14ACX-041-230 TXV 39,000 15.70 13.50 CX34-43 EL296UH110XV48C 5685133
14ACX-041-230 TXV 38,500 16.00 13.50 CX34-43 EL296UH110XV60C 5057186
14ACX-041-230 TXV 39,000 16.00 13.00 CX34-43 SL280UH090V60C 3869118
14ACX-041-230 TXV 39,000 16.00 13.00 CX34-43 SL280UH090XV60C 4235237
14ACX-041-230 TXV 39,000 16.00 13.00 CX34-43 SL280UH110V60C 3869119
14ACX-041-230 TXV 39,000 16.00 13.00 CX34-43 SL280UH110XV60C 4040077
14ACX-041-230 TXV 38,500 15.50 13.00 CX34-43 SLP98UH090XV36C 5140454
14ACX-041-230 TXV 39,000 15.70 13.00 CX34-43 SLP98UH090XV48C 5140455
14ACX-041-230 TXV 39,000 15.50 13.00 CX34-43 SLP98UH090XV60C 5140456
14ACX-041-230 TXV 38,500 16.00 13.50 CX34-43 SLP98UH110XV60C 5140457
14ACX-041-230 TXV 38,000 15.20 13.00 CX34-44/48 EL180UH090E48B 5735105
14ACX-041-230 TXV 38,500 15.50 13.20 CX34-44/48 EL180UH090E60C 5735999
14ACX-041-230 TXV 38,000 15.20 13.00 CX34-44/48 EL180UH090XE48B 5737069
14ACX-041-230 TXV 38,000 15.50 13.20 CX34-44/48 EL180UH110E60C 5737823
14ACX-041-230 TXV 38,000 15.50 13.20 CX34-44/48 EL180UH110XE60C 5738895
14ACX-041-230 TXV 37,800 15.20 13.00 CX34-44/48 EL195UH090XE48C 4693860
14ACX-041-230 TXV 38,500 15.20 13.20 CX34-44/48 EL195UH110XE60C 4693873
14ACX-041-230 TXV 37,800 14.50 12.50 CX34-44/48 EL296UH045XV36B 5153069
14ACX-041-230 TXV 37,800 15.20 13.00 CX34-44/48 EL296UH090XE48C 5647245
14ACX-041-230 TXV 38,500 15.20 13.20 CX34-44/48 EL296UH110XE60C 5647258
14ACX-041-230 TXV 38,500 15.20 13.20 CX34-44/48 EL296UH110XV48C 5685134
14ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 EL180UH090E60C 5736001
14ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 EL180UH110E60C 5737825
14ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 EL180UH110XE60C 5738896
14ACX-041-230 TXV 39,500 16.00 13.50 CX34-49 EL195UH090XE48C 4693861
14ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 EL195UH110XE60C 4693874
14ACX-041-230 TXV 39,500 16.00 13.50 CX34-49 EL296UH090XE48C 5647246
14ACX-041-230 TXV 39,500 15.50 12.50 CX34-49 EL296UH090XV48C 7492823
14ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 EL296UH110XE60C 5647259
14ACX-041-230 TXV 39,500 16.00 13.50 CX34-49 EL296UH110XV48C 5685135
14ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 EL296UH110XV60C 5057193
14ACX-041-230 TXV 40,000 16.00 13.00 CX34-49 SL280UH090V60C 4253799
14ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 SL280UH110V60C 4253800
14ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 SLP98UH110XV60C 5140517
14ACX-041-230 TXV 39,000 14.50 12.50 CX34-49 3869121
14ACX-041-230 TXV 38,500 15.70 13.20 CX34-50/60C EL180UH090E60C 5736004
14ACX-041-230 TXV 38,500 15.70 13.20 CX34-50/60C EL180UH110E60C 5737828
14ACX-041-230 TXV 38,500 15.70 13.20 CX34-50/60C EL180UH110XE60C 5738899
14ACX-041-230 TXV 38,500 15.50 13.20 CX34-50/60C EL195UH090XE48C 4693862
14ACX-041-230 TXV 38,500 15.50 13.00 CX34-50/60C EL195UH110XE60C 4693875
14ACX-041-230 TXV 38,500 15.50 13.20 CX34-50/60C EL296UH090XE48C 5647247
14ACX-041-230 TXV 38,500 15.50 13.00 CX34-50/60C EL296UH110XE60C 5647260
14ACX-041-230 TXV 38,500 15.50 13.20 CX34-50/60C EL296UH110XV48C 5685136
14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL180UH090E60C 5736006
14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL180UH110E60C 5737830
14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL180UH110XE60C 5738900
14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL195UH090XE48C 4693863
14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL195UH110XE60C 4693876
14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL296UH090XE48C 5647248
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.