Ledj Stage Par CZ 120 RGBA User manual

Order codes:
LEDJ192 - Black Housing
LEDJ192P - Polished Housing
Stage Par CZ 120 RGBA
User Manual

www.prolight.co.uk Stage Par CZ 120 RGBA User Manual
2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Before your initial start-up, please make sure that there is no damage caused during transportation.
• Should there be any damage, consult your dealer and do not use the equipment.
• To maintain the equipment in good working condition and to ensure safe operation, it is necessary
for the user to follow the safety instructions and warning notes written in this manual.
• Please note that damages caused by user modications to this equipment are not subject to warranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc.
Do not endanger your own safety and the safety of others!
Incorrect installation or use can cause serious damage to people and/or property.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
• Never let the power cable come into contact with other
cables. Handle the power cable and all mains voltage
connections with particular caution!
• Never remove warning or informative labels from the unit.
• Do not open the equipment and do not modify the unit.
• Do not connect this equipment to a dimmer pack.
• Do not switch the equipment on and off in short intervals,
as this will reduce the system’s life.
• Only use the equipment indoors.
• Do not expose to ammable sources, liquids or gases.
• Always disconnect the power from the mains when
equipment is not in use or before cleaning! Only handle
the power-cable by the plug. Never pull out the plug by
pulling the power-cable.
• Make sure that the available mains supply voltage is
between 100~240V AC, 50/60Hz.
• Make sure that the power cable is never crimped or
damaged. Check the equipment and the power cable
periodically.
• If the equipment is dropped or damaged, disconnect the
mains power supply immediately and have a qualied
engineer inspect the equipment before operating again.
• If the equipment has been exposed to drastic
temperature uctuation (e.g. after transportation),
do not connect power or switch it on immediately.
The arising condensation might damage the equipment.
Leave the equipment switched off until it has reached
room temperature.
• If your product fails to function correctly, stop use
immediately. Pack the unit securely (preferably in the
original packing material), and return it to your Pro Light
dealer for service.
• Only use fuses of same type and rating.
• Repairs, servicing and power connection must only be
carried out by a qualied technician. THIS UNIT CONTAINS
NO USER SERVICEABLE PARTS.
• This lighting xture is for professional use only - it is
not designed for or suitable for household use. The
product must be installed by a qualied technician in
accordance with local territory regulations. The safety of
the installation is the responsibility of the installer. The
xture presents risks of severe injury or death due to re
hazards, electric shock and falls.
• Warning! Risk Group 2 LED product according to
EN 62471. Do not view the light output with optical
instruments or any device that may concentrate the beam.
• WARRANTY: One year from date of purchase.

www.prolight.co.uk Stage Par CZ 120 RGBA User Manual
3
Stage Par CZ 120 RGBA
FUSE:
T2A 250V
100-240V~50/60Hz
POWER CONSUMPTION: 150W
POWER INPUT POWER OUTPUT
SAFETY
EYE
DMX OUTPUTDMX INPUT
MENU ENTERDOWNUP
www.prolight.co.uk
01
02
07
03
04
0605 08 09
Product overview & technical specications
The CZ 120 RGBA Stage Par is powered by a high output 120W quad-colour COB (chip-on-board) RGBA LED, ideal
for stage productions, concerts or theatre applications. The beam angle can be manually adjusted between 15°
and 35° and on-board controls offer 4 different dimmer curve options, whilst the 5-pin DMX and powerCON input/
output allow for easy connections, adding to the host of professional features on these xtures. The traditional par
can style housing is available in black or polished aluminium and a gel frame holder is supplied enabling diffusion
lters to be tted.
• 1 x 120W quad-colour LED (RGBA)
• Manually adjustable beam angle: 15° - 35°
• 13,800 Lux @ 2m (full on)
• 3kHz refresh rate
• DMX channels: 4/7 or 11 selectable
• Manual and master/slave modes
plus built-in programs
• 0-100% dimming and variable strobe
• Supplied with hanging bracket
• 4 push button menu with LED display
• PowerCON input/output
• 5-Pin XLR input/output
• Fan cooled
• Filter frame included
Stage Par CZ 120 RGBA
Specications Stage Par CZ 120
Power consumption 150W
Power supply 100~240V, 50/60Hz
Fuse T2A 250V
Dimensions 405 x 302 x 444mm
Weight 3.9kg
Order codes LEDJ192 - Black Housing
LEDJ192P - Polished Housing
01 - LED display
02 - Function buttons
03 - 5-Pin XLR input
04 - 5-Pin XLR output
05 - PowerCON input
06 - PowerCON output
07 - Fuse T2A 250V
08 - Earth point
09 - Safety eye
In the box: 1 x xture,
1 x lter frame,
1 x power cable
& 1 x user manual

www.prolight.co.uk Stage Par CZ 120 RGBA User Manual
4
Beam angle (lens) adjustment:
To adjust the beam angle squeeze the spring loaded latch inside the front nose of the par can.
The latch can then be moved forwards or backwards smoothly, allowing the operator to select
the beam angle required between 15° and 35° using the markers provided as a guide.
Release the spring loaded latch once the beam angle has been selected to prevent any
further movement.
405mm
302mm
237mm
444mm
419mm
Product overview & technical specications

www.prolight.co.uk Stage Par CZ 120 RGBA User Manual
5
Operating instructionsOperating instructionsOperating instructions
MENU
0 0 1
5 1 2
A d d r
DMX address setting
O N
O F F
N A S t
Master setting
S L 1
S L 2
S L N d
Slave setting
b L N d
L A S t
d N S t
No DMX signal
S N O O
F A S t
S P d
Dimmer speed setting
CUrV
Dimming curves
LIN
SqU
I S q U
S C U r
4 C H
7 C H
1 1 C H
C H N d
Channel modes
S H N d
Show modes
Colour macros
Co01
Co64
S H 0
S H 1
S H 9
S P 0 0
S P 9 9

www.prolight.co.uk Stage Par CZ 120 RGBA User Manual
6
Operating instructions
N A N U
Manual mode
000
255
r E d
000
255
g r E E
000
255
b L U E
000
255
A N b E
000
255
S t r 0
000
255
d I N N
- - - -F H r s
Fixture hours
t - - -t E N p
Fixture temperature
A U t Ot E S t
Auto test
U---UEr
Software version
N O
y E S
F A C t
Reset factory settings
O N
O F F
L E d
LED backlight
d I S P
d S I p
d I S P
Display invert
MENU

www.prolight.co.uk Stage Par CZ 120 RGBA User Manual
7
Operating instructions
DMX mode:
Operating in a DMX control mode environment gives the user the greatest exibility when it comes
to customising or creating a show. In this mode you will be able to control each individual trait of
the xture and each xture independently.
To access the DMX address mode, press the “MENU” button and use the “UP” and “DOWN” buttons to
show Addr on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons
to set the required DMX address. Press the “ENTER” button to conrm the setting.
To exit out of any of the above options, press the “MENU” button.
DMX channel mode:
To access the DMX channel mode, press the “MENU” button and use the “UP” and “DOWN” buttons to
show CHNd on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons
to choose one of the 4/7 or 11 DMX channel modes. Press the “ENTER” button to conrm the setting.
To exit out of any of the above options, press the “MENU” button.
4 channel mode:
Channel Value Function
CH1 000-255 Red dimmer (0-100%)
CH2 000-255 Green dimmer (0-100%)
CH3 000-255 Blue dimmer (0-100%)
CH4 000-255 Amber dimmer (0-100%)
7 channel mode:
Channel Value Function
CH1 000-255 Red dimmer (0-100%)
CH2 000-255 Green dimmer (0-100%)
CH3 000-255 Blue dimmer (0-100%)
CH4 000-255 Amber dimmer (0-100%)
CH5 000-255 Colour temperature (3000K-7000K)
CH6 000-255 Master dimmer (0-100%)
CH7
000-031 No function
032-063 Open
064-095 Strobe (slow-fast)
096-127 Open
128-159 Pulse strobe (slow-fast)
160-191 Open
192-223 Random strobe (slow-fast)
224-255 Open
11 channel mode:
Channel Value Function
CH1 000-255 Red dimmer (0-100%)
CH2 000-255 Green dimmer (0-100%)
CH3 000-255 Blue dimmer (0-100%)
CH4 000-255 Amber dimmer (0-100%)
CH5 000 No function
001-004 Colour 1
005-008 Colour 2
009-012 Colour 3
013-016 Colour 4
017-020 Colour 5
021-024 Colour 6
025-028 Colour 7
029-032 Colour 8
033-036 Colour 9
037-040 Colour 10
041-044 Colour 11
045-048 Colour 12
049-052 Colour 13
053-056 Colour 14
057-060 Colour 15
061-064 Colour 16
065-068 Colour 17
069-072 Colour 18
073-076 Colour 19

www.prolight.co.uk Stage Par CZ 120 RGBA User Manual
8
Operating instructions
Channel Value Function
CH5
cont.
077-080 Colour 20
081-084 Colour 21
085-088 Colour 22
089-092 Colour 23
093-096 Colour 24
097-100 Colour 25
101-104 Colour 26
105-108 Colour 27
109-112 Colour 28
113-116 Colour 29
117-120 Colour 30
121-124 Colour 31
125-128 Colour 32
129-132 Colour 33
133-136 Colour 34
137-140 Colour 35
141-144 Colour 36
145-148 Colour 37
149-152 Colour 38
153-156 Colour 39
157-160 Colour 40
161-164 Colour 41
165-168 Colour 42
169-172 Colour 43
173-176 Colour 44
177-180 Colour 45
181-184 Colour 46
185-188 Colour 47
189-192 Colour 48
193-196 Colour 49
197-200 Colour 50
201-204 Colour 51
205-208 Colour 52
209-212 Colour 53
213-216 Colour 54
217-220 Colour 55
221-224 Colour 56
225-228 Colour 57
229-232 Colour 58
Channel Value Function
CH5
cont.
233-236 Colour 59
237-240 Colour 60
241-244 Colour 61
245-248 Colour 62
249-252 Colour 63
253-255 Colour 64
CH6 000-255 Colour temperature (3000K-7000K)
CH7 000-255 Master dimmer (0-100%)
CH8 000-255 Dimmer ne (0-100%)
CH9
000-031 No function
032-063 Open
064-095 Strobe (slow-fast)
096-127 Open
128-159 Pulse strobe (slow-fast)
160-191 Open
192-223 Random strobe (slow-fast)
224-255 Open
CH10
000-002 No function
003-030 Show 1
031-058 Show 2
059-086 Show 3
087-114 Show 4
115-142 Show 5
143-170 Show 6
171-198 Show 7
199-226 Show 8
227-255 Show 9
CH11 000-255 Show mode speed (slow-fast)
11 channel mode:

www.prolight.co.uk Stage Par CZ 120 RGBA User Manual
9
Master/slave mode:
To set the master unit, press the “MENU” button and use the “UP” and “DOWN” buttons to show
NASt on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to
choose ON choose OFF. Press the “ENTER” button to conrm the setting.
Then select your desired program.
To set the other units in slave mode, press the “MENU” button and use the “UP” and “DOWN” buttons to
show SLNd on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons
to choose either SL 1~ SL 2. Press the “ENTER” button to conrm the setting. The unit will now run
in sequence with the master unit. To exit out of any of the above options, press the “MENU” button.
Please ensure that all slave units are set to the same DMX channel mode as the master unit.
Show mode:
To access the show modes, press the “MENU” button and use the “UP” and “DOWN” buttons to show
SHNd on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to
choose between SH 0 ~ SH 9.
To change the speed of the selected program press the “ENTER” button and then use the “UP” and
“DOWN” buttons to select any value from SP00 ~ SP99.
Press the “ENTER” button to conrm the setting.
In SH 0 you are able to set a specic static colour. When in SH 0 press the “ENTER” button and
then use the “UP” and “DOWN” buttons to go through the static colours. Press the “ENTER” button to
conrm the setting.
To exit out of any of the above options, press the “MENU” button.
Operating instructions
Show 0 Colour macros (Colour 1 - Colour 64)
Show 1 3 colour fade (red, green, blue)
Show 2 4 colour fade (red, green, blue, amber)
Show 3 3 colour fade (red, green, blue) with amber @ 100%
Show 4 4 colour change (red, green, blue, amber)
Show 5 10 colour change (red, green, blue, amber, yellow, magenta, cyan, orange, lime green, lilac)
Show 6 Red continuous fade in/out
Show 7 Green continuous fade in/out
Show 8 Blue continuous fade in/out
Show 9 Amber continuous fade in/out

www.prolight.co.uk Stage Par CZ 120 RGBA User Manual
10
Operating instructions
No DMX signal:
To change how the unit responds when the DMX signal is lost, press the “MENU” button and use the
“UP” and “DOWN” buttons to show dNSt on the LED display. Now press the “ENTER” button and
use the “UP” and “DOWN” buttons to choose between LAst (Hold the last DMX command) or
bLNd (Blackout). Press the “ENTER” button to conrm the setting.
To exit out of any of the above options, press the “MENU” button.
Dimming curves:
To access the dimming curve setting, press the “MENU” button to show CUrU on the LED display.
Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose between
LIN (Linear), SqU (Square), ISqU (Inverse square) or SCUr (S-Curve).
Press the “ENTER” button to conrm the setting.
To exit out of any of the above options, press the “MENU” button.
Dimming speed:
To access the dimmer speed setting, press the “MENU” button and use the “UP” and “DOWN” buttons
to show Spd on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN”
buttons to choose between SNoo (Smooth) or FAst (Fast).
Press the “ENTER” button to conrm the setting.
To exit out of any of the above options, press the “MENU” button.
LED backlight:
To access the LED backlight setting, press the “MENU” button and use the “UP” and “DOWN” buttons to
show LEd on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons
to choose between ON or OfF. Press the “ENTER” button to conrm the setting. To exit out of any of
the above options, press the “MENU” button.
Display invert setting:
To access the display invert setting, press the “MENU” button and use the “UP” and “DOWN” buttons to
show dIsp on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons
to choose between dISP or dSIP. Press the “ENTER” button to conrm the setting. To exit out of
any of the above options, press the “MENU” button.
Manual mode:
To access manual mode, press the “MENU” button to show NANU on the LED display.
Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose between rEd (Red),
grEE (Green), bLUE (Blue), ANbE (Amber), Str0 (Strobe) and dINN (Master dimmer).
Press the “ENTER” button and use the “UP” and “DOWN” buttons to choose between 000 ~ 255.
Press the “ENTER” button to conrm the setting.
To exit out of any of the above options, press the “MENU” button.

www.prolight.co.uk Stage Par CZ 120 RGBA User Manual
11
Fixture temperature:
To access the xtures temperature, press the “MENU” button and use the “UP” and “DOWN” buttons
to show tENp on the LED display. Now press the “ENTER” button.
The unit will now display the xtures temperature.
To exit out of any of the above options, press the “MENU” button.
Test mode:
To access the test mode, press the “MENU” button and use the “UP” and “DOWN” buttons to show
tEst on the LED display. Now press the “ENTER” button.
The unit will now display AUtO and run the xtures test mode.
To exit out of any of the above options, press the “MENU” button.
Fixture temperature:
To access the xtures temperature, press the “MENU” button and use the “UP” and “DOWN” buttons
to show tENp on the LED display. Now press the “ENTER” button.
The unit will now display the xtures temperature.
To exit out of any of the above options, press the “MENU” button.
Fixture hours:
To access the xtures usage time, press the “MENU” button and use the “UP” and “DOWN” buttons
to show FHrS on the LED display. Now press the “ENTER” button.
The unit will now display the xtures usage time (hours).
To exit out of any of the above options, press the “MENU” button.
Reset factory settings:
To reset factory settings, press the “MENU” button and use the “UP” and “DOWN” buttons to show
FACt on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to
choose yEs. Press the “ENTER” button to conrm the setting. The xture will reset to factory default
settings. To exit out of any of the above options, press the “MENU” button.
Software version:
To access the xtures software version, press the “MENU” button and use the “UP” and “DOWN” buttons
to show VEr on the LED display. Now press the “ENTER” button.
The unit will now display the xtures software version.
To exit out of any of the above options, press the “MENU” button.
Operating instructions

www.prolight.co.uk Stage Par CZ 120 RGBA User Manual
12
Setting the DMX address:
The DMX mode enables the use of a universal DMX controller. Each xture requires a “start address”
from 1- 512. A xture requiring one or more channels for control begins to read the data on the channel
indicated by the start address. For example, a xture that occupies or uses 7 channels of DMX and was
addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104,
105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in
the chain starts at 107.
DMX 512:
DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent
xtures and controllers. A DMX controller sends DMX data instructions form the controller to the xture.
DMX data is sent as serial data that travels from xture to xture via the DATA “IN” and DATA “OUT”
XLR terminals located on all DMX xtures (most controllers only have a data “out” terminal).
DMX linking:
DMX is a language allowing all makes and models of different manufactures to be linked together
and operate from a single controller, as long as all xtures and the controller are DMX compliant.
To ensure proper DMX data transmission, when using several DMX xtures try to use the shortest
cable path possible. The order in which xtures are connected in a DMX line does not inuence the
DMX addressing. For example; a xture assigned to a DMX address of 1 may be placed anywhere in
a DMX line, at the beginning, at the end, or anywhere in the middle. When a xture is assigned a
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,
no matter where it is located in the DMX chain.
DATA cable (DMX cable) requirements (for DMX operation):
This xture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit.
Your unit requires either a standard 3-pin or 5-pin XLR connector for data input/output,
see images below.
Also remember that DMX cable must be daisy chained and cannot be split.
DMX setup
Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight Concepts dealers.
Please quote: CABL10 – 2m CABL11 – 5m CABL12 – 10m3-Pin:
CABL185 – 2m CABL187 – 5m CABL188 – 10m5-Pin:

www.prolight.co.uk Stage Par CZ 120 RGBA User Manual
13
Notice:
Be sure to follow the diagrams below when making your own cables.
Do not connect the cables shield conductor to the ground lug or
allow the shield conductor to come in contact with the XLRs
outer casing. Grounding the shield could cause a short circuit
and erratic behaviour.
Line termination:
When longer runs of cable are used,
you may need to use a terminator on
the last unit to avoid erratic behaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90,
5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR xtures
may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a
3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion.
5-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup
Termination reduces signal
transmission problems and
interference. It is always
advisable to connect a DMX
terminal, (resistance 120
Ohm 1/4W) between pin 2
(DMX-) and pin 3 (DMX+) of
the last xture.
5-Pin
1
2 4
5
3
3-Pin
1 2
3
Pin Conguration
3-Pin 5-Pin
Pin 1 - Ground
Pin 2 - Negative
Pin 3 - Positive
– Pin 4 - N/C
– Pin 5 - N/C
1
2
3
1
2
3
DMX 512
3-Pin XLR output
DMX 512
3-Pin XLR input
GROUND
DMX +
DMX –
DMX 512
5-Pin XLR output
DMX 512
5-Pin XLR input
1
2
45
3
12
4
5
3
GROUND
N/C
DMX –
N/C DMX +
1 ground
3 hot
2 cold
3-Pin XLR male 3-Pin XLR female
2 cold
3 hot
1 ground
2 cold
1 ground 5 N/C
3 hot 4 N/C
5-Pin XLR male 5-Pin XLR female
4 N/C
5 N/C 1 ground
3 hot 2 cold

www.prolight.co.uk Stage Par CZ 120 RGBA User Manual
14
Multiple xture power linking
Power linking:
This xture provides power linking via the power output on the rear allowing multiple units to be
conneted together. The maximum number of xtures that can be connected is 15 xtures @ 240V
or 7 xtures @ 120V (including the rst xture). After the maximum number of xtures are
connected a new power run will need to be started.
Please note: Caution should be used when power linking other xtures to the Stage Par CZ 120 RGBA
as the power consumption of other xtures will vary. Fixtures tted with lamps often require 2/3 times
more current on startup, these may require their own power source.
Stage Par CZ 120 RGBA
FUSE:
T2A 250V
100-240V~50/60Hz
POWER CONSUMPTION: 150W
POWER INPUT POWER OUTPUT
SAFETY
EYE
DMX OUTPUTDMX INPUT
MENU ENTERDOWNUP
www.prolight.co.uk
Stage Par CZ 120 RGBA
FUSE:
T2A 250V
100-240V~50/60Hz
POWER CONSUMPTION: 150W
POWER INPUT POWER OUTPUT
SAFETY
EYE
DMX OUTPUTDMX INPUT
MENU ENTERDOWNUP
www.prolight.co.uk

www.prolight.co.uk Stage Par CZ 120 RGBA User Manual
15
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
This marking shown on the product or its literature, indicates that it should not be disposed of
with other household wastes at the end of its working life. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, please separate this from other
types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their
local government ofce, for details of where and how they can take this item for environmentally
safe recycling.
Business users should contact their supplier and check the terms and conditions of the
purchase contract. This product should not be mixed with other commercial wastes for disposal.

www.prolight.co.uk Stage Par CZ 120 RGBA User Manual
16
Table of contents
Other Ledj Lighting Equipment manuals

Ledj
Ledj LEDJ251 User manual

Ledj
Ledj Aspect User manual

Ledj
Ledj Colour Storm Quad User manual

Ledj
Ledj Spectra Flood 18HEX10 User manual

Ledj
Ledj HBR 1D User manual

Ledj
Ledj LEDJ266 User manual

Ledj
Ledj STAGE CLOUR QUAD User manual

Ledj
Ledj Razor Beam User manual

Ledj
Ledj ALU ZOOM PAR 64 User manual

Ledj
Ledj LED-56 User manual

Ledj
Ledj LEDJ02 User manual

Ledj
Ledj Slimline 1T100 User manual

Ledj
Ledj LEDJ255 User manual

Ledj
Ledj minibar TC User manual

Ledj
Ledj Event Panel User manual

Ledj
Ledj 18HEX10 PRO User manual

Ledj
Ledj LEDJ352A User manual

Ledj
Ledj HEX Par 9 User manual

Ledj
Ledj Stage Par CZ200 Dual White User manual

Ledj
Ledj SPECTRA BATTEN12T3 EXTERIOR User manual