Leica K3C User manual

Leica Microscope Camera
K3C, K3M, K5C, K8
User Manual

User Manual K3C, K3M, K5C, K8 2
Contents
General Notes
General Notes 4
Important Safety Notes 5
Symbols Used 6
Safety Instructions 7
Introduction
Standard Delivery and Optional Accessories 13
Overview K3C, K3M, K5C 14
Overview K8 15
Assembly
Assembling the Camera 17
PC Operation - Installation / Setup / Application
Connecting a Computer, Installing LASX Software 19
Using the Camera in LAS-X 20
Triggering the Camera 21
Filter Replacement 22
Gain (K8 Camera Only) 23
Triggering (K8 Camera Only) 24
Camera Fan Control (K8 Camera Only) 25
Care and Maintenance
Care, Maintenance, Contact Persons 27

User Manual K3C, K3M, K5C, K8 General Notes 3
General Notes

User Manual K3C, K3M, K5C, K8 General Notes 4
General Notes
Cleaning
ODo not use any unsuitable cleaning agents,
chemicals or techniques for cleaning.
ONever use chemicals to clean colored
surfaces or accessories with rubberized
parts. This could damage the surfaces, and
specimens could be contaminated by abra-
ded particles.
OFollow the notes regarding cleaning the
filter glass.
OIn most cases it is OK to use a wipe
dampened with 70 % ethanol in distilled
water.
Servicing
ORepairs may only be carried out by Leica
Microsystems-trained service engineers.
Only original Leica Microsystems spare
parts may be used.
Responsibilities of person in charge of
camera
OEnsure that the Leica microscope camera
is operated, maintained and repaired by
authorized and trained personnel only.

User Manual K3C, K3M, K5C, K8 General Notes 5
Important Safety Notes
User manual
The Leica microscope camera can be configu-
red in a variety of ways in the Leica product
range. User manuals and updates are available
for you to download and print from our web
site at www.leica-microsystems.com.
This user manual describes the special func-
tions of the Leica microscope camera and
contains important instructions for operating
safety, maintenance and the accessory parts.
You can combine individual system articles
with articles from external suppliers (e.g. light
sources, etc.). Please read the user manual and
the safety instructions from the supplier.
Before installing, operating or using the instru-
ments, read the user manuals listed above. In
particular, please follow all safety instructions.
To maintain the unit in its original condition
and to ensure safe operation, the user must
follow the instructions and warnings contained
in these user manuals.

User Manual K3C, K3M, K5C, K8 General Notes 6
Symbols Used
Read and understand this user
manual before using this camera.
Warning! Safety hazard!
This symbol indicates especially
important information that is
mandatory to read and observe.
Failure to comply can cause the
following:
OPersonal injury!
OInstrument malfunctions and damage.
Warning of hazardous electrical voltage
This symbol indicates especially
important information. Failure to
comply can cause the following:
OPersonal injury!
OInstrument malfunctions and damage.
Instrument malfunctions and damage
This symbol warns against touching
hot surfaces, such as light bulbs.
Important information
This symbol indicates additional
information or explanations that are
intended to provide clarity.

User Manual K3C, K3M, K5C, K8 General Notes 7
Safety Instructions
Intended use
This camera system is designed for use by engi-
neers and scientists. It is a scientific measuring
instrument, which provides images.
The camera may only be used according to the
instructions of this user manual. The disclosures
and operating conditions in this user manual
must be respected. Unauthorized modifica-
tions and changes of the device are forbidden
for safety reasons.
Non-intended use
Never use the Leica microscope camera or its
components for diagnostic procedures if it is
not expressly intended for such use.
The instruments and accessories described in
this user manual have been tested for safety
and potential hazards.
The responsible Leica affiliate must be consul-
ted whenever the instrument is altered, modi-
fied or used in conjunction with non-Leica
components that are outside of the scope of
this user manual!
Unauthorized alterations to the instrument or
noncompliant use shall void all rights to any
warranty claims.
Place of use
OElectrical components must be placed at
least 10 cm away from the wall and from
flammable substances.
OAvoid large temperature fluctuations, direct
sunlight and vibrations. These conditions
can distort the functionality of the camera.
OIn warm and damp climates, the individual
components require special care in order to
prevent the build-up of fungus.
Responsibilities of person in charge of
instrument
Ensure that:
OThe Leica microscope camera and accesso-
ries are operated, maintained and repaired
by authorized and trained personnel only.
OAll operators have read, understood and
observe this user manual, and particularly
the safety regulations.

User Manual K3C, K3M, K5C, K8 General Notes 8
Safety Instructions (Continued)
Transport
OUse the original packaging for shipping or
transporting the individual modules of the
Leica microscope camera and the acces-
sory components.
EU Declaration of Conformity
To download the EU Declaration of Conformity
use the link http://www.leica-microsystems.
com/products.
Health risks
Workplaces with microscopes facilitate and
improve the viewing task, but they also impose
high demands on the eyes and muscles of the
user. Depending on the duration of uninter-
rupted work, asthenopia and musculoskeletal
problems may occur. For this reason, approp-
riate measures for reduction of the workload
must be taken:
OOptimal arrangement of workplace, work
assignments and work flow (changing tasks
frequently).
OThorough training of the personnel, giving
consideration to ergonomic and organizati-
onal aspects.
The ergonomic optical design and construction
of Leica microscopes are intended to reduce the
exertion of the user to a minimum.
The manufacturer assumes no liabi-
lity for damage caused by, or any
risks arising from using the device
for other purposes than those for
which they are intended or not
using them within the specifications
of Leica Microsystems CMS GmbH.
In the event of such, the declaration
of conformity shall become null and
void.
This device is not intended for use
in the patient environment defined
by DIN VDE 0100-710. Neither is it
intended for combining with medi-
cal devices according to
93/42/EWG and/or IVD devices
according to 98/78/EG (2107/746).
If this device is electrically connec-
ted to a medical device according
to EN60601-1, the requirements
defined in EN60601-1-1 shall apply.

User Manual K3C, K3M, K5C, K8 General Notes 9
Safety Instructions (Continued)
This user manual is an essential
component of the camera, and must
be read carefully before the camera
is assembled, put into operation
or used, and must be kept for later
references.
Instrument safety and EMC
Our device has been designed, produced and
tested in compliance with:
ORadio interference suppression in compli-
ance with EN 55011 class B (Class A for K8
only)
OEN 61326-1/IEC 61326-1, Electrical equip-
ment for measurement, control and labora-
tory use – EMC requirements
The device meets the requirements of EU
directives:
O2014/30/EU EMC directive
O2014/35/EU low voltage directive
O2011/65/EU RoHS directive
O2009/125/EC + VO EU 1194/2012 Ecodesign
requirements for energy-related products
O2009/125/EC + VO EU 2019/1782 Ecodesign
requirements for energy-related product
and carries the CE mark.
K8 camera only: This camera is constructed
and tested in accordance with EN 61010-1 /
IEC61010-1, Safety requirements for electrical
equipment for measurement, control and labo-
ratory use and EN61326-1/ IEC61326-1, Elec-
trical equipment for measurement, control and
laboratory user – EMC requirements.
The device must be disposed of in
accordance with 2012/19/EU WEEE
directive.
Intended for indoor use only in all EU member
states, EFTA states and Switzerland.
In order to maintain this condition
and to ensure safe operation, the
user must follow the instructions
and warnings contained in this user
manual.
Unauthorized alterations to the
camera or noncompliant use shall
void all rights to any warranty claims
and product liability!

User Manual K3C, K3M, K5C, K8 General Notes 10
Tolerable ambient conditions
OTemperature: +10 °C ... 40 °C
ORelative humidity: 10% ... 90 %,
non-condensing
Do not use the device in altitudes
exceeding 2000 m ASL/NL.
Transport and storage in a range of
-10° – +60 °C and at a humidity not
exceeding 70 % (non-condensing).
Make sure that a free air circulation
is provided.
The electrical components are not
protected against water. Water can
cause electric shock.
Do not use this camera near sources
of high electromagnetic radiation
(for example, unshielded, intentio-
nally operated ultra-high frequency
sources), because these can disrupt
proper operation.
We recommend assessing the elec-
tromagnetic environment before
operation of this camera and then
giving corresponding instructions.
This user manual is an essential
component of the product; it must
be read carefully before the camera
is assembled, put into operation
or used, and must be kept for later
reference.
Only insert or unplug data and
control circuits when the camera is
switched off; otherwise, the camera
may be damaged.
Illustrations, descriptions and tech-
nical data are not binding and may
be changed without notice.
You will find the latest release of this
user manual and other information
on our web site at www.leica-micro-
systems.com.
Electrical components must be assembled at
least 10cm from the wall and away from flam-
mable substances.
This device is not intended for use in the pati-
ent environment defined by DINVDE0100-710.
Neither is it intended for combining with medi-
cal advices according to EN 60601-1. If this
device is electrically connected to a medical
device according to EN 60601-1, the require-
ments defined in EN60601-1-1 shall apply.
Safety Instructions (Continued)

User Manual K3C, K3M, K5C, K8 General Notes 11
Safety Instructions (Continued)
Technical data external power supply for
camera K8
Only use the power supply (LPS certified) provi-
ded by Leica Microsystems. In the event of a
defect, contact the Leica Service.
OSupply voltage: 100-240 VAC
OFrequency: 50/60 Hz
OPower: max. 60 W
OOutput voltage: 12 VDC
OOutput power: max. 5 A
Electrical safety in accordance to IEC 62368-1.
Cleaning
Caution!
Acetone, xylene and nitro-contai-
ning thinner can harm the device
and thus may not be used.
Test clean solutions of unknown
composition first on a less visible
area of the unit. Be sure that coated
or plastic surfaces do not become
matted or etched.

User Manual K3C, K3M, K5C, K8 Introduction 12
Introduction

User Manual K3C, K3M, K5C, K8 Introduction 13
Standard delivery
Standard delivery of the Leica microscope
camera includes:
1. Leica microscope camera
2. USB cable for connecting to a computer
3. PCIe USB card (K8 camera only)
4. Power supply unit (K8 camera only)
The number and layout of ports will
differ between camera models.
Additional information about
working on the computer and with
Leica Application Suite X (LAS X) is
provided in the software's online
help.
Standard Delivery and Optional Accessories

User Manual K3C, K3M, K5C, K8 Introduction 14
Overview K3C, K3M, K5C
1 2 3
1. USB 3 port for power supply and PC connection
2. LED light
3. Trigger port
LED states:
OLED red: Check USB connection to the PC
OLED green/ green blinking: Camera is ready
to communicate/ is working

User Manual K3C, K3M, K5C, K8 Introduction 15
Overview K8
1
4 5 6
2 3
1. ON / OFF switch
2. Power supply connection
3. LED light
4. Trigger port
5. Service port (Service only)
6. USB 3 port for PC connection
LED states:
OLED blinking: Camera is initializing
OLED off: Camera is ready to communicate

User Manual K3C, K3M, K5C, K8 Assembly 16
Assembly

User Manual K3C, K3M, K5C, K8 Assembly 17
The Leica microscope camera
is mounted on a tube or on a
microscope's photo port using a
C-mount adapter.
The Leica microscope camera is
compatible with most stereo, macro
and light microscopes from Leica
Microsystems.
Mount adapter for your camera type:
Camera Mount adapter
K3 OFor compounds use:
Micoscope c-mount: 0.55x
(Art.No.: 11541544)
OFor stereo use:
Microscope c-mount: 0.50x
(Art.No.: 110450528)
Camera Mount adapter
K5C OFor compounds use:
HC C-mount adapter 1x for
sCMOS (Art.No.: 11541551)
OFor stereo use:
Video Adapter 1x (Art.No.:
10450829)
K8 OFor compounds use:
HC C-mount adapter 1x for
sCMOS (Art.No.: 11541551)
OFor compounds use with fast
external filter wheels:
C-Mount adapter HC 1x
for filter wheel (Art.No.:
11541552)
OFor stereo use:
Video Adapter 1x (Art.No.:
10450829)
Connecting the camera
1. Screw the camera onto a C-mount adapter
for your camera type.
2. Place the camera on the microscope's
photo port or the tube using the previously
mounted C-mount adapter.
3. Connect the USB cable to the USB 3 port in
the PC and fasten the screws (see "Overview
K3C, K3M, K5C" on page 14 or "Overview
K8" on page 15).
4. K8 only: Connect the power supply (see
"Overview K8" on page 15).
In case of triggering the camera,
connect the trigger cable to to the
trigger port and secure it. Then
connect the trigger cable to a
compatible triggering device of your
choice.
Assembling the Camera

User Manual K3C, K3M, K5C, K8 PC Operation - Installation/ Setup/ Application 18
PC Operation - Installation/
Setup/ Application

User Manual K3C, K3M, K5C, K8 PC Operation - Installation/ Setup/ Application 19
Installation and connection
For instructions on installing and
using the LASX software for PC
mode, refer to the "Quick Installa-
tion Guide".
Prerequisite:
OThe camera is connected to the power
supply and the USB connection to the PC
is established (camera-dependent, see
"Overview K3C, K3M, K5C" on page 14 or
"Overview K8" on page 15).
1. After downloading the LAS X software,
follow the instructions for installing the
software. (The computer also has to have
sufficient free hard drive space).
2. Connect the Leica microscope camera to
a USB 3 port of the computer using the
USBcable.
3. In the Leica Hardware Controller, select
[Configure] and [Cameras] to enable the
camera within LAS-X by selecting the
available camera attached to a chosen
C-mount adapter.
4. Close the Leica hardware configurator.
Connecting a Computer, Installing LASX Software

User Manual K3C, K3M, K5C, K8 PC Operation - Installation/ Setup/ Application 20
Using the Camera in LAS-X
Starting the camera in LAS X
1. Start Leica Application Suite X (LAS X).
2. Follow the instructions in the software for adjusting and acquiring an
image.
For additional information on Leica
Application Suite X, please refer to
"LAS X Help".
You may be asked to specify your micro-
scope's current instrument configuration
when starting LAS X for the first time.
This manual suits for next models
3
Table of contents
Other Leica Microscope manuals

Leica
Leica TCS SP2 Reference guide

Leica
Leica SP8 User manual

Leica
Leica S4 E StereoZoom User manual

Leica
Leica BM E User manual

Leica
Leica DIGILUX 1 User manual

Leica
Leica DMLS User manual

Leica
Leica ATC 2000 User manual

Leica
Leica DM2700 M User manual

Leica
Leica IMS500 User manual

Leica
Leica BM E User manual

Leica
Leica M500 OH3 User manual

Leica
Leica DMS300 User manual

Leica
Leica Stellaris 8 FALCON Installation guide

Leica
Leica TCS SP8 User manual

Leica
Leica DMi8A User manual

Leica
Leica ICC50 E User manual

Leica
Leica DM750 M User manual

Leica
Leica TCS SP5 X User manual

Leica
Leica DM750 M User manual

Leica
Leica TCS SP5 X User manual