Lanner ICS-P371A User manual

LEC-6041 User Manual
1
ICS-P371 User Manual
Preliminary Draft
Version: 1.0
Date of Release:2023-01-19
Industrial Communication Platforms
Next Generation Industrial Cyber Security Solutions

ICS-P371 User Manual
2
This manual describes the overview of the various functionalities of this product, and the information you
need to get it ready for operation. It is intended for those who are:
-responsible for installing, administering and troubleshooting this system or Information Technology
professionals.
-assumed to be qualified in the servicing of computer equipment, such as professional system integrators,
or service personnel and technicians.
The latest version of this document can be found on Lanner’s official website, available either through the
product page or through the Lanner Download Center page with a login account and password.
The icons are used in the manual to serve as an indication of interest topics or important messages.
Icon
Usage
This mark indicates that there is something you should pay special
attention to while using the product.
This mark indicates that there is a caution or warning and it is
something that could damage your property or product.
To obtain additional documentation resources and software updates for your system, please visit the Lanner
Download Center. As certain categories of documents are only available to users who are logged in, please
be registered for a Lanner Account at http://www.lannerinc.com/ to access published documents and
downloadable resources.
In addition to contacting your distributor or sales representative, you could submit a request at our Lanner
Technical Support and fill in a support ticket to our technical support department.
Your feedback is valuable to us, as it will help us continue to provide you with more accurate and relevant
documentation. To provide any feedback, comments or to report an error, please email
[email protected]m. Thank you for your time.
Note or Information
Warning or Important

ICS-P371 User Manual
3
Taiwan Corporate Headquarters
Lanner Electronics Inc.
7F, No.173, Sec.2, Datong Rd.
Xizhi District, New Taipei City 22184,
Taiwan
立端科技股份有限公司
221 新北市汐止區
大同路二段 173 號7樓
T: +886-2-8692-6060
F: +886-2-8692-6101
China
Beijing L&S Lancom Platform Tech. Co., Ltd.
Guodong LOFT 9 Layer No. 9 Huinan Road,
Huilongguan Town, Changping District, Beijing
102208 China
T: +86 010-82795600
F: +86 010-62963250
E: service@ls-china.com.cn
USA
Lanner Electronics Inc.
47790 Westinghouse Drive
Fremont, CA 94539
T: +1-855-852-6637
F: +1-510-979-0689
E: sales_us@lannerinc.com
Canada
Lanner Electronics Canada Ltd
3160A Orlando Drive
Mississauga, ON
L4V 1R5 Canada
T: +1 877-813-2132
F: +1 905-362-2369
E: sales_ca@lannerinc.com
Europe
Lanner Europe B.V.
Wilhelmina van Pruisenweg 104
2595 AN The Hague
The Netherlands
T: +31 70 701 3256
E: sales_eu@lannerinc.com

ICS-P371 User Manual
4
This document is copyrighted © 2023 by Lanner Electronics Inc. All rights are reserved. The original manufacturer
reserves the right to make improvements to the products described in this manual at any time without notice. No part
of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior
written permission of the original manufacturer. Information provided in this manual is intended to be accurate and
reliable. However, the original manufacturer assumes no responsibility for its use, nor for any infringements upon the
rights of third parties that may result from such use.
Intel® and Intel® Atom® are trademarks of Intel Corporation or its subsidiaries in the U.S. and/or other countries.
Microsoft Windows and MS-DOS are registered trademarks of Microsoft Corp.
All other product names or trademarks are properties of their respective owners.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Caution
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Note
1. An unshielded-type power cord is required to meet FCC emission limits and to prevent interference to the nearby
radio and television reception. It is essential that only the supplied power cord be used.
2. Use only shielded cables to connect I/O devices to this equipment.
3. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
Important
1. Operations in the 5.15-5.25GHz band are restricted to indoor usage only.
2. This device meets all the other requirements specified in Part 15E, Section 15.407 of the FCC Rules.

ICS-P371 User Manual
5
Follow these guidelines to ensure general safety:
Keep the chassis area clear and dust-free during and after installation.
Do not wear loose clothing or jewelry that could get caught in the chassis. Fasten your tie or scarf and roll up your
sleeves.
Wear safety glasses if you are working under any conditions that might be hazardous to your eyes.
Do not perform any action that creates a potential hazard to people or makes the equipment unsafe.
Disconnect all power by turning off the power and unplugging the power cord before installing or removing a chassis
or working near power supplies
Do not work alone if potentially hazardous conditions exist.
Never assume that power is disconnected from a circuit; always check the circuit.
Suivez ces consignes pour assurer la sécuritégénérale :
Laissez la zone du châssis propre et sans poussière pendant et après l’installation.
Ne portez pas de vêtements amples ou de bijoux qui pourraient être pris dans le châssis. Attachez votre cravate ou
écharpe et remontez vos manches.
Portez des lunettes de sécurité pour protéger vos yeux.
N’effectuez aucune action qui pourrait créer un danger pour d’autres ou rendre l’équipement dangereux.
Coupez complètement l’alimentation en éteignant l’alimentation et en débranchant le cordon d’alimentation avant
d’installer ou de retirer un châssis ou de travailler à proximité de sources d’alimentation.
Ne travaillez pas seul si des conditions dangereuses sont présentes.
Ne considérez jamais que l’alimentation est coupée d’un circuit, vérifiez toujours le circuit. Cet appareil génère, utilise
et émet une énergie radiofréquence et, s’il n’est pas installé et utilisé conformément aux instructions des fournisseurs
de composants sans fil, il risque de provoquer des interférences dans les communications radio.
There is risk of Explosion if Battery is replaced by an incorrect type.
Dispose of used batteries according to the instructions.
Installation only by a skilled person who knows all Installation and Device Specifications which are to be applied.
Do not carry the handle of power supplies when moving to another place.
Please conform to your local laws and regulations regarding safe disposal of lithium BATTERY.
Disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery can result in an explosion.
Leaving a battery in an extremely high temperature surrounding environment can result in an explosion or the
leakage of flammable liquid or gas.
A battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid
or gas.
Risque d’explosion si la pile est remplacée par une autre d’un mauvais type.
Jetez les piles usagées conformément aux instructions.
L’installation doit être effectuée par un électricien formé ou une personne formée à l’électricité connaissant toutes
les spécifications d’installation et d’appareil du produit.
Ne transportez pas l’unité en la tenant par le câble d’alimentation lorsque vous déplacez l’appareil.
Electrical equipment generates heat. Ambient air temperature may not be adequate to cool equipment to acceptable
operating temperatures without adequate circulation. Be sure that the room in which you choose to operate your
system has adequate air circulation.
Ensure that the chassis cover is secure. The chassis design allows cooling air to circulate effectively. An open chassis
permits air leaks, which may interrupt and redirect the flow of cooling air from internal components.
Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. ESD damage occurs when
electronic components are improperly handled and can result in complete or intermittent failures. Be sure to follow
ESD-prevention procedures when removing and replacing components to avoid these problems.
Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. If no wrist strap is available, ground
yourself by touching the metal part of the chassis.
Periodically check the resistance value of the antistatic strap, which should be between 1 and 10 megohms (Mohms).

ICS-P371 User Manual
6
L’équipement électrique génère de la chaleur. La température ambiante peut ne pas être adéquate pour refroidir
l’équipement à une température de fonctionnement acceptable sans circulation adaptée. Vérifiez que votre site
propose une circulation d’air adéquate.
Vérifiez que le couvercle du châssis est bien fixé. La conception du châssis permet à l’air de refroidissement de bien
circuler. Un châssis ouvert laisse l’air s’échapper, ce qui peut interrompre et rediriger le flux d’air frais destiné aux
composants internes.
Les décharges électrostatiques (ESD) peuvent endommager l’équipement et gêner les circuits électriques. Des dégâts
d’ESD surviennent lorsque des composants électroniques sont mal manipulés et peuvent causer des pannes totales
ou intermittentes. Suivez les procédures de prévention d’ESD lors du retrait et du remplacement de composants.
Portez un bracelet anti-ESD et veillez à ce qu’il soit bien au contact de la peau. Si aucun bracelet n’est disponible,
reliez votre corps àla terre en touchant la partie métallique du châssis.
Vérifiez régulièrement la valeur de résistance du bracelet antistatique, qui doit être comprise entre 1 et 10 mégohms
(Mohms).
Mounting Installation Precaution
Do not install and/or operate this unit in any place that flammable objects are stored or used in.
If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may
be greater than room ambient. Therefore, consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
Installation of the equipment (especially in a rack) should consider the ventilation of the system’s intake (for taking
chilled air) and exhaust (for emitting hot air) openings so that the amount of airflow required for safe operation of
the equipment is not compromised.
To avoid a hazardous load condition, be sure the mechanical loading is even when mounting.
Consideration should be given to the connection of the equipment to the supply circuit and the effect that
overloading of the circuits might have on over-current protection and supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable earthing should be maintained. Particular attention should be given to supply connections other than direct
connections to the branch circuit (e.g., use of power strips).
Installation & Operation:
This equipment must be grounded. The power cord for product should be connected to a socket-outlet with earthing
connection.
Cet équipement doit être mis àla terre. La fiche d'alimentation doit être connectée àune prise de terre correctement
câblée
Suitable for installation in Information Technology Rooms in accordance with Article 645 of the National Electrical
Code and NFPA 75.
Peut être installédans des salles de matériel de traitement de l'information conformément àl'article 645 du National
Electrical Code et àla NFPA 75.
The machine can only be used in a restricted access location and must be installed by a skilled person.
Les matériels sont destinés àêtre installés dans des EMPLACEMENTS À ACCÈS RESTREINT.
Warning
Class I Equipment. This equipment must be earthed. The power plug must be connected to a properly wired earth
ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts.
“Product shall be used with Class 1 laser device modules.”
Avertissement
Équipement de classe I. Ce matériel doit être relié à la terre. La fiche d’alimentation doit être raccordée à une prise de
terre correctement câblée. Une prise de courant mal câblée pourrait induire des tensions dangereuses sur des parties
métalliques accessibles.
“Le produit doit être utilisé avec des modules de dispositifs laser de classe 1.”

ICS-P371 User Manual
7
Before turning on the device, ground the grounding cable of the equipment. Proper grounding (grounding) is very
important to protect the equipment against the harmful effects of external noise and to reduce the risk of electrocution
in the event of a lightning strike. To uninstall the equipment, disconnect the ground wire after turning off the power. A
ground wire is required and the part connecting the conductor must be greater than 4 mm2 or 10 AWG.
Avant d’allumer l’appareil, reliez le câble de mise à la terre de l’équipement à la terre.
Une bonne mise à la terre (connexion à la terre) est très importante pour protéger l’équipement contre les effets
néfastes du bruit externe et réduire les risques d’électrocution en cas de foudre.
Pour désinstaller l’équipement, débranchez le câble de mise à la terre après avoir éteint l’appareil.
Un câble de mise à la terre est requis et la zone reliant les sections du conducteur doit faire plus de 4 mm2 ou 10
AWG.
Loosen the screw of the earthing point.
Connect the grounding cable to the ground.
The protection device for the power source must provide 30 A current.
This protection device must be connected to the power source before power.
The cable hould 16 AWG
Desserrez la vis du terminal de mise àla terre.
Branchez le câble de mise àla terre àla terre.
L’appareil de protection pour la source d’alimentation doit fournir 30 A de courant.
Cet appareil de protection doit être branché à la source d’alimentation avant
l’alimentation.
Le câble doit 16 AWG

ICS-P371 User Manual
8
Package Content...........................................................................................................................9
Ordering Information ...................................................................................................................9
Optional Accessories ....................................................................................................................9
System Specifications.................................................................................................................10
Top & Front Panel.......................................................................................................................11
Motherboard Information..........................................................................................................12
Opening the Chassis ...................................................................................................................16
Installing the SATA Storage (Optional).......................................................................................18
Installing the LTE/5G Module (Optional)....................................................................................20
Installing the Wi-Fi Module (Optional).......................................................................................24
Installing the IPMI Module (Optional)........................................................................................26
Installing the SD Card .................................................................................................................27
DIN Rail Mounting (Optional).....................................................................................................28
BIOS Setup..................................................................................................................................29
Main Page...................................................................................................................................30
Advanced Page ...........................................................................................................................31
Warranty Policy ..........................................................................................................................62

ICS-P371 User Manual
9
ICS-P371 Series is empowered by Intel® Atom™ X6211E/X6413E/X6425E CPU (formerly Elkhart Lake) for
enhanced IoT platform and high processing performance. As the next-generation industrial cybersecurity
gateway, ICS-P371 possesses several key hardware features, including advanced LAN bypass technology,
Chassis Intrusion Detect, and TPM 2.0 onboard. ICS-P371 is compliant with IEC 61850-3 and IEEE 1613 and
can operate in a wide range of operating temperatures from -40°C to 70°C.
Your package contains the following items:
1x ICS-P371 Cyber Security Platform
1x Console Cable
1x 6-pin Terminal Block mating connector with screws for power input
SKU No.
Main Features
ICS-P371A
IEC 61850-3 Wide Temp Industrial Cyber Security Gateway with Intel® Atom®
X6211E processor, 6x RJ45, 2x SFP LAN Ports, LTE/5G-Sub6, and SATA storage
expansion
ICS-P371B
IEC 61850-3 Wide Temp Industrial Cyber Security Gateway with Intel® Atom®
X6413E processor, 6x RJ45, 2x SFP LAN Ports, LTE/5G-Sub6, and SATA Storage
expansion
ICS-P371C
IEC 61850-3 Wide Temp Industrial Cyber Security Gateway with Intel® Atom®
X6425E processor, 6x RJ45, 2x SFP LAN Ports, LTE/5G-Sub6, and SATA Storage
expansion
ICS-P371D
IEC 61850-3 Wide Temp Industrial Cyber Security Gateway with Intel® Atom®
X6211E processor, 6x RJ45, 2x SFP LAN Ports, LTE/5G-Sub6 and SATA storage
expansion, and Wi-Fi and IPMI module expansion
ICS-P371E
IEC 61850-3 Wide Temp Industrial Cyber Security Gateway with Intel® Atom®
X6413E processor, 6x RJ45, 2x SFP LAN Ports, LTE/5G-Sub6 and SATA Storage
expansion, and Wi-Fi and IPMI module expansion
ICS-P371F
IEC 61850-3 Wide Temp Industrial Cyber Security Gateway with Intel® Atom®
X6425E processor, 6x RJ45, 2x SFP LAN Ports, LTE/5G-Sub6 and SATA Storage
expansion, and Wi-Fi and IPMI module expansion
Model No.
Description
HDD/SSD Kit
2.5” Drive Bay Kit w/ brackets, screws, SATA/power cables
SATA Kit
SATA Kit w/ thermal pad, screws, sink
LTE Kit
LTE Module Kit w/ thermal pad, screws, internal antenna cables, external antennas
5G Kit
5G Module Kit w/ thermal pads, screws, internal antenna cables, external antennas
Wi-Fi Kit
Wi-Fi Module Kit w/ thermal pad, screws, internal antenna cables, external antennas
Wallmount Kit
Wall Mount Kit w/ brackets, and screws

ICS-P371 User Manual
10
Processor System
CPU
Intel Atom® X6211E/X6413E/X6425E
Frequency
Atom X6211E: 1.3 GHz;
Atom X6413E: 1.5 GHz;
Atom X6425E: 2.0 GHz
Core Number
Atom X6211E: 2 cores;
Atom X6413E/X6425E: 4 cores
BIOS
AMI SPI Flash BIOS
Chipset
SoC
Fanless
Yes
System Memory
Technology
DDR4, non ECC & IB-ECC
Max. Capacity
32 GB
Socket
1x 260-pin SODIMM
Graphic
Controller
N/A
Interface
1x Internal DP Pin-header
Ethernet
Controller
Intel® i226T/i210IS
Speed
RJ45: 100M/1G/2.5Gbps, SFP: 1 Gbs
Interface
6x RJ45, 2x SFP;
2x IPMI Ports (By SKU)
Bypass
1 Pair Bypass by RJ45
Storage
Type
SATA
Installation
1x 2.5” drive bay;
1x M.2 M-Key 2242
Type
SD
Installation
1x Micro SD Reader
Expansion
M.2
1x M.2 B-Key 3042/3050/3052 for LTE/5G Sub6
module, with dual Nano-SIM;
1x M.2 E-Key for Wi-Fi module (By SKU)
I/O
Serial Port
2x RS-232, DB9 Male
DIO
2x Isolated DI;
2x Isolated DO
USB Port
1x USB 3.0;
1x USB 2.0 Type A
Power-On/Reset Button
1x Reset Button
LED
System Status, Ethernet Status, Programmable LEDs
Watchdog Timer
Watchdog timer 256 level time interval system reset,
software programmable
Power
Power Supply Voltage
Dual +12~48Vdc
Connector
Phoenix contact 6-pin connector with lock
Environment
Operating Temperature
-40 ~ 70ºC
Storage Temperature
-40 ~ 85ºC
Relative Humidity
5% ~ 95%, Non-Condensing
Mechanical
Dimension (WxHxD)
87 x 196 x 180 mm
Construction
Aluminum & SGCC
Weight
2.2 kg
Mounting
DIN rail or Wall mount (Optional)
Driver Support
Microsoft Windows
Windows 10/11 IoT
Linux
Linux Kernel 2.6X or later
(Depends on Intel® formal release)
Certification
FCC/CE Class A, UL (IEC-62368), C1D2 IEC 61850-3, IEEE 1613

ICS-P371 User Manual
11
No.
Description
T1
DIO
2x 4-Pin Terminal Block for 2x Isolated DI (Dry & Wet for Sink/Source) & 2x
Isolated DO;
DI: -3~5V @ 7mA, Logical Value 0; 13~30V @ 7mA, Logical Value 1 (Design
Spec as Logical Value 0 for under 9V and 1 for above 9V)
DO: Sink DO voltage typical 24V (up to 30V) @ 200mA
T2
Grounding Hole
1x Hole for grounding cable to connect to the ground (optional)
T3
DC-in Jack
1x 6-Pin Terminal Block, +12~48Vdc power input with lock
T4
Reset Button
1x Reset Button
T5
Antennas
2x Antennas for Wi-Fi Module (optional)
No.
Description
F1
LED Indicators
Storage Status, System Status, Ethernet Status, Programmable LEDs
F2
USB Port
1x USB 3.0 Port
F3
USB Port
1x USB 2.0 Port
F4
LAN Port
6x RJ45 Ethernet Ports
F5
SFP Port
2x SFP Ports
F6
COM Port
1x RS-232, DB9 Male
F7
IPMI/Console Port
1x RJ45 IPMI Port & 1x RJ45 Console Port (By SKU)
F8
Antennas
2x Antennas for LTE/5G Module (optional)
T1
T2
T3
T4
T5
F1
F4
F5
F2
F3
F7
F6
F8

ICS-P371 User Manual
12
The block diagram indicates how data flows among components on the motherboard. Please refer to the
following figure for your motherboard’s layout design.

ICS-P371 User Manual
13
PWR1: Power Button (12~36V)
Pin
Signal
1
DC_GND
2
DC_IN
3
ALARM2
4
ALARM1
5
DC_IN
6
DC_GND
JCMOS1: RTC Reset
1-2: Clear CMOS for RTC
2-3: Clear CMOS for SRTC
Pin
Signal
1
RTC_RST#
2
NC
3
SRTC_RST#
J8: Power SMBUS Debug
Pin
Signal
1
GND
2
SMB_CLK_VR
3
SMB_DATA_VR
J18: For Program MCU (Debug / Burn in code)
ARM Programming Selection
1-2: Disable (Default)
2-3: Enable
Pin
Signal
1
+P3V3_STBY
2
PIO1_1_GPIO2
3
GND

ICS-P371 User Manual
14
J17: LTE Module GPS Select
1-2: EM7455/MV31-W/RM00Q
2-3: FN980
Pin
Signal
1
+P3V3
2
W_DIS2#_OE
3
GND
COM1
Pin
Signal
1
NC
2
NC
3
COM_RXD1_L
4
COM_RTS1_#_L
5
COM_TXD1_L
6
COM_CTS1_#_L
7
NC
8
NC
9
COM_GND
JDebug1
Pin
Signal
1
+P3V3_STBY
2
GND
3
UART_TX
4
UART_RX
JSPI1
Pin
Signal
1
SPI0_IO3_HOLD#
2
NC
3
SPI0_CS0_R#
4
+P3V3_STBY_SPI
5
SPI0_IO1_MISO_R
6
NC
7
NC
8
SPI0_CLK_R
9
GND
10
SOC_SPI_MOSI_R

ICS-P371 User Manual
15
JPW1
Pin
Signal
1
+P12V
2
GND
3
GND
4
+P5V
ESPI1
Pin
Signal
Pin
Signal
1
ESPI_CLK
2
ESPI_IO1
3
ESPI_RST#
4
ESPI_IO0
5
ESPI_CS0#
6
+P3V3
7
ESPI_IO3
8
NA
9
ESPI_IO2
10
GND
11
+P3V3_STBY
12
NC
JDebug1
Pin
Signal
1
+P3V3_STBY
2
GND
3
UART_TX
4
UART_RX

ICS-P371 User Manual
16
To reduce the risk of personal injury, electric shock, or damage to the system, please remove all power
connections to shut down the device complete. Also, please wear ESD protection gloves when conducting
the steps in this chapter.
1. Power off the system and unplug the power
cord.
2. Unscrew the four (4) screws on the system’s
top side panel. Then, remove the side metal
partition.
3. Loosen the six (6) screws on the system’s
rear and bottom panel.
Bottom Panel
Rear Panel

ICS-P371 User Manual
17
4. Turn the system upside down. Slide the
chassis cover away from the system and lift
the cover to remove.

ICS-P371 User Manual
18
The motherboard supports one M.2 M-Key for SATA storage module expansion. Please follow the
procedures for installation.
1. Power off the system and remove the
chassis cover.
2. Locate the M.2 slot on the motherboard.
Loosen the three (3) screws on metal cover
A and remove.
3. Loosen the two (2) screws on metal cover
B and remove.
4. Align the notch of the SATA storage
module with the socket key in the pin slot.
Metal Cover A
Metal Cover B
Notch
Socket Key

ICS-P371 User Manual
19
5. Insert the storage module pins at 30
degrees into the socket until it is fully
seated.
6. Push down on the module card and secure
it with one (1) screw.
7. Next, thermal pad placement. Remove the
protective film on the thermal pad
(included in the accessory pack) and
gently place on the module card.
8. Then place metal cover B over the thermal
pad, and secure with two (2) screws on the
right side.
9. Lastly, secure metal cover A back on top of metal cover B. Then place the chassis cover back and secure
with the required screws.

ICS-P371 User Manual
20
The motherboard supports one M.2 B-Key for LTE/5G module card expansion. LTE module requires two
antennas and 5G module requires four antennas. Please follow the procedures for installation.
1. Power off the system and remove the
chassis cover.
2. Locate the M.2 slot on the motherboard.
Loosen the three (3) screws on metal cover
A and remove.
3. Then, thermal pad placement. Remove the
protective film on the thermal pad (included
in the accessory pack) and gently place on
the space.
4. Align the notch of the module card with the
socket key in the pin slot.
5. Insert the module card at 30 degrees into
the socket until it is fully seated.
6. Push down on the module card and secure
it with a screw.
Metal Cover A
Socket Key
Notch
This manual suits for next models
5
Table of contents
Popular Conference System manuals by other brands

TANDBERG
TANDBERG 3000 MXP Profile Connecting guide

Elo TouchSystems
Elo TouchSystems Huddle Kit Quick installation guide

Okayo
Okayo WaveTeams product manual

AT&T
AT&T MERLIN LEGEND 555-601-010ADD System manager's guide

Polycom
Polycom EagleEye Director Setting up

Panasonic
Panasonic KX-NS500 Programming manual