manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Kvaser
  6. •
  7. Recording Equipment
  8. •
  9. Kvaser U100P-X2 User manual

Kvaser U100P-X2 User manual

Other Kvaser Recording Equipment manuals

Kvaser Hybrid Pro CAN/LIN User manual

Kvaser

Kvaser Hybrid Pro CAN/LIN User manual

Kvaser Ethercan HS User manual

Kvaser

Kvaser Ethercan HS User manual

Kvaser USBcan R v2 User manual

Kvaser

Kvaser USBcan R v2 User manual

Kvaser Leaf Light R v2 User manual

Kvaser

Kvaser Leaf Light R v2 User manual

Kvaser M.2 PCIe 4xCAN User manual

Kvaser

Kvaser M.2 PCIe 4xCAN User manual

Kvaser Hybrid Pro User manual

Kvaser

Kvaser Hybrid Pro User manual

Kvaser Leaf Light v2 CB User manual

Kvaser

Kvaser Leaf Light v2 CB User manual

Kvaser U100P-X1 User manual

Kvaser

Kvaser U100P-X1 User manual

Kvaser Leaf Light v2 User manual

Kvaser

Kvaser Leaf Light v2 User manual

Kvaser USBcan Light 4xHS User manual

Kvaser

Kvaser USBcan Light 4xHS User manual

Kvaser U100-X1 User manual

Kvaser

Kvaser U100-X1 User manual

Kvaser Ethercan HS User manual

Kvaser

Kvaser Ethercan HS User manual

Kvaser Memorator Pro 2xHS v2 CB User manual

Kvaser

Kvaser Memorator Pro 2xHS v2 CB User manual

Kvaser USBcan Pro 5xHS User manual

Kvaser

Kvaser USBcan Pro 5xHS User manual

Kvaser BlackBird User manual

Kvaser

Kvaser BlackBird User manual

Kvaser Hybrid CAN/LIN User manual

Kvaser

Kvaser Hybrid CAN/LIN User manual

Kvaser Leaf User manual

Kvaser

Kvaser Leaf User manual

Kvaser Leaf Light v2 User manual

Kvaser

Kvaser Leaf Light v2 User manual

Kvaser Air Bridge Light HS User manual

Kvaser

Kvaser Air Bridge Light HS User manual

Kvaser DB9-Power Inlet User manual

Kvaser

Kvaser DB9-Power Inlet User manual

Kvaser U100-X3 User manual

Kvaser

Kvaser U100-X3 User manual

Kvaser Ethercan Light User manual

Kvaser

Kvaser Ethercan Light User manual

Kvaser BlackBird User manual

Kvaser

Kvaser BlackBird User manual

Kvaser Memorator Pro 2xHS v2 CB User manual

Kvaser

Kvaser Memorator Pro 2xHS v2 CB User manual

Popular Recording Equipment manuals by other brands

ThermoFisher Scientific Dionex DRS 600 Installation checklist

ThermoFisher Scientific

ThermoFisher Scientific Dionex DRS 600 Installation checklist

Shure ANIUSB-Matrix user guide

Shure

Shure ANIUSB-Matrix user guide

Nady Audio HE-1 user guide

Nady Audio

Nady Audio HE-1 user guide

AUDAC APM 01 User manual & installation guide

AUDAC

AUDAC APM 01 User manual & installation guide

Teac GF-350 owner's manual

Teac

Teac GF-350 owner's manual

Fractal Audio MFC-101 MARK III owner's manual

Fractal Audio

Fractal Audio MFC-101 MARK III owner's manual

bmcm USB-OI16 manual

bmcm

bmcm USB-OI16 manual

HHB BurnIT CDR-830 Service manual

HHB

HHB BurnIT CDR-830 Service manual

GE VersaMax IC200CPUE05 manual

GE

GE VersaMax IC200CPUE05 manual

IntesisBox MH-RC-MBS-1 user manual

IntesisBox

IntesisBox MH-RC-MBS-1 user manual

Attero Tech unD4l user manual

Attero Tech

Attero Tech unD4l user manual

Sennheiser UI 765 instruction manual

Sennheiser

Sennheiser UI 765 instruction manual

Sony RCD-W1 Operating Instructions  (primary... Service manual

Sony

Sony RCD-W1 Operating Instructions (primary... Service manual

Roland Planet-P  MKS-10 owner's manual

Roland

Roland Planet-P MKS-10 owner's manual

Roland BOSS GT-PRO Turbostart

Roland

Roland BOSS GT-PRO Turbostart

8x8 Inc Valcom V-2001A manual

8x8 Inc

8x8 Inc Valcom V-2001A manual

Waves SUB Align user guide

Waves

Waves SUB Align user guide

Mitsubishi Electric MAC-334IF-E installation manual

Mitsubishi Electric

Mitsubishi Electric MAC-334IF-E installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Kvaser U100P-X2 User’s Guide
Copyright 2020-2023 Kvaser AB, Mölndal, Sweden
https://www.kvaser.com
Printed Friday 5th May, 2023
We believe that the information contained herein was accurate in all respects at the time of printing.
Kvaser AB cannot, however, assume any responsibility for errors or omissions in this text. Also note
that the information in this document is subject to change without notice and should not be construed
as a commitment by Kvaser AB.
Kvaser U100P-X2 User’s Guide 2 (22)
(This page is intentionally left blank.)
Kvaser AB, Mölndal, Sweden — www.kvaser.com
Kvaser U100P-X2 User’s Guide 3 (22)
Contents
1 About this manual 4
2 Introduction 5
2.1 Welcome to Kvaser U100P-X2 . . . . . . . . . . . . . . . . . . . . . 5
2.2 Major features of Kvaser U100P-X2 . . . . . . . . . . . . . . . . . . 6
3 Kvaser U100P-X2 hardware 7
3.1 Hardware installation . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.2 USB connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.3 Kvaser MagiSync . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.4 CAN connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.5 CAN bus termination . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.6 Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.7 LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.8 Interface mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.9 Updating the firmware . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.10 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4 Troubleshooting 16
5 Safety Instructions 17
5.1 Intended Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.2 Usage Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
6 Disposal and Recycling Information 18
7 Legal Acknowledgements 19
7.1 EU Regulatory Compliance . . . . . . . . . . . . . . . . . . . . . . . 19
7.2 FCC Regulatory Compliance . . . . . . . . . . . . . . . . . . . . . . 20
7.3 Patents, Copyrights and Trademarks . . . . . . . . . . . . . . . . . . 21
8 Document Revision History 22
Kvaser AB, Mölndal, Sweden — www.kvaser.com
Kvaser U100P-X2 User’s Guide 4 (22)
1 About this manual
This manual is intended for Kvaser U100P-X2 users. This document contains a
description of the hardware’s properties and general instructions for connecting the
device to a computer.
Kvaser AB, Mölndal, Sweden — www.kvaser.com
Kvaser U100P-X2 User’s Guide 5 (22)
2 Introduction
This section will describe the functions and features of the Kvaser U100P-X2.
2.1 Welcome to Kvaser U100P-X2
Figure 1: Kvaser U100P-X2
Kvaser U100P-X2 is a small, yet powerful, CAN to USB interface. It provides
real-time transmission and reception of standard and extended CAN messages on
the bus with a high timestamp precision, and is compatible with applications that
use Kvaser’s CANlib.
This guide applies to Kvaser U100P-X2 devices using at least firmware and driver
versions listed in Table 1. For minimum compatible firmware and driver versions of
Kvaser U100P-X2 see Table 6 on Page 14.
Device Product Number Firmware Driver (Windows/Linux)
Kvaser U100P-X2 73-30130-01270-7 v3.24 v5.36 (kcany/mhydra)
Table 1: Firmware and driver versions needed to support all functionality present in
this guide.
Kvaser AB, Mölndal, Sweden — www.kvaser.com
Kvaser U100P-X2 User’s Guide 6 (22)
2.2 Major features of Kvaser U100P-X2
•USB CAN interface.
•Powered through the USB connector.
•Supports CAN FD, up to 8 Mbit/s (with correct physical layer implementation).
•Supports both 11-bit (CAN 2.0A) and 29-bit (CAN 2.0B active) identifiers.
•Supports silent mode for analysis tools – listen to the bus without interfering.
•Lightweight robust housing made of glass fibre reinforced polyamide
overmolded with TPE.
•Intuitive LED UI.
•Reinforced galvanic isolation, design validated with 5000 VAC rms applied for
60 s.
•Industrial grade temperature range, −40 ◦C to +85 ◦C.
•20 000 msg/s, each timestamped with a resolution of 1 µs.
•Kvaser MagiSync – automatic time synchronization (see Section 3.3, Kvaser
MagiSync, on Page 8 for more details).
•Fully compatible with applications written for other Kvaser CAN hardware
with Kvaser CANlib.
•Support for SocketCAN.
•Fully compatible with J1939, CANopen, NMEA 2000 R
and DeviceNet.
•IP67 rated housing.
Kvaser AB, Mölndal, Sweden — www.kvaser.com
Kvaser U100P-X2 User’s Guide 7 (22)
3 Kvaser U100P-X2 hardware
In this section you can read more about the CAN channels, power supply and LED
indicators.
3.1 Hardware installation
The Kvaser U100P-X2 may be inserted in any free USB socket on the host
computer. You do not need to switch the power off before inserting or removing the
device. For the Kvaser U100P-X2 to communicate with the host computer, a
compatible version of the Kvaser driver and firmware must be installed.
The driver is installed by running the file
kvaser_drivers_setup.exe
. For
instructions on how to update the firmware, see Section 3.9, Updating the
firmware, on Page 14. The latest version of the driver and firmware can be
downloaded from www.kvaser.com/download.
The firmware is downloaded and installed directly on the Kvaser U100P-X2 and the
driver is installed on the host computer. After the driver has been installed on the
host computer, the firmware may then be downloaded and installed on the Kvaser
U100P-X2.
3.2 USB connection
The USB connector for the Kvaser U100P-X2 is a standard USB type “A” connector
(see Figure 2).
Figure 2: A standard USB type “A” connector.
Connect the device to your computer using any high quality USB 2.0 certified
cable. The maximum total USB cable length is 5 m (∼16 ft).
Kvaser AB, Mölndal, Sweden — www.kvaser.com
Kvaser U100P-X2 User’s Guide 8 (22)
As USB cables become longer they are more sensitive to EMI,
because they make a longer antenna that can pick up more
noise. These issues can be mitigated by using higher quality
cables with better shielding. Thicker cables tend to be better than
thin ones, and braided shielding tends to be more reliable than
only foil. Furthermore, longer cables may introduce signal
degradation and timing issues that, if necessary, can be mitigated
using shorter cable segments combined with hubs that amplify
the signal and handle delays on a per-cable basis.
3.3 Kvaser MagiSync
Time synchronization is needed to achieve accurate and precise time stamping
between several host computer-to-bus interfaces connected to one host computer.
Since each host computer-to-bus interface uses its on-board clock to set the time
stamps.
Kvaser MagiSync is an innovative way to synchronize several different Kvaser USB
interfaces. You do not need external cables - you get instant synchronisation when
you connect the MagiSync enabled Kvaser USB device.
Figure 3: An example setup where all devices are synchronized via MagiSync.
For this to work the Kvaser USB interfaces must reside on the same USB root hub.
If they do not they will not be synchronized, see Figure 3 and Figure 4 on Page 9.
Usually, a computer has a USB controller with one root hub in a computer. If you
use that one, you do not need an external USB hub to get your Kvaser Devices
synchronized. The easiest way to verify the setup is to view Synchronized
Hardware in the Device Tree of “Kvaser Device Guide” in your computer’s control
Kvaser AB, Mölndal, Sweden — www.kvaser.com
Kvaser U100P-X2 User’s Guide 9 (22)
Figure 4: Not all devices are synchronized via MagiSync in this setup.
panel. If all your hardware is placed in one Kvaser MagiSync Group, then you are
ready to go.
When connected correctly, all units are synchronized achieving a high precision
virtual clock accurate to the microsecond.
3.4 CAN connection
The Kvaser U100P-X2 has one CAN channel.
The CAN connector for the Kvaser U100P-X2 is the 5-pole M12 plug (see Figure 5)
which has the pinning described in Table 2.
Figure 5: M12 5-pole CAN connector.
M12 pin number Function
1 Shield
2 Not connected
3 GND
4 CAN_H
5 CAN_L
Table 2: M12 5-pole pin configuration.
Kvaser AB, Mölndal, Sweden — www.kvaser.com
Kvaser U100P-X2 User’s Guide 10 (22)
Figure 6: M12 5-pole CAN connector pinout.
3.5 CAN bus termination
Every CAN bus must be terminated with a 120 Ohm resistor at each end of the
bus. The Kvaser U100P-X2 does not contain any CAN bus termination, because
their inclusion could cause severe disturbance in a system which is already
correctly terminated.
For laboratory or testing use, the exact value of the termination resistors is not
always critical. Sometimes a single terminator is sufficient. For production, proper
termination is essential. If you see error frames on the bus, you should check the
termination.
To save yourself a lot of trouble, always terminate the CAN
bus properly.
3.6 Power supply
The Kvaser U100P-X2 is powered through the USB connector. Make sure the USB
power source can supply enough current (500 mA). If using a USB hub, choose an
externally powered one to be safe.
Kvaser AB, Mölndal, Sweden — www.kvaser.com