manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Landscape Forms
  6. •
  7. Lighting Equipment
  8. •
  9. Landscape Forms Torres User manual

Landscape Forms Torres User manual

Tools Required
•Safety glasses
•Hex key 5/32” for nut covers, 5mm for bracket to tenon mount, 4mm for luminaire cover
•Socket wrench, 17mm
•Wrenches, 1-1/8”
•Screwdrivers, Phillips and straight blade
•Wiring tools and connectors
•Proper personnel, crane or lift for hoisting unit onto anchors
•Level
•Dimming control, if required.
•Twist lock photo eye, if required
Landscape Forms is not responsible for site preparation and
footings. Refer to the installation guide for the Torres area light
anchor kit for installing the anchor bolts.
WARNING! Pole mounted luminaires must be attached either
before or immediately after pole installation. Failure to do so may
cause vibration damage to the pole and will void the pole
warranty.
CAUTION! This unit is heavy. To avoid injury or damage to the
finish, we recommend using a crane or lift for hoisting the unit
onto the anchors. Do not lift unit by the luminaire head.
ASSEMBLE WITH CARE! To protect this finish during assembly, place
unwrapped powdercoated parts on packaging foam or other non-marring
surface. Do not place or slide powdercoated parts on concrete or other
hard or textured surface –this will damage the finish causing rust to occur.
Use touch-up paint on any gouges in the finish caused by assembly tools.
Installation Guide
Torres Area Light
www.landscapeforms.com Ph: 800.521.2546
Date: February 18, 2020
Page 1 of 4
4X -Nut cover with
1/4-20 x 5/8” button
head cap screw
Cover plate
assembly (optional)
Pole with base plate
12ft 16ft 20ft 25ft
Included components
14ft
No motion sensor With motion sensor
AH236
AH256
AH236
AH256
Double mount
With Twist-lock
Single mount
No Twist-lock
Single mount
With Twist-lock
Double mount
No Twist-lock
4X –3/8”
washer
8X –M10 x
30mm
Set screw
4X –M10 x 30mm
Hex head cap
screw
3X –M6 x 30mm
Socket button
head cap screw
3X –1/4” sealing
washer
Twist lock receptacle,
optional
Shorting cap for
Twist lock,
optional
For poles with twist lock
Intermediate
mount bracket
Intermediate
mount cover
2X –M10 x 160mm
hex head screw
2X –
3/8 washer
3X –
M6 x 16mm
BHCS
For intermediate mount luminaire
FSIR-100
Wattstopper
controller (optional)
Installation Guide www.landscapeforms.com Ph: 800.521.2546
Page 2 of 4
ASSEMBLY AND INSTALLATION PROCEDURE:
*refer to the Torres Area Light Anchor kit installation guide
for setting the pole anchors. Concrete should be fully cured
before installing the pole.*
BASIC INSTALLATION STEPS:
1. Attach bracket to pole.
2. Attach luminaire to bracket.
3. Connect line-in voltage wires to driver.
4. Attach lid to luminaire.
5. Install pole assembly onto previously installed anchors.
INSTALLATION INSTRUCTIONS FOR MOUNTING LUMINAIRES AT THE TOP OF THE POLE:
1. Route the line voltage wires (provided by others) up the pole and through the opening at the top of the pole. See
Fig. 5.
2. Route the wires through the luminaire mounting bracket, see Fig 5.
3. Attach the mounting bracket to the pole using (8) M10 x 30mm set screws. Tighten set screws using a 5mm hex
key. See Fig. 5.
4. Using a 4mm hex key, remove (3) M6 x 30mm button head screws and sealing washers to remove the luminaire
cover. See Fig. 8. Set aside, retain hardware.
5. Attach luminaire to mounting bracket using (4) M10 x 30mm hex head bolts and 3/8” washers. Ensure wires are
routed through the relief in the luminaire housing and are not pinched. See Fig. 6 and Fig. 7.
6. Connect line voltage wires to driver. See Fig. 7. Take precautions to provide strain relief on supply wires.
7. Reattach luminaire cover with (3) M6 button head screws and sealing washers. See Fig. 8.
INSTALLATION INSTRUCTIONS FOR MOUNTING AN INTERMEDIATE HEIGHT LUMINAIRE:
1. Using 17mm socket wrench, attach intermediate mount bracket to pole with (2) M10 x 160mm hex head bolts
and washers. See Fig. 9.
2. Install intermediate bracket cover plate with (3) M6 x 16mm button head screws. Tighten with a 4mm hex key.
See Fig. 10.
3. Using a 4mm hex key, remove (3) M6 x 30mm button head screws and sealing washers to remove the luminaire
cover. See Fig. 12. Set aside, retain hardware.
4. Attach luminaire to mounting bracket using (4) M10 x 30mm hex head bolts and 3/8” washers. Ensure wires are
routed through the relief in the luminaire housing and are not pinched. See Fig. 11.
5. Connect line voltage wires to driver. See Fig. 7. Take precautions to provide strain relief on supply wires.
6. Reattach luminaire cover with (3) M6 button head screws and sealing washers. See Fig. 12.
INSTALLATION OF POLE:
1. Install pole with hex nuts and washers, see Fig. 2.
2. Install nut covers, Fig. 3 or optional cover plate, Fig. 4.
Torres Area Light
Fig. 2 –Install pole
Fig. 1 –Pole orientation
SIDEWALK
HAND HOLE
ORIENTED ON
SIDE OPPOSITE OF
LUMINAIRE
[457mm]
18”
SETBACK
Fig. 3 –Install nut covers
Fig. 4 –Install cover plates
Date: February 18, 2020
Installation Guide www.landscapeforms.com Ph: 800.521.2546
Page 3 of 4
Fig.5 –Attach luminaire bracket
M10 x 30mm
SET SCREWS
Torres Area Light
Fig. 6 –Attach luminaire
M10 x 30mm
HEX HEAD CAP
SCREWS WITH
WASHERS
Fig. 8 –Attach luminaire cover
M10 x 30mm
SBHCS WITH
SEALING
WASHERS
Fig. 9 –Attach bracket for
intermediate mount luminaire
M10 x 160mm
HEX HEAD
SCREWS WITH
WASHERS
Fig. 10 –Attach bracket for
intermediate mount luminaire
M6 x 16mm
BHCS
3X
Fig. 12 –Attach luminaire cover
M10 x 30mm
SBHCS WITH
SEALING
WASHERS
Fig. 7 –Route electrical supply wires
Fig. 11 –Attach intermediate mount luminaire
M10 x 30mm
HEX HEAD CAP SCREWS
WITH WASHERS
Date: February 18, 2020
Installation Guide www.landscapeforms.com Ph: 800.521.2546
Page 4 of 4
Torres Area Light
PROCEDURE FOR WIRING TORRES LED LUMINAIRES:
The wiring schematics are to be used to connect the unit to line voltage. It is the responsibility of the installer to make sure that all connections
are made in accordance with the NEC and local building codes. Connection hardware not included.
Install the shorting cap to test the light:
Units that have a twist lock receptacle installed must have a shorting cap (included) installed in order to test the light. Alternatively, a photo
control (not included) could be installed and the eye portion covered to activate the luminaire.
Hook up to power source:
Connect the line voltage wires at the bottom of the pole. Refer to wiring diagrams for incoming power supply requirements.
Fig. 13 –Install optional twist
lock receptacle to top cap
SHORTING
CAP
#6-32 x 1-1/4”
FLAT HEAD
MACHINE SCREW
TWIST-LOCK
RECEPTACLE
TORRES WIRING DIAGRAM: WITH MOTION SENSOR
TORRES WIRING DIAGRAM: NO MOTION SENSOR
Date: February 18, 2020

Other Landscape Forms Lighting Equipment manuals

Landscape Forms FGP User manual

Landscape Forms

Landscape Forms FGP User manual

Landscape Forms Torres User manual

Landscape Forms

Landscape Forms Torres User manual

Popular Lighting Equipment manuals by other brands

Weda B600 Service manual

Weda

Weda B600 Service manual

optonica 237 user manual

optonica

optonica 237 user manual

ASTRO ARRAN manual

ASTRO

ASTRO ARRAN manual

Chauvet Line Dancer LED user manual

Chauvet

Chauvet Line Dancer LED user manual

Generay BA-VMount user manual

Generay

Generay BA-VMount user manual

Easylife EL5868 instruction manual

Easylife

Easylife EL5868 instruction manual

Eaton SafeLite manual

Eaton

Eaton SafeLite manual

Monacor RL-6 quick guide

Monacor

Monacor RL-6 quick guide

Ledj HBR 1D user manual

Ledj

Ledj HBR 1D user manual

Maretti SALERNO DOWNLIGHTER 10.6370 Series instruction manual

Maretti

Maretti SALERNO DOWNLIGHTER 10.6370 Series instruction manual

Philips RS772B manual

Philips

Philips RS772B manual

THELIGHT 4LONG user manual

THELIGHT

THELIGHT 4LONG user manual

NJD Electronics SPECTRE user guide

NJD Electronics

NJD Electronics SPECTRE user guide

Insta Tec 2131 quick start guide

Insta

Insta Tec 2131 quick start guide

brennenstuhl OL 1600 operating instructions

brennenstuhl

brennenstuhl OL 1600 operating instructions

Lutron Electronics Sunnata ST-PRO-N manual

Lutron Electronics

Lutron Electronics Sunnata ST-PRO-N manual

Bouclair 9401448 Assembly instructions

Bouclair

Bouclair 9401448 Assembly instructions

IOTA ILBLP SP HE SD LC CW instruction manual

IOTA

IOTA ILBLP SP HE SD LC CW instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.