manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Leader Light
  6. •
  7. Lighting Equipment
  8. •
  9. Leader Light LL44 700 User manual

Leader Light LL44 700 User manual

USER MANUAL
LL FLOOD SPOT
Leader Light s.r.o.
M.Gorkeho 33
SK-052 01 Spisska Nova Ves
Slovakia
www.leaderlight.eu
LL44 700
All dimensions are in milimeters
ENVIRONMENT
Do not throw away the appliance with the normal household waste at the end of its life,
but hand it in at an ofcial collection point for recycling. By doing this, you help to preserve
the environment.
02 PRODUCT SPECIFICATION
02.1 Technical Specication
©MMX - Leader Light – All right reserved If you have any question please, contact [email protected]
COMPLIMENTS ON YOUR PURCHASE!
Content:
01 SAFETY INFORMATION
01.1 Risk of eyes damage
01.2 Protection from electric shock
01.3 Fire prevention
02 PRODUCT SPECIFICATION
02.1 Technical Specication
02.2 Back panel
03 INSTALLATION
03.1 Unpacking
03.2 Physical installation
03.3 Connecting to AC power
03.4 Control data connecting
03.5 DMX channels
04 MAINTENANCE
Edition: A - 2010
Lamp type: 16 x RGB 3x1W P5 *
Lifetime: Long 50 000 hrs 70% degradation
Optic: Standard 25°, on request: 10°, 40° and EL
Control data Input: DMX 512 In/Out with 1m cable
Input power: max. 100W
Power connection: 100-260V AC 50-60Hz In 1m cable
Net weight: 3kg
IP:
IP65
Ambient temp. (Ta):
max. +40°C
Cooling: Conventional
Materials and nish:
Powder-painted anodized aluminium RAL9006
(other colours on request)
Installation: Surface mounting
215
195
140
*P5: RGB-Red and Green and Blue
WARNING!!!
Carefully read before installing, powering or servicing.
Nothing to do if anything misunderstand! Installation can be done only
by a qualied professional in accordance with relevant local codes.
01 SAFETY INFORMATION
01.1 Risk of eyes damage
Do not look directly into LED lamps.
Do not look into light beam from a distance of less than 40 cm (16 inches)!
-
-
01.2 Protection from electric shock
Shut down power before installation or maintenance.
Luminaries and recommended AC power supply must be installed by a qualied
professional in accordance with relevant local codes. Only acceptable source of AC power
and frequency that complies with local building and electrical codes to use.
Do not use or do not connect the products if the power cable, power plug or xtures are any
way damaged, wet, or if they are overheating.
Do not modify, alter, or attempt to service the LeaderLight appliance. Doing so will void the
warranty.
Before removing or installing any cover or part of appliance disconnect it from AC power.
Appliance always connect to earth (eltech.).
-
-
-
-
-
-
01.3 Fire prevention
Follow all safety consideration.
Thermostatic switches or fuses never to bypass.
Device never shield. Around the axis of the tting (180°) must be maintained space for
cooling. Minimum distance from the surrounding objects must be 100mm (4 in.) (gure 1.1).
LEDs never direct cover with lters or other materials.
Allowing max. ambient temperature is 40°C (104°F).
Luminaries never use without mounting brackets. The housing never install directly to the
surface.
-
-
-
-
-
-
WARNING!!!
!!
Non-minimum distance and / or non-use the original brackets is at your own risk!
LED INDICATION STATUS
POWER (Green) blinking – 2Hz OK - inside xture is everything correct
DATA (Yellow) light off NO DMX512 signal
DATA (Yellow) blinking – 4Hz OK- income correct DMX512 signal
DATA (Yellow) fast blinking NON correct digital signal
POWER (Green) alternate blinking Autotest function
DATA (Yellow)
Control LEDs Indication POWER DATA
03 INSTALLATION
03.1 Unpacking
Unpack carefully.
This is electronic equipment and should be handled carefully.
Damaged delivered package or if are any mechanical parts broken – it must be claim
immediately by the transport company. Photo pictures as evidence are valuable for
future claim.
-
-
-
03.2 Physical installation
Loading capacity of bearing area has to be at least 10 times the weight of all device
clusters (luminaries, clamps, cables, ...).
Hairbreadth from combustible materials is 0,5m.
-
-
03.3 Connecting to AC power
To tackle all Safety Information- 01!
For protection from electric shock, the device must be grounded (earthed)!
It is not necessary to open the xture before power supply.
Power supply is solved simple with Neutrik PowerCon connectors.
The xture is equipped with auto-switching power supply that automatically adjusts to
any 50-60Hz AC power source from 100-260V.
Cord plug connections:
-
-
-
-
-
-
02.2 Back panel
Symbol Pin Wire Colour Screw (US)
Llive brown yellow or brass
Nneutral blue silver
ground (earth) yellow/green green
03.4 Control data connecting
Control data cable length is specied by Norm IEC929 Annex E4.
It is not necessary to open the xture before connecting of DMX512 control signal.
Interconnections are realized by Neutrik XLR 5pin IN/Out connectors.
Pin connections:
Pin 1 – ground
Pin 2 – signal negative
Pin 3 – signal positive
-
-
-
Dip options » Rotating DIP address 000÷511
“100“ “10“ “1“
Control LEDs
POWER DATA
MODE & ADDRESS
DMX Out
XLR-5pin
DMX In
XLR-5pin
DMX512
Power In
PowerCon
POWER
Following items are included:
- LL FLOOD SPOT 1m power cable with PowerCon 1 pc.
- Adjustable mounting bracket 1 pc.
- User manual 1 pc.
Additional items needed:
- Data cables with XLR 5pin Female/Male
- Controller compatible with DMX 1 pc.
Surface mounting:
- Screws and washers M12, M10
If you have any question please, contact [email protected]
Order code Product name
LL44 700 LL FLOOD SPOT RGB IP65
04 MAINTENANCE
To tackle all Safety Information- 01!
Damage caused by inadequate cleaning or maintenance is not coveredby warranty.
Regular cleaning is demand (dust, dirt, ...).
Maintenance policy:
Unplug mains before maintenance and at least 10 minutes cool off
Appliance do not illegal open or demount
Clean-up dust only from outer surface (for ex. scuttle, diffuser and lenses).
Use vacuum or dumpy duster (warm water)
Before reinstalling to check failure-free state – no wet parts!
-
-
-
-
-
-
-
-
03.5 DMX channels - subject to change
The latest version of DMX channels appendix are on the websites - www. leaderlight.eu
-
DMX channels:
dmx1 = Red
dmx2 = Green
dmx3 = Blue
Switch functions Dip4:
Dip1 = ExtMode (+2 ch.: Master, Strobo)
Dip2 for future
Dip3 for future
Dip4 = Ultra soft curve
Ventilation space 180° free
Minimal mounting distance from surface 1.1
minimal.
80mm minimal.
80mm
Ventilation space 90° free
minimal.
100mm
minimal.
80mm
INSTALLATION SPACE
Screw the xture to the surface (M12 or 2xM10)
1.2
Surface installation
Unx by hand the screw and aim the xture to the wish position and x.
180°
AIMING POSSIBILITY
The xture could be aim to wish
position with bracket.
180°
IP RATING
IP 65 - only up ligting
position
max. +/- 60°

Other Leader Light Lighting Equipment manuals

Leader Light LL50 450 User manual

Leader Light

Leader Light LL50 450 User manual

Leader Light LL46 400 User manual

Leader Light

Leader Light LL46 400 User manual

Leader Light LL50 450 User manual

Leader Light

Leader Light LL50 450 User manual

Leader Light LL HBDW DS21-NA-I20 Series User manual

Leader Light

Leader Light LL HBDW DS21-NA-I20 Series User manual

Leader Light LL HBDW PS21-NA-I20 Series User manual

Leader Light

Leader Light LL HBDW PS21-NA-I20 Series User manual

Leader Light LL FLOOD WASH User manual

Leader Light

Leader Light LL FLOOD WASH User manual

Leader Light LL STAGE 6-06D User manual

Leader Light

Leader Light LL STAGE 6-06D User manual

Leader Light LL SPORT 4K User manual

Leader Light

Leader Light LL SPORT 4K User manual

Leader Light LL ARC SPOT 19 User manual

Leader Light

Leader Light LL ARC SPOT 19 User manual

Popular Lighting Equipment manuals by other brands

Chauvet COLORdash Par-Hex 7 user manual

Chauvet

Chauvet COLORdash Par-Hex 7 user manual

urmet domus 1033/282 manual

urmet domus

urmet domus 1033/282 manual

Treasure Garden Vega-L Assembly and operation guide

Treasure Garden

Treasure Garden Vega-L Assembly and operation guide

Ibiza LED-LAMP-BT instruction manual

Ibiza

Ibiza LED-LAMP-BT instruction manual

OPTOCEUTICS EVY LIGHT user manual

OPTOCEUTICS

OPTOCEUTICS EVY LIGHT user manual

Lightolier 83EC specification

Lightolier

Lightolier 83EC specification

Emos ZU210.12 manual

Emos

Emos ZU210.12 manual

Robus OHIO RHC0830-01 Instruction leaflet

Robus

Robus OHIO RHC0830-01 Instruction leaflet

unios Moka MOKA0002 instructions

unios

unios Moka MOKA0002 instructions

WAC Lighting InvisiLED CCT 100 Installation instruction

WAC Lighting

WAC Lighting InvisiLED CCT 100 Installation instruction

Kichler Lighting 11304NILED quick start guide

Kichler Lighting

Kichler Lighting 11304NILED quick start guide

Elation Event MH owner's manual

Elation

Elation Event MH owner's manual

Clas Ohlson SP-LS3MCCTW12-60D-01B quick start guide

Clas Ohlson

Clas Ohlson SP-LS3MCCTW12-60D-01B quick start guide

LIGMAN DU-10216-1 installation manual

LIGMAN

LIGMAN DU-10216-1 installation manual

Cameo ZENIT W600 D SMD user manual

Cameo

Cameo ZENIT W600 D SMD user manual

EuroLite DM-250 Lighting-Effect user manual

EuroLite

EuroLite DM-250 Lighting-Effect user manual

Ecco ED3040 Installation and operation instruction

Ecco

Ecco ED3040 Installation and operation instruction

Lighting Technologies ARS/S manual

Lighting Technologies

Lighting Technologies ARS/S manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.