Ledj Q Colour LEDJ210 User manual

Order code: LEDJ210
Q Colour
18 x 8W RGBW LEDs
User Manual

www.prolight.co.uk Q Colour User Manual 2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CARE-
FULLY BEFORE YOUR INITIAL START-UP!
• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablemainssupplyvoltageis
between100~240VAC,50/60Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreached
roomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProLight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• Thislightingxtureisforprofessionaluseonly-itis
notdesignedfororsuitableforhouseholduse.The
productmustbeinstalledbyaqualiedtechnicianin
accordancewithlocalterritoryregulations.Thesafetyof
theinstallationistheresponsibilityoftheinstaller.The
xturepresentsrisksofsevereinjuryordeathduetore
hazards,electricshockandfalls.
• Warning!RiskGroup2LEDproductaccordingto
EN62471.Donotviewthelightoutputwithoptical
instrumentsoranydevicethatmayconcentratethebeam.
• WARRANTY:Oneyearfromdateofpurchase.

www.prolight.co.uk Q Colour User Manual 3
Product overview & technical specications
Utilisingquad-colourLEDtechnologytheQColouraddsintensecolourtostagesandperformers.
Thexturehasaruggedchassisandprovidesexceptionalquality,coverageandeaseofuse.
Withtheabilitytorunbuilt-inprogramsandperformfullRGBWcolourmixingwithorwithout
DMXcontrolthextureisalsoperfectforarchitecturalworkandinstallation.
•18x8Wquad-colourLEDs(RGBW)
•Beamangle:25°
•400Hzrefreshrate
•DMXchannels:4or6selectable
•Staticcolour,colourmix,colourchange,colourfade,
auto,soundactiveandmaster/slavemodes
•0-100%dimmingandvariablestrobe
•Bracketallowsformultiplerigging
oroorstandingapplications
•3pushbuttonmenuwithLEDdisplay
•IECpowerinput/output
•3-PinXLRinput/output
•Fancooled
Q Colour
Specications Q Colour
Powerconsumption 160W
Powersupply 100~240V,50/60Hz
Fuse T2A250V
Dimensions 222x344x153mm
Weight 4.7kg
Ordercode LEDJ210
222mm
344mm 153mm
0m 1m 2m 3m 4m 5m
25° - Lux 8410 2512 1008
25°
625 384

www.prolight.co.uk Q Colour User Manual 4
Technical specications & operating instructions
01-Fuse:T2A250V
02-IECpowerinput
03-IECpoweroutput
04-Earthpoint
05-3-PinDMXinput
06-3-PinDMXoutput
07-LEDdisplay
08-MODEbutton
09-UPbutton
10-DOWNbutton Inthebox:1 x xture,
1 x power cable &
1 x user manual
www.prolight.co.uk
MODE
DMX INPUT
POWER INPUT/OUTPUT:100-240V~50/60HZ
FUSE: T2A 250V
DMX OUTPUT
DOWN UP
02
09 1008
0301
04
05
07
06
DMX address mode:
Toaccessstaticmodepress“MODE”untilthedisplayshowsAddontheLEDdisplayandusethe
“UP”and“DOWN”buttonstoselecttheDMXaddressrequired001~512.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
DMX channel mode:
Toaccessstaticmodepress“MODE”untilthedisplayshows4CHontheLEDdisplayandusethe
“UP”and“DOWN”buttonstoselectoneofthebetween4or6channelmodes.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.

www.prolight.co.uk Q Colour User Manual 5
Static colour mode:
Toaccessstaticmodepress“MODE”untilthe
displayshowsC01ontheLEDdisplayanduse
the“UP”and“DOWN”buttonstoselectoneofthe
15coloursC01~C15.Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Built-in program mode:
Toaccessthexturesbuilt-inprogramspress“MODE”untilthedisplayshowsP01ontheLEDdisplay
andusethe“UP”and“DOWN”buttonstoselectoneofthe9built-inprogramsP01~P09.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Slave mode:
Pressthe“MODE”buttonontherearoftheunittoshowAddontheLEDdisplayandusethe
“UP”and“DOWN”buttonsuntilthedisplayshows001theunitwillnowruninsequencewith
themasterunit.Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
PleaseensurethatallslaveunitsaresettothesameDMXchannelmodeasthemasterunit.
Sound active mode:
Toaccesssoundactivepress“MODE”untilthedisplayshowsS99ontheLEDdisplayandusethe
“UP”and“DOWN”buttonstoselectthesensitivitylevelS00~S99.
(S00-lowsensitivity,S99-highsensitivity).
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
RGB colour mixing:
ToselecttheRGBcolourmixingmode,pressthe“MODE”buttontoshowr--ontheLCDdisplay.
Nowpressusethe“UP” and“DOWN”buttonstoselecttheamoutofredrequired.Pressthe“MODE”
buttonandrepeatforGreen,BlueandWhite(00-99).
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Operating instructions
Channel Value Function
1 000-255 Red(0-100%)
2000-255 Green(0-100%)
3000-255 Blue(0-100%)
4 000-255 White(0-100%)
4 channel mode:
Channel Value Function
1 000-255 Red(0-100%)
2000-255 Green(0-100%)
3000-255 Blue(0-100%)
4 000-255 White(0-100%)
5 000-255 Masterdimmer(0-100%)
6 000 DMXcontrolCH1-CH5
001-005 15coloursoundactive
006-010 DMXcontrolCH1-CH5
011-255 Strobe(slow-fast)
6 channel mode:
C01-Red C02-Green C03-Blue C04-White(W) C05-Yellow
C06-Purple C07-Cyan C08-White(RGB) C09-Pink C10-LightGreen
C11-LightBlue C12-LightYellow C13-Magenta C14-LightCyan C15-White(RGBW)
P01 7colourchange P04 3colourfade P07 15colourchange
P02 7colourfade P05 7coloursoundactive P08 15colourfade
P03 3colourchange P06 3coloursoundactive P09 15coloursoundactive

www.prolight.co.uk Q Colour User Manual 6
DMX setup
FurtherDMXcablescanbe
purchasedfromallgoodsound
andlightingsuppliersor
ProLightConceptsdealers.
Pleasequote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachxturerequiresa“startaddress”
from1-512.Axturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannel
indicatedbythestartaddress.Forexample,axturethatoccupiesoruses7channelsofDMXandwas
addressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105
and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthe
chainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligent
xturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothexture.
DMXdataissentasserialdatathattravelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”
XLRterminalslocatedonallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogether
andoperatefromasinglecontroller,aslongasallxturesandthecontrollerareDMXcompliant.
ToensureproperDMXdatatransmission,whenusingseveralDMXxturestrytousetheshortest
cablepathpossible.TheorderinwhichxturesareconnectedinaDMXlinedoesnotinuencethe
DMXaddressing.Forexample;axtureassignedtoaDMXaddressof1maybeplacedanywherein
aDMXline,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigneda
DMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,
nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisxturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.
YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,
seeimagebelow.
Also remember that DMX cable must be daisy chained and cannot be split.

www.prolight.co.uk Q Colour User Manual 7
Terminationreducessignaltransmission
problemsandinterferance.itisalways
advisabletoconnectaDMXterminal,
(resistance120Ohm1/4W)betweenpin2
(DMX-)andpin3(DMX+)ofthelastxture.
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.Donotconnectthecables
shieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRs
outercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,
youmayneedtouseaterminatoron
thelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL9O, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRxtures
maybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa
3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.

www.prolight.co.uk Q Colour User Manual 8
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedof
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.
Table of contents
Other Ledj Floodlight manuals

Ledj
Ledj LEDJ252B User manual

Ledj
Ledj Quad illuminator User manual

Ledj
Ledj Spectra Led Flood (Exterior) User manual

Ledj
Ledj ALU ZOOM PAR 64 User manual

Ledj
Ledj Stage Wash 36 User manual

Ledj
Ledj LEDJ286 User manual

Ledj
Ledj Slimline 229 User manual

Ledj
Ledj PERFORMER 54 RGBW User manual

Ledj
Ledj STAR18 User manual

Ledj
Ledj Omni WA-36 User manual

Ledj
Ledj Intense 9HEX10 User manual

Ledj
Ledj Q Pix Batten LEDJ97 User manual

Ledj
Ledj Slimline 7T3 User manual

Ledj
Ledj Slimline 9Q8 User manual

Ledj
Ledj HEX Par 7 User manual

Ledj
Ledj Q Batten LEDJ300 User manual

Ledj
Ledj STAGE WASH U.V. 36 LEDJ106 User manual

Ledj
Ledj LEDJ98 User manual

Ledj
Ledj 19T3 User manual

Ledj
Ledj Eco LED 64 User manual