Lantech IGS-0008B User manual

Lantech
IGS-0008B
8 10/100/1000T Industrial Switch
IPGS-0008B
8 10/100/1000T PoE at Industrial Switch
User Manual
V1.00
Dec-2016

Recommendation for Shielded network cables
STP cables have additional shielding material that is used to reduce external interference. The
shield also reduces the emission at any point in the path of the cable. Our recommendation is
to deploy an STP network cable in demanding electrical environments. Examples of
demanding indoor environments are where the network cable is located in parallel with
electrical mains supply cables or where large inductive loads such as motors or contactors are
in close vicinity to the camera or its cable. It is also mandatory to use an STP cable where the
power device (like IP camera) is used outdoors or where the network cable is routed outdoors.

Content
Overview.............................................................1
Introduction ..............................................................1
Packing List..............................................................2
Safety Precaution.....................................................2
Hardware Description.........................................3
Front Panel...............................................................3
Top View..................................................................4
Dimensions ..............................................................4
Wiring the Power Inputs...........................................6
LED Indicators..........................................................8
RJ-45 Pin Assignments............................................9
Cabling...................................................................11
Mounting Installation ........................................12
DIN-Rail Mounting..................................................12
Wall-Mount Plate Mounting....................................14
Hardware Installation........................................15
Installation Steps.................................................... 16

Troubleshooting................................................17

1
Overview
Introduction
The unmanaged industrial switch is a cost-effective solution and meets
the high reliability requirements demanded by industrial applications.
High-Speed Transmissions
The Industrial switch includes a switch controller that can automatically
sense transmission speeds (10/100/1000 Mbps). The RJ-45 interface
can also be auto-detected, so MDI or MDI-X is automatically selected
and a crossover cable is not required. All Ethernet ports have memory
buffers that support the store-and-forward mechanism. This assures
that data is properly transmitted.
Dual Power Inputs
To reduce the risk of power failure, the Industrial switch provides dual
power inputs. When power failure occurs, the device will automatically
switch to the secondary power input.
Flexible Mounting
The industrial switch is extremely compact and can be mounted on a
DIN-rail or a panel, so it is suitable for any space-constrained
environment. *Wall mount kit is optional.
Wide Operating Temperature
The operating temperature of the Industrial switch is in the range
between -20 ~ 60oC (standard model) or -40 ~ 75oC (wide operating
temperature model). With such a wide range, you can use the Industrial
switch in some of the harshest industrial environments that exist.
Easy Troubleshooting
LED indicators make troubleshooting quick and easy. Each
10/100/1000T port has 2 LED indicators that display the link status,
transmission speed and collision status. Also other LED indicators help
you diagnose the system immediately.

2
Packing List
1 x 8-port 10/100/1000Base-T Industrial Ethernet Switch
1 x Terminal Block
Safety Precaution
Attention
If DC voltage is supplied by an external circuit, please use a
protection device on the power supply input.

3
Hardware Description
In this paragraph, we will introduce the Industrial switch’s dimensions,
port, cabling information, and wiring installation.
Front Panel
The Front Panel of the IGS-0008B/IPGS-0008B is shown as below.
Front Panel of the Industrial Switch

4
Top View
The top panel of the Industrial Switch is equipped one terminal block
connector of two DC power inputs.
Top panel of the Industrial Switch Converter
Dimensions
. The dimensions of IGS-0008B are 35 x 152 x 105 mm (W x H x D).
The figure below gives the dimensions and views of each side of the
8-port 10/100/1000Base-T Industrial Switch.

5
The dimensions of IPGS-0008B are 43 x 152 x 105 mm (W x H x D). The
figure below gives the dimensions and views of each side of the 8-port
10/100/1000Base-T Industrial Switch.

6
Wiring the Power Inputs
Please follow the steps below to insert the power wire.
1. Insert the positive and negative wires into the V+ and V- contacts on the
terminal block connector.
2. To tighten the wire-clamp screws for preventing the DC wires to loose.
Wiring the Fault Alarm Contact
The fault alarm contact is in the middle of terminal block connector as the
picture shows below. Inserting the wires, it will detect the fault status
which the power is failure or port link failure (for managed model) and form
an open circuit.

7
Note
The wire gauge for the terminal block should be in the range
between 12~ 24 AWG.
Insert the wires into the fault alarm contact (No. 3 & 4)

8
LED Indicators
The LED indicators located on the front panel display the power status
and network status of the Industrial switch; each has their own specific
meaning as the table shown below.
LED
Color
Description
P1
Green
On
Power input 1 is active
Off
Power input 1 is inactive
P2
Green
On
Power input 2 is active
Off
Power input 2 is inactive
Fault
Red
On
Power input 1 or 2 is inactive
Off
Power input 1 and 2 are both functional, or no power
inputs
1 ~ 8
(Upper LED)
Green
On
Connected to network
Flashing
Networking is active
Off
Not connected to network
1 ~ 8
(Lower LED)
Yellow
On
Connected to network at speed of 1000Mbps
Off
Not connected to network or not working at speed of
1000Mbps

9
RJ-45 Pin Assignments
The UTP/STP ports will automatically sense for Fast Ethernet
(10Base-T/100Base-TX) or Gigabit Ethernet
(10Base-T/100Base-TX/1000Base-T) connection. Auto MDI/MDIX means that
the switch can connect to another switch or workstation without changing
straight through or crossover cabling. See the figures below for straight
through and crossover cable schema.
10/100Base-TX Pinouts
Pin Number
Assignment
1
Tx+
2
Tx-
3
Rx+
6
Rx-
Note
“+” and “-” signs represent the polarity of the wires that make up
each wire pair.
The table below shows the 10Base-T/100Base-TX MDI and MDI-X port
pinouts.
Pin Number
MDI-X Signal Name
MDI Signal Name
1
Receive Data plus (RD+)
Transmit Data plus (TD+)
2
Receive Data minus (RD-)
Transmit Data minus (TD-)
3
Transmit Data plus (TD+)
Receive Data plus (RD+)
6
Transmit Data minus (TD-)
Receive Data minus (RD-)

10
10/100Base-TX Cable Schema
Straight Through Cable Schema
Crossover Cable Schema
10/100/1000Base-T Pinouts
The table below describes the gigabit Ethernet RJ-45 pinouts.
Pin
Signal name
Description
1
BI_DA+
Bi-directional pair A+
2
BI_DA-
Bi-directional pair A-
3
BI_DB+
Bi-directional pair B+
4
BI_DC+
Bi-directional pair C+
5
BI_DC-
Bi-directional pair C-
6
BI_DB-
Bi-directional pair B-
7
BI_DD+
Bi-directional pair D+
8
BI_DD-
Bi-directional pair D-

11
10/100/1000Base-T Cable Schema
The following two figures illustrate the 10/100/1000Base-T cable
schema.
Straight Through Cable Schema
Crossover Cable Schema
Cabling
Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable
for RJ-45 connections: 100ΩCategory 3, 4 or 5 cable for 10Mbps
connections, 100ΩCategory 5 cable for 100Mbps, or 100ΩCategory
5e/above cable for 1000Mbps connections.
The cable between the switch and the link partner (switch, hub,
workstation, etc.) must be less than 100 meters (328 ft.) long.

12
Mounting Installation
DIN-Rail Mounting
Assembling the DIN-Rail Clip
The DIN-rail clip is screwed on the industrial switch when out of factory.
If not, please refer to the following steps and figure to secure the
DIN-rail clip on the switch.
1, Use the screws to screw on the DIN-rail clip on the industrial switch.
2, To remove the DIN-rail clip, reverse step 1.
Rear Panel of
the switch
DIN-rail clip

13
Hanging the Industrial Switch
Follow the steps below to hang the industrial switch on the DIN rail.
1, First, position the rear side of the switch directly in front of the DIN rail.
Make sure the top of the clip hooks over the top of the DIN rail.
2, Push the unit downward.
3, Check the DIN-Rail clip is tightly fixed on the DIN rail.
4, To remove the industrial switch from the track, reverse the steps above.

14
Wall-Mount Plate Mounting
*Optional Wall Mount Kit required
Follow the steps below to mount the industrial switch with the wall mount
plates included.
1. To remove the DIN-Rail clip from the industrial switch, unscrew the
screws to remove the DIN-Rail clip.
2. Place the wall-mount plates on the rear panel of the industrial switch.
3. Use the screws to secure the wall-mount plates on the industrial
switch.
4. Use the hook holes at the corners of the wall-mount plates to hang the
industrial switch on the wall.
5. To remove the wall-mount plates, reverse the steps above.

15
Hardware Installation
In this paragraph, we will describe how to install the 8-port
10/100/1000Base-TX Industrial Switch and the installation points for the
attention.

16
Installation Steps
1. Unpacked the Industrial switch.
2. Check the DIN-Rail is screwed on the Industrial switch. If the DIN-Rail is
not screwed on the Industrial switch. Please refer to DIN-Rail Mounting
section for DIN-Rail installation. If you want to wall mount the Industrial
switch, then please refer to Wall-Mount Plate Mounting section for wall
mount plate installation.
3. To hang the Industrial switch on the DIN-Rail track or wall, please refer to
the Mounting Installation section.
4. Power on the Industrial switch. How to wire the power; please refer to the
Wiring the Power Inputs section. The power LED on the Industrial switch
will light up. Please refer to the LED Indicators section for meaning of
LED lights.
5. Prepare the twisted-pair, straight through Category 5e cable for Ethernet
connection.
6. Insert one side of Category 5e or above cable into the Industrial switch
RJ-45 port and another side of category 5e or above cable to the network
devices’RJ-45 port, ex: switch, PC or Server. The RJ-45 LED indicator on
the Industrial switch will light up when the cable is connected with the
network device. Please refer to the LED Indicators section for LED light
meaning.
7. When all connections are all set and LED lights all show in normal, the
installation is complete.
This manual suits for next models
1
Table of contents
Other Lantech Network Router manuals

Lantech
Lantech TPGS-L6408XFTR User manual

Lantech
Lantech TPGS-0008CA User manual

Lantech
Lantech IMR-3002 User manual

Lantech
Lantech TWAP-5006 User manual

Lantech
Lantech TWMR-5002 User manual

Lantech
Lantech IWMR-3002 User manual

Lantech
Lantech IMR-3002 User manual

Lantech
Lantech IES-1204FT User manual

Lantech
Lantech IWMR-3003 User manual

Lantech
Lantech IPES-2204F User manual