Kyoto Kagaku MW45 User manual

Caution
Do not mark on the model and other
components with pen nor leave printed
materials contacted on surface.
Ink marks on the models cannot be
removed.
MW45
Nasopharyngeal Swab Collection Simulator
Contents
Before Use······················· P.1
Preparation··················· P.2~3
Training session················ P.4
After training·················· P.5
Instruction
Manual
Manufacturer's note
Thank you for buying our MW45 Nasopharyngeal Swab Collection Simulator. This model simulates the safe
collection of samples from nasal cavity and phalynx. This simulator allows to check whether the simulated
throat swab has been properly collected. This simulator also allows repetitive training about the right angle
and depth of swabs to nasal cavity and phalynx.
Please read
Please do not use this model outside of it's original purpose. Please be reminded that the manufacturer
is not responsible for the unlikely damage or accidents by the way of use not written in this
instruction.
https://youtu.be/XVj6Pv5fixI
Movie Site
English Site

1
Before use Set includes
注意
Handle the manikin and the components
with care.
Be sure not to drop or add shock to the manikin
and its components. The product uses special
resins and materials and such shock may cause
irreparable damage to the product.
The color on its surface may change
over time, however, this should not
affect the quality of its performance.
Do not let ink from pens, newspapers,
this manual or other sources come into
contact with the manikin, as they
cannot be cleaned off the manikin skin.
Do not write on the model with
ballpoint pen or felt-tip pen.
Storage in a dark, cool and dry space
will help prevent the skin colors from
fading and the product from deforming.
The manikin skin may be cleaned with
a wet cloth using mildly soapy water or
diluted detergent if necessary. In case
the manikin is not clean enough, alcohol
can be used. Do NOT use organic solvent
such as thinner.
Set includes
Before you start, please ensure that you have all
components listed below.
a. Main model・・・・・・・・・・・・・・・・・・1
b. Cross Sectional Model・・・・・・・1
Replacement pad ・・・・・・・・・・・・6
(Already set in the main model)
c. Syringe(10ml)・・・・・・・・・・・・・1
d. Disposable cup(200ml)・・・・・・1
e. Swabs for Coloring(set of 10)
Instruction manual
d
a
c
e
b

2
Preparation of replacement pads and
how to replace
The replacement pad for the nasal cavity is already set at the time of delivery. This pad is to
be replaced if necessary. ※If pad is incorrectly set, samples cannot be confirmed during
training.
1)The face skin can be removed by detaching both left and right ears. Pull the
skin towards you.
2) After removing the nasal cavity part, you can see the replacement pad. Check whether
the pad is set properly. In case the pad is deformed or it is not absorbing enough liquids,
please replace it with new pads.
3)By pressing the tube which is on the back side of the neck, the storage
case for replacement pad comes forward. After replacing with new pads, set
the nasal cavity part and face skin back to its original position.
Preparation
Preparation of replacement pads

3
Preparation for simulated throat swab
1)Simulatedthroatswabinbluecolorcanbemadebypouringabout100mlofwatertothe
disposablecup,stirtheswabforcoloringseveraltimes.
●Caution
・If allowed to air-dry, the coloring swabs can be reused multiple times.
・Please handle the simulated throat swabs with care because of the possibility
of permanent stain damage to clothes.
2)Pour 10ml of simulated throat sample into the syringe,connect the tube attached
to the back of the model, inject the simulated throat sample slowly, and the
preparation is done.
●Caution
Do not pour more than 10ml of simulated throat sample. The replacement pad
cannot absorb the simulated throat sample, which leads to leakage.
Preparation
Preparation for simulated
throat swab

4
正しい挿入角度
不適切な挿入角度
模擬
Training
Training Item
・Nasopharyngeal Sample Collection
By inserting the cotton swab in proper angle and depth, the the tip of the cotton
swab reaches the replacement pad of simulated throat sample, which allows trainee to
confirm the cotton swab reached the proper collection area. The shape of the left and
right nasal cavities are different, so two different angles of insertion can be
practiced.
〇×
Right Left
The shape of the left and right
nasal cavities are different
・Pharyngeal swab collection
Successful cotton swab
after taking simulated
throat sample.
Training to insert cotton swab to the oral
cavity while using tongue depressor can be
practiced.
Training
Nasopharyngeal Swab Collection

5
After training
1)After training,
discharge the simulated
throat sample inside the
tube using the syringe
attached. Dispose of
the simulated throat
sample.
2)By following the
procedures in page 2, pull out
the replacement pad, squeeze
the simulated throat swab, and
restore the pad in the
original position.
●Caution
The replacement pad can be stored in the condition which it was received.
However, it is preferable to remove the remaining water after use, because if
new simulated throat swab are inserted without the removal, it can lead to
leakage.
Training
After Training

6
Replacement parts
11426-010 Replacement pad for MW45(a set of 5)
Caution
Do not mark on the model and other
components with pen nor leave printed
materials contacted on surface.
Ink marks on the models cannot be
removed.
Code number Name
11426-010 Replacement pad for MW45(a set of 5)
11402-010 Swabs for coloring Blue(a set of 10)
2020.05
11426-010 Replacement pad for
MW45(a set of 5)
11402-010 Swabs for coloring
Blue for MW45(a set of 10)
Other Kyoto Kagaku Science Education Product manuals
Popular Science Education Product manuals by other brands

Life form
Life form LF01027U instruction manual

KOKEN
KOKEN LM-101D instruction manual

PASCO
PASCO //control.Node Product guide

laerdal
laerdal Little Anne Directions for use

Horizon Fuel Cell Technologies
Horizon Fuel Cell Technologies Renewable Energy Education Set Assembly guide

zSpace
zSpace zView Assembly instructions