [email protected], Website : www.kusamelectrical.com
WARRANTY
Each “KUSAM-MECO” product is warranted to be free from defects in material and workmanship under normal use &
service. The warranty period is one year (12 months) and begins from the date of despatch of goods. In case any defect
occurs in functioning of the instrument, under proper use, within the warranty period, the same will be rectified by us free
of charges, provided the to and fro freight charges are borne by you.
MUMBAI
TEST CERTIFICATE
DIGITAL MULTIMETER
This Test Certificate guarantees that the product has been inspected and tested in accordance with the
published specifications.
The instrument has been calibrated by using equipment which has already been calibrated to standards
traceable to national standards.
MODEL NO. ________________
KM 1001
SERIAL NO. ___________
DATE: ___________
ISO 9001
REGISTERED
QC
PASS
KUSAM-MECO
This warranty does not apply for damaged Ic’s, fuses, disposable batteries, carrying case, test leads, or to any product
which in “KUSAM-MECO’s” opinion, has been misused, altered, neglected, contaminated or damaged by accident or
abnormal conditions of operation or handling.
This warranty extends only to the original buyer or end-user customer of a “KUSAM-MECO” authorized dealer.
“KUSAM-MECO” authorized dealer shall extend this warranty on new and unused products to end-user customers only
but have no authority to extend a greater or different warranty on behalf of “KUSAM-MECO”.
“KUSAM-MECO’s” warranty obligation is limited, at option, free of charge repair, or replacement of a defective product
which is returned to a “KUSAM-MECO” authorized service center within the warranty period.
THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. “KUSAM-MECO” SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT,
INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY
CAUSE WHATSOEVER.
All transaction are subject to Mumbai Jurisdiction.
®®
AN ISO 9001:2015 COMPANY

Other Kusam-meco Measuring Instrument manuals

Kusam-meco KM 981 MK-1 User manual

Kusam-meco

Kusam-meco KM 981 MK-1 User manual

Kusam-meco KM 088 User manual

Kusam-meco

Kusam-meco KM 088 User manual

Kusam-meco KM-6300 User manual

Kusam-meco

Kusam-meco KM-6300 User manual

Kusam-meco KM-CAL-804 User manual

Kusam-meco

Kusam-meco KM-CAL-804 User manual

Kusam-meco KM 503 User manual

Kusam-meco

Kusam-meco KM 503 User manual

Kusam-meco KM 076 User manual

Kusam-meco

Kusam-meco KM 076 User manual

Kusam-meco 108 User manual

Kusam-meco

Kusam-meco 108 User manual

Kusam-meco KM 2008A User manual

Kusam-meco

Kusam-meco KM 2008A User manual

Kusam-meco 2781 User manual

Kusam-meco

Kusam-meco 2781 User manual

Kusam-meco KM-CAL-906 User manual

Kusam-meco

Kusam-meco KM-CAL-906 User manual

Kusam-meco KM 63A User manual

Kusam-meco

Kusam-meco KM 63A User manual

Kusam-meco KM 181 User manual

Kusam-meco

Kusam-meco KM 181 User manual

Kusam-meco KM 1120 User manual

Kusam-meco

Kusam-meco KM 1120 User manual

Kusam-meco KM-01 User manual

Kusam-meco

Kusam-meco KM-01 User manual

Kusam-meco CA 3000 User manual

Kusam-meco

Kusam-meco CA 3000 User manual

Kusam-meco KM 2720 User manual

Kusam-meco

Kusam-meco KM 2720 User manual

Kusam-meco 954 MK-II User manual

Kusam-meco

Kusam-meco 954 MK-II User manual

Kusam-meco 2718 User manual

Kusam-meco

Kusam-meco 2718 User manual

Kusam-meco KM 117A User manual

Kusam-meco

Kusam-meco KM 117A User manual

Kusam-meco KM 2784-T User manual

Kusam-meco

Kusam-meco KM 2784-T User manual

Kusam-meco KM 035 User manual

Kusam-meco

Kusam-meco KM 035 User manual

Kusam-meco 500HP User manual

Kusam-meco

Kusam-meco 500HP User manual

Kusam-meco KM 072 User manual

Kusam-meco

Kusam-meco KM 072 User manual

Kusam-meco 9999 User manual

Kusam-meco

Kusam-meco 9999 User manual

Popular Measuring Instrument manuals by other brands

RBR RBRquartz3 Q Guide

RBR

RBR RBRquartz3 Q Guide

METREL MD 9272 instruction manual

METREL

METREL MD 9272 instruction manual

FRO­NIUS TS 5kA-3 quick start guide

FRO­NIUS

FRO­NIUS TS 5kA-3 quick start guide

JENCO 6011M Operation manual

JENCO

JENCO 6011M Operation manual

TV Logic LUM-095G Operation manual

TV Logic

TV Logic LUM-095G Operation manual

Hanna HI 9811 instruction manual

Hanna

Hanna HI 9811 instruction manual

TimeTronics WindSpeed user manual

TimeTronics

TimeTronics WindSpeed user manual

Ametek ta7000 user manual

Ametek

Ametek ta7000 user manual

Omicron Bode 100 user manual

Omicron

Omicron Bode 100 user manual

Güralp CMG-3ESP Operator's guide

Güralp

Güralp CMG-3ESP Operator's guide

Fluidwell F126-P-EG-TP manual

Fluidwell

Fluidwell F126-P-EG-TP manual

PCB Piezotronics INI SENSORS 683A100001 Installation and operating manual

PCB Piezotronics

PCB Piezotronics INI SENSORS 683A100001 Installation and operating manual

Tektronix IsoVu TIVM Series user manual

Tektronix

Tektronix IsoVu TIVM Series user manual

ICT SFM1 quick start guide

ICT

ICT SFM1 quick start guide

NK EmPower Oarlock quick start guide

NK

NK EmPower Oarlock quick start guide

Wohler CD 210 operating manual

Wohler

Wohler CD 210 operating manual

IBA BM-PN manual

IBA

IBA BM-PN manual

Minebea TMD-100 instruction manual

Minebea

Minebea TMD-100 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.