Ledj UV 100W COB Flood LEDJ185 User manual

Order code: LEDJ185
UV 100W COB Flood
1 x 100W UV LED
User Manual

www.prolight.co.uk UV 100W COB Flood User Manual
2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablevoltageisbetween
110~240V,50/60Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreached
roomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProLight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• WARRANTY:Oneyearfromdateofpurchase.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!

www.prolight.co.uk UV 100W COB Flood User Manual
3
Product overview & technical specications
FeaturingCOB(chip-on-board)technologytheLEDJUV100WCOBFloodisloadedwitha100WUVLEDwhichis
housedina50°reector.Controloftheunitisfacilitatedviaa4buttonmenuandLCDdisplay.Thewholexture
isenclosedinarobustcastaluminiumhousing.
Please note:TheCOBUVLEDinstalledinto
thisxturehasdispersedLEDemitters,you
maynoticethatnotallpixelswillilluminate.
Thisistoenablebettercoolingacrossthe
chipanddoesnotindicateafaultyLED.
•1x100WUVCOBLED
•Beamangle:50°(eldangle:80°)
•1.1kHzrefreshrate
•DMXchannels:1or2selectable
•Standalone,soundactiveandmaster/slavemodes
•0-100%dimmingwithvariablestrobe
•4pushbuttonmenuwithLEDdisplay
•Captivepowerconnection
•3-pinXLRin/outsockets
•Fancooled
•Suppliedwithhangingbracketandlterframe
•Optional10°(ELUM102)or25°(ELUM103)lenses
•OptionalBarnDoors(ELUM041C)
UV 100W COB Flood
Specications UV 100W COB Flood
Powerconsumption 110W
Powersupply 110~240V,50/60Hz
Fuse F2A250V
Dimensions 303x300x180mm
Weight 3.7kg
Ordercode LEDJ185
01-Safetyeye
02-Earthpoint
03-LEDdisplay
04-Functionbuttons
05-DMXinputsocket
06-DMXoutputsocket
07-Captivepowerconnection
08-FuseF2A250V
Inthebox:1 x xture,
& 1 x user manual
300mm
280mm
07
01
03
04
02
08 05 06
www.prolight.co.uk
FUSE: F2A 250V
SAFETY
EYE
DMX
IN
DMX
OUT
PUSH
MENU UPENTER DOWN
POWER SUPPLY:
100-240V~50/60Hz
COB FLOOD
UV
100W

www.prolight.co.uk UV 100W COB Flood User Manual
4
Operating instructions
DMX channel mode:
ToaccesstheDMXchannelmode,pressthe“MODE”buttonontherearoftheunittoshowA001
ontheLEDdisplay.Nowpressthe“ENTER”buttonandusethe“UP”and“DOWN”buttonstosetthe
desiredDMXaddress.Nowpressthe“ENTER”buttontochooseoneofthe1or2DMXchannelmodes
usingthe“UP”and“DOWN”buttons,andpressthe“ENTER”usethe“UP”and“DOWN”buttonstoset
whattheunitshoulddoifitlosesDMXsignal.
bLC-TheunitwillblackoutifDMXsignalislost.
Soun-TheunitwillgointosoundactivemodeifDMXsignalislost.
HoLd-TheunitwillholdthelastDMXcommandifDMXsignalislost.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Static mode:
Toaccessstaticmodepress“ENTER”untilthedisplayshowsC-00ontheLEDdisplay.
Toadjustthebrightnessusethe“UP”and“DOWN”buttonstoselectbetweenC-00~C-99.
Pressthe“ENTER”buttontoconrmthesetting.Nowusethe“UP”and“DOWN”buttonstoadjustthe
ashspeedbyselectingbetweenF-00~F-99.Pressthe“ENTER”buttontoconrmthesetting.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Slave mode:
Pressthe“MODE”buttonontherearoftheunittoshowSLAUontheLEDdisplayandpressthe
“ENTER”buttontoconrmthesetting.Theunitwillnowruninsequencewiththemasterunit.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
PleaseensurethatallslaveunitsaresettothesameDMXchannelmodeasthemasterunit.
Sound active mode:
Toaccessthesoundactivemode,pressthe“MODE”buttonontherearoftheunittoshowSU00
ontheLEDdisplay.Nowpressthe“ENTER”buttonandusethe“UP”and“DOWN”buttonstosetthe
soundsensitivitylevelfromSU.00~SU.99andpressthe“ENTER”buttontoconrmthesetting.
Value: 00 - 99 (00 = low, 99 = high)
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Channel Value Function
1000-255 Masterdimmer(0-100%)
Channel Value Function
1000-255 Masterdimmer(0-100%)
2000-255 Flashspeed(slowtofast)
1 channel mode: 2 channel mode:
Staticmode C-00~C-99Brightness(0-100%)
F-00~F-99Flashspeed(slow-fast)
Slavemode SLAV
Soundactivemode SU00~SU99
Menusystem
DMXmode 1CH,2CH
Addresssetting A001~A512

www.prolight.co.uk UV 100W COB Flood User Manual
5
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachxturerequiresa“startaddress”
from1-512.Axturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannel
indicatedbythestartaddress.Forexample,axturethatoccupiesoruses7channelsofDMXandwas
addressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105
and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthe
chainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligent
xturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothexture.
DMXdataissentasserialdatathattravelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”
XLRterminalslocatedonallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogether
andoperatefromasinglecontroller,aslongasallxturesandthecontrollerareDMXcompliant.
ToensureproperDMXdatatransmission,whenusingseveralDMXxturestrytousetheshortest
cablepathpossible.TheorderinwhichxturesareconnectedinaDMXlinedoesnotinuencethe
DMXaddressing.Forexample;axtureassignedtoaDMXaddressof1maybeplacedanywherein
aDMXline,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigneda
DMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,
nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisxturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.
YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,
seeimagebelow.
Also remember that DMX cable must be daisy chained and cannot be split.
DMX setup
FurtherDMXcablescanbe
purchasedfromallgoodsound
andlightingsuppliersor
ProLightConceptsdealers.
Pleasequote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

www.prolight.co.uk UV 100W COB Flood User Manual
6
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.Donotconnectthecables
shieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRs
outercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,
youmayneedtouseaterminatoron
thelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL9O, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRxtures
maybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa
3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmission
problemsandinterferance.itisalways
advisabletoconnectaDMXterminal,
(resistance120Ohm1/4W)betweenpin2
(DMX-)andpin3(DMX+)ofthelastxture.
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup

www.prolight.co.uk UV 100W COB Flood User Manual
7
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedof
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.

www.prolight.co.uk 8
UV 100W COB Flood User Manual
Table of contents
Other Ledj Floodlight manuals

Ledj
Ledj Q Batten LEDJ300 User manual

Ledj
Ledj Slimline 7T3 User manual

Ledj
Ledj LEDJ252B User manual

Ledj
Ledj STAGE WASH U.V. 36 LEDJ106 User manual

Ledj
Ledj Intense 9HEX10 User manual

Ledj
Ledj Spectra Par 6HEX10 User manual

Ledj
Ledj ALU ZOOM PAR 64 User manual

Ledj
Ledj PERFORMER 54 RGBW User manual

Ledj
Ledj LEDJ98 User manual

Ledj
Ledj INTENSE 12D4 CW User manual

Ledj
Ledj Omni WA-36 User manual

Ledj
Ledj HEX Par 7 User manual

Ledj
Ledj Eco LED 64 User manual

Ledj
Ledj Q Colour User manual

Ledj
Ledj LEDJ01 User manual

Ledj
Ledj Slimline 9Q8 User manual

Ledj
Ledj Quad illuminator User manual

Ledj
Ledj LEDJ01 User manual

Ledj
Ledj STAGE COLOUR 24 TRI User manual

Ledj
Ledj Spectra Led Flood (Exterior) User manual