lap 930PG Manual

Instruction leaflet
Shutter PIR
Outdoor Wall Light
27/05/2021
930PG
UK Manufacturer:
Kingfisher International Products Limited,
3 Sheldon Square, London, W2 6PX,
United Kingdom.
EU Manufacturer:
Kingfisher International Products B.V.
Rapenburgerstraat 175E,
1011 VM Amsterdam, The Netherlands.
The unit must be installed in a vertical position, and fitted
1.2m above the ground. The PIR sensor can be adjusted
using the SENS and TIME dials.
The detection angle is set at 105 degrees. The maximum
detection distance is 9m.
The length of time that the light is on can be adjusted
by turning the ‘Time’ dial, which can be altered between
8 seconds to 9 minutes duration. See (1) below.
Adjust the light level that the lamp switches on by
adjusting the 'LUX' screw (2).
PIR Adjustment
• Fitting/Replacing the bulbs - 1 x MAX 60W E27 GLS
or energy saving equivalent.
• Always allow the bulb to cool before touching.
Fit the recommended bulbs. Do not exceed the
recommended wattage or use a different shape of
bulb as this may cause your light fitting to overheat.
Fitting/replacing bulbs
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist.
Check with your Local Authority or retailer for recycling advice. The packaging on this product can also be recycled.
Recycling advice
Safety information
We recommend cleaning with a soft dry cloth.
Do not use solvents or abrasive cleaners as these could
damage the finish.
Plastic parts – Wipe clean with a damp cloth. Do not use
abrasive materials as these will damage the finish.
Do not clean the units with a pressure washer.
Cleaning
For your safety, always switch off the supply before changing lightbulbs, or cleaning.
The glass shade must be replaced if it becomes cracked or damaged.
Do not use product without glass shade attached. Replace Cracked
Shade
N
L
N
L
Max.8M
105°
1-2M
~1.7M
LUX
9min
8sec
2
2
2lux
2000lux
T
6
8
3
4
5
19
2
7
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Warning
Fixing Instructions
Specification
Voltage: 240V 50Hz
Lamp: Max. 1 x 60W E27 GLS
IP rating: 44
Make sure you have the following items which
are required to install this light fitting:
• Selection of cross and flat head screwdrivers.
• Electric drill and assorted drill bits.
• Wire strippers.
• Insulation tape.
This is a Class 1 product and must be earthed.
Please read these instructions carefully before
commencing any work, and retain for reference.
Install in accordance with IEE Wiring regulations
and current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure other
persons cannot restore the electrical supply without
your knowledge. If you are in any doubt, please consult
a qualified electrician.
This light fitting should be connected to a circuit
with a 30mA RCD fitted.
When changing a bulb, always switch off at the
mains and allow the old bulb to cool before handling.
Dispose of used bulbs carefully and responsibly.
Do not exceed the wattage stated or use a different
shape bulb as indicated on the fitting. This product
is not suitable for dimming.
Waste electrical products should not be disposed of
with household waste. Please recycle where facilities
exist. Check with your local authority or retailer for
recycling advice.
This product is rated at IP44. It is not suitable for
location in or near a marine or sea environment.
• Remove the back box (4) by undoing the finials (1)
from the threaded bolts.
• Use the back box as a template and mark and make the
holes, making sure the back plate is correctly aligned so
that the threaded bolts are horizontal.
• Bring the mains cable through the rubber grommet,
then use appropriate fixings (3) to secure the back box
to the wall.
• Unscrew the cap (7) and retain the two side screws (6).
• Fit the bulb (8). NOTE: Never fit bulbs of a higher
wattage than those specified on the label as these
may cause overheating and damage the fitting.
Refit the cap, ensuring the seal is tight. There are two
indents to ensure the cap is aligned correctly.
Installation
Layout
• Decide on the position of the light fitting, or remove
existing light fitting. Note the position of the electrical
connections. Ensure there is a solid mounting surface,
preferably a brick wall, to support the weight of the
light fitting.
• Refit the lamp over the 2 threaded bolts in the back plate
and secure with the rubber washer and finials (1).
Take care not to trap or strain the internal cables.
• Turn on the power and test. The PIR sensor settings
(9) can be altered by turning the dials under the fitting
marked ‘SENS’ and ‘TIME’.
Commissioning
Check that...
• You have correctly identified the house wires.
• The connections are tight.
• The cable entry grommet is securely in place to ensure
that the water ingress protection is maintained.
• The Terminal Block is wrapped and wiring is overlapped
both sides with 2 layers of insulation tape.
Wiring
Having correctly identified the wiring from your existing
light fitting, pull the wire through the hole and connect
to the connection block (5) inside the product in the
following way:
NEUTRAL
EARTH
SWITCHED LIVE
BLUE (N)
GREEN/YELLOW or
METALLIC EAR
TH CONNECTION
BROWN (L)
HOUSEHOLD SUPPLY LIGHT FITTING
4th BLOCK PROVIDED FOR LOOP
TERMINATION IF NECESSARY
N
L
N
L
Max.8M
105°
1-2M
~1.7M
LUX
9min
8sec
2
2
2lux
2000lux
T
6
8
3
4
5
19
2
7

Other lap Lighting Equipment manuals

lap 775PG Manual

lap

lap 775PG Manual

lap 50697 Manual

lap

lap 50697 Manual

lap BF3-1L12NC User manual

lap

lap BF3-1L12NC User manual

lap G03306 User manual

lap

lap G03306 User manual

lap 48429 Manual

lap

lap 48429 Manual

lap 213PP User manual

lap

lap 213PP User manual

lap APW1008 User manual

lap

lap APW1008 User manual

lap AFD1018-NB User manual

lap

lap AFD1018-NB User manual

Popular Lighting Equipment manuals by other brands

Clas Ohlson LUM-112X159W1-01D manual

Clas Ohlson

Clas Ohlson LUM-112X159W1-01D manual

GAME OF BRICKS Millennium Falcon 75192 instruction manual

GAME OF BRICKS

GAME OF BRICKS Millennium Falcon 75192 instruction manual

Karma DJ 359 instruction manual

Karma

Karma DJ 359 instruction manual

PROEL PLC56AL user manual

PROEL

PROEL PLC56AL user manual

Viatek LL03-RG-MOV-R instructions

Viatek

Viatek LL03-RG-MOV-R instructions

Robin Robin Cyclone user manual

Robin

Robin Robin Cyclone user manual

JB Systems Lynx II LED Operation manual

JB Systems

JB Systems Lynx II LED Operation manual

walser Walimex Pro 380 Bi Color RLL-380BV instruction manual

walser

walser Walimex Pro 380 Bi Color RLL-380BV instruction manual

Biotop Garden D0420 user manual

Biotop Garden

Biotop Garden D0420 user manual

Chauvet Professional COLORado 1QS Quick reference guide

Chauvet Professional

Chauvet Professional COLORado 1QS Quick reference guide

Robe CLUBSPOT 160 CT user manual

Robe

Robe CLUBSPOT 160 CT user manual

Larson Electronics GAU-ID-36-1L-UVC-SPF instruction manual

Larson Electronics

Larson Electronics GAU-ID-36-1L-UVC-SPF instruction manual

Hess TOLEDO Series Installation and operating instructions

Hess

Hess TOLEDO Series Installation and operating instructions

thomann PAR64 10MM UV user manual

thomann

thomann PAR64 10MM UV user manual

Light Plan LPL2-SS Suspended installation instructions

Light Plan

Light Plan LPL2-SS Suspended installation instructions

Chauvet DJ 4BAR Flex Q ILS user manual

Chauvet DJ

Chauvet DJ 4BAR Flex Q ILS user manual

Robus VEGAS EXPRESS RVA3K671 instructions

Robus

Robus VEGAS EXPRESS RVA3K671 instructions

Chauvet STRIKE P38 user manual

Chauvet

Chauvet STRIKE P38 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.